Power Government Departments Closing in 7 days TDR #56474941

Tender For Civil Rectification And Strengthening Work Of Control Room Building At 33/11 K.V. S/S Hiranpur,& Construction Of Boundarywall At 33/11 K.V. S/S Ardauna, Distt- Mau.

Issued by Government Departments · Mau, Uttar Pradesh
Tender Value
9.52 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
7 days left
EMD
19500
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mau → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Civil Rectification And Strengthening Work Of Control Room Building At 33/11 K.V. S/S Hiranpur,& Construction Of Boundarywall At 33/11 K.V. S/S Ardauna, Distt- Mau.

BOQ

Name of Work:- CIVIL RECTIFICATION AND STRENGTHENING WORK OF CONTROL ROOM BUILDING AT 33/11 K.V. S/S HIRANPUR,& CONSTRUCTION OF BOUNDARYWALL AT 33/11 K.V. S/S ARDAUNA, DISTT- MAU.
Sl. No. Item Description
1Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
2CEMENT PLASTER (IN COARSE SAND) 1:4 (1 cement: 4 coarse sand)
3CEMENT PLASTER (IN COARSE SAND) 1:6 (1 cement: 6 coarse sand)
4CEMENT PLASTER (IN COARSE SAND) 1:3 (1 cement: 3 coarse sand)
5Neat cement punning.
6Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. For the purpose of measurement the entire treated surface will be measured.
7Dismantling flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
8Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
9Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
10Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
11Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
12Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
13Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
14Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
15Of area 3 sq. metres and below -w
16Of area beyond 3 sq. metres-D
17Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
18Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm
19Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
20Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
21Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured)5.0 mm thick (weight not less than 12.50 kg per sqm) instead of 4 mm thick (weight not less than 10 kg per sqm).
22Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C
23S/F suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including connections,painting etc. as required (DSR M&M 2022 1.57)
24Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect
25Supply Installation, Testing and Commissioning of 1200mm sweep, BEE 5 Star rated, ceiling fan with Brush less Direct Current (BLDC) Motor, class of Insulation: B, 3 nos blades,30cm long down rod,2 nos canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CM/M/W) minimum 6.00 Air delivery minimum 210 Cum/min 350 RPM (tolerance as per IS:374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise-75 degree C (MAX.) INSULATION RESISTANCE MORE THAN 2 MEGA OHM. SUITABLE FOR 230v, 50Hz. Songle phase AC supply, earthing etc. complete as required (DSR E&M 2022 19.1)
26Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
27Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
28Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
29Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
30Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
31Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
32Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
33Providing and laying in 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
34Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level.
35Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
36Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
37Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
38Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete
39Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
40Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts
41Grouting of vertical or inclined post of pale/chain/security fencing in true level, alignment and in plumb or inclination as required, including cost of all labour, materials and T&P required for proper completion of work. ( Post and concrete for grouting shall be measured separately)
42Providing and laying in 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
43Construction of boundary wall with Precast Column and Pannel (with prestressed concrete , pannel size-2100x300x50mm and column size 150x150x2400mm ,1800 mm. above and 600mm. below ground level) including fixing of pannel & column in proper alignment including cost of all material labour and T&P etc. required for proper complection of work as per direction of engineer incharge . (C.C. for grouting, excavation of pit and P.C.C. shall be paid extra) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56474941
AUTHORITY Government Departments
TENDER VALUE 9.52 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Purvanchal Vidyut Vitaran Nigam Limited
Work Description Tender for Civil Rectification And Strengthening Work Of Control Room Building At 33/11 K.V. S/S Hiranpur,& Construction Of Boundarywall At 33/11 K.V. S/S Ardauna, Distt- Mau.
Basic Detail
Tender No 108/ECDD(V)/2026-27
Bidding Type Tender
Location
City Mau
State Uttar Pradesh
Key Dates
Publish Date 15 Jul 2026
Submission Date 05 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 9.52 Lakhs
Tender Fee 1180
EMD 19500
Exemption Not Available
Document List
6929b96b-01b1-4a56-a24d-c9dac996a222.html
BOQ_2194664.xls
SPECIFICATIO108.pdf
TENDERDOCUMENTSVARANASI.pdf
Tendernotice_1 (28).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

6929b96b-01b1-4a56-a24d-c9dac996a222.html

xls

BOQ_2194664.xls

pdf

SPECIFICATIO108.pdf

pdf

TENDERDOCUMENTSVARANASI.pdf

pdf

Tendernotice_1 (28).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders