Tender For Thalassery Municipality Project No: So 251/26-Installation Of Solar Panel At New Municipal Office
Tender Value
18.21 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
1 days left
EMD
50000
Bank guarantee accepted
Document Fee
4299
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Thalassery Municipality Project No: So 251/26-Installation Of Solar Panel At New Municipal Office
BOQ
| Sl. No. | Item Description |
| 1 | APP A: Installation of Solar Panel |
| 2 | OD56224/2026-2027Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of200-1000 V DC Input voltage range or nearest range and 400V AC, three phase, 4wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiencynot less than 97%, total harmonic distortion less than 3% and suitable for ambienttemperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequencylevel to suit the Grid Voltage Frequency and adustiable for connecting time to gridasper KSEB norms, including Data Monitoring System complete with accessorieswifi/LAN connecting and connected application software etc. fixing on wall usingwall brackets and giving all connection as required . |
| 3 | OD56235/2026-2027Supply and providing Solar Photovoltaic Module Mono Perc Half Cut / Bi facialMono Perc Half Cut of capacity 540 Wp or nearest size, manufactured in India,conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. SolarPhotovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak wattcapacity, which should not be less than 90% at the end of 10 years and 80% at the endof 25 years. fixing on existing steel frame work using nut bolts/screws etc in suitabledirection at site condition and giving connection and inter connection wire tied usingsuitable steel wire tie as per the system string design and direction of department staff |
| 4 | OD56225/2026-2027Supply and providing wall mounted AC DB for on grid solar system for connectingInverter AC side consists of a). Poly carbonate Enclosure IP65 protection withtransparent front cover with hinged door and termination arrangement, b). SPDUp1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection usingsuitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection andDB fixing on wall using suitable screws and plugs etc as required |
| 5 | OD56229/2026-2027Supply and providing wall mounted DC DB for on grid solar system for connecting 2 Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65 protection with transparent front cover with hinged/screws door and termination arrangement, b). 2set 20A DC Fuse and Holder for +ve and connector for -ve incomerside, c). 2set SPD 1000V DC Up1.9kV,Ucpv 585 VDC, In 15kA, Imax 40kA and giving internal connection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitable screws and plugs etc as required |
| 6 | OD56221/2026-2027Supplying and drawing 1 run x 4 sq. mm PVC insulated tinned copper conductor,single core Solar DC cable in the existing surface / recessed steel/ PVC conduit asrequired. |
| 7 | OD56238/2026-2027Supply and crimping the Male Female MC4 Solar Panel cable connector includingcrimping and connecting etc as required. |
| 8 | OD56232/2026-2027Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board andto fix KSEB meters, fuse units etc as required including fixing it on wall, makinggood the damages colour washing etc. as required. |
| 9 | OD56222/2026-2027Providing and fixing following capacity TP and N Isolator unit inside the existingpanel board with ISI marked HRC fuses including drilling holes in cubicle panel,making connections, etc. as required.63 Amp |
| 10 | 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 11 | OD56237/2026-2027Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C"curve, miniature circuit breaker suitable for inductive load of following poles in theexisting MCB DB complete with connections, testing and commissioning etc. asrequired.Triple pole |
| 12 | 2.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 13 | 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 40 amps |
| 14 | OD56236/2026-2027Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range,electronic type in the existing meter board complete with connections, testing andcommissioning etc. as required (including testing if required, test certificate forsubmitting KSEB) |
| 15 | OD56233/2026-2027Supply and wiring with PVC insulated stranded single core copper conductor cablesfor interconnecting the control devices/ equipment's including the wiring firmby suitable tie/ tie mounts/ PVC duct etc as required. 10 Sqmm single run |
| 16 | OD56223/2026-2027Supplying and fixing Three phase 4 wire KWh Net meter, 415V, 10 - 100 A ornearest range ,electronic type in the existing meter board complete with connections,testing and commissioning etc. as required for charging On grid plant afterdismantling the existing KWH meter (including testing if required, test certificate forsubmitting KSEB). |
| 17 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 18 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm |
| 19 | 90.9.2.1Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 onsurface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.100 x 50 mm CMS with base and lid |
| 20 | 90.9.2.8Supply and fixing 100 x 50 mm PVC Cable Management System with base and lidalong with the following accessories conforming to IEC 61084/ BS 476 & 4678 onsurface / recess including cutting the wall and making good the damages in case ofrecessed installation as required.End cap |
| 21 | 90.6.4.54Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single corecopper conductor cables conforming to IS 694 part I 1990 in the existing surface /recess conduit as required including giving necessary connections of the followingsizes.10.00 sq.mm 4 Run |
| 22 | 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 23 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 24 | 90.16.1.8Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required8.00 mm copper conductor (0 SWG) |
| 25 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired. |
| 26 | OD56230/2026-2027Supply and fixing 2 x 25mm X 3 mm copper strip test joint for the earthing system. |
| 27 | OD56231/2026-2027Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to theearth plate |
| 28 | OD56227/2026-2027Supply and providing 25x3mm brass bolt |
| 29 | OD56226/2026-2027Supply and providing 25 x 6mm brass bolt |
| 30 | OD56239/2026-2027Supply and providing 12x3 mm brass bolt |
| 31 | OD56228/2026-2027Supply and providing Copper Bounded lightning arrester single spike " Airtermination rod " are placed on top of the structure using suitable base plate andnut bolt and giving connection to existing lightning down conductor etc as required. |
| 32 | 90.16.3.9Supply and clamping the following size of strips on surface of wall/ parapet/ existingcable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy dutyGI spacer saddles spacing of clamps not exceeding 1 m, making good the damages,colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip |
| 33 | OD56234/2026-2027KSEB and Electrical inspectorate Charge for availing approval from electricalinspectorate if required and on grid solar system feasibility and charging charge(Actual amount will be reimbursed on production of receipts) |
| 34 | APP B: Truss Work for Fixing Solar Panels |
| 35 | 50.10.2Steel work for purlin/single section with G I pipes including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 36 | 10.25.2Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works |
| 37 | OD56220/2026-2027Fabrication supply conveyance and installation of Granite name board indicating thecost involved, commencement date, completion date and inaguration date etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender