Power Government Departments Closing in 1 days TDR #56475049

Tender For 33 Kv Isolator, 33 Kv Fuse Set, Control Cable, Relay And Earthing Etc. Work Of 33/11 Kv Power Substation Amheda In The Jurisdiction Of Subdivision-Iv Ganganagar, Meerut Of Electricity Distribution Division-I Meerut.

Issued by Government Departments · Meerut, Uttar Pradesh
Tender Value
8.40 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
1 days left
EMD
8400
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Meerut → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For 33 Kv Isolator, 33 Kv Fuse Set, Control Cable, Relay And Earthing Etc. Work Of 33/11 Kv Power Substation Amheda In The Jurisdiction Of Subdivision-Iv Ganganagar, Meerut Of Electricity Distribution Division-I Meerut.

BOQ

Name of Work:- fo|qr forj.k [k.M&izFke esjB ds mi[k.M&prqFkZ xaxkuxj] esjB ds dk;Z{ks= es 33@11 dsoh fo|qr midsUnz vEgSMk ds 33 dsoh vkblksysVj 33 dsoh ¶;wt lsV daVªksy dsfcy fjys ,oa vfFkZax bR;kfn dk;ZA
Sl. No. Item Description
1Supply of fixing of 33 KV ISOLATOR connectors for dog conductor.
2Repairing & Overhauling of 33KV Isolator of BSI & LSI various make by way of opening of jaw & blade, cleaning and rubbing of Flash spots, refitting of jaw and blade, checking and adjusting of alignment etc., oiling and greasing of movable parts with all associated work at fallowing sub station.
3Supply & fixing of 33 KV FUSE SET connectors for dog conductor.
4Control Cable Laying.Providing & Laying of different size of (2x2.5)mm2 control cables i.e.from Buchholz relay to Marshalling box Marshalling box to switch gear room, 33KV CT's to CT's Junction Box, CT 33KV, 33 KV P.T. V.C.B Control Panel Junction Box to 33 KV VCB control panel and control panel to 33KV VCB outdoor operating mechanism panel panel from T/F etc.in the cabel trench including makig proper connection at Buchholz Realy, Marshalling box as per required for installed equipment.
5Providing & Laying of different size of (4x2.5)mm2 control cables i.e.from Buchholz relay to Marshalling box Marshalling box to switch gear room, 33 KV CT's to CT's Junction Box CT 33KV, 33 KV P.T, V.C.B control panel junction Box to 33 KV VCB control panel and control panel to 33 KV VCB outdoor operating mechanism panel from T/F etc.in the cable trench including making proper connection at Buchholz Relay, Marshalling box as per required for installed equipment.
6Providing & Fixing of 33 KV CT junction box for connection and wiring of 33 KV CT as per PVVNL respo.
7Supply of 415 volt AC lighting DB with canopy for outdoor.
8(i) Current rating: 1A/5A Site selectable. (ii) Aux Supply: 180-240V AC+24V DC rated (As per IEC) with communicable Port.(iii) Draw Out with CT Shorting.(iv) Front LEDs Display for following:- L1, L2, L3, E, Trip for Faulty Phase/Earth, Low Set Trip, High Set Trip.(v) Relay Should have minimum 4 DI, 6 DO.(vi) The relay should have cold load pick ip, Harmonic Blocking and CBFP. It should have minimum 10 Fault records and 10 Events records.a Ip>5 to 400% in step of 1%.b Ip>5 to 3000% in step of 1%.c Ie>5 to 250% in step of 1%.d Ie>5 to 1500% in step of 1%.e Te>0.02 Sec to 20 sec in step of 0.01 Sec.f Ti>0.02 Sec to 20 sec in step of 0.01 Sec.Note:- Breaker Failure Detection.Communication Ports: RS485/RS232.Communication Protocols: MODBUS-RTU&IEC 60870-5-103.Programming through local keypad.Selectable definite Time or IDMT curves as per IEC standards.Rated input current selectable 1A or 5A.Password protection to guard against unauthorized access & editing of setting.Storage of latest 10 fault records with time stamping. Mounting/Case:- Draw-out/Non Draw-out.Trip Circuit Supervision through digital input.
9Supply & Erection of Water level earthing by Boring and lowering by providing of G.I. Pipe size 40mm dia, into the ground upto water level or minimum 20Mtr, which ever is more, with the lower end of solid copper cone approx 224mm long and 750gm in weight shall be provided and screwed in pipe as well as bringing out a continuous copper wire 6 SWG, from the cone upto the ground surface where it will be bolted to the G.I. Strip for Transformers neutral connection, the G.I. strip will be connected to star point through providing copper bond strip of size 35x6mm as per PVVNL guidline. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56475049
AUTHORITY Government Departments
TENDER VALUE 8.40 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Paschimanchal Vidyut Vitran Nigam Limited
Work Description Tender For 33 Kv Isolator, 33 Kv Fuse Set, Control Cable, Relay And Earthing Etc. Work Of 33/11 Kv Power Substation Amheda In The Jurisdiction Of Subdivision-Iv Ganganagar, Meerut Of Electricity Distribution Division-I Meerut.
Basic Detail
Tender No ETNo.24/EDC-1/MT/2025-26
Bidding Type Tender
Location
City Meerut
State Uttar Pradesh
Key Dates
Publish Date 14 Jul 2026
Submission Date 20 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 8.40 Lakhs
Tender Fee 1180
EMD 8400
Exemption Not Available
Document List
924c6413-e53d-4f97-9f88-9fd921447496.html
BOQ_2193645.xls
TENDERFORM24.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

924c6413-e53d-4f97-9f88-9fd921447496.html

xls

BOQ_2193645.xls

pdf

TENDERFORM24.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders