Tender for Construction And Renovation Of Toilet Blocks At District Court In Chinsurah(Electrical Works)
BOQ
| Sl. No. | Item Description |
| 1 | Sub-Head 1 - Distribution Wiring |
| 2 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending gooddamages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 7 mtr [ E-20/2(ii) ] |
| 3 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board [ E-20/3(i) ] |
| 4 | SUB-HEAD 2 - PLUGS, SOCKETS & SWITCH BOARDS |
| 5 | Supplying & fixing GI modular switch board of the following sizes complete with three nos. suitable size copper bar with holes (for ph. , N &E) fixed on bakelite / Hard rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 6 Module [E-17/1(b)] |
| 6 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(a)] |
| 7 | Supply & Fixing 240 V 6 A 5 pin Modular type plug socket (Brand approved by EIC) without switch & plug top on existing GI Modular type switch board with top cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc. [E-17/4(a)] |
| 8 | SUB-HEAD 3 - SPNDB & Main Switch |
| 9 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.2+4 Way, Make - Legrand (Enclosure - 607710), Havells (Enclosure - DHDPSNODRW04) / Standard (Enclosure DHDMSNHOSI04) [D- 9/13] |
| 10 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection (Make - Legrand / Siemens / Schneider ) 40 A DP [D- 5/6] |
| 11 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS (Make-Legrand/Siemens/Schneider) as per direction of EIC. 6-32 SP [D-6/7] |
| 12 | Supplying and fixing Sheet steel Main Switches on flat iron frame on wall32 Amp. 240V DP with fuse on L&N, Make - Standard /Havells / HPL [D-1/1(a)] |
| 13 | SUB-HEAD 4 - Laying of polythene pipe & drawing of copper wire |
| 14 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools19 mm dia. 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire [E-3/6(b)] |
| 15 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required3 x (1.5 sqmm) [E-9/1(b) ] |
| 16 | SUB-HEAD 5 - Supply & Laying of cable |
| 17 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire / strip armour for mechanical protection, and PVC / FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Non Schedule Item No. CABLE/ Page 1 / Item No. 1]2 Core 10 Sq. mm [Non Schedule Item No. CABLE/ Page 1 / Item No. 1.2] |
| 18 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [F- 2/1(a)] |
| 19 | Laying of cable as below, after cutting floor / pavement / wall / andmaking holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbishFrom 2.5 sq. mm. to 35 sqmm at an average depth of 75 mm in floor / pavement / wall etc. [F-3/5(i)] |
| 20 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE / PVC armoured cables as below :2 Core 10 Sq. mm [F4/7(a)] |
| 21 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :2 core 10 sq. mm. cable [F5/8(b)(iii)] |
| 22 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [C-2 / 17] |
| 23 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ C-2 / 16 ] |
| 24 | Supply & Fixing angular batten holder (Anchor) on 75 mm dia. PVC round block / round bakelite on wall/ceiling as per GS. [ D-13 / 22 ] |
| 25 | S & F 9W LED Bulb (Make - Philips, Cat no. - Ace Saver) or equivalent of Bajaj / CG / Magik. [NS] |
| 26 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [18/C-3] |
| 27 | Supplying & Fixing GI waterproof type looping cable box size 200 x 150 x 100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sq. mm. PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [H5/(H)5] |
| 28 | SUB-HEAD 7 - Suppply of Light Fittings |
| 29 | Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV (internal) with Short & Open circuit protection , THD < 10% , P.F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K / 6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark / Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt) [Non Schedule Item No. LED LIGHT/ Page 4 / Item No. 4]Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification [Non Schedule Item No. LED LIGHT/ Page 4 / Item No. 4.1.1] |
| 30 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driverefficiency > 80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy shall be as below : System lumen efficacy ≥135 lm/Watt [Non Schedule Item No. LED LIGHT/ Page 5 / Item No. 6]45 Watt [Non Schedule Item No. LED LIGHT/ Page 5 / Item No. 6.1.2] |
| 31 | SUB-HEAD 8 - Supply & Fixing of Fans |
| 32 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire [C-3/21(a)] |
| 33 | S & F 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18] |
| 34 | Fixing only exhaust fan after making holes in wall as per GS(9\\") [C-4 /28(a)] |
| 35 | (12\\") [C-4 /28(b)] |
| 36 | Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [Non Schedule Item No. FAN/ Page 1 / Item No. 1.2] |
| 37 | Supply & Fixing louver shutter ( Aluminium) on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS (9\\") [D-14/32(a)] |
| 38 | (12\\") [D-14/32(a)] |
| 39 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [Non Schedule Item No. FAN/ Page 2 / Item No. 2.1] |
| 40 | Supply & delivery of 230 V, 50 Hz, single phase, 48 watts, 12\\" (300 mm) Sweep, speed 900 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel / Al body. Power Factor not less than 0.9 and minimum air delivery 1145 cmh (minimum) capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 41 | Excavation of soil for installation of Earth Electrode and filling & ramming.For Soft Soil [G-1/1(a)] |
| 42 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: [G-1/2(a)]By ISI-Medium GI pipe |
| 43 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [G-2/3(a)] |
| 44 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [G-2/4(a)] |
| 45 | Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS No. - 4 SWG [G-2/5(a)(i)] |
| 46 | Add GST @18%:- Rs |
| 47 | Add LWC @1% Rs. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 24, 2026
17:00 IST