Tender for Provn Of R , Hard Standing, Firing Point Interlocking Tiles And High Mast Light At Mil Stn Kota.
BOQ
| Sl. No. | Item Description |
| 1 | M & L for rough dressed sand stone slab flooring, 25 mm thick, laid dry but jointed and pointed in cement mortar (1:3) complete all as specified and as directed. |
| 2 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 4 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | M & L for cement concrete in surface channels and drains in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 6 | M & L for walling (curved on plan to a mean radius exceeding 6 metre) of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:6) complete all as specified and as directed. |
| 7 | M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 8 | Extra over stone walling of lime or sand stone for hammer dressing to face stones and dressing of face beds and joints with maximum depression of face from straight edge held against the dressed surface not exceeding 40 mm, of random rubble walling, uncoursed or brought upto course complete all as specified and as directed. |
| 9 | Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 10 | Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 11 | M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed. |
| 12 | M&L for preparing newly plastered walls surfaces and applying two coats of cement base paint over and including a coat of suitable primer complete all as specified as mentioned in note of the item and directed by Engineer-in-Charge.Note :- Steps to be followed for cement base paint :-Colour scheme of cement base paint passed by GE.(a) Curing the newly plastered surface of wall by spray gun. (b) Applying one coat of primer.(c) applying one coat of cement base paint(d) curing of surface by spray gun(e) Applying second coat of cement base paint after that curing of surface by spray gun. |
| 13 | S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. |
| 14 | M & L for Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 15 | M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 16 | M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. |
| 17 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 25 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed. |
| 18 | Providing and laying at or near ground level factory made kerb stone of any size, top bullnosed shape, made of M-25 (Design Mix) grade cement concrete, in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 19 | M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 20 | Excavating over areas not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed. |
| 21 | M & L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 22 | M & L for hardcore (broken stone or boulders) of gauge exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 23 | M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 24 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed. |
| 25 | S & F 75mm dia PVC(SWR) single socketed soil waste pipes in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed. |
| 26 | Forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., not exceeding 1.5 m high from base complete all as specified and as directed. |
| 27 | Supply only high density polyethylene pipe (HDPE) (DWC) of pressure rating PN 8 (SDR 17), material grade PE 100and nominal diameter 90 mm including all fittings and fixtures for insertion into horizontal boring/ floor/ wall with necessary fixing arrangements as in cable protection complete all as specified and directed. |
| 28 | Designing, supplying, erecting, installing, testing and commissioning hot dip galvanized polygonal cross section, 16 meter high, bottom dia 410 mm, top dia 150 mm high mast shaft/ pole including lantern carriage to fix 8 Nos of flood light fitting in symmetrical arrangement, junction box, lowering & raising mechanism, winch, head frame, stainless steel wire rope, cable, power tools, lightning finial, aviation light, earthing terminal, feeder pillar, 1 HP, 3 phase motor, both motorises and manual mechanism, mounting base plate 560 mm X 560 mm X 25 mm built in, foundation bolt M 24 X 850 mm including designing for dead load, live load, wind load, seismic load as per the relevant Indian Standards, erecting by making foundation using M25 (Design Mix) concrete using 20 mm nominal size crushed stone aggregate, TMT bars for safe bearing capacity of 5 tonne per square metre complete all as specified and as directed. (Note : Aviation light, Feeder pillar shall be measured and paid for separately.) |
| 29 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 30 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 31 | S & F flood lights nominal 170 watt luminaire with aluminium pressure die cast housing with pure polyester powder coated, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in electronic LED driver (APFC) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, beam angle of 120⁰ clear, CW available CCT of 5700⁰K, power factor of minimum 0.95, total hormonic distortion (THD) less than 10%, colour rendering index greater than 70, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 32 | S&F LT pillar box 60x50x35cm powder coated, outsdoor type, 3 mm thickness comprising of timer switch using Power contactor 32 Amps, (1-NO Each) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 Pole 32 Amps 01 no, MCB SP 6Amp -08 Nos, C-range, ON/OFF indicator all prewired and making provision for fixing incoming & outgoing cables including suitable size aluminium bus bar complete all as specified and directed. |
| 33 | S & F of single dome low intensity 10 Watt LED type Aviation Obstruction Light, die-cast aluminium housing with red polycarvonate dome, IP 65 grade with integral driver & operating voltage 100-270V complete all as specified and directed. |
| 34 | S & F 4 SQMM 12 Core PVC insulated and FR, PVC sheathed , copper conductor ( flexible) industrial cable including proper fixing arrangement 1100 volt, conformimg to IS 694 complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender