Drinking Water Supply and Sanitation Local Bodies Closing in 6 days TDR #56473919

Tender For Providing Painting And Paver Block For Zonal Office Building Near Stem Park In Ward No : 41

Issued by Local Bodies · Thanjavur, Tamil Nadu
Tender Value
1.60 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
6 days left
EMD
1600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thanjavur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Painting And Paver Block For Zonal Office Building Near Stem Park In Ward No : 41

BOQ

Name of Work:- Providing Painting and Paver Block For Zonal Office Building Near Stem Park In Ward No : 41
Sl. No. Item Description
1Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
2Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
3Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approveddesign i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984.
4Supplying and laying Rubberised interlocking Paver block M40 grade Providing and laying of 63mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with sand cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, sand cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
5Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
6Painting two coats for Interior surface with approved Interior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
7Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56473919
AUTHORITY Local Bodies
TENDER VALUE 1.60 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Providing Painting And Paver Block For Zonal Office Building Near Stem Park In Ward No : 41
Basic Detail
Tender No 5678_3/2026/MCE5
Bidding Type Tender
Location
City Thanjavur
State Tamil Nadu
Key Dates
Publish Date 15 Jul 2026
Submission Date 05 Aug 2026
Open Date 05 Aug 2026
Finance
Tender Value 1.60 Lakhs
Tender Fee Ref. Documents
EMD 1600
Exemption Not Available
Document List
15e90cbd-7013-4fa2-b1c9-74032fa3bd71.html
BOQ_824518.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

15e90cbd-7013-4fa2-b1c9-74032fa3bd71.html

xls

BOQ_824518.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders