Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #56473950

Tender For Repair Replacement Of Main Distribution Boards And Aluminium Conductor Service Cable At Sector 31 And 47 Chandigarh Under Ge (Af) Chandigarh

Issued by Statutory Bodies & Commissions/Committees · Chandigarh, Chandigarh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
14 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Replacement Of Main Distribution Boards And Aluminium Conductor Service Cable At Sector 31 And 47 Chandigarh Under Ge (Af) Chandigarh

BOQ

Name of Work:- REPAIR REPLACEMENT OF MAIN DISTRIBUTION BOARDS AND ALUMINIUM CONDUCTOR SERVICE CABLE AT SECTOR 31 AND 47 CHANDIGARH UNDER GE (AF) CHANDIGARH
Sl. No. Item Description
1Taking down the existing unserviceable main Junction Box ( one incoming and four outgoing etc) any type including making good(i.e plastering ,one coat of putti and two coats of OBD paint with matching existing surface, complete all as specified and directed.
2Taking down the existing unserviceable Concealed DB's any type including fixing plastering and painting of disturbed surface complete all as directed.
3Taking down carefully sub main wiring 6 Sqmm with conduit /Aluminium conductor by cutting plastering of any type complete all as specifed & as directed.
4Supply and fixing in replacement concealed in wall double door sheet metal enclosure DB's for mounting MCB of 240 volt,4 way SPN with 100A rated busbar IP 43 rated, single pole and neutral and fixing in position including copper lugs for cable connection and concealed in wall including making good(i.e plastering ,one coat of putti and two coats of OBD paint with matching existing surface, complete all as specified and directed. Note- All termination in MCB DB by copper Lugs only.
5Supply & Fixing in replacement SPN MCB 240 volt 40 Amps, C curve with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanells etc complete all as specified and directed.
6Supply & Fixing in replacement SP MCB 240 volt 6 to 16 Amps, C curve, with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanells etc complete all as specified and directed.
7Supply & Fixing in replacement SP MCB 240 volt 20 to 32 Amps, C curve, with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanells etc complete all as specified and directed.
8Material and Labour for Concealed in wall sub main wiring with two single core 6 sqmm (Nominal area) PVC Insulated and unsheated cable with stranded copper FRLS conductor in existing Conduit 25mm and its accessories concealed in wall including one run of continuous PVC insulated FRLS copper Stranded cable of wiring size 6 Sqmm for earth continuity including connecting including making good disturbed surface (i.e plastering ,one coat of putti and two coats of OBD paint with matching existing surface), complete all as specified.Note- All termination in MCB DB by copper Lugs only.
9Supply and fixing in replacement concealed in wall double door sheet metal enclosure DB's for mounting MCB of 240 volt,12 way SPN with 100A rated busbar IP 43 rated single pole and neutral and fixing in position including copper lugs for cable connection including making good disturbed surface (i.e plastering ,one coat of putti and two coats of OBD paint with matching existing surface), complete all as specified and directed.Note- All termination in MCB DB by copper Lugs only
10Supply & Fixing in replacement RCBO DP 30mA, 40 Amps with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanells etc complete all as specified and as directed.
11Supply & Fixing in replacement RCBO DP 30mA, 32 Amps with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanells etc complete all as specified and as directed.
12Supply and fixing in replacement FRLS PVC insulated copper conductor Cord cable of Size 10 Sqmm 2 core with cable thimble as required for LT Electric meters etc with necessary connections including UPVC conduit medium grade 25 mm ,concealed in wall Complete including making good disturbed surface (i.e plastering ,one coat of putti and two coats of OBD paint with matching existing surface), complete all as specified and directed.
13Material and Labour in replacement for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal dust (100 kg) and common salt (100 kg) ,vegetable soil (300 kg), including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe upto 7.5 mtr and watering pipe 20 mm dia light grade with funnel and wire mess including necessary earth work i.e Exacavation and removing upto 500 mtr distance with dismantling old earthing, complete all as directed and specified.Note : The earth value/result must be less than 5 ohms.
14Supply and fix RCC Precast (Factory Manufactured) Earthing pit of size 450 mm x 450 mm x 450 mm x 50 mm thickness with Mortar design precast Pit cover with 50 mm thick PCC at bottom including taking down old pit with cover, earth work complete all as specified.
15Supply and Fix 4 MM dia galvanized iron wire for protection of earth GI wire complete all as specified and directed.
16Supply and Fix in replacement 15 mm dia bore G. I. LIGHT grade pipe for protection of earth GI wire complete all as specified and directed.
17Supply and Fix in replacement Galvanized steel flexible conduit with PVC Coating 32 mm dia normal size all as specified and directed .
18Material and Labour for Brick work in CM (1:4) with sub class 'B' bricks straight or curved on plan not exceeeding 6 mtr in height from ground level all as specified and directed.
19Material and Labour for rendering 10 mm thick plaster on brick work/concrete surface in cement mortar (1:4) finished even and smooth including making good disturbed surface (i.e plastering ,one coat of putti and two coats of Apex paint with matching existing surface), complete all as specified and directed.
20Material and Labour for demolition of Brick work straight or curved all as specified and directed.
21Schedule of Credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56473950
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Replacement Of Main Distribution Boards And Aluminium Conductor Service Cable At Sector 31 And 47 Chandigarh Under Ge (Af) Chandigarh
Basic Detail
Tender No CWE/TKD/CHD/TOKEN-19 OF 2026-27
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 15 Jul 2026
Submission Date 05 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
bf21e469-edda-4a98-b5eb-1f50e3b1297b.html
BOQ_872231.xls
CompleteTenderT19.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

bf21e469-edda-4a98-b5eb-1f50e3b1297b.html

xls

BOQ_872231.xls

pdf

CompleteTenderT19.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders