Tender for Construction of 10 Bedded Hospital At 9Th Bn Itbp Lohitpur (Ar.P)

BOQ

Name of Work:- C/o 10 Bedded hospital at 9th Bn ITBP Lohitpur (Ar.P)
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, low height vegetation, trees and saplings of girth up to 30 cm (measured at a height of 1m above ground level) and removal of rubbish up to a distance of 50m.
2Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge
3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (IN CEMENT MORTAR)
4PROVISIONAL SUM for the shifting/relocation of existing electrical or telephone utility poles and lines traversing the site. Includes all liaison work, official application fees, payment of Departmental Demand Notes, and any associated minor civil dismantling/refilling. (Note: Payment to the contractor shall be strictly as per actual official receipts + 3 % liaison percentage).
5Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting,unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
6Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all kind of soils
7Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (tenches and plinth, porch ramp, septic tank soak tank etc)
8Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
9Providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment along the external wall perimeter, foundation trenches, and plinth (using Chlorpyrifos 20% EC).The contractor shall execute treatment strictly as per IS 6313 (Part-II) in three stages:Stage 1 – Trench Bottom: After excavation and leveling, and before PCC, spray the trench base and sides uniformly @ 5 L/sqm.Stage 2 – Vertical Faces: During backfilling, treat soil in contact with substructure/retaining walls by rodding and pouring emulsion @ 7.5 L/sqm of vertical surface.Stage 3 – Plinth Top: After compaction and before floor PCC, make 50–75 mm deep holes at 150 mm grid and apply emulsion to saturate soil @ 5 L/sqm.Measurement is base on plinth area of trenches not the developed surface area.Treatment must be executed using approved, ISI-marked Chlorpyrifos 20% EC (or equivalent approved), diluted to a 1% concentration (1 part chemical to 19 parts water).
10Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) all works upto plinth level (Used for: The 100 mm bed under the footings, and the 150 mm strip bed under the foundation brick wall)
11Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. minimum thickness at outer edge 75mm
12(For the shallow footings, pedestals, and heavy plinth beams required in Zone V)Providing and laying in position ready mixed or site batched design mix M30 cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Concrete of M30 grade with minimum cement content of 350 kg /cum
13(For columns,beams, roof slabs, staircases, ). Providing and laying in position ready mixed or site batched design mix M30 cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete. All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum
14chajja and lintels :- Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 12.5 mm nominal size derived from natural sources).
15(Septic Tank Base Slab, Top Slab, Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works upto plinth level 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum
16(Kitchen, Pharmacy countes M20)Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 12.5 mm nominal size derived from natural sources).
17Providing and laying Reinforced Cement Concrete 1:1.5:3 for continuous Sill Bands and Lintel Bands (100mm thick) in masonry walls as per seismic design requirements. excluding the cost of centering, shuttering, finishing and reinforcement Continuous bands must run through all load-bearing and partition walls. Formwork and steel reinforcement will be measured separately under Section 2.0. ACC, Ambuja, UltraTech, Dalmia or Equivalent as approved by EIC
18(For RCC PEDESTALS ). Providing and laying in position ready mixed or site batched design mix M30 cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete. All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cumExecution Notes:1.Pedestals shall be fixed to RCC slab/beam only and shall not rest on waterproofing screed or masonry/parapet wall.2.Pedestals shall be placed generally at 1200 mm c/c preferred and 1500 mm c/c maximum, with additional pedestals at corners, ends, junctions and change of direction.3.Pedestal height shall vary as per drawing to achieve the approved sloping roof profile.4.Base of pedestal shall be properly sealed and integrated with terrace waterproofing to avoid leakage.5.Top of pedestal shall receive embedded plate / anchor bolts / base plate fixing arrangement as per MS frame detail.
19Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450 mm internal dimensions
20Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete.
21Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
22Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
23Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform and window chajjas (sunshades) including the drip course/groove.
24Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level :- Thermo-Mechanically Treated bars of grade Fe-500D or more.
25Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level : Thermo-Mechanically Treated bars of grade Fe-500D or more.( Includes reinforcement for chajjas securely anchored into the lintel bands as well as kitchen counter slab)
26(FOR RCC PEDESTALS)Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level : Thermo-Mechanically Treated bars of grade Fe-500D or more.( Includes reinforcement for chajjas securely anchored into the lintel bands as well as kitchen counter slab) Pedestal bars shall be dowelled into RCC slab/beam only, not into screed, waterproofing, brickwork or parapet.Dowels shall be fixed with approved chemical anchors, with embedment depth as per structural design/manufacturer’s specification.Pedestal reinforcement shall be coordinated with MS base plate and anchor bolt locations to avoid clashes.Embedded anchor bolts, if used, shall be fixed with a template to maintain line, level and spacing.If bolts are fixed after casting, sufficient clear concrete zone shall be kept for drilling and anchoring.MS base plates shall be fixed only after concrete gains required strength, using approved anchor bolts/chemical anchors with washers and locking nuts.
27Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
28Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand).Bricks shall be soaked in water for at least 12 hours before use. Joints shall not exceed 10mm in thickness and shall be raked out to a depth of 15mm while mortar is green. RCC bands at sill and lintel levels are mandatory for Seismic Zone V. Grade-A red clay bricks or Equivalent as approved by EIC
29Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
30(Slate Cladding base)15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
31(HPL Cladding base and others)15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
32(Septic Tank Internal)20 mm cement plaster 1:3 finished with floating coat of neat cement
33Extra for providing and mixing water proofing material in cement plasterMwork in proportion recommended by the manufacturers.
34Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm plaster
35Chicken Wire Mesh at RCC AND MASONRY Junctions:- Providing and fixing 24-gauge GI chicken wire mesh (or alkali-resistant fiberglass mesh) centered over the junction of RCC structural members and masonry walls before plastering. The mesh shall have a minimum width of 150mm (overlapping 75mm on each side of the joint) and be nailed/stapled securely to prevent thermal and shrinkage cracks in the external plaster.
36Underside of balconies, chajjas, and porch slabs PLASTER (12 MM) :- Providing and applying 12mm thick cement plaster in single coat on RCC ceilings and the soffits of chajjas/weather sheds using cement mortar 1:4 (1 cement : 4 fine sand). The rate includes hacking the RCC surface, applying neat cement slurry for bonding, curing, and scaffolding. (Note: The 15x15mm drip course at the edges shall be measured and paid separately under its respective Rmt item).
37Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
38Extra for Integral Waterproofing Compound (Mixed in Plaster):- (Extra over base item of cement plaster) Providing and mixing integral liquid waterproofing compound of approved make (conforming to IS: 2645) in the cement mortar for external wall plastering and chajja soffits. The chemical shall be mixed in the exact proportion recommended by the manufacturer (typically 200ml per 50kg bag of cement). The rate includes the cost of the chemical and the extra labor for homogeneous mechanical mixing. Dr. Fixit (Pidiproof LW+), Fosroc (Conplast WL), Sika (SikaCim), Pidilite or equivalent as approved by EIC
39Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level: Cement mortar 1:4 (1 cement : 4 coarse sand).
40Extra for providing and laying 2 Nos. 6mm dia. M.S. bars at every third course of half-brick masonry (Item 6.13.2). The rate shall include straightening, cutting, and placing the bars in the mortar bed with a minimum 25mm side cover.Anchoring: The rate also includes drilling and anchoring the ends of the bars (minimum 50mm deep) into adjacent RCC columns/shear walls using neat cement slurry or approved chemical grout to ensure structural continuity.Note: Measurement shall be based on the total surface area of the 4.5\\" wall where reinforcement is provided. TATA Tiscon, JSW Neosteel, SAIL or equivalent as approved by EIC
4112 mm cement plaster of mix 1:6 in fine sand (non wall tiled area)
42Entrance Porch & Stairs (Granite) :- Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. completeat all levels. Joints to be filled with matching epoxy resin/pigment and machine-polished to a mirror finish. Premium Granite (Jet Black, Steel Grey, P White or Tan Brown) or Equivalent as approved by EIC
43STAIRS: Providing rounded/half-bullnose molding for treads, and 3mm deep anti-skid groove lines (3 nos.) near the nosing. Joints to be filled with matching epoxy resin/pigment and machine-polished to a mirror finish. Premium Granite (Jet Black, Steel Grey, or Tan Brown) or Equivalent as approved by EIC
44General Areas, Corridors & Wards (Vitrified Tiles)Providing and laying Double Charged Vitrified tiles in floor 600 X 1200 MM (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Once laid, the granite and tiles must be covered with some protective covering like 2mm thick foam sheets and hardboard until the project is handed over
45O.T. & ICU (Large Format Vitrified - Zero Spacing)Providing and laying Double Charged Vitrified tiles in floor 800 X 1200 MM (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
46Providing and fixing urinal privacy partition / modesty panel made of 18 mm thick gang-saw cut, mirror-polished granite stone slab of approved colour, shade and texture, size approximately 900 mm high × 450 mm projection or as per drawing, with all exposed edges machine polished and chamfered, fixed to wall with heavy-duty SS 304 brackets/cleats, SS screws, anchor fasteners/chemical anchors, epoxy, sealant at wall junction, cutting, dressing, making holes/grooves, cleaning and finishing, complete in all respects as directed by Engineer-in-Charge. Once laid, the granite and tiles must be covered with some protective covering like 2mm thick foam sheets and hardboard until the project is handed over. Kajaria (The Slab), Somany (Max), Simpolo or equivalent as approved by EIC
47Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)
48Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levelsGranite slab area up to 0.50 sqm
49Granite slab area over 0.50 sqm
50O.T. & ICU: Modular Cleanroom Ceiling:- Providing and fixing a modular, non-particulate, clip-in metal ceiling system. Panels shall be 600x600mm, made of 0.7mm thick powder-coated galvanized steel with an anti-bacterial coating. The system must be \\"walkable\\" or supported by a heavy-duty GI grid to allow for maintenance of above-ceiling services. All joints to be sealed with medical-grade silicone. The rate includes cutouts for surgical lights, HEPA filters, and pendants. ceiling-to-wall junction to have R-50 aluminum coving we specified for the floors and walls to ensure no 90-degree corners exist. (Rate is all inclusive) GMP, Nicomac, Lindner, Armstrong (Clean Room range) OR equivalent as approved by EIC
51Corridors & Wards: Perforated Metal Lay-in Ceiling :- Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber acoustical fleece. ensure T-grid frame is powder-coated in the exact same RAL color code as the metal tiles so the grid blends seamlessly (Armstrong (MetalWorks Perforated), Hunter Douglas, Saint-Gobain, USG Boral OR equivalent as approved by EIC.)
52OPDs & TOILETS:- fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)( Saint-Gobain (Gyproc), USG Boral. OR equivalent as approved by EIC.)
53Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
54(Waterproofing wall and floor) Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of bathroom floor and walls upto 300mm height in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particleswith wire brushes, complete in all respect as per the direction of Engineerin-Charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
55(Door chaukhat)Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made Frame size 45 x 85mm Frames to be installed after wet trades (plastering) are complete. Gaps between the masonry and the frame must be sealed with PU foam/sealant. Alstone, Floresta, Hardyplast, Ecoste or Equivalent as approved by Asst. Commandant.
56Providing and fixing Institutional-Grade pre-laminated solid core flush door shutters, 35 mm thick, BWP core. Factory-pressed with 1.0 mm Anti-Microbial / Anti-Bacterial High-Pressure Laminate (HPL). All edges sealed with PUR adhesive. Includes providing a 300x600mm vision panel fitted with 5mm clear toughened glass. Doors must have a clear opening width of minimum 1050mm to accommodate hospital stretchers. (Century Ply, Greenply, Kitply, Duro or Equivalent as approved by Asst. Commandant.)
57Door Shutter :- OPD & Other Areas (out patient Wing D2 & D4):- Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.
58(D3)Providing and fixing factory made single extruded 35mm WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) To be used strictly for internal toilets, bathrooms, and janitor closets where direct water contact is expected. Alstone, Floresta, Hardyplast, Ecoste or Equivalent as approved by Asst. Commandant.
59O.T. DOOR :- Providing, supplying, installing, testing and commissioning manual hermetically sealed single-leaf sliding door for Operation Theatre, size 1500 mm wide × 2100 mm high or as per approved drawing, with 55–60 mm thick factory-made flush door leaf having high-density PUF/PIR/polyurethane insulated core and finished with antibacterial High Pressure Laminate / High Pressure Compact Laminate on both faces in approved shade, complete with double-glazed flush toughened glass vision panel of size 300 mm × 300 mm, aluminium extruded perimeter profile, aluminium extrusion sliding track firmly fixed to wall/support frame, smooth low-noise nylon/polymer roller wheel system with bearings, non-obstructive nylon floor runner guides suitable for trolley movement, EPDM hermetic sealing gaskets, bottom sealing arrangement, reinforced door frame/surround finished with matching laminate and edged with aluminium extrusion, , concealed adjustable fixings for alignment and sealing, elbow-operated handle as approved, lock/latch where required, stoppers, end caps, anchor fasteners, silicone sealant and all required accessories, including fixing, alignment, testing of sliding and sealing action, cleaning and finishing complete in all respects as per manufacturer’s specification, approved shop drawing and direction of Engineer-in-Charge. Fitted with Long-Arm Elbow Levers and Foot Pull brackets (NO D-handles). Door must achieve a positive pressure seal compliant with NABH OT guidelines. Metaflex, Avians, Gandhi Automations, Dorma or Equivalent as approved by Asst. Commandant.
60Lead-Lined Door (For Radiology/X-Ray): Providing and fixing solid wood/metal door shutter laminated with anti-microbial HPL, enclosing a continuous internal core of 2mm thick 99% pure lead sheet. Includes matching lead-lined WPC/Metal frame to prevent radiation leakage. Lead thickness must be certified and tested by AERB guidelines before handover to ITBP. Greenply, CenturyDoors (Lead-Lined Series), Mikasa or equivalent as approved by Assistant Commandant.
61Fire-Rated Door (For Exits & Stairwells): Providing and fixing 120-minute fire-rated steel door comprising of factory-made double skin galvanized steel sheet (min 1.2mm) with rockwool/honeycomb core. Includes fire-rated metal frame, intumescent seal, panic crash bar, and fire-rated hinges.Shakti Met-Dor, Tata Pravesh, Godrej, Navair or Equivalent as approved by Asst. Commandant.
62Providing and fixing 1.2mm thick Stainless Steel (SS 304) Kick Plates (200mm high, full width) at the bottom of patient room/corridor doors, fixed with countersunk SS screws.JINDAL STEEL, SAIL or Equivalent as approved by Asst. Commandant.
63Providing and fixing Stainless Steel (SS Grade 304) heavy-duty D-Type Pull Handles for ward and corridor doors: Size 300 mm x 20 mm.NOT to be installed on OT doors. PULL HANDLES TO BE INSTALLED ON INWARD OPENING SIDE WHILE PUSH PLATE OUTSIDE.Godrej, Dorma, Hettich, Dorset or equivalent as approved by Assistant Commandant.
64Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width above 700 mm), with double speed adjustment with necessary accessories and screws etc. complete. Godrej, Dorma, Hettich, Dorset or equivalent as approved by Assistant Commandant.
65Heavy-Duty SS Hinges: Providing and fixing Stainless Steel (SS 304) 5-Knuckle, 2-Ball Bearing Butt Hinges of size 125x75x3 mm. Minimum 4 hinges per leaf for ward doors (due to the heavy weight of HPL doors). Ball-bearing hinges are mandatory to prevent door sagging over time.
66Providing and fixing SS tower bolts, ISI marked, anodised (anodic Coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeTo be installed on the inactive leaf of double doors and inside toilets.Godrej, Dorma, Hettich, Dorset or equivalent as approved by Assistant Commandant.
67Mortise Locks (Wards & Cabins): Providing and fixing 6-lever heavy-duty Mortise Lock with SS 304 body and SS Lever-Type Handles (not knobs) and matching key escutcheons.Godrej, Dorma, Hettich, Dorset or equivalent as approved by Assistant Commandant.
68Toilet Latches (Indicator Type for Wards): Providing and fixing SS 304 surface-mounted or mortised bathroom latch with a Red/Green Vacant/Engaged indicator on the outside, and an emergency coin-release slot.Godrej, Dorma, Hettich, Dorset or equivalent as approved by Assistant Commandant.
69DISABLED TOILET DOOR RAIL )Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
70Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screwsetc. complete. Twin rubber stopperGodrej, Dorma, Hettich, Dorset or equivalent as approved by Assistant Commandant.
71Providing and fixing heavy-duty Grey Powder-Coated aluminum glazed double-leaf swing door.Description:Providing and fixing heavy-duty aluminum framed glazed double-leaf swing door (equal leaves), without kick/push plates for a minimalist aesthetic.Frame: Extruded aluminum (2.0mm wall thickness) with High-Gloss White Powder Coating (RAL 9016).Glazing: 11.52mm clear laminated safety glass with EPDM gaskets.Hardware: 2 Nos. Heavy-duty concealed floor springs (120kg capacity).2 Sets of Extended length (1200mm) SS 304 D-pull handles (back-to-back).Heavy-duty mortise lock with Euro-profile cylinder and concealed flush bolts for the inactive leaf.Sealant: Perimeter sealing with white weather-grade silicone.Aluminum Systems (Profiles)Premium: Hindalco (Eternia), Jindal, SAIL
72uPVC Sliding Window (Glazing + Fly Mesh) (above 900mm)Providing and fixing factory-made GREY uPVC 3-Track Sliding Window unit. The frame shall be multi-chambered (minimum 2.2mm wall thickness) with three in-built tracks, duly reinforced with 1.6mm (± 0.2mm) thick galvanized mild steel sections.The window assembly shall consist of:Two Sliding Glass Sashes: Fitted with 5mm thick clear float glass, EPDM gaskets, and wool pile weather stripping.One Sliding Mesh Sash: Fitted with SS 304 grade fly-proof wire mesh (0.2mm wire diameter) on a dedicated third track.Hardware & Accessories:Heavy-duty zinc alloy rollers (load capacity 40kg/sash).Zinc alloy touch locks (single-point) on all sashes.Interlocks to ensure air-tightness when closed.All corners to be fusion-welded and cleaned.Perimeter sealing with White Neutral-Cure Silicone over backer rod.(Note: The rate includes all fasteners, SS screws, and drainage hole caps as per manufacturer's specifications. Measurement is per Sqm of the outer frame).( Fenesta, LG Hausys, Rehau, Kommerling, VEKA or approved equivalent)
73uPVC Exhaust-Integrated VentilatorProviding and fixing factory-made GREY uPVC Combined Ventilator unit, multi-chambered profile (min. 2.2mm wall thickness) with 1.6mm G.I. reinforcement.Design: The unit shall be divided into two compartments by a horizontal or vertical uPVC mullion.Exhaust Compartment: One compartment shall be \\"Fixed,\\" featuring a 6mm thick glass with a factory-cut circular hole specifically sized for a standard 150mm/200mm/250mm exhaust fan.Openable Compartment: The second compartment shall be a Top-Hung sash fitted with 5mm thick Frosted/Obscure glass and a fixed SS 304 fly mesh.Hardware: Includes SS 304 friction stays, EPDM gaskets, and a locking cam handle.Sealant: Perimeter and fan-rim sealing with white neutral-cure silicone to prevent vibration and water ingress.The fabricator should provide a small \\"groove\\" or hole in the uPVC profile to pull the electrical wire through, so the wire isn't pinched by the frame during installation. Ensure the hole is cut precisely +5mm larger than the fan body for a snug fit with silicone.
74Hospital-Grade Vitrified Tiling SystemProviding and fixing a complete Hygienic Vitrified Tiling System on brick wall, up to a height of 2100mm (7 ft). The system shall be installed in a seamless sequence comprising the following layers and components:1. Substrate Preparation: 12mm–15mm of cement plaster (1:3 ratio), scratched while wet to create a mechanical grip..2. Adhesive:Type 2 High-Polymer Modified Adhesive, applied with a notched trowel to ensure 100% back-buttered tile coverage.3. Vitrified Tiles:Premium vitrified tiles (600x600mm or 600x1200mm, minimum 9mm thick) with highly water-resistant properties (<0.5% absorption).4. Grouting: 2mm uniform joints maintained with spacers, sealed completely with stain-proof and chemical-resistant 100% Solid Epoxy Grout.Vitrified Tiles :- Kajaria (Eternity), Somany (Duragres), Nitco or equivalent as approved by Assistant Commandant.Adhesive & Grout:- MYK Laticrete, Kerakoll, Fosroc or equivalent as approved by Assistant Commandant.Protection Trims:- Schluter-Systems, Hafele, Genesis or equivalent as approved by Assistant Commandant.Cement :- UltraTech, ACC, Ambuja or equivalent as approved by Assistant Commandant.Note- Trims and edgings are to be in clack color
75External Corner Trim:- Providing and fixing Stainless Steel (SS 304 grade) square-edge tile protection profile for external wall corners. The profile shall be appropriately sized to accommodate 9mm to 10mm thick vitrified tiles. The trim is to be installed concurrently with the tile laying process, with its perforated anchoring leg embedded securely into the Type 2 High-Polymer adhesive bed.
76Flush Wall Plastering :- Providing and applying 30mm thick cement plaster in two coats (backing coat and smooth finish coat) on 4.5-inch half-brick walls above the 7ft tile dado, executed to finish perfectly flush with the aluminum transition profile and tile face below. The rate includes providing and securely fixing galvanized chicken wire mesh over the masonry prior to plastering (or embedded within the backing coat) to prevent shrinkage cracks in the thick plaster build-up. The work includes all materials, labor, scaffolding, curing, and surface preparation to receive final paint finishes, complete in all respects. (Establish the Guide: Fix an aluminum transition trim directly to the bare brick at exactly 7 feet to serve as the master depth reference for the entire wall.Execute Top Section (Plaster): Install wire mesh with screws on raw brickwork and apply a 30mm, two-coat plaster system above the trim. Screed it so it finishes completely level with the trim's top edge.Execute Bottom Section (Tile): Install tiles below the trim using high-polymer adhesive. Adjust the adhesive bed thickness until the tile face sits perfectly flush with the trim's bottom edge, ensuring a completely flat wall top to bottom.)
77TOILET WALL TILING :- Providing and laying approved Vitrified wall tiles (minimum 8mm thickness, Size 300 x600 mm) for toilet dado up to 7ft height on prepared wall surfaces using high-polymer modified water-resistant tile adhesive. The work includes pointing joints with matching waterproof epoxy grout.The work includes all materials, labor, specialized cutting for plumbing points, bottle traps, and health faucets, and final curing, complete in all respects.Tiles: Kajaria (Eternity), Somany (Gres), Johnson, Nitco. or equivalent as approved by Assistant Commandant.Adhesive/Grout: Roff (Vitreofix), Laticrete (335/290), Sika, Fosroc. or equivalent as approved by Assistant Commandant.
78Providing and laying anti-skid (matte finish) vitrified floor tiles of size ( 600mm x 600mm) of approved make and shade in toilets, pantries, and wet areas. The tiles shall be laid over a 20mm thick cement mortar bed (1:4) and fixed with neat cement slurry or high-polymer adhesive. The rate is inclusive of providing 2mm to 3mm uniform spacers, finishing the joints with matching 100% waterproof epoxy grout, cutting/grinding around floor traps, EWC waste pipes, and ensuring a strict gradient (slope) towards the floor drains. The work includes all materials, labor, specialized core cutting, and final chemical cleaning, complete in all respects.A minimum slope of 1:100 (or 10mm drop for every 1 meter) must be maintained towards the nahani trap/floor drain to ensure zero water ponding.Kajaria, Somany, Nitco, Johnson (Anti-Skid Vitrified Range). or equivalent as approved by Assistant Commandant.
79Providing and applying premium anti-bacterial and anti-fungal acrylic emulsion paint (hospital-grade) of approved shade on interior plastered surfaces. The rate includes thorough surface preparation, application of two coats of acrylic wall putty to achieve a plumb and smooth surface, sanding, one coat of anti-fungal cement primer, and two or more coats of the finish paint. The work includes scaffolding, meticulous masking of adjacent aluminum trims and tiles, and final cleaning, complete in all respects. (OPD, Toilets, Above tiling, wards etc) Paint and putty must strictly not be applied until the plaster is fully cured and bone-drySurface Preparation: The plastered surface must be wire-brushed to remove loose sand particles and efflorescence before putty application.Putty Sanding: After the second coat of putty, the surface must be sanded with fine-grit emery paper (No. 320 or 400) and illuminated with a halogen lamp placed parallel to the wall to check for undulations before the primer is applied.Masking: The aluminum transition trims and corner guards must be tightly masked with painter's tape before any putty or paint is applied to prevent stubborn stains on the metal finishes.
80Anti-Bacterial Epoxy/PU Coating (O.T., ICU, ISOLATION WARD)Providing and applying a seamless, multi-layer medical-grade Epoxy/PU wall coating system for O.T. and ICU interior plastered walls, comprising:Surface Preparation: Fine sanding of plaster and application of high-penetration epoxy primerLeveling Layer: Solvent-free epoxy putty to remove undulationsIntermediate Coat: High-build epoxy for strength and impact resistanceFinish Coat: Two coats of aliphatic PU or silver-ion epoxy, delivering a high-gloss, antibacterial, and chemical-resistant surfaceIncludes 50mm radius (R-50) epoxy covings at all wall-wall and wall-floor junctions for seamless, dust-free transitions.All work to comply with healthcare hygiene standards.Coving Requirement: Provide smooth, rounded epoxy coving at all wall junctions; sharp 90° corners not permitted.Moisture Control: Application only after 30mm plaster curing (21–28 days) with moisture content ≤ 4–5%.Surface Finish Quality: Substrate (plaster/putty) to be finished to near mirror smoothness to avoid imperfections under high-gloss and surgical lighting.(Asian Paints (Apco Flor / Royale Health Shield), Berger (Epilux), Sika (Sikafloor/Sikagard), Fosroc (Nitoflor), Dr. Fixit (Pidilite). or APPROVED EQUIVALENT)
81Wall-Mounted Aluminum Handrail / Crash RailProviding and fixing wall-mounted heavy-duty extruded aluminum handrail/crash rail of approved profile, width, and finish (anodized or powder-coated). The item includes continuous aluminum mounting brackets/retainers fixed firmly to the masonry/concrete wall using heavy-duty mechanical anchors at specified intervals. The work is inclusive of providing and fixing all matching molded end caps, internal/external corner returns, and joint covers. The rate includes all materials, labor, exact level alignment, and cleaning, complete as per architectural drawings and site requirements. 1. To be mounted at 900mm from F.F.L. 2. Mounting brackets must be securely anchored to the masonry every 600mm to 800mm maximum. 3. All exposed ends must be closed with manufacturer-supplied molded end caps. At corners, the rail must be joined using specific internal/external corner pieces—no sharp, open miter cuts should be exposed to pedestrian traffic. CS Group (Acrovyn), Arfen Or Equivalent as approved by Assistant Commandant
82Heavy-Duty Aluminum Corner GuardsDescription: Providing and fixing heavy-duty extruded aluminum surface-mounted corner guards (50mm x 50mm, minimum 2mm thick) on finished external wall corners. The guards to be of approved anodized or powder-coated finish, securely fixed over the painted plaster using high-strength construction adhesive (Sikaflex or equivalent) or countersunk stainless steel screws with PVC wall plugs. The rate includes all materials, labor, exact cutting to height, ensuring a perfectly plumb installation, and removal of protective films.Height = 1200 mm from F.F.L.
83STAIRCASE RAILING AND HANDRAILS :- Providing and fixing Stainless Steel (Grade 304) railing for the staircase. The assembly shall consist of a 50mm diameter SS tubular handrail (16 gauge/1.5mm thick), supported by 40mm diameter SS vertical balusters spaced at maximum 1000mm intervals. The railing shall include 3 to 4 rows of 20mm diameter SS horizontal mid-rails. The rate includes all argon-arc welding, grinding, buffing, and polishing to a seamless matt/satin finish. Installation includes anchoring the balusters into the granite/concrete using heavy-duty anchor fasteners and covering the base with SS flange caps.Jindal Stainless, SAIL, Tata. or equivalent as approved by AC
84Hospital Ramp Railing (Double-Handrail System)Providing and fixing a specialized Stainless Steel (Grade 304) double-handrail system for the hospital wheelchair ramp. The top handrail shall be fixed at 900mm height, and a secondary continuous lower handrail fixed at 750mm height (to assist wheelchair users and children). Fabricated using 50mm dia SS pipes for handrails and heavy-duty 40mm/50mm SS balusters. The rate includes continuous argon welding with zero sharp edges, seamless bends, buffing to a matt finish, and secure mechanical anchoring to the ramp slab.
85MS Structural Framework for Sloping Floating Roof BandProviding, fabricating and fixing MS structural framework for projected sloping floating roof band over RCC pedestals, using MS rectangular hollow sections for main sloping members and secondary purlins, MS base plates, cleats, stiffeners and bracing members, complete in required slope, projection, line and level as per approved architectural and structural drawings. The work shall include fixing of base plates to RCC pedestals with approved anchor bolts / chemical anchors, cutting, welding, drilling, grinding, alignment, levelling, anti-corrosive treatment with zinc-rich / epoxy primer and finish paint, scaffolding, staging, lifting, labour, tools and tackles, all complete as per approved shop drawings and direction of Engineer-in-Charge. The MS framework shall include necessary perimeter edge members and secondary supports required for fixing 200 mm deep ACP fascia band and underside soffit ceilingDesign intent:To create the structural skeleton for the raised, floating and sloping roof-band appearance, with all primary loads transferred to RCC pedestals / RCC structural members only and not to masonry/parapet wall.1.MS framework shall be fixed to RCC pedestals / RCC structural members only.2.Masonry/parapet wall shall not be used as the primary support.3.Framework shall follow the approved slope profile, with higher front edge and lower rear edge as per drawing.4.Base plates shall be properly seated and anchored to RCC pedestals.5.Purlins and bracing shall be provided to prevent sagging, vibration and twisting.6.All MS members and welds shall receive anti-corrosive treatment before covering with roofing/fascia/soffit finishes.
86Structural M.S. Sub-Framework for Plinth Base Band (UPTO 900MM) :- Steel work in built up tubular round, square or rectangular hollow tubes etc., trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolting with special shaped washers etc., complete.1. Sections shall not be fixed directly to RCC / Masonry. Use of L Cleat is mandatory.2. All sections shall be painted two coats of enamel post priming coat to ensure anti- rust properties.
87Enamel Paint over M.S. Framework :- Providing and applying two or more coats of synthetic enamel paint of approved brand and manufacture over primed MS hollow tube cladding sub-frame, including cleaning, surface preparation, painting all exposed faces, edges, welded joints, cleats and brackets, complete to give an even shade and finish as per direction of Engineer-in-Charge.
88Plinth Base Slate / Quartzite Stone Cladding up to 900 mm Height with FCB Substrate FRONT WING:-Providing and fixing a rugged-finish natural quartzite/slate stone cladding to create a premium base band, engineered to sit exactly 25 mm proud of the adjacent HPL facade. The rate is composite and includes the installation of a lightweight hybrid substrate system to achieve the required architectural projection without excessive masonry dead-load.The system execution shall strictly comprise:Substrate Boarding: Providing and fixing 16 mm thick heavy-duty, exterior-grade Fiber Cement Board (FCB) (IS 14862 type A or equivalent) screwed to the primary sub-framing (framing paid under a separate item) using SS 304 countersunk winged self-drilling screws.Board Jointing: Leaving 3 mm to 5 mm expansion gaps between FCB panels, completely filled with exterior-grade Polyurethane (PU) sealant.Stone Specification: 20 mm to 25 mm thick, machine-cut / hand-dressed natural quartzite/slate stone (approved shade such as Himachal Golden or Autumn Brown).Bonding Agent: Fixing the stone panels to the FCB substrate using a premium, high-strength, polymer-modified cementitious stone adhesive (conforming to IS 15477 Type 3 or Type 4), applied using the notch-trowel method.Finishing: Includes surface preparation, edge dressing, corner mitering/returns, leveling, pointing/sealing of joints, scaffolding, staging, and final cleaning. Complete in all respects up to the specified heights as per elevation drawings and the direction of the Engineer-in-Charge.Design intent:To create a durable rugged stone base band below the HPL façade, with the finished quartzite/slate cladding face maintained approximately 25 mm proud of the finished HPL façade face, giving the façade a layered, premium and grounded appearance.1.The penetrating sealer must be applied only when the stone and joints are completely dry (minimum 48 hours after fixing) to avoid trapping moisture.2.Stone shall be 20–25 mm thick natural split-face / rugged-finish quartzite, preferably Himachal Golden Quartzite / Autumn Brown Quartzite or approved equivalent.3.Cladding shall be provided up to 900 mm height from approved finished plinth / external floor level as shown in drawings. 4.Finished stone face shall project approximately 25 mm beyond the finished HPL façade face.5.At all external corners (especially on the porch columns), the slate must either be perfectly mitered at 45 degrees, or a \\"quoin\\" (interlocking) pattern must be used so that the grey/black core of the natural stone is not exposed as a raw, ugly edge.(Adhesive/Sealer): Laticrete, Roff, Fosroc, Dr. Fixit. or equivalent as per AC
89Porch Column And BackWing Plimth Base Slate Cladding (Direct Application):- Up to 2700 mm height on Porch Columns & Back Wing, Middle Wing.Providing and fixing natural split-face / rugged-finish quartzite stone cladding (20–25 mm thick) applied directly over prepared plastered masonry / RCC column surfaces. Rate includes thorough mechanical hacking/roughening of the RCC surface for mechanical key, applying bonding slurry, and fixing the stone using premium exterior-grade polymer-modified cementitious adhesive (IS 15477 Type 3/4) via the double-buttering method. Includes specialized 45-degree corner mitering or quoin interlocking at column edges, pointing/sealing of joints, scaffolding, staging, and final cleaning, complete in all respects. (Note: No FCB or aluminum framing to be used or paid under this item).
90Transition Detail: Stone Capping / Coping :- Providing and fixing natural stone capping (matching Sandstone, minimum 18mm thick and 75mm ) at the horizontal transition line between the stucco finish and the stacked stone cladding. The capping stone to be machine-cut with a slight outward slope on top to shed rainwater, featuring an exposed half-round or full-bullnose edge molding. The rate includes providing a continuous minimum 6mm deep half-round drip groove on the underside of the projection to prevent water from running back into the stone face. Fixed using high-polymer modified mortar/adhesive and sealed at the wall junction with exterior-grade polyurethane (PU) weather sealant.The PU sealant at the junction between the capping and the stucco wall must be applied after the stone has fully cured (min 24 hours) to accommodate any minor initial shrinkage.(Sealant): Sikaflex, Dow Corning, McCoy Soudal.
91Structural Aluminum Sub-Framework:- Providing and fixing structural aluminum sub-framing for an exterior rear-ventilated rainscreen cladding system. The framework shall be engineered to support an architectural grid of 1220 mm x 1220 mm and must be executed in true line, level, and plumb. Measurement and payment shall be based on the actual finished weight of the aluminum profiles and brackets installed on-site.The system execution shall strictly comprise:Material: Extruded aluminum alloy framing system (minimum grade 6063-T5/T6).Vertical Joint Profiles: Continuous structural Aluminum 'T' profiles (100 mm x 50 mm x minimum 2.0 mm thickness) positioned behind all vertical panel joints.Intermediate Vertical Supports: Continuous hollow aluminum square/rectangular tubes (50 mm x 50 mm x minimum 2.0 mm thickness) positioned at 610 mm center-to-center between the T-profiles to support the panel centers.Horizontal Joint Baffles: Flat aluminum flashing strips (100 mm x minimum 1.5 mm thickness) tacked horizontally across the front face of the vertical profiles behind all horizontal panel joints. The use of horizontal hollow tubes is strictly prohibited to maintain an unobstructed 50 mm vertical ventilation cavity.Anchorage: Framework fixed to RCC/masonry using heavy-duty MS hot-dip galvanized or Aluminum L-brackets, anchored with marine grade SS 304 anchor fasteners/chemical anchors of appropriate pull-out strength. Includes provision of 5 mm thick thermal isolation pads (EPDM/HDPE) behind brackets to prevent bi-metallic corrosion.
92Providing and fixing exterior grade High Pressure Laminate (HPL) façade cladding system, Providing and fixing an exterior Rear-Ventilated Rainscreen Cladding System using 8 mm thick High-Pressure Compact Laminate (HPL) panels (EN 438-6 Type EDF or equivalent) of approved make, color, and texture, installed over the primary aluminum sub-framing (paid under a separate item). Measurement shall be based on the flat exterior surface area of the finished facade.The system execution shall strictly comprise:Panels: 8 mm thick UV-stable, weather-resistant, anti-graffiti exterior grade HPL panels with a minimum core density of ≥1350 kg/m³ and fire-retardant grade (minimum Class B-s2,d0).Grid & Joints: Panels to be CNC cut to achieve a strict 1220 mm x 1220 mm architectural grid. System must be installed as an Open-Joint Rainscreen with uniform 10 mm shadow gaps vertically and horizontally. The sealing of joints with silicone or any other sealant is strictly prohibited.Weather & Acoustic Sealing: Continuous application of heavy-duty 1.5 mm thick black EPDM rubber gasket tape over the entire front face of all aluminum T-profiles, intermediate square tubes, and horizontal strips prior to panel installation, acting as a waterproof rain-shield and vibration damper.Fixing System: Panels fixed to the aluminum sub-frame using exposed SS 304 structural blind rivets (minimum 4.8 mm diameter) with factory-painted/powder-coated heads to match the HPL color perfectly. Installation must include fixed points and sliding points (slotted holes) to accommodate thermal expansion.Finishing: Includes complete cutting, routing, drilling, edge chamfering, and provision of top parapet flashings, closure profiles, and bottom bug-screens to achieve a complete, true-line facade.Subframe design shall be wind-load compliant considering high rainfall and hill-region exposure (Tezu conditions)Minimum cavity of 20–40 mm to be maintained for ventilated façade performanceEnsure drainage path at base and avoid water entrapmentAll aluminium components to have minimum 20–25 micron anodizing / powder coating (60–80 microns)All fasteners exposed to exterior shall be SS 304/316 onlyEdge sealing of HPL panels mandatory to prevent moisture ingressProvide expansion gaps at max 3–4 m intervalsInstallation to follow manufacturer’s façade installation manual strictlyGREENLAM, CENTURY PLY EXTERIA, FUNDERMAX OR EQUIVALENT AS APPROVED BY EIC
93Top Roofing Sheet to Floating Roof BandProviding and fixing pre-painted Galvalume clip-lock metal roofing sheet system over the sloping floating roof band, of approved make such as Tata BlueScope, JSW, Jindal or equivalent, laid to required slope over MS purlins, including concealed clips, compatible fasteners, side laps, end laps, edge flashing, wall flashing, drip flashing, closures, butyl tape, weatherproof sealant, cutting, wastage, scaffolding, staging, labour, tools and tackles, complete as per approved architectural drawings, shop drawings, manufacturer’s specifications and direction of Engineer-in-Charge.Design intent:To provide the primary rain-shedding top surface over the sloping floating roof band, while keeping ACP/HPL limited to fascia, edge band and soffit surfaces only. 1.Sheet shall follow the approved slope profile of the floating roof band.2.Clip-lock concealed fixing system shall be used to minimise exposed screws on the top rain-bearing surface.3.Proper flashing shall be provided at wall/parapet junctions, side edges and drip edges.4.Butyl tape and weatherproof sealant shall be used at laps, joints and flashing junctions.5.If slope drains towards rear/building side, concealed gutter and downpipe arrangement shall be measured separately.HPL/ACP shall not be used as the top rain-bearing surface.
94Concealed Gutter with Outlet Connection to Khurras/as suitableProviding and fixing concealed pre-coated GI / Galvalume sheet gutter to the lower drainage edge of sloping floating roof band, fabricated to required size, profile and slope as per approved drawings, including end caps, stop ends, outlet collars, short rainwater pipe droppers up to khurra location, bends, joints, supports, brackets, rivets/screws with EPDM washers, butyl tape, weatherproof sealant, cutting, wastage, scaffolding, staging, labour, tools and tackles, complete as per approved architectural drawings, shop drawings, manufacturer’s specifications and direction of Engineer-in-Charge.Design intent:To collect rainwater from the sloping floating roof band on all sides and discharge it in a controlled manner through rainwater pipes into khurras / drainage points, without free discharge over façade or soffit.1.Gutter shall be fixed at the lower/rear drainage edge of the floating roof band.2.Gutter shall be laid with proper slope towards outlet collars.3.Outlet collars shall be provided at required intervals and connected through short rainwater pipe droppers to nearby khurras.4.Discharge shall be directed into prepared khurras and not allowed to spill freely over terrace or façade.5.Joints shall be sealed with butyl tape and exterior-grade weatherproof sealant.6.Provide leaf guard / strainer at gutter outlets wherever required.7.Provide overflow scupper / emergency overflow provision where required to avoid backflow into the roof band cavity.8.Gutter shall remain accessible for cleaning and maintenance wherever possible.
95Structural Aluminum Sub-Framework:- Providing and fixing structural aluminum sub-framing for an exterior rear-ventilated rainscreen cladding system. The framework shall be engineered to support an architectural grid of 1220 mm x 1220 mm and must be executed in true line, level, and plumb. Measurement and payment shall be based on the actual finished weight of the aluminum profiles and brackets installed on-site.The system execution shall strictly comprise:Material: Extruded aluminum alloy framing system (minimum grade 6063-T5/T6).Hardware & Fasteners:To RCC (Porch): Heavy-duty mechanical or chemical anchor fasteners (e.g., Fischer, Hilti, or equivalent approved) of minimum 8mm diameter.To M.S. (Chajja): Marine-grade SS 304 / SS 316 bolts, nuts, and spring washers.Joints & Connections: Aluminium cleats and L-brackets of minimum 3mm thickness.Galvanic Isolation (Critical): Minimum 2mm thick EPDM / Neoprene rubber gaskets or heavy-duty bituminous tape applied at all interface points between the aluminium framework and M.S. members to completely prevent bi-metallic/galvanic corrosion.Structural Integrity: Includes all necessary diagonal bracing and grid densification to withstand high-velocity wind uplift and Seismic Zone V forces.
96Grey ACP Fascia / Edge Band to Floating Roof BandProviding and fixing exterior-grade Fire Retardant Aluminium Composite Panel (FR ACP) fascia cladding to the vertical edge / front face / side returns of the projected floating roof band, using minimum 4 mm thick FR ACP with minimum 0.50 mm aluminium skin on both sides and PVDF / FEVE exterior-grade coating in approved grey shade and finish, fixed over aluminium / GI / anti-corrosion treated MS secondary framework, including cleats, brackets, SS 304 screws / rivets / approved concealed fixing system, routing, grooving, folding, edge trims, corner trims, end caps, shadow gaps, uniform groove joints, exterior-grade weatherproof sealant, scaffolding, staging, cutting, wastage, labour, tools and tackles, complete as per approved drawings and direction of Engineer-in-Charge.Design intent:To create the clean grey edge band / fascia appearance of the sloping floating roof overhang and conceal the structural frame, while keeping HPL limited to wall façade only.1.ACP fascia shall follow the approved sloping profile of the floating roof band.2.Visible fascia depth shall be 300 mm.3.ACP shall be used only on the vertical fascia / edge band and returns, not on the top rain-bearing surface.4.All exposed ACP edges shall be folded, sealed or closed with approved trims.5.Adequate expansion gaps shall be maintained between panels.6.Fascia detailing shall not create hidden water pockets behind the sheet.7.Junction with top Galvalume sheet, gutter and ACP soffit ceiling shall be properly coordinated.
97Wooden-Look Louvered Soffit Ceiling to Floating Roof Band:- Providing and fixing exterior-grade wooden-look aluminium louvered soffit ceiling to the underside of projected floating roof band / false sloping roof overhang, using factory-finished powder-coated / sublimation wood-finish aluminium louvers of approved size, shade and profile, fixed over concealed aluminium / GI / anti-corrosion treated MS secondary framework at required spacing, including perimeter channels, runners, cleats, brackets, SS 304 screws / approved concealed clips, end caps, edge trims, shadow gaps, service openings, light cut-outs, scaffolding, staging, cutting, wastage, labour, tools and tackles, complete as per approved architectural drawings, shop drawings, manufacturer’s specifications and direction of Engineer-in-Charge.1.Louvers shall be aluminium wood-finish, not untreated natural wood.2.Louver direction shall preferably run parallel to the longer length of the floating roof band for a cleaner continuous look.3.Secondary framework for fixing louvers shall be included in this item.4.System shall allow concealed ventilation and shall not trap water inside the roof band cavity.5.Light cut-outs / linear light provisions shall be coordinated with electrical layout.6.Exposed screws shall be avoided as far as possible; use concealed clips or neatly aligned SS 304 fasteners.7.Junction with grey ACP fascia band shall be finished with shadow gap / edge trim.
98Fine Sand-Textured Anti-Fungal Elastomeric Exterior Coating above HPLProviding and applying fine sand-textured anti-fungal elastomeric exterior coating system to the painted wall/parapet band above HPL façade cladding, over prepared plastered surface, including surface cleaning, scraping, removal of loose particles, minor crack filling, application of alkali-resistant exterior primer, fine-textured acrylic/elastomeric intermediate coat and minimum two coats of high-performance elastomeric weatherproof exterior paint of approved make, shade and finish, including masking at HPL junction, maintaining clean straight junction lines, scaffolding, staging, labour, tools and tackles, all complete as per approved elevation drawings, manufacturer’s specifications and direction of Engineer-in-Charge.1.Finish shall be fine sand-textured / low-build, not heavy stucco or rough-cast texture.2.Coating shall be anti-fungal, algae-resistant, UV-resistant and suitable for exterior exposure.3.Surface shall be fully cured, dry, sound and free from dust, oil, efflorescence and loose plaster.4.Junction with HPL shall be neatly masked and finished with straight line / approved trim where required.5.HPL cladding, slate cladding, ACP fascia and soffit ceiling shall be measured separately.Asian Paints (Apex Ultima Protek / Apex Durasoft), Berger (Weathercoat Long Life), Dulux (Weathershield) or equivalent as approved by Asst. Commandant
99HPL-Matching Exterior Elastomeric Paint Finish to Back WingProviding and applying HPL-matching smooth matte anti-fungal elastomeric exterior coating system to back / secondary wing external wall surfaces where HPL cladding is not provided, over prepared plastered surface, including surface cleaning, scraping, removal of loose particles, minor crack filling, application of alkali-resistant exterior primer and minimum two coats of high-performance elastomeric weatherproof exterior paint of approved make, shade and finish,to match the approved HPL panel rhythm wherever shown in elevation, scaffolding, staging, labour, tools and tackles, all complete as per approved elevation drawings, colour scheme, manufacturer’s specifications and direction of Engineer-in-Charge.Design intent:To visually integrate the non-HPL back wing with the HPL-clad front façade by matching colour tone, panel rhythm and overall façade language, while using a more economical weather-resistant paint system suitable for high-rainfall and humid conditions.1.Paint shade shall be selected to closely match the approved HPL façade colour.2.Finish shall preferably be smooth matte / low-sheen, not heavy rough texture.3.Coating shall be anti-fungal, algae-resistant, UV-resistant and elastomeric.4.Surface shall be fully cured, dry, sound and free from dust, oil, efflorescence, loose plaster and hollow patches.5.EXCLUSIONS:- HPL corner returns of 1200 mm shall be measured separately under HPL cladding item.Slate/stone cladding base, ACP fascia, soffit ceiling and floating roof components shall be measured separately.
100Floor Expansion Joint Cover (Heavy-Duty / Flush Finish) :- Providing and fixing a heavy-duty, flush-mounted architectural expansion joint cover system for internal floors (suitable for joint widths of 25mm to 50mm). The system shall consist of twin extruded aluminum base frames anchored to the concrete floor using heavy-duty expansion fasteners on either side of the joint. The central gap shall be bridged by a heavy-duty, flexible, and replaceable serrated EPDM / Santoprene rubber insert (flush with the finished tile/granite floor) designed to absorb multi-directional seismic and thermal movement without creating a tripping hazard. The rate includes surface preparation, mechanical anchoring, and coordination with the floor tiling work to ensure a perfectly level finish.CS Group (Construction Specialties), Inpro, Zurn, Vexcolt or approved equivalent
101Internal Wall & Ceiling Expansion Joint Cover:- Providing and fixing an architectural expansion joint cover system for internal walls and false ceilings. The assembly shall consist of surface-mounted or flush-mounted anodized aluminum retainer profiles screwed to the wall/ceiling on both sides of the joint, fitted with a central snap-on aluminum cover plate or a smooth, washable EPDM elastomeric seal (matching the wall color). The system must accommodate a minimum of ±50% joint movement. Complete in all respects including hardware and alignment.CS Group (Construction Specialties), Inpro, Zurn, Vexcolt or approved equivalent
102Roof & External Wall Expansion Joint Cover (100% Weatherproof)- Providing and fixing a fully weatherproof exterior expansion joint cover system for the roof slab and external vertical elevations. The system must include a continuous, heavy-duty impermeable moisture barrier (EPDM membrane) draped inside the joint cavity, topped by an interlocking extruded aluminum capping or flanged rubber seal that sheds rainwater effectively. The rate includes fixing the aluminum flashing to the concrete parapet/wall using weather-resistant SS fasteners and sealing the outer edges with premium UV-resistant polyurethane (PU) sealant to ensure absolute water-tightness under heavy wind-driven rain.
103SS 304 PVD Coated 3D LED ITBP Signage:- Providing and fixing 3D fabricated signage letters/logo made of Grade 304 Stainless Steel (minimum 1mm thick) with a premium PVD (Physical Vapor Deposition) coating in approved finish (Champagne Gold/Bronze). The letters shall be laser-cut to the specified font, with a return depth (thickness) of 2 to 3 inches to create a 3D effect. The rate includes internal illumination using high-intensity, waterproof Samsung/equivalent LED modules for a \\"Halo\\" back-lit effect. The letters are to be mounted on the porch lintel band using hidden SS studs and spacers. The work includes all internal wiring, specialized waterproof LED drivers/transformers housed in a concealed yet accessible weatherproof box, and final connection to the nearest electrical point. Complete in all respects as per the approved architectural typeface and logo design. (12 inch height or as approved by AC) Stencil Template: Contractor shall use a full-scale vinyl stencil to mark the drill holes.
1043D Solid Metal ITBP Insignia (Halo-Lit PVD) Providing and fixing 3D fabricated, single-color ITBP Insignia/Logo of 450mm diameter. The entire emblem (face and returns) shall be precision laser-cut and fabricated from solid Grade 304 Stainless Steel (minimum 1.2mm thick) with a premium PVD coating in approved finish to exactly match the external lettering. The rate includes rear-mounted, high-intensity IP-68 (100% waterproof) LED modules to provide a reverse \\"Halo-Lit\\" silhouette effect against the facade. The work includes mounting the insignia using concealed heavy-duty SS spacer pins (minimum 25mm to 50mm standoff from the wall), concealed weatherproof LED drivers, internal wiring, and structural anchoring. Complete in all respects and executed to the Engineer-in-Charge's approval.Measurement: Billed per Square Meter based on the theoretical square bounding box that encloses the logo's full diameter.Mounting: Anchored using concealed SS spacer pins with a 25mm to 50mm standoff distance from the wall, secured with heavy-duty epoxy chemical anchors.Illumination: LED modules must be strictly IP-68 (fully waterproof/submersible) to survive water pooling in the logo returns.Finish Consistency: The Champagne Gold/Bronze PVD coating must be from the exact same vacuum chamber batch as the external text signage to guarantee zero shade variation.Approved Makes (LEDs/Drivers): GE / Samsung (LEDs), Meanwell (Drivers) or approved equivalent(2 FEET HIGH LOGO)
105WINDOW CURTAINS :- ROLLER BLINDS: Providing and fixing Fiber Plain Foldable Windows Roller Blinds all complete job as per specifications & shade as per directions of engineer in charge. Make: Vista material fabric type roller horizontal pattern plain/ as approved by EICVISTA/MAC OR APPROVED EQUIVALENT
106Modular Room Identification Signage (Wall/Door Mounted):- Providing and fixing modular indoor signage system for room identification (OPDs, wards, cabins, toilets etc.), comprising extruded aluminium profile (flat/curved) with natural silver anodized finish (min. 15 micron), complete with injection-moulded end caps and removable 1.5–2 mm thick anti-glare clear acrylic/polycarbonate front cover, suitable for changeable inserts.Including high-resolution bilingual (Hindi & English) printed graphics on non-tearable synthetic paper/vinyl inserts; fixing with concealed stainless steel screws and nylon wall plugs (adhesive fixing not permitted); complete as per approved signage & wayfinding plan.NO SIGNAGE SHOULD BE LESS THAN 300mm x 150mmCosign, Vista System or equivalent; Acrylic: Perspex, Evonik or approved equiivalent
107Semi-Fowler Hospital Bed with Mattress:- Providing and supplying semi-fowler hospital bed with mattress, manually operated, suitable for hospital ward/private ward/isolation ward use, having MS tubular frame with epoxy powder-coated finish, perforated CRCA/MS sheet top in two/four sections, adjustable backrest operated by smooth crank mechanism, detachable/laminated head and foot panels, provision for IV rod/urine bag hook, side rail provision where specified, mounted on castors , complete with 75 mm to 100 mm thick hospital-grade foam mattress with rexine/PU-coated washable waterproof cover, all complete including transportation, loading/unloading, placing in position and all incidental charges.
108Bedside Locker:- Providing and supplying hospital bedside locker suitable for ward/private/isolation bed use, made of MS powder-coated body with stainless steel top, having one drawer and one cabinet/shutter with shelf, smooth edges, easy-clean finish, rubber shoes/castors as approved, complete including transportation, loading/unloading, placing in position and all incidental charges.1.Body made of MS sheet / CRCA sheet with anti-rust treatment.2.Finished with epoxy powder coating of approved colour and shade.3.Top shall be stainless steel / SS top for easy cleaning and hygiene.4.Approximate size: 400–450 mm W × 400–450 mm D × 750–850 mm H.5.Shall have one drawer for patient belongings/medicines.6.Shall have one lower cabinet with shutter and internal shelf.7.Drawer and shutter shall be provided with smooth handle/knob.8.Edges shall be rounded/smooth and safe for hospital use.9.Shall be provided with rubber shoes / castors as approved.10.Surface shall be easy to clean, corrosion-resistant and suitable for hospital ward use.
109IV STAND:- Providing and supplying IV stand / saline stand, complete with the following specifications:Made of stainless steel SS 304 / chrome-plated MS of approved make.Height-adjustable telescopic vertical rod.Minimum height approx. 1200 mm, adjustable up to approx. 2100 mm.Provided with two / four hooks at top for IV fluid bottles/bags.Stable five-leg / four-leg base with smooth movement.Base fitted with non-rusting castors / rubber shoes as approved.Locking arrangement to hold rod at required height.Smooth, rounded and easy-clean finish suitable for hospital use.Corrosion-resistant and suitable for ward, isolation and post-operative areas.Item shall include transportation, loading/unloading, placing in position, GST, labour, overheads, contractor’s profit and all incidental charges.
110Overbed Table / Patient Food Table:- Providing and supplying hospital overbed table / patient food table, complete with the following specifications:Height-adjustable overbed table suitable for hospital ward, private ward, isolation ward and post-operative ward use.Frame made of MS tubular section / powder-coated steel frame with anti-rust treatment.Table top made of laminated board / ABS / SS top of approved make and finish.Approximate table top size: 750–800 mm × 400 mm.Height adjustable from approx. 750 mm to 1050 mm or as per approved model.Mounted on smooth-moving castors, preferably with locking arrangement.Edges shall be rounded/safe for patient use.Table shall be easy to clean, stable and suitable for serving food, medicines, reading or patient use.
111Attendant / Visitor Chair for Ward Beds:- Providing and supplying attendant / visitor chair for hospital ward/private ward/isolation ward use, complete with the following specifications:Chair suitable for patient attendant / visitor use near hospital bed.Frame made of MS tubular section / CRCA steel, anti-rust treated.Finished with epoxy powder coating / chrome finish of approved shade.Seat and back made of moulded plastic / cushioned rexine / perforated MS sheet as approved.Ergonomic seat and backrest with smooth, rounded edges.Stable four-leg base with rubber shoes.Easy-clean, corrosion-resistant and suitable for hospital environment.
112Bedside Screen / Privacy Screen :- Providing and supplying hospital bedside screen / privacy screen, complete with the following specifications:3-fold or 4-fold folding privacy screen suitable for hospital ward and examination areas.Frame made of MS tubular section / stainless steel / powder-coated steel as approved.Approximate overall size: 1650–1700 mm height × 2400–2450 mm extended length.Provided with washable curtain panels of approved colour and hospital-grade fabric.Curtain shall be removable, washable and replaceable.Mounted on smooth-moving castors with stable base.Hinged folding panels for easy movement and storage.Frame shall be corrosion-resistant, smooth finished and easy to clean.
113NURSE STATION : -Providing and supplying/fixing nursing station counter suitable for 1–2 nursing staff, complete with the following specifications:1.Counter shall be made in modular commercial board / plywood / MDF / pre-laminated board with approved laminate finish.2.Counter size shall be 1800 mm length × 600 mm depth × 1050 mm height.3.Counter top shall be finished with 1 mm thick laminate / post-formed laminated top / solid surface as approved.4.Front fascia shall have clean hospital-grade laminate finish with proper edge banding.5.Counter shall include worktop, modesty panel, drawers, shutters, open shelves and under-counter storage as required.6.Provision shall be made for computer, printer, files, medicine records and nursing stationery.7.Electrical/data cable management shall be provided through grommets, cut-outs or concealed openings.8.Hardware shall include good quality hinges, drawer channels, handles, locks and magnetic catchers wherever required.9.All exposed edges shall be finished with PVC edge banding / laminate edge finish.10.Surface shall be durable, easy to clean and suitable for hospital use.
114Revolving Nurse Chair- Providing and supplying revolving nurse chair, complete with the following specifications:Mid-back revolving chair suitable for nursing station / duty nurse desk use.Seat and back shall be cushioned / mesh / fabric upholstered as approved.Seat height adjustable with hydraulic gas-lift mechanism.Chair shall have revolving mechanism with stable five-star base.Base shall be nylon / chrome-plated / powder-coated metal as approved.Provided with smooth-moving castors suitable for hospital flooring.Armrest may be provided where approved.Upholstery shall be easy to clean and suitable for hospital use.Colour and finish shall be as approved by Engineer-in-Charge.
115Medicine / Record Storage Cabinet for Nursing Station- Providing and supplying medicine / record storage cabinet for nursing station, complete with the following specifications:1.Cabinet shall be made of MS sheet / CRCA sheet with anti-rust treatment.2.Finished with epoxy powder coating of approved colour and shade.3.Approximate size: 900 mm W × 450 mm D × 1800 mm H, or nearest approved standard size.4.Cabinet shall have lockable shutters with internal shelves.5.Shelves shall be adjustable / fixed as per approved model.6.Suitable for storage of medicines, files, patient records and nursing consumables.7.Doors shall be provided with handles, lock and smooth hinges.8.Edges shall be smooth and safe for hospital use.9.Surface shall be easy to clean, corrosion-resistant and suitable for hospital environment.
116Doctor Consultation Table — Standard OPD+Duty Doctor Room:- Providing and supplying doctor consultation table, complete with the following specifications:1.Table suitable for OPD consultation room / duty doctor room.2.Size shall be approximately 1500 mm length × 750 mm depth × 750 mm height, or nearest approved standard size.3.Table shall be made of commercial plywood / MDF / pre-laminated board / engineered board of approved make.4.Top shall have laminate finish with proper edge banding.5.Table shall include drawers, shutter storage and/or pedestal unit as approved.6.Provision shall be made for writing, computer/laptop use and patient record handling.7.Hardware shall include good quality drawer channels, handles, locks and hinges.8.Exposed edges shall be finished with PVC edge banding / laminate edge finish.9.Surface shall be durable, easy to clean and suitable for hospital/office use.Approved make :- Godrej interio
117Doctor Chair — Standard Consultation / Duty Doctor Room:- Providing and supplying doctor chair / revolving chair, complete with the following specifications:1.High-back revolving chair suitable for OPD consultation room and duty doctor room.2.Seat and back shall be Leatherette upholstered as approved.3.Chair shall have hydraulic height adjustment with smooth revolving mechanism.4.Chair shall have stable five-star base with smooth-moving castors.5.Armrests shall be provided.6.Seat and back shall be ergonomically shaped for doctor/office use.7.Upholstery shall be easy to clean and suitable for hospital environment.8.Finish, colour and model shall be as approved by Engineer-in-Charge.
118Patient / Visitor Chair for Consultation Rooms:- Providing and supplying patient / visitor chair for OPD consultation rooms, duty doctor rooms and SMO consultation room, complete with the following specifications:1.Chair suitable for patient / visitor seating in consultation and doctor rooms.2.Frame made of CRCA steel with anti-rust treatment.3.Finished with epoxy powder coating finish of approved shade.4.Seat and back shall be cushioned as approved.5.Seat and back shall be ergonomically shaped with smooth rounded edges.6.Stable four-leg base with rubber shoes.7.Surface shall be durable, easy to clean and suitable for hospital use.8. Colour and finish shall be as approved by Engineer-in-Charge.
119EXAMINATION COUCH:- Providing and supplying examination couch suitable for OPD consultation rooms, duty doctor rooms and SMO consultation room, complete with the following specifications:1.Examination couch suitable for patient examination in OPD / doctor room.2.Frame made of MS tubular section with anti-rust treatment and epoxy powder-coated finish.3.Couch top shall be cushioned with high-density foam and covered with PU-coated leatherette.4.Approximate size: 1800–1900 mm length × 600 mm width × 750 mm height, or nearest approved standard size.5.Headrest/backrest shall be fixed or adjustable as per approved model.6.Provided with paper roll holder / storage shelf where available in approved model.7.Legs shall be provided with rubber shoes for stability.8.Upholstery shall be easy to clean, water-resistant and suitable for hospital use.9.Colour and finish shall be as approved by Engineer-in-Charge.
120Revolving Stool for Examination / OPD / Procedure Use:- Providing and supplying revolving stool suitable for OPD consultation rooms, examination areas, duty doctor rooms and procedure/OT support areas, complete with the following specifications:1.Revolving stool suitable for doctor/ examination/ procedure use.2.Frame/base made stainless steel as approved.3.Seat shall be cushioned and covered with PU-coated leatherette.4.Seat height shall be adjustable with screw-type or hydraulic mechanism.5.Base shall be stable with four-leg / five-leg arrangement.6.Provided with rubber shoes / castors as approved.7.Smooth, rounded and easy-clean finish suitable for hospital use.8.Colour and finish shall be as approved by Engineer-in-Charge.
121Side Credenza / Storage Unit for SMO Room:- Providing and supplying side credenza / storage unit for Senior Medical Officer room, complete with the following specifications:-Approximate size: 1200 mm length × 450 mm depth × 650–750 mm height, or nearest approved standard size.-Made of engineered wood / commercial board / pre-laminated board of approved make.-Top, sides, shutters and fascia shall be finished with approved laminate / pre-laminated finish.-Unit shall include combination of drawers, shutters and open/closed storage as approved.-Hardware shall include good quality drawer channels, hinges, handles, locks and magnetic catchers wherever required.-All exposed edges shall be finished with PVC edge banding / laminate edge finish.-Surface shall be durable, easy to clean and suitable for hospital office use.-Colour, shade and finish shall match / complement the SMO desk.
122Steel Almirah / General Storage Cabinet:- Providing and supplying steel almirah / general storage cabinet, complete with the following specifications:Cabinet shall be made of CRCA with anti-rust treatment.SIZE 900 mm W × 450 mm D × 1800–1950 mm H, or nearest approved standard size.Cabinet shall be finished with epoxy powder coating of approved colour and shade.Cabinet shall have double shutter doors with locking arrangement.Cabinet shall have minimum 4 internal shelves / 5 compartments.Doors shall be provided with handles, hinges and lock.Cabinet shall be suitable for storage of files, linen, medicines, consumables and hospital records.Surface shall be easy to clean, durable and suitable for hospital use.
123Stainless Steel Instrument Trolley- Providing and supplying stainless steel instrument trolley, complete with the following specifications:Trolley shall be made of stainless steel, preferably SS 304 grade.Size shall be 700 mm L × 500 mm W × 760–850 mm H, or nearest approved standard size.Trolley shall have two stainless steel shelves/trays.Shelves shall have raised edges / three-side railing to prevent instruments from falling.Frame shall be made of stainless steel tubular sections.Trolley shall be mounted on four smooth-moving castors.Castors shall be non-marking and suitable for hospital flooring.Finish shall be smooth, corrosion-resistant and easy to clean.Trolley shall be suitable for OT, procedure room, dressing room and clinical support use.
124Mayo Trolley:- Providing and supplying stainless steel Mayo trolley, complete with the following specifications:Trolley shall be made of stainless steel, preferably SS 304 grade.Trolley shall be height adjustable and suitable for OT / procedure room use.Top tray shall be stainless steel, removable type where available in approved model.Approximate tray size shall be 450 mm × 330 mm or nearest approved standard size.Frame shall be made of stainless steel tubular sections.Trolley shall be mounted on smooth-moving castors.Castors shall be non-marking and suitable for hospital flooring.Height adjustment shall be smooth and lockable at required position.Finish shall be smooth, corrosion-resistant and easy to clean.
125KICK BUCKET:- Providing and supplying stainless steel kick bucket / bowl stand, complete with the following specifications:Bucket / bowl stand shall be made of stainless steel, preferably SS 304 grade.Bucket / bowl capacity shall be suitable for OT / procedure / dressing room use.Frame shall be made of stainless steel tubular sections.Approximate height shall be 300–450 mm or nearest approved standard size.Unit shall be mounted on smooth-moving non-marking castors.Finish shall be smooth, polished, corrosion-resistant and easy to clean.Bucket / bowl shall be removable for cleaning and sterilization.Edges shall be smooth and safe for hospital use.Item shall be suitable for OT, procedure room, dressing room and clinical support areas.
126Manual Hydraulic OT Table:- Providing and supplying manual hydraulic operation theatre table, complete with the following specifications:Table shall be suitable for general surgery / minor OT use in hospital.Table shall be manual hydraulic type with height adjustment.Frame and base shall be made of stainless steel / powder-coated steel of approved make.Table top shall be sectional type with adjustable head, back and leg sections.Size shall be 1800–2000 mm length × 500–550 mm width.Height adjustment range shall be suitable for operation theatre use.Table shall have Trendelenburg / reverse Trendelenburg and backrest adjustment as per approved model.Mattress / cushion top shall be washable, water-resistant and suitable for OT use.Side rails shall be provided for fixing accessories.Accessories such as anaesthetic screen frame, arm board and leg supports shall be included as per approved model.Finish shall be corrosion-resistant, smooth and easy to clean.
127Patient Stretcher Trolley: - Providing and supplying patient stretcher trolley, complete with the following specifications:Trolley shall be suitable for patient transfer within hospital / emergency / ward / OT area.Frame shall be made of stainless steel / powder-coated MS tubular sections of approved make.Size shall be 1950–2100 mm L × 560–650 mm W × 750–850 mm H, or nearest approved standard size.Stretcher top shall be fixed / removable type as per approved model.Trolley shall be provided with washable mattress / stretcher pad.Trolley shall be mounted on four heavy-duty smooth-moving castors.At least two castors shall be provided with locking/brake arrangement.Side safety railings shall be provided where available in approved model.Provision for IV rod shall be provided.Finish shall be corrosion-resistant, smooth and easy to clean.
128Biomedical Waste Bin Set:- Providing and supplying biomedical waste segregation bin set, complete with the following specifications:Bin set shall be suitable for biomedical waste segregation in hospital areas.Set shall consist of colour-coded bins as per biomedical waste segregation requirement.Bins shall be made of HDPE / plastic / approved non-corrosive material.Each bin shall be foot-operated / pedal-operated type with lid.Capacity of each bin shall be approximately 30 litres, or as approved.Colour coding shall generally include Yellow, Red, Blue and White/Black/Green as per approved biomedical waste management plan.Bins shall be washable, durable, non-corrosive and easy to clean.Each bin shall have clear biomedical waste category label / sticker.Bins shall be stable and suitable for hospital ward, OPD, OT and clinical use.
129SS Medicine / Instrument Cabinet for OT:- Providing and supplying stainless steel medicine / instrument cabinet for OT, complete with the following specifications:Cabinet shall be suitable for storage of sterile instruments, medicines, dressings and OT consumables.Cabinet shall be made of stainless steel, preferably SS 304 grade.Approximate size shall be 900 mm W × 450 mm D × 1800 mm H, or nearest approved standard size.Cabinet shall have glass / acrylic vision panel shutters for visibility of stored items.Doors shall be lockable and provided with stainless steel handles and hinges.Cabinet shall have minimum 4 internal shelves, adjustable or fixed as per approved model.Shelves shall be strong enough for storing instruments and medicine packs.Finish shall be matt / brushed stainless steel finish, smooth, corrosion-resistant and easy to clean.Edges shall be smooth and safe for hospital / OT use.Cabinet shall be stable and suitable for OT / sterile storage environment.
130External Interlocking Paver Pathway (2.0 m wide)Providing and laying paver block pathway for pedestrian/wheelchair use, complete in all respects.Earthwork & Subgrade:Excavation to ~200–250 mm depth, dressing and compaction to 95% Proctor density.Sub-Base (PCC):Providing 100 mm thick PCC (1:4:8) rigid base.Bedding Layer:Providing 50 mm thick compacted sand layer.Surface Course (Pavers):Laying 60 mm thick CC interlocking paver blocks (M-30) with anti-skid finish.Edge Restraints & Drainage:Providing precast RCC kerb stones (M-25) on both sides; grass-side kerb with weep holes/perforations;providing 150 mm wide graded gravel strip along grass edge.Finishing & Slopes:Filling joints with fine sand and compacting with plate compactor; maintaining 2–2.5% cross fall towards grass side and minimum longitudinal slope; finished level ~50 mm above adjoining road.Rate includes: All labour, materials, machinery, leads and lifts, complete as per drawings and directions of Engineer-in-Charge.
131Earthwork: Box Cutting :- Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
132Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
133Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
134Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
135Parking Surface: 80mm Heavy-Duty Interlocking Pavers :- Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
136Parking Bay Demarcation: Thermoplastic Paint :- Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
137Earthwork: Box Cutting :- Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
138Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
139Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
140Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
141Providing and applying prime coat with cationic bitumen emulsion SS-1 grade conforming to IS: 8887 over prepared porous granular surface / WMM surface, including cleaning the road surface of dust, dirt, loose particles, mud, grease and foreign matter by mechanical broom / air compressor, light sprinkling of water where required, and spraying primer uniformly by mechanical pressure distributor / calibrated sprayer at the specified rate, complete as per MoRTH Clause 502 and directions of Engineer-in-Charge.
142TACK COAT : Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom With rapid setting bitumen emulsion On W.B.M / W.M.M. @ 0.4kg/sqm
143(DBM)Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and Directions of Engineer-in-Charge. 75 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
144BITUMINOUS CONCRETE:- Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
145SEAL COAT:- Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete
146Soil Preparation & Manuring:- Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
147General Grass Zone:- Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth,if needed (the grass and good earth shall be paid for separately). In rows 5 cm apart in both directionsThe contractor must grade the earth to a 1% to 2% slope before the horticulture to prevent grass zones from turning into mosquito breeding ground due to accumulation of rainwater. (Applies for all green zones)
148Providing and planting ornamental and foliage shrubs/hedges (such as Ficus panda, Bougainvillea, or Duranta repens) in the 2-meter wide perimeter belt. Plants shall be healthy, well-rooted, and supplied in minimum 8-inch to 10-inch polybags. The rate includes digging holes (45x45x45cm), applying root-growth hormones, planting, backfilling with the prepared soil-manure mix, and initial pruning to shape the hedge.Plants must be laid in a continuous trench (600mm x 450mm) rather than individual pits to ensure uniform root expansion and moisture distribution.Planting must be in a staggered \\"Z\\" or \\"W\\" pattern to ensure maximum visual density from the date of completion.
149Providing and laying ready-made premium carpet grass (Zoysia Matrella or Mexican Grass) for the IPD therapeutic garden. The grass shall be supplied in healthy, thick sods/mats with a minimum soil base of 25mm, completely free from weeds. The mats shall be laid tightly edge-to-edge over the prepared, perfectly leveled soil bed, and beaten down gently with a wooden mallet to ensure root-to-soil contact. The rate includes heavy watering, rolling with a light lawn roller, and one cycle of mowing after 15 days.
150Patient Benches: Cast Iron + WPC:- Providing and fixing premium heavy-duty outdoor garden benches (Length: 1.5m to 1.8m, seating 3 persons). The side frames, legs, and armrests shall be manufactured from heavy ornamental Cast Iron or powder-coated cast aluminum. The seating and backrest shall consist of minimum 25mm thick solid WPC (Wood Plastic Composite) planks with a natural wood-grain finish. The planks shall be bolted to the metal frame using stainless steel (SS 304) carriage bolts. The rate includes mechanical anchoring of the bench legs to the concrete/paver base using heavy-duty galvanized anchor fasteners to prevent tipping or theft.Nilkamal, Supreme, Sintex, or equivalent specialized street furniture.
151Concealed AC Pipe Chase / Sleeve Arrangement:- Providing and making concealed route arrangement for AC refrigerant piping, drain pipe and electrical/control cable from indoor AC unit location to vertical duct/shaft/terrace route, including wall chasing/recess cutting, core cutting/wall hole, PVC/GI sleeves, making good with cement mortar/plaster after pipe installation, finishing flush with wall surface, debris removal, labour, tools and tackles, complete as per approved AC layout and direction of Engineer-in-Charge.Design intent:To conceal AC refrigerant pipes, drain pipe and control wiring within wall/recess/sleeve so that the finished internal and external wall surfaces remain clean, plain and free from visible AC piping.-Route shall be finalized before plastering/painting/HPL/façade finishing work.-Cutting/chasing shall be done only along approved route and shall not damage structural RCC members, beams, columns or reinforcement.-Core holes through RCC/masonry shall be made with proper cutter/core machine; random hammer breaking shall be avoided.-PVC/GI sleeve shall be provided at wall penetrations for AC copper pipes, drain pipe and cable passage.-Sleeve shall be slightly sloped outward wherever condensate/drainage or external wall penetration is involved.-Adequate space shall be kept for insulated copper pipes; pipes shall not be tightly embedded without insulation.-Drain pipe route shall maintain proper slope and shall not create reverse gradient or concealed water trap.-Chases shall be refilled only after AC piping pressure testing / leak testing is completed.-Recess shall be made good with cement mortar/plaster and finished flush with wall surface.-Pipe installation, copper piping, insulation, drain pipe, electrical cable and AC units shall be measured separately under HVAC/electrical items unless specifically included.-Any RCC cutting/core cutting shall be done only with approval of Engineer-in-Charge/structural consultant.
152Extra Copper Refrigerant Pipe with Insulation:- Providing and fixing extra copper refrigerant piping for split AC units beyond standard company-supplied length, including required size copper suction and liquid line pair suitable for AC capacity, nitrile rubber insulation, wrapping tape, clamps, bends, brazing/flaring, leak testing, pressure testing, nitrogen purging wherever required, routing from indoor unit to outdoor unit on terrace, labour, tools and tackles, complete as per manufacturer’s specification and direction of Engineer-in-Charge.-Final pipe length must be checked against each AC manufacturer’s allowable maximum pipe length and vertical lift.-Copper pipe size must match AC capacity: 1 TR, 1.5 TR, 2 TR etc.-Copper pipes should be insulated throughout; never embed bare copper directly in wall.-Avoid joints inside concealed wall chase as far as possible.-Terrace penetration must be properly sleeved and waterproofed.-Drain pipe must have continuous slope; no reverse slope or concealed water trap.-Pressure/leak test should be done before closing the wall chase.-Outdoor units should be grouped neatly on terrace with service clearance.
153Condensate Drain Pipe for AC:- Providing and fixing 25/32 mm dia uPVC/CPVC condensate drain pipe from indoor AC unit to nearest drain/shaft/terrace drain point, including fittings, bends, supports, proper slope, testing, making good and all incidental works complete.-Final pipe length must be checked against each AC manufacturer’s allowable maximum pipe length and vertical lift.-Copper pipe size must match AC capacity: 1 TR, 1.5 TR, 2 TR etc.-Copper pipes should be insulated throughout; never embed bare copper directly in wall.-Avoid joints inside concealed wall chase as far as possible.-Terrace penetration must be properly sleeved and waterproofed.-Drain pipe must have continuous slope; no reverse slope or concealed water trap.-Pressure/leak test should be done before closing the wall chase.-Outdoor units should be grouped neatly on terrace with service clearance.
154High-Side HVAC Equipment- Providing, installing, testing, and commissioning Turnkey High-Side HVAC equipment, placed as per drawing, comprising:*1 No. 8 HP VRF/VRV Inverter Outdoor Unit with anti-corrosive fins.*1 No. 1,500 CFM Dedicated Double-Skin AHU. Inner skin min. 0.8mm SS-304, outer pre-coated GI, thermal break. Includes high-static blower, 6-row DX cooling coil, SS drain pan, 10-micron pre-filters, and 5-micron fine filters.*Factory-fitted electrical strip heaters (6kW–9kW) inside AHU for humidity control (reheat).*AHU-VRF integration kit (EXV & communication box) and microprocessor digital OT control panel.Machine Alignment: The AHU must be perfectly leveled on the RCC pedestal using vibration isolator pads to prevent humming noise in the OT.Reheat Interlock: The electrical strip heaters must be electronically interlocked with the AHU blower; the heaters should automatically cut off if the blower stops to prevent a fire hazard.UV Protection: The VRF integration kit and all outdoor electrical connections must be housed in a weatherproof (IP65) enclosure.Filter Access: A minimum of 1 meter clear space on the \\"service side\\" of the AHU for easy removal and cleaning of pre-filters and fine filters.
155Air Distribution & Weatherproofing:-Providing, fabricating, and erecting the complete air distribution network routed as per drawing, comprising:*Factory-fabricated GSS ducting (min. 24 SWG, IS:655) with aluminum Volume Control Dampers (VCDs) for supply, return, fresh air, and exhaust.*External thermal insulation using min. 19mm Class-O Nitrile Rubber with aluminum foil.*Mechanical weatherproofing for outdoor roof ducts using 24 SWG Aluminum cladding and PU sealant at slab penetrations.*Fresh air intake louvers (with washable filters) and 1 No. inline exhaust fan (~250 CFM) for gas dilution and pressure management.Leakage Testing: All duct joints must be sealed with antibacterial silicone sealant and pressure-tested before the thermal insulation is applied.External Cladding: Outdoor aluminum cladding must be installed with a \\"downward lap\\" (like roof shingles) to ensure rainwater flows off the duct and not into the joints.No Internal Insulation: There should be no acoustic or thermal insulation is placed inside the ducts, as it harbors bacteria. All insulation must be external.
156Cleanroom Terminals & Pressure Management:- Providing, installing, and commissioning cleanroom terminal components located as per drawing, comprising:*1 No. Custom Aluminum / SS-304 Laminar Air Flow (LAF) Plenum with CG screen diffuser and factory-sealed central pass-through collar for independent surgical light mounting.*H13/H14 terminal HEPA filters (99.97% @ 0.3 microns) fitted inside the LAF plenum.*4 Nos. flush-mounted SS-304 return air grilles with micro-mesh lint filters, fixed in low-level masonry corner ducts as per drawing.*SS-304 Gravity/Pressure Relief Dampers (PRD) flush-mounted in walls to maintain +2.5 to +5 Pascals positive pressure.Light-Plenum Gap: The independent MS light pipe must not touch the LAF plenum. The SS collar/escutcheon must be used to cover the gap while allowing the light to vibrate independently.PRD Calibration: Pressure Relief Damper calibration should be done only after the AHU is running at full load to ensure it maintains the +2.5 to +5 Pascal range.
157MEP Hook-ups & Structural Supports:- Providing and erecting MEP utilities and structural supports routed/located as per drawing*Hard-drawn copper refrigerant piping (with nitrile insulation) connecting ODU to AHU.*UPVC/CPVC insulated condensate drain piping with U-trap routed to the nearest drain.*Power and control cabling from OT electrical panel to AHU, ODU, and heaters.*Heavy-duty MS structural framing anchored to true RCC slab for independent suspension of the LAF plenum.Heavy-duty MS base plate (min. 10mm thick) and dropping MS pipe anchored to true RCC slab, passing entirely through the LAF plenum, for independent biomedical surgical light mounting.Structural Anchoring: Only heavy-duty Hilti-grade expansion fasteners for the RCC slab anchors should be used . Local handmade J-bolts. not allowed
158Cleanroom-Grade Calcium Silicate Dry Cladding:- Providing and erecting dry wall cladding for return-air corner pillars and walls as per drawing, comprising:Framework: Heavy-gauge (min. 0.8mm thick) 50mm GI U-tracks anchored to floor/ceiling and 50mm GI C-studs spaced at maximum 400mm center-to-center, with horizontal cross-bracing at every 1200mm height.Cladding Board: Minimum 12mm thick heavy-duty, moisture-resistant, and fire-retardant Calcium Silicate board.Fixing Hardware: Fastened using anti-corrosive, countersunk Stainless Steel (SS) self-drilling screws.Seamless Jointing: Joints treated with cleanroom-grade fiberglass mesh tape and two-part epoxy or specialized seamless jointing compound to achieve a perfectly flush, monolithic surface.OT Specific Integrations: Includes framing of precisely sized grille cutouts as per drawing, construction of an internal solid horizontal dummy base at 150mm above Final Floor Level (FFL), and 100% hermetic sealing of all duct-to-board interfaces using antibacterial RTV silicone.All complete as per the direction of the Engineer-in-Charge.Provide horizontal GI cross-bracing at the 2.4-meter mark and every 1.2 meters to support vertical board joints. No horizontal joint shall be left unsupported.
159Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
160Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
161Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
162Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.:-2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1632 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1642 X 4 sq. mm + 1 X 4 sq. mm earth wire
1652 X 6 sq. mm + 1 X 6 sq. mm earth wire
1664 X 6 sq. mm + 2 X 6 sq. mm earth wire
1674 X 10 sq. mm + 2 X 6 sq. mm earth wire
1684 X 16 sq. mm + 2 X 6 sq. mm earth wire
169Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. : - 50 sqmm 3.5 core
17070 sqmm 3.5 core
1713.5 X 50 sqmm. (35mm)
1723.5 X 70 sqmm. (45mm)
173Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
174Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 5/6 amps switch
175Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 3 pin 5/6 amp socket outlet
176Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 6 pin 15/16 amp socket outlet
177Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet
178Telephone socket outlet
179Data socket outlet
180Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C. Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg 1 Run of cable
181Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
182Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
183Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.:- 20 mm Dia
18425 mm Dia
18532 mm Dia
18640 mm Dia
187Brush Less DIrect Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
188Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
189Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
190LED Down lighter (COB Type) (System lumen efficacy ≥ 105 < 120lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector. 12 - 15 watt
191LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)18- 22 Watt
192Supply & fixing of water tight oblong \\"10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK 08. High purity transmisivity UV Stabilized Non yellowish diffuser/ for uniform light distribuljon, delachable driver set, open, and short circuit protection, suitable for 24 1tr Continuous Operation, Complete in All respect. compelete in all respect 1200 System lumens, >120 Lm/W, PF>0.95, CRI >70, 309V over voltage protection, 4 KV internal Surge Protection, metal housing with 5 years warrantee
193LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)36 watt
194Supply of Mirror Light 10 Watt LED . complete in all respect (only for estimation)
195Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
196Supply of exhaust fan 250mm (only for estimation)
197Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
198Supply of Wall Fan AC 230/250 Volts, 50 Hz 50w 1350 rpm including nuts, bolts, mounting frame and other accessorieswith connections etc. complete as required.-Make: Havells, Usha, Bajaj300 mm sweep.
199LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).100 watt
200Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
201Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
202Providing & fixing 6 SWG dia G.I. on surface or in recess for loop earthing as required.
203Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/lighting DBs for automatic switching On & Off of street lights at sunset & sun risr or twillight(Auto On, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c progamming at site complete required.2 output per phase and suitable for single phase supply
204Supply , Installation, Testing and Comissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper powercable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type cooling only:- 1.0 TR with 5 Star BEE Rating
2051.5 TR with 5 Star BEE Rating
2062.0 TR with 5 Star BEE Rating
207Supply, Installation, Testing and Commissioning of LED RGB/RGBWW/RG BNW/ RGBA/ RGBW (as per site requirement) Linear Profile / Wall Washer luminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of following wattage as given below.The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, having the rotation degrees scale shall be provided. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage , over volatge protection, driver inbuilt surge protection of 4KV and external surge prootection (SPD) of 10 KV common mode/differential mode , Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 10/20/30/40/60, asymmetric degree.Luminaire should have efficacy of minimum 40 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 24 V DC. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to +50°C and shall have impact resistance of IK 07. Lifetime of complete luminaire (LED ,Driver , Electrical & control circuitary) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accesories , Integral male/female water proof connectors of IP68 etc. as required.The successful bidder shall submit the following certifications/reports for approval beforesupplyof materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer,RoHS Compliance. Wattage per meter 30W
208Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
209Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)4 way (4 + 12), Double door
2106 way (4 + 18), Double door
211Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
212Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amp
213100 amp
214Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required40 amp
21563 amp
216Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
217Supply and fixing following rating double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
218Supply and fixing 20 amp, 240 volts, SPN industrial Type, socket outlet ,With 2 pole and earth ,metal enclosed plug top along with 20 amp. `C` series SPMCB , in sheet steel encosure, on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
219Supplying, installing, testing and commissiong of following capacity TPN tap off box made of 1.6 mm thick sheet steel enclosure duly painted with power coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earting etc. as required.200 A TPN
220Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.:- as follows :- 100 mm width X 50 mm depth X 1.6 mm thickness
221300 mm width X 62.5 mm depth X 2.0 mm thickness
222450 mm width X 62.5 mm depth X 2.0 mm thickness
223600 mm width X 62.5 mm depth X 2.0 mm thickness
224Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required.150 mm Dia
225250 mm Dia
226Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required.
227Earthing with Copper earth pipe, 600 mm X 600 mm X 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required.
228Supplying and Laying of 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
229Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
230Providing & fixing 25 mm x 5 mm. copper strip on surface or in recess for connection etc. as required.
231Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
232Providing & fixing 6 SWG dia G.I. on surface or in recess for loop earthing as required.
233SITC of safe Earthing Electrode T-39 Cu Copper Coated, Length 2000mm, outer pipe 76.3mm X 3.2 inner pipe 42.4mm X 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50kgs activated soil (BFC) capable of reucing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame withhinged cover & mansonry housing.(From electrode terminal to switch board, cost of 25x3 copper strip will be extra) As approved in U.P.P.W.D & C.P.R.I. all respects.
234Supply of single spike air terminals of 16/10 mm dia. & 2000 mm length as required and as per site conditions. The air terminal shall be manufactured with aluminium & shall be as per IEC 62561-2. The air terminal shall be fixed with base plate arrangement.
235Roof Conductor : Supply of 8 mm dia aluminum conductor for air termination network shall meet the requirement of IEC 62561-2.
236Supply of parapet Conductor holder for holding 8 mm dia. round conductor (for RCC parapet). The conductor holder should be installed at every 1 mtr. The conductor holder shall be made with clamp mounted on plastic base support & as per IEC 62561-4.
237Supply of Universal Connector for making straight, Tee & Cross joint of 8-10 mm Dia. Round Conductor to 8-10 mm Dia. Round Conductor on parapet wall, roof and vertical facade of masonery / glass / metallic work.
238Supply of Expansion piece made of Aluminium & as per IEC 62561-2 along with suitable connecting accessory. It shall be installed at every 20 mtr to maintain the flexibility to the conductor due to heat.
239Down Conductor : Supply of 8 mm dia aluminum conductor for Down Conductor network shall meet the requirement of IEC 62561-2.
240Supply of Wall Conductor holder for holding 8 mm dia. round conductor (for RCC wall). The conductor holder should be installed at every 1 mtr. The conductor holder shall be made with clamp mounted on plastic base support & as per IEC 62561-4.
241Supply of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value. (with enclosure). It shall meet the requirements of IEC 62561-2.
242Supply of Lightning Strike counter for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor. The Lightning Counter should be IP 68 rated enclosure suitable for external application.
243Supply of 10 mm Copper Bonded Steel Round Conductor (250 Microns Copper Coating) laid below the ground, as Required and as per specification and code of practice with Tee and Straight joint.
244Supply and fixing of M.V. Danger Notic Plate (only for estimation)
245Supply and fixing of H.T Danger Notic Plate (only for estimation)
246L.T. PANELIncoming :630 Amp. 4P MCCB - 1NoMetering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-200) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar :One (1) No.800A, TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.315 Amp. 4P MCCB- 3 No. 250 Amp. 4P MCCB- 5 No. 125 Amp. 4P MCCB- 4 No. 63 Amp. 4P MCB- 3 No. 63 Amp. 4P MCB- 1 No. -SpareOR outgoing as per site requirment(AS/SLD) OR outgoing as per site requirment(AS/SLD)
247U.P.S PANEL100 Amp. 4P MCCB - 1NoMetering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-100) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar :One (1) No.125 A, TPN aluminimum bus bar of suitable length.Outgoing :Phase indication lamps on each outgoing to be provided.63 Amp. 4P MCB- 1 No. 40 Amp. 4P MCB- 4 No. 63 Amp. 4P MCB- 1 No. -Spare40 Amp. 4P MCB- 1 No. -SpareOR outgoing as per site requirment(AS/SLD) OR outgoing as per site requirment(AS/SLD)
248Plumbing PanelThe minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmIncoming :1 x 80 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/f protection withTM based release.\\"1 x (Emergency Push buttons, auto/manual switch. as required)1 Nos. annunciation panel.\\"Metering :1 x ( 0-200A, 0-500V,multifunction meter with 3 x 200/5A, CL-1, 15VA, Ring type CTs)1 Nos. Set of Phase Indication Lamp.1 Nos. of class-III Type SPDBus Bar :125 Amp.TPN aluminimum bus bar of suitable length.25KAOutgoing :Phase indication lamps on each outgoing to be provided.01 No. 63 Amp 3P MCCB. (25 KA)02 No. 40 Amp 3P MCCB. (25 KA)02 No. 25 Amp 3P MCCB. (25 KA) Panel described as above
249Supplying, laying, testing and commissioning of 3C x 300 sqmm A2XFY, 33KV/33KV (unearthed) grade, heavy duty XLPE insulated, FRLS type, armoured cables suitable for 33kV, 50Hz, AC system with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel flat armouring and with all components as mentioned in BOQ, specifications and schedule, complete as required. 70 sq. mm 3 Core
250Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3C x 70 sqmm A2XFY , 33KV/33KV (unearthed) grade, heavy duty XLPE insulated, FRLS type, armoured cable as required.
251Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3C x 70 sqmm A2XFY , 33KV/33KV (unearthed) grade, heavy duty XLPE insulated, FRLS type, armoured cable as required.
252Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid
253White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
254Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole Basin mixer
255Kitchen sink with drain board 510x1040 mm bowl depth 200 mm
256Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and One urinal basin with 5 litre white P.V.C. automatic flushing cistern
257Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia
258Providing and fixing CP Brass 32mm/40mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
259Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
260Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect.
261Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
262Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
263Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore
264Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
265Providing & fixing storage type electric Hot water Geyser 20 Litre made out of heavy gauge steel jacket finished with rust proof baked-on glossy white enamel paint, inside glass lined heavy gauge copper tank, 25 mm thick polyurethane foam insulation, thermostatically controlled immersion heater with pilot neon lamp, replaceable magnesium anode bar, suitable for 8.0 bar maximum working pressure, cold water inlet and hot water outlet pipe, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. (Horizontal/Vertical) (only for estimation)
266Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge.
267Providing and fixing toilet paper holder C.P. brass
268Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms.
269Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. (a) 15mm nominal bore
270Blue Star 200L Cooling Storage Water Cooler SDLX200400B. Brand Name : Blue StarRefrigerant : R-22Power Source : ElectricDimensions : 1120 x 750 x 1500 mmVoltage : 230 VType of Product : Water Cooler
271Providing and laying cement concrete 1:5:10 (1 cement : 5 coarsesand : 10 graded stone aggregate 40 mm nominal size) all-roundS.W. pipes including bed concrete as per standard design : 100 mm dia
272Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm dia
273Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Coupler 110 mm
274Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee with door 110x110x110 mm
275Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Single tee without door 110x110x110 mm
276Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110mm bend
277Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110mm shoe
278Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
279Making khurras 60x60 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
280Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring leaving 10 mm gap for thermal expansion: 110 mm diameter.
281Providing and fixing 110 mm diameter UPVC pipe (Type A) as overflow scupper / rain water spout in parapet walls, cut to required length (typically 450mm to 600mm) and projecting a minimum of 150 mm beyond the exterior wall face. Includes making the hole in the brickwork and grouting it leak-proof with cement mortar 1:3 mixed with waterproofing compound.
282Providing and fixing factory-molded UPVC L-shaped corner roof drain / parapet scupper (110 mm diameter outlet) with a built-in ribbed flange for membrane bonding. Includes setting the drain flush into the concrete base/khurra, grouting with polymer-modified cement mortar, and connecting the outlet to the exterior downpipe or projecting it as a free-fall spout.
283Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof
284Providing, fixing, jointing and testing, uPVC SWR pipes, - type B conforming to IS : 13592 to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 110 mm dia. (only for estimation)
285Providing and fixing SWR PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 110mm x 110mmX110mm (only for estimation)
286Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (45°) 110mm (only for estimation)
287Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Y' Fitting without door 110mm (only for estimation)
288Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Single Tee without door 110mm (only for estimation)
289Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Coupler 110mm (only for estimation)
290Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Clean Out Plug 110mm (only for estimation)
291Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Vent Cowl 110mm (only for estimation)
292Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal 40mm dia. Pipe (only for estimation)
293Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (90°) 40mm (only for estimation)
294Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . Elbow (45°) 40mm (only for estimation)
295Providing, fixing, jointing and testing, unplasticized PVC pipes -10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete,for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc . T fitting 40mm (only for estimation)
296Supply and fixing of UPVC S.W.R. pipe Nahni Trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.
297Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P typeWith Sewer bricks conforming to IS : 4885
298Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
299Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia nominal bore
300Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 20 mm dia nominal bore
301Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 25 mm dia nominal bore
302Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 32 mm dia nominal bore
303Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 40 mm dia nominal bore
304Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace 50 mm dia nominal bore
305Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & Brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 65 mm nominal dia Pipes
306Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20mm dia nominal bore
307Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25mm dia nominal bore
308Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore
309Providing and fixing gun metal gate valve with wheel of approved quality. 40mm dia nominal bore
310Providing and fixing gun metal gate valve with wheel of approved quality. 50mm dia nominal bore
311Providing and fixing gun metal gate valve with wheel of approved quality. 65mm dia nominal bore
312Providing and Placing on Terrace (at all floor levels) Polyethylene Water Storage Tank (1500 ltr) of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Installed capacity to be 15000 litre
313Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer - in-charge, upto 90 metre depth below ground level. all types of soil 300 mm dia
314Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia
315Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
316Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge
317Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia
318Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete : 0 mm clamp
319Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 100 mm dia
320Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 4Cx 10 sq. mm
321Supply of Submersibule pump with control panel, support wireetc. complete 5.0 H.P. (KSB / EQ.)
32240 Amp, 25kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 1 Set
323Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected withthe earth conductor by clamps etc. 25 sq. mm 3-1/2 core
324Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
325Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Gun Metal
326Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: required : Gun metal
327Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 (b) 20 mm nominal internal dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipmets on wall. (d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40M
328Supplying, installation, testing and commissioning of weather proof M.S door and glass fire door size 2100 mm x 900mm fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - (only for estimation)
329Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: : 2 way-100 mm dia M.S. Pipe
330SLTC of M.S. pipe on surface :- Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.150 mm. Dia
331100 mm Dia
332Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 100 mm dia
333Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100 mm dia
334Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 100 mm dia
335Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
336Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100mm dia
337Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required.
338Providing & fixing Providing & Fixing of Double Flanged Metallic Expansion Joint (M.S. Fixed Flanges, PN-1.6, Complete in All Respects) for Flexible Connection at pump inlet and outlet etc. as required. 100 mm dia.
339(a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018. (d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head
340CONTROL PANELS :Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 125A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Terrace Fire Pump 80 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
341Providing and Placing on Terrace (at all floor levels) Polyethylene Water Storage Tank (500) of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Capacity 5000 litre
342Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completionof work
343Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along withsupply of all materials and labour for proper completionof work.
344Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed maintenance free batteries -1 set.
345Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required
346Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
347Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
348Supplying, installation, testing & commissioning of addressable fire control module complete as required.
349Supplying, installation, testing & commissioning of addressable manual call point complete as required.
350Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
351Supplying, installation, testing & commissioning of fault isolator complete with base as required.
352Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required.
353Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable Ethylene Propylene Runner (EPR) inshulation and LSZH inner bedding, steel wire armouring & FRLS outer sheath complete as required.
354Supply, installation, testing and commissioning of complete on-grid Solar PV Power Plant**, conforming to applicable BIS/IEC standards, MNRE guidelines, CEA Regulations and CPWD Specifications, including net metering, grid interconnection, protections, earthing, cabling, mounting structure, junction boxes, PCU/inverter, web-based monitoring, DCDB/ACDB, conduits, GI cable trays and all accessories, complete.PV Modules: Made-in-India mono/poly-crystalline modules, minimum 330 Wp, efficiency ≥23% at STC, conforming to IS 14286/IEC 61215 and IS/IEC 61730 Parts 1 & 2; Pmax temperature coefficient better than –0.30%/°C; operating range –10°C to +85°C and up to 100% RH; output warranty ≥90% after 10 years and ≥80% after 25 years; RFID tag with manufacturer, manufacturing date, cell/module origin, I-V curve, serial/model number, wattage, Im, Vm, FF and test-lab details.PCU/Inverter:350–800 V DC input, 415 V AC, 3-phase, 4-wire, 50 Hz ±2.5 Hz, voltage variation ±10%, efficiency ≥97%, THD <3%, operating temperature 0–50°C, minimum IP65 outdoor/IP21 indoor; MPPT, IGBT/MOSFET, microprocessor/DSP, meter, data logger, RS-485/RS-232, automatic wake-up, synchronization and shutdown, unbalanced-load capability, anti-islanding and manual DC isolation. Protection against under/over voltage and frequency, overcurrent, over-temperature, surge, short circuit and lightning; LCD/LED display for DC/AC voltage-current, power and energy parameters.Mounting Structure: Aluminium/galvanized MS conforming to IS 4759, minimum 2.4 m clear headroom, designed for site wind and seismic loads, corrosion-resistant and complete with maintenance/cleaning access.Monitoring: Real-time web-based monitoring of irradiance, temperature, DC/AC voltage-current, power, power factor, operating status and energy generation.Junction Boxes/Protection: IP65 GRP/FRP/powder-coated or cast-aluminium AJB/MJB, dust-, water- and vermin-proof, with busbars, MOV/surge arrestors, reverse-blocking diodes, DC isolators, glands and lugs; complete lightning, surge, earthing and grid-islanding protection.**Cables/Panels:** Required-size IR/UV-resistant, 1.1 kV XLPE insulated copper armoured ISI-marked power/control cables with conduits, GI trays, supports, glands, lugs and thimbles; IP65 free-standing metal-clad DCDB and ACDB with copper busbars and all required control and protection devices.
355Supply, installation, testing and commissioning of 30 kVA online VFI UPS, 1-phase input/1-phase output, unity output power factor, with modular power units below 10 kVA each; IGBT-based PWM rectifier and inverter, microprocessor digital control, static and manual bypass, isolation transformer, rectifier, inverter and VRLA-SMF battery bank in ABS containers for 30-minute full-load backup, minimum battery capacity 1600 VAH per kVA per hour.UPS shall have input 160–270 V AC, 50 Hz; true sine-wave output 220/230/240 V AC, 50 Hz ±0.2 Hz; efficiency >95%, input PF 0.99, input THD/TDD <5%, and suitability for 0.7 lagging to 0.7 leading loads. Overload capacity: 120% for 10 minutes and 150% for 1 minute; operating temperature 0–40°C, RH 0–95% non-condensing and noise <60 dB at 1 m.Complete with LC filters, battery racks, DC breaker, copper interconnecting cables/connectors, RS232/RS485/SNMP open-protocol BMS interface, display of voltage, current, watt and VA, and protection against under/over-voltage, abnormal output, overcurrent, short circuit, battery overcharge/deep discharge and 10 kV surge. Conforming to IEC 62040 Parts 1, 2 & 3 and applicable EN/IEC/VDE EMC standards, with QR code containing drawings, test reports, OEM manual and manufacturing-location geotag, complete in all respects.
356Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. DSR-2.8.1
357Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
358Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
359Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.
360Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.
361Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
36212mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand)
363Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar
364Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter
365Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually.
366Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia
367Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
368Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
369Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
370Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
371Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. DSR-2.8.1
372Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand:4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
373Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
374Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.
375Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.
376Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
37712mm cement plaster on rough side of single or half brick wall mix 1:3 (1 cement : 3 Coarse sand)
378Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar
379Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter
380Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.
381Open timbering in trenches including strutting and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter
382Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. RCC Pipes
383Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 250 mm. dia. RCC Pipes
384Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes
385Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 7.5
386Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
387Supply, installation, testing and commissioning of 62.5 kVA silent-type DG set, prime-rated, conforming to CPCB IV+ or better and CPWD Specifications, 415 V, 3-phase, 50 Hz, 1500 RPM, 0.8 PF and 0.85 load factor, including factory/site testing with fuel and load, QR code containing drawings, test reports, OEM manual and manufacturing-location geotag, complete.DG set shall comprise a turbocharged, 4-stroke, water-cooled, multi-cylinder diesel engine with electronic governor conforming to ISO 8528, electric start, dry air filter, initial fuel, lubricating oil and coolant, suitable for 40°C, 50% RH and 1000 m MSL, and capable of 10% overload for one hour after 12 hours’ continuous operation. Engine-mounted digital panel shall indicate start/stop, water temperature, oil pressure/temperature, battery voltage/charging, RPM, overspeed, low-oil trip, running hours and fuel level.Alternator shall be brushless, self-excited, AVR-controlled, continuous-duty, SPDP IP23, Class-H insulated, dynamically balanced and suitable for 10% overload, conforming to IS 13364/IS 4722/BS 2613. Engine and alternator shall be mounted on reinforced MS base frame over RCC foundation with vibration isolators.Complete with suitable 3 mm MS daily-service fuel tank and Class-C fuel piping, hospital-type silencer with catalytic converter, 12/24 V starting system with required 180 Ah SMF batteries, and CPCB-compliant weatherproof acoustic enclosure with ventilation, cooling and IP65 cable/bus-trunking entries.Provide OEM-made, floor-mounted IP42 AMF panel with auto bypass, motorised 4-pole draw-out ACB/MCCB, electronic O/C and E/F protection, CTs, energy analyser, Auto/Manual/Test/Off control, battery charger, mains-failure and restoration timers, three-attempt auto start/stop, annunciation, protection against over/under voltage and frequency, phase reversal, reverse power, loss of sensing, overload, short circuit, restricted earth fault and load unbalance. Panel shall include PLC-based load management, breaker/bus-coupler interlocking, maintenance alerts, RS485/Ethernet/SNMP open-protocol BMS integration, software, control wiring and aluminium power/copper control cables up to 15 m between DG set, AMF and LT panels, complete in all respects.
388Supply, installation, testing and commissioning of 100 kVA, BEE 3-Star rated, 33/0.433 kV, 3-phase, 50 Hz, Dyn11, ONAN copper-wound distribution transformer, suitable for continuous duty, indoor/outdoor installation, conforming to IS 2026 Parts 1–5, IS 1180, latest BIS requirements and CPWD Specifications, complete in all respects.Transformer shall have 99.9% electrolytic copper windings, first-grade CRGO core of MOH grade or better, maximum flux density not exceeding 1.9 Tesla under combined +12.5% voltage/frequency variation, and HV-side OLTC with AVR and RTCC for automatic, remote and manual operation from +5% to –15% in 2.5% steps. Provide HV cable end box suitable for 3 × 400 sq mm, 33 kV XLPE cable, LV bus-trunking arrangement, copper multicore control cable up to HT breaker/panel for safety tripping, first filling of filtered dehydrated transformer oil, MS channel foundation and grouting.Suitable for 50°C ambient temperature, 90% RH, site altitude and seismic zone; permissible temperature rise shall not exceed 35°C for oil and 40°C for winding. Tank interior shall be oil-resistant painted and exterior finished with thermosetting powder coating or epoxy primer with two polyurethane coats as per IS 1180. Noise level shall comply with NEMA TR-1/IEC 551.Complete with stainless steel/anodized aluminium rating plate, QR code containing drawings, test reports, OEM manual and manufacturing-location geotag; earthing terminals, oil-level gauge, silica-gel breather, air-release device, drain-cum-sampling valve, thermometer pocket, oil filling arrangement, lifting lugs, rollers, conservator with level indicator and drain plug, lightning arrestors/arcing horns, bird guards, pressure-relief device, inspection cover, detachable radiators with shut-off valves, additional neutral bushing and all required valves, hardware, clamps, lugs, fittings, accessories and safety provisions. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56476741
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.14 Crore
LAST DATE 04-08-2026
Authority
Authority Name Indo Tibetan Border Police Force
Work Description Tender for Construction of 10 Bedded Hospital At 9Th Bn Itbp Lohitpur (Ar.P)
Basic Detail
Tender No ITBP/SHQDBRG/ENGG/9BN/HOSP/290
Bidding Type Tender
Location
City Lohit
State Arunachal Pradesh
Key Dates
Publish Date 15 Jul 2026
Submission Date 04 Aug 2026
Open Date 05 Aug 2026
Finance
Tender Value 9.14 Crore
Tender Fee Ref. Documents
EMD 18.28 Lakhs
Exemption Not Available
Document List
aa4d95cf-c98d-4cd8-9947-960b8f2f816b.html
BOQ_964134.xls
Drg_Hospital.pdf
Tendernotice_1.pdf
Tender_doc.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Aug 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

aa4d95cf-c98d-4cd8-9947-960b8f2f816b.html

xls

BOQ_964134.xls

pdf

Drg_Hospital.pdf

pdf

Tendernotice_1.pdf

pdf

Tender_doc.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders