Tender For Relocation Of 63Kva Transformer At Gass Sund Syed Basti Surfraw/Sumbal Under Ddc Grants .
Tender Value
3.04 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
5 days left
EMD
6100
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganderbal → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Relocation Of 63Kva Transformer At Gass Sund Syed Basti Surfraw/Sumbal Under Ddc Grants .
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 33] |
| 2 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 15] |
| 3 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and Laying of 0.05 ACSR Conductor |
| 4 | Supply,installation, testing and commissioning of Gapless Surge Arrestor, 9kV, 10KA LA with polymer housing, station type. |
| 5 | Supply,installation, testing and commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 6 | Supply,installation, testing and commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole,200 Amp, Vertical Type |
| 7 | Providing & fixing of GI Channel cross-arm (100 x 50x6mm) / 75x40x40 x6mm including back clamps of 50X8 mm for fixing Cross arm and pole top bracket, Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing Cross arm and pole top bracket and Pole Butt. |
| 8 | Supply,installation, testing and commissioning of 11 KV Polymeric Composit pin with insulator insulator 12 KV, 5 KN,Light Impulse 75 KVPositive and 80 KV Negative ,Creepage distance 320 mm |
| 9 | Supply,installation, testing and commissioning of 11 KV Polymeric Composit disc insulator 12 KV,5KN, light impulse 75 KVPositive and 80 KV Negative ,Creepage distance 320 mm |
| 10 | Providing & Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) |
| 11 | Supply,installation, testing and commissioning of Galvanized Nuts and Bolts of sizes. |
| 12 | Providing & Laying of Cement bottoming 1:2:4 mix as per Standards 0.40 cum per pole for ( 8 Mtr) |
| 13 | Providing & Laying of Cement bottoming 1:2:4 mix as per Standards 0.45 cum per pole for ( 9 Mtr) |
| 14 | Providing & fixing of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm |
| 15 | Providing & Laying of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm No.minal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover |
| 16 | Supply,installation, testing and commissioning of GI wire |
| 17 | Supply,installation, testing and commissioning of LT Fuse Set |
| 18 | Supply,installation, testing and commissioning of 16 KN Polymer Shackle Insulators LT |
| 19 | Supply,installation, testing and commissioning of GI Mukey for Shackle Insulator with Bolt of (50x6)mm |
| 20 | Supply,installation, testing and commissioning of GI Barbed Wire for Anticlimbing Device |
| 21 | Supply,installation, testing and commissioning of Danger Plates with clamps with writing in English and Regional Language |
| 22 | Supply,installation, testing and commissioning of Anti Climbing Device with Clamps |
| 23 | Providing & fixing of Wedge Connectors/PG Clamps |
| 24 | Sundry Items like Aluminium Lugs, Jumpers, Binding Tape |
| 25 | Dismentalling and Reinstallation of 63 KVA Dt's |
| 26 | Providing of Stencil and Spray Painting (Black in Colour) on each Pole at an height of 4.5 feet above ground levelwith following specification:1.The Dimension of the Stensil should be not less than 21\\"x9\\" per pole.2.The following details are to be recorded on each pole with the Spray paint.a). Name of the Workb)Yearc). name of the Contractord). SR of the poleThe said Stensil should be approved by EDV Ganderbal |
| 27 | Pre and Post Geo tagged Photographic Evidence consisiting of 5x7 inch Photographs and Autocad Single Line Diagram Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender