Drinking Water Supply and Sanitation Government Departments Closing in 9 days TDR #56474924

Tender For E-Quotation For Seeking Firm Rates For Non-Schedule Items For Preparing Estimates.

Issued by Government Departments · Ranchi, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Jul 2026
9 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for E-Quotation For Seeking Firm Rates For Non-Schedule Items For Preparing Estimates. , Supplying , Installation, Testing And Commissioning Of Vertical Turbine Pump Set With Ss Impeller Capable To Discharge 126 M3/Hr.Against Total Head Of 50 M, (Make Kirloskar/Jyoti/Wilo-Mather&Platt/Wpil) Coupled With Suitable Capacity Vertical Hollow Shaft/Solid Shaft Squirrel Cage Induction Motor , Rating Of Motor 20% More Bhp Than That Of Pump (Make Kirloskar /Abb /Cgl/ Siemens) Operated On 415 +/- 10% Volt, 3 Phase , 50 C/S A.C Supply , Ie3 Type As Per Is:325 And Iec:63400-Ihaving Speed 1450 Rpm,With Heavy Duty M.S. Column Assembly With Ss Line Shaft And Each Coloumn Of 5 Feet Length Including Cost Of Supplying , Fitting And Fixing Of All Required Accessories Such As Cidf Sluice Valve-1 Set, Cidf Nr Valve-1 Set, Pressure Gauge-1 No, Strainer-1 No, M.S. Channel Base Plate Etc. All Complete Including Cost Of Taken Out Existing Old Pumpset. , Supplying And Installation Of Fasd Starter Suitable For Above Mentioned Vt Pumpset Make Lk/Bch/Schneider. , Supplying And Laying Of 25 Mm2 , 1.1 Kv, 3 Core Pvc Insulated Unarmoured Copper Cable Make Polycab/Kei/Gloster, From Starter To Motor. , Supplying, Installation Testing And Commissioning Of Horizontal Split Casing Centrifugal Pump Set With Bronze Impeller Having Discharge 126 M3/Hr. Against Total Head Of 35 M, (Make - Kirloskar/Jyoti/Wilo-Mather&Platt/Wpil), Coupled With Suitable Capacity Squirrel Cage Induction Motor, Rating Of Motor 20% More Bhp Than That Of Pump(Make Kirloskar /Abb /Cgl/ Siemens) ,Tefc, Ie3 Type As Per Is:325 And Iec:63400-Ihaving Speed 1450 Rpm,Operated On 415 +/- 10% Volt, 3 Phase , 50 C/S A.C Supply, Mounted On A Commonm.S. Base Plate Including Cost Of Supplying , Fitting And Fixing Of All Required Accessories Such As Cidf Sluice Valve-1 Set, Cidf Nr Valve-1 Set, Pressure Gauge-1 No, Foot Valve-1No, Etc. All Complete Including Cost Of Taken Out Existing Old Pumpset. , Supplying And Installation Of Fasd Starter Suitable For Above Mentioned C/F Pumpset Make Lk/Bch/Schneider. , Supplying And Laying Of 16 Mm2 , 1.1 Kv, 3 Core Pvc Insulated Unarmoured Copper Cable Make Polycab/Kei/Gloster, From Starter To Motor. , Wiring For Light Point / Fan Point/Exhaust Fan Point With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core In Surface Pvc Conduit, Piano Type Switch, Phenolic Laminated Sheet With Suitable Size Pvc/Ms Box Etc As Required At Pump House At Intake Well And Clear Water Pump House. 15 Point. , Cost Towards Complete Repairing Of Control Panel At Intake Well With Changing Of Damaged Parts Such As :- 1.150 annual periodical maintenance Tpn Mccb,50 Ka -1 No. As Incoming Feeder. 2. 75 annual periodical maintenance Tp Mccb, 50 Ka-2No As Outgoing Feeder. 3.Star Delta Timer-2Nos(One For Each Starter) 4. 32 annual periodical maintenance Switch Fuse Unit -01 No. For Internal And External Light Load. 5. (0-500 V) Volt Meter-01 No., Ampere Meter-01 No.,Three Phase Indicator Lamp,Powder Coating Paint,Push Button On/Off,On/Off/Trip Indicator Lamp,Wiring,Etc As Per Required And Testing On Full Load . , Cost Towards Providing All Labour, Tools And Technicians For Taken Out And Dismantling 40 Hp Vt P/Set With Bowl Assembly, 6 Dia. Coloumn Pipe And Line Shaft Etc All Complete. , Cost Towards Dismantling And Repairing Of Complete Bowl Assembly. , Cost Towards Making Supplying And Fitting S.S. Top Shaft As Per Size And Sample. , Cost Towards Making Supplying And Fitting Of C.I. Spider Bearing Having Od 6.5 With Rubber Bush As Per Size And Sample. , Cost Towards Lowering Of Vt P/Set. After Complete Repairing And Assembling Works. , Cost Towards Complete Repairing Of Control Panel At Clear Water Pump House With Changing Of Damaged Parts Such As :- 1.125 annual periodical maintenance Tpn Mccb,50 Ka -1 No. As Incoming Feeder. 2. 63 annual periodical maintenance Tp Mccb, 50 Ka-2No As Outgoing Feeder. 3.Star Delta Timer-2Nos(One For Each Starter) 4. 32 annual periodical maintenance Switch Fuse Unit -01 No. For Internal And External Light Load. 5. (0-500 V) Volt Meter-01 No., Ampere Meter-01 No.,Three Phase Indicator Lamp,Powder Coating Paint,Push Button On/Off,On/Off/Trip Indicator Lamp,Wiring,Etc As Per Required And Testing On Full Load .

BOQ

Name of Work:- E-quotation for seeking firm rates for non-schedule items for preparing estimates.
Sl. No. Item Description
1Supplying , Installation, Testing and commissioning of Vertical Turbine pump set with SS impeller capable to discharge 126 m3/hr.against total head of 50 m, (make Kirloskar/Jyoti/Wilo-Mather&Platt/WPIL) coupled with suitable capacity vertical hollow shaft/solid shaft Squirrel cage induction motor , rating of motor 20% more BHP than that of pump (make Kirloskar /ABB /CGL/ Siemens) operated on 415 +/- 10% volt, 3 phase , 50 C/S A.C supply , IE3 type as per IS:325 and IEC:63400-Ihaving speed 1450 rpm,with heavy duty M.S. column assembly with SS line shaft and each coloumn of 5 feet length including cost of supplying , fitting and fixing of all required accessories such as CIDF sluice valve-1 set, CIDF NR valve-1 set, pressure gauge-1 No, strainer-1 No, M.S. channel base plate etc. all complete including cost of taken out existing old pumpset.
2Supplying and Installation of FASD starter suitable for above mentioned VT pumpset make LK/BCH/Schneider.
3Supplying and Laying of 25 mm2 , 1.1 kv, 3 core PVC insulated unarmoured copper cable make Polycab/KEI/Gloster, from starter to motor.
4Supplying, Installation Testing and commissioning of Horizontal split casing centrifugal pump set with Bronze impeller having discharge 126 m3/hr. against total head of 35 m, (make - Kirloskar/Jyoti/Wilo-Mather&Platt/WPIL), coupled with suitable capacity squirrel cage induction motor, rating of motor 20% more BHP than that of pump(make Kirloskar /ABB /CGL/ Siemens) ,TEFC, IE3 type as per IS:325 and IEC:63400-Ihaving speed 1450 rpm,operated on 415 +/- 10% volt, 3 phase , 50 C/S A.C supply, mounted on a commonM.S. base plate including cost of supplying , fitting and fixing of all required accessories such as CIDF sluice valve-1 set, CIDF NR valve-1 set, pressure gauge-1 No, Foot valve-1No, etc. all complete including cost of taken out existing old pumpset.
5Supplying and Installation of FASD starter suitable for above mentioned C/F pumpset make LK/BCH/Schneider.
6Supplying and Laying of 16 mm2 , 1.1 kv, 3 core PVC insulated unarmoured copper cable make Polycab/KEI/Gloster, from starter to motor.
7Wiring for light point / fan point/exhaust fan point with 1.5 sq.mm FR PVC insulated copper conductor single core in surface PVC conduit, Piano type switch, phenolic laminated sheet with suitable size PVC/MS box etc as required at pump house at Intake well and clear water pump house. 15 Point.
8Cost towards complete repairing of control panel at Intake well with changing of damaged parts such as :-1.150 Amp TPN MCCB,50 KA -1 No. as incoming feeder.2. 75 Amp TP MCCB, 50 KA-2No as outgoing feeder.3.Star delta timer-2Nos(One for each starter) 4. 32 Amp switch fuse unit -01 No. for internal and external light load.5. (0-500 v) Volt meter-01 No., Ampere meter-01 No.,Three phase indicator lamp,Powder coating paint,Push Button ON/OFF,ON/OFF/TRIP Indicator lamp,Wiring,etc as per required and testing on full load .
9Cost towards providing all labour, tools and technicians for taken out and dismantling 40 HP VT P/Set with bowl assembly, 6\\" dia. coloumn pipe and line shaft etc all complete.
10Cost towards dismantling and repairing of complete bowl assembly.
11Cost towards making supplying and fitting S.S. top shaft as per size and sample.
12Cost towards making supplying and fitting of C.I. spider bearing having OD 6.5\\" with rubber bush as per size and sample.
13Cost towards lowering of VT P/Set. After complete repairing and assembling works.
14Cost towards complete repairing of control panel at clear water pump house with changing of damaged parts such as :-1.125 Amp TPN MCCB,50 KA -1 No. as incoming feeder.2. 63 Amp TP MCCB, 50 KA-2No as outgoing feeder.3.Star delta timer-2Nos(One for each starter) 4. 32 Amp switch fuse unit -01 No. for internal and external light load.5. (0-500 v) Volt meter-01 No., Ampere meter-01 No.,Three phase indicator lamp,Powder coating paint,Push Button ON/OFF,ON/OFF/TRIP Indicator lamp,Wiring,etc as per required and testing on full load . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56474924
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 31-07-2026
Authority
Authority Name Drinking Water And Sanitation Department
Work Description Tender for E-Quotation For Seeking Firm Rates For Non-Schedule Items For Preparing Estimates. , Supplying , Installation, Testing And Commissioning Of Vertical Turbine Pump Set With Ss Impeller Capable To Discharge 126 M3/Hr.Against Total Head Of 50 M, (Make Kirloskar/Jyoti/Wilo-Mather&Platt/Wpil) Coupled With Suitable Capacity Vertical Hollow Shaft/Solid Shaft Squirrel Cage Induction Motor , Rating Of Motor 20% More Bhp Than That Of Pump (Make Kirloskar /Abb /Cgl/ Siemens) Operated On 415 +/- 10% Volt, 3 Phase , 50 C/S A.C Supply , Ie3 Type As Per Is:325 And Iec:63400-Ihaving Speed 1450 Rpm,With Heavy Duty M.S. Column Assembly With Ss Line Shaft And Each Coloumn Of 5 Feet Length Including Cost Of Supplying , Fitting And Fixing Of All Required Accessories Such As Cidf Sluice Valve-1 Set, Cidf Nr Valve-1 Set, Pressure Gauge-1 No, Strainer-1 No, M.S. Channel Base Plate Etc. All Complete Including Cost Of Taken Out Existing Old Pumpset. , Supplying And Installation Of Fasd Starter Suitable For Above Mentioned Vt Pumpset Make Lk/Bch/Schneider. , Supplying And Laying Of 25 Mm2 , 1.1 Kv, 3 Core Pvc Insulated Unarmoured Copper Cable Make Polycab/Kei/Gloster, From Starter To Motor. , Supplying, Installation Testing And Commissioning Of Horizontal Split Casing Centrifugal Pump Set With Bronze Impeller Having Discharge 126 M3/Hr. Against Total Head Of 35 M, (Make - Kirloskar/Jyoti/Wilo-Mather&Platt/Wpil), Coupled With Suitable Capacity Squirrel Cage Induction Motor, Rating Of Motor 20% More Bhp Than That Of Pump(Make Kirloskar /Abb /Cgl/ Siemens) ,Tefc, Ie3 Type As Per Is:325 And Iec:63400-Ihaving Speed 1450 Rpm,Operated On 415 +/- 10% Volt, 3 Phase , 50 C/S A.C Supply, Mounted On A Commonm.S. Base Plate Including Cost Of Supplying , Fitting And Fixing Of All Required Accessories Such As Cidf Sluice Valve-1 Set, Cidf Nr Valve-1 Set, Pressure Gauge-1 No, Foot Valve-1No, Etc. All Complete Including Cost Of Taken Out Existing Old Pumpset. , Supplying And Installation Of Fasd Starter Suitable For Above Mentioned C/F Pumpset Make Lk/Bch/Schneider. , Supplying And Laying Of 16 Mm2 , 1.1 Kv, 3 Core Pvc Insulated Unarmoured Copper Cable Make Polycab/Kei/Gloster, From Starter To Motor. , Wiring For Light Point / Fan Point/Exhaust Fan Point With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core In Surface Pvc Conduit, Piano Type Switch, Phenolic Laminated Sheet With Suitable Size Pvc/Ms Box Etc As Required At Pump House At Intake Well And Clear Water Pump House. 15 Point. , Cost Towards Complete Repairing Of Control Panel At Intake Well With Changing Of Damaged Parts Such As :- 1.150 annual periodical maintenance Tpn Mccb,50 Ka -1 No. As Incoming Feeder. 2. 75 annual periodical maintenance Tp Mccb, 50 Ka-2No As Outgoing Feeder. 3.Star Delta Timer-2Nos(One For Each Starter) 4. 32 annual periodical maintenance Switch Fuse Unit -01 No. For Internal And External Light Load. 5. (0-500 V) Volt Meter-01 No., Ampere Meter-01 No.,Three Phase Indicator Lamp,Powder Coating Paint,Push Button On/Off,On/Off/Trip Indicator Lamp,Wiring,Etc As Per Required And Testing On Full Load . , Cost Towards Providing All Labour, Tools And Technicians For Taken Out And Dismantling 40 Hp Vt P/Set With Bowl Assembly, 6 Dia. Coloumn Pipe And Line Shaft Etc All Complete. , Cost Towards Dismantling And Repairing Of Complete Bowl Assembly. , Cost Towards Making Supplying And Fitting S.S. Top Shaft As Per Size And Sample. , Cost Towards Making Supplying And Fitting Of C.I. Spider Bearing Having Od 6.5 With Rubber Bush As Per Size And Sample. , Cost Towards Lowering Of Vt P/Set. After Complete Repairing And Assembling Works. , Cost Towards Complete Repairing Of Control Panel At Clear Water Pump House With Changing Of Damaged Parts Such As :- 1.125 annual periodical maintenance Tpn Mccb,50 Ka -1 No. As Incoming Feeder. 2. 63 annual periodical maintenance Tp Mccb, 50 Ka-2No As Outgoing Feeder. 3.Star Delta Timer-2Nos(One For Each Starter) 4. 32 annual periodical maintenance Switch Fuse Unit -01 No. For Internal And External Light Load. 5. (0-500 V) Volt Meter-01 No., Ampere Meter-01 No.,Three Phase Indicator Lamp,Powder Coating Paint,Push Button On/Off,On/Off/Trip Indicator Lamp,Wiring,Etc As Per Required And Testing On Full Load .
Basic Detail
Tender No DWSMD/RANCHI-03_2026-27_2nd Call
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 15 Jul 2026
Submission Date 31 Jul 2026
Open Date 01 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
BOQ_157049.xls
e40f6ad2-a4f0-4e31-b3d2-bc466149c617.html
TC_NAMKUM2nd.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_157049.xls

html

e40f6ad2-a4f0-4e31-b3d2-bc466149c617.html

pdf

TC_NAMKUM2nd.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders