Tender For Supply, INSTALLATION And Electrification Of Air Conditioners In The Dj And Adj Court Rooms, Chambers And Office In District Court Badaun.
Tender Overview
Project Description
Tender for Supply, INSTALLATION And Electrification Of Air Conditioners In The Dj And Adj Court Rooms, Chambers And Office In District Court Badaun.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-Jul-2026 | Date Extent | Date | 07-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part II 2023. The system shall be able to operate up to 52 °C (out door ambient temperature).. 2.0 TR with 5 Star BEE RatingMake : Carrier/Panasonic/Blue Star/LG |
| 2 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part II 2023. The system shall be able to operate up to 52 °C (out door ambient temperature)..1.5 TR with 5 Star BEE RatingMake : Carrier/Panasonic/Blue Star/LG |
| 3 | Extra main lead wire 2.5 mm 4 core round Copper cable for providing the power supply from the indoor unit to the outdoor unit for split AC. |
| 4 | Extra main lead wire 2.5 mm 3 core round Copper cable for providing the power supply from the Stablizer to indoor unit split AC. |
| 5 | S/F Automatic Voltage stabilizer 5 KVA voltage range140V to 280V for 2.0 Ton A.C |
| 6 | S/F Automatic Voltage stabilizer 4 KVA voltage range140V to 280V for 1.5 Ton A.C |
| 7 | SITC of Suction/Discharge both copper pipe line in Split A.C. unit 1.5 ton capacity including brazing nitrile, rubber insulation 6mm thick class 'O' etc complete 1/4\\" & 1/2\\" |
| 8 | SITC of Suction/Discharge both copper pipe line in Split A.C. unit 1.8/2.0 ton capacity including brazing nitrile, rubber insulation 9 mm thick class 'O' etc complete 3/8\\" & 5/8\\" |
| 9 | S/F of heavy duty PVC Plastic breided 20 mm O.D. Flxiable pipe for condensed water drain with clipping accesories complete |
| 10 | S/F of M.S. Angle iron mtg. Bracket for outdoor unit with antirust paint. |
| 11 | S/f of M.S angle iron Cage for protection of outdoor unit from animal / theft LxWxH 1300X600X1200 MM |
| 12 | Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required for AC |
| 13 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 14 | S/L of 16 sqmm 2 core Al conductor pvc insulated armoured served sheathed cable 1100 V grade. Complete in all respect. |
| 15 | S/L of 25 sqmm 3.5 core Al conductor pvc insulated armoured served sheathed cable 1100 V grade. Complete in all respect. |
| 16 | S/L of 35 sqmm 3.5 core Al conductor pvc insulated armoured served sheathed cable 1100 V grade. Complete in all respect. |
| 17 | S/L of 120 sqmm 3.5 core Al conductor pvc insulated armoured served sheathed cable 1100 V grade. Complete in all respect. |
| 18 | S/L of 185 sqmm 3.5 core Al conductor pvc insulated armoured served sheathed cable 1100 V grade. Complete in all respect. |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 * 185 sq. mm (57mm) |
| 20 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 * 120 sq. mm (45mm) |
| 21 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 * 35 sq. mm (32mm) |
| 22 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 * 25 sq. mm (28mm) |
| 23 | Supplying and fixing 6 way , Double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) |
| 24 | Supplying and fixing 8 way , Double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) |
| 25 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 4 way (4 + 12), Double door |
| 26 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 27 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 28 | Supplying and fixing 100 Amp rating, four pole, 415 V, MCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 29 | Supplying and fixing 63 Amp rating, four pole, 415 V, MCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 30 | Supplying and fixing 40 Amp rating,Doubler pole, 415 V, MCCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 31 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for 4 way TPNDB triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 32 | Supply & Errection of factory fabricated & wired metal clad dust and vermin proof floor mounting, panel M.S. channel base with bottom etc.complete in all respects. Incoming-400 Amp /415Volt MCCB- 1 No,Outgoing- 200 Amp-1 Nos., 100 Amp-2 Nos 63 Amp-1 Nos Nos. |
| 33 | Supply & Errection of factory fabricated & wired metal clad dust and vermin proof floor mounting, panel M.S. channel base with bottom etc.complete in all respects. Incoming-200 Amp /415Volt MCCB- 1 No,Outgoing- 63 Amp-3 Nos |
| 34 | Supply & Errection of factory fabricated & wired metal clad dust and vermin proof floor mounting, panel M.S. channel base with bottom etc.complete in all respects. Incoming-100 Amp /415Volt MCCB- 1 No,Outgoing- 63 Amp-2 Nos |
| 35 | Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 36 | Providing and fixing 25 mm X 5 mm G.1. strip on surface or in recess for connections etc. as required. |
| 37 | Providing, laying and fixing 100 mm dia G.l. pipe (medium class) in ground complete with G.l. fittings including trenching (75 cm deep)and re-filling etc as required. |
| 38 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 39 | S/F of shock Treatmemt Chart (prescribed under IE rules) |
| 40 | S/F/I of Rubber matting1800x900x12 mm tested and chequred Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender