Tender For Upgrade The Existing Online Stack Monitoring System
Tender Overview
Project Description
Tender for Upgrade The Existing Online Stack Monitoring System , Upgrade The Existing Online Stack Monitoring System , {Instrumentation/ Instrument Store A/C} Sensor For Continuous Stack Emission Monitoring System (Csems) (Im0176) Model - System Dusthunter Sb30/Sp30, Measuring Parameter - Spm, Measured Principle - Forward Light Scattering, Measuring Range - (0 7.5/15/45/75/150/225/375/1,000/3,000 Mg/M3), Unit - Mg/M3, Mg/ Nm3, Process Temp. - Up To 200°C, Ambient Temp. Range - 0°C ... +60°C, Temp. - Up To 200°C, Temp. Measurement - Required For Normalization (Mg/Nm3), Pressure Measurement - Required For Normalization, Process Gas Humidity - Non-Condensing/Condensing As Per Site, Degree Of Protection - Min Requirement Ip66, Approval - Npl With Verification Certificate & Long-Life Validity, International Certification - Tuv Germany, Din En 15267-1 (2009), Din-En 15267-2 (2009), Din En 15859 (2010), Din En 14181 (2014), Product Safety - Ce, Accurate Dust Measurement - Yes, Do (Rs 485 Modbus) - Yes, Ao (4-20 Ma) - Yes, Auto Zero Facility - Yes, Auto Span Facility - Yes, Data Connectivity To Cpcb - Yes, Data Connectivity To Hspcb - Yes, Weatherproof Panel - Yes, Display Unit - Yes, Touch Screen, Make- Endress & Hauser Note- We Require This Npl Certified Sensor For Continuous Stack Emission Monitoring System With Installation Of Ptz Camera Also As Per Cpcb Guidelines. Rates Should Be Inclusive Of Installation/Erection And Commissioning Continuous Stack Emission Monitoring System
BOQ
| Sl. No. | Item Description |
| 1 | Upgrade the existing online stack monitoring system |
| 2 | {INSTRUMENTATION/ INSTRUMENT STORE A/C}SENSOR FOR CONTINUOUS STACK EMISSION MONITORING SYSTEM (CSEMS)(IM0176)Model – System DUSTHUNTER SB30/SP30,Measuring Parameter – SPM, Measured Principle – Forward Light Scattering, Measuring Range – (0 7.5/15/45/75/150/225/375/1,000/3,000mg/m3), Unit – mg/m3, mg/ Nm3, Process Temp. – Up to 200°C, Ambient Temp. Range – 0°C ... +60°C, Temp. – Up to 200°C, Temp. Measurement – Required for Normalization (mg/nm3), Pressure Measurement – Required for Normalization, Process Gas Humidity – Non-Condensing/Condensing as Per Site, Degree of Protection – Min Requirement IP66, Approval – NPL with Verification Certificate & Long-Life Validity, International Certification – TUV Germany, DIN EN 15267-1 (2009), DIN-EN 15267-2 (2009), DIN EN15859 (2010), DIN EN 14181 (2014), Product Safety – CE, Accurate Dust Measurement – Yes,DO (RS 485 MODBUS) – Yes, AO (4-20 mA) – Yes, Auto Zero Facility – Yes, Auto Span Facility – Yes, Data Connectivity to CPCB – Yes, Data Connectivity to HSPCB – Yes, Weatherproof Panel – Yes,Display Unit – Yes, Touch Screen, Make- Endress & HauserNote- We require this NPL Certified Sensor for Continuous Stack Emission Monitoring System with installation of PTZ Camera also as per CPCB guidelines.Rates should be inclusive of installation/erection and commissioning Continuous Stack Emission Monitoring System Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender