Tender For Repair/Replacement Of Solar Water Heater Lighting Arrester And Other Connected Works At annual maintenance contract And Other Otm Accn Under Area Of Age Yard-Ii Under Ge (East) Lucknow
Tender Value
40 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
16 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Solar Water Heater Lighting Arrester And Other Connected Works At annual maintenance contract And Other Otm Accn Under Area Of Age Yard-Ii Under Ge (East) Lucknow
BOQ
| Sl. No. | Item Description |
| 1 | M&L for disconnection of electric supply and water supply pipe line of solar water heater/ collector plates of any size from site for repair/ overhauling/ replacement of unserviceable parts incl nut and bolts with washers and refixing the same in serviceable condition after assembling , testing and re connecting the electrical and water supply line complete. |
| 2 | S&F in replacement of heating element 3 KW, suitable for solar water heater(ISI marked) all as per sample complete. |
| 3 | Taking down old tank and M&L for replacement of old unserviceable 200 LPD hot water tank fully insulated complete. |
| 4 | Taking down old tank and M&L for replacement of old unserviceable 100 LPD hot water tank fully insulated complete. |
| 5 | M&L for descaling of pipe line with chemical powder and liquid (4 Kg each) of solar collector plates, solar water heating tank complete. |
| 6 | M&L for replacement of old unserviceable collector glass panel with heating resistant glass panel of size 2.08 Mtr x 1.01 Mtr of thickness not less than 8 mm incl cleaning of broken glass suitable for 100/ 200 ltrs solar tank complete . |
| 7 | M&L for replacement of old unserviceable collector panel tube used for solar water heater based on in directed transfer of heat of capacity 100 LPD complete. |
| 8 | M&L for welding/ grazing work of rusted/ leakage portion of complete set of collector panel including metal/ GI pipe where necessary. |
| 9 | Taking out old U/S insulated pipe and Supply & fix Hot water pipe duly insulated with glass wool and aluminium cladding suitable for 15 mm galvanised iron tubing with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site complete. |
| 10 | All as above item No 9 but 20mm dia |
| 11 | Taking out old U/S pipe and Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed for 20 mm bore |
| 12 | Taking out old U/S pipe and Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed for 15 mm bore |
| 13 | Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete except fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete. |
| 14 | Material and labour for one light / fan point/bell controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick Hylem laminated sheet top cover, steel screws, cup washers etc and making good to the disturbed surfaces to match the existing complete . |
| 15 | Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC casing caping of 20/25 mm thick or higher, medium grade complete with and including all accessories surface in wall/ roof and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick Hylem laminated sheet top cover, steel screws, cup washers etc and making good to the disturbed surfaces to match the existing complete. |
| 16 | All as per serial item No 15 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp complete. |
| 17 | All as per Serial Item No 15 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 5/15 Amp socket out let point controlled by one, one way switch on independent board complete. |
| 18 | Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal modular box of 1.00 mm thick suitable type etc and making good to the disturbed surfaces to match the existing complete . |
| 19 | Taking down OLD U/S Switch/socket/Ceiling rose/calling bell/bell push/lamp holder/Regulator any type and size complete. |
| 20 | S&F Switch Modular 6A single pole, one way, 1 module complete . |
| 21 | S&F Switch Modular 16A single pole, one way, 1 module complete. |
| 22 | S&F Socket, 6A - 2/3 pin combined 2 module complete . |
| 23 | S&F Socket 6A/16A - 2/3 pin combined 2 module complete. |
| 24 | S&F Modular White cover plate with frame,18 module complete. |
| 25 | S&F White cover plate with frame,12 module complete. |
| 26 | S&F Modular White cover plate with frame,8 module complete . |
| 27 | S&F Modular White cover plate with frame,6 module complete. |
| 28 | S&F Modular White cover plate with frame,4 module complete. |
| 29 | S&F Modular White cover plate with frame,3 module complete. |
| 30 | S&F Modular White cover plate with frame,2 module complete. |
| 31 | Supply and fixing fan step regulator, 120W 2 module Modular type complete. |
| 32 | Supply and fixing switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete . |
| 33 | Supply and fix socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete. |
| 34 | Supply and fixing switch socket combination outlet 2 in 1, 5 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete. |
| 35 | Supply and fixing electronic ceiling fan regulator piano type with rotary step, two module, humfree, AC, 240 volt, 100 Watt and duly ISI marked complete . |
| 36 | Supply and fixing lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete. |
| 37 | Supply and fixing electronic ceiling fan regulator Modular type 1/2 module suitable for BLDC ceiling fans, AC, 240 volt, 100 Watt and duly ISI marked complete . |
| 38 | Supply and fix Capacitor 2.5 MFd for ceiling fan of any size and exhaust fan of size 300/230mm cabin fan any Sweep complete. |
| 39 | Supply and fixing electronic ceiling fan regulator PCB suitable for BLDC ceiling fans, AC, 240 volt, and duly ISI marked complete. |
| 40 | Supply and fixing replacement of decorative wall mounting type light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9/10 Watts lamp B22 CDL etc and all accessories pre-wired including connecting up complete . |
| 41 | Supply and fix in replacement of integrated bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete . |
| 42 | S&F in replacement of unserviceable wire of size 1.5 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete. |
| 43 | S&F in replacement of unserviceable wire of size 2.5 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete. |
| 44 | S&F in replacement of unserviceable wire of size 4.0 Sqmm single core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete. |
| 45 | S&F in replacement of unserviceable wire of size 2.5 Sqmm three core with PVC insulated unsheathed FRLS multistranded copper conductor for working Voltage 1100 Volts for gate light connection complete. |
| 46 | S& F in replacement of in factory made Pantone 7541C shade powder coated distribution board SPN 4 way double door fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts complete. |
| 47 | Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 08 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete and comprising of the following:- (a) MCCB, 200 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 40 Amp, \\"C\\" curve, 10 KA breaking capacity - 12 Nos. |
| 48 | Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 40 Amp, \\"C\\" curve, 10 KA breaking capacity - 08 Nos. |
| 49 | M&L in replacement of SP MCB 6 TO 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity complete. |
| 50 | M&L in replacement of MCB Single Pole & Neutral MCB 32 Amps, 240 v, 50 Hz AC Made from moulded self extinguishing thermostat plastic and suitable for 'C' curve, 10KA breaking capacity complete. |
| 51 | Supply and fixing building security light of 45 W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaire shall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete. |
| 52 | Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete. |
| 53 | Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete . |
| 54 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete. |
| 55 | M&L in factory made Pantone 7541C shade powder coated distribution board SP & N 12 way double door fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates complete . |
| 56 | M&L in factory made Pantone 7541C shade powder coated distribution board SP & N 8 way double door fabricated of CRCA sheet with metal door (IP-43 protection) bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates complete. |
| 57 | S & F Laminated sheet cover hylam ISI marked 3mm thick including cutting of sheet for fixing switches/sockets as required at site incl suitable size screws - 04 Nos for fixing on existing MS sunken boxes complete of size 8'' x 5'' . |
| 58 | All as per item No 57 but of size 7'' x 4''. |
| 59 | All as per item No 57 but of size 5'' x 5''. |
| 60 | All as per item No 57 but of size 8'' x 10''. |
| 61 | All as per item No 57 but of size 12'' x 10''. |
| 62 | Repair and serviceing of electric chimney incl with spare parts like motor, heavy duty duct pipe PCB, sensor display etc. complete. |
| 63 | Supply and fix copper strip of size 20 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground level complete. |
| 64 | Supply and fix Aluminium strip of size 20 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground level complete. |
| 65 | Supply and fix Air Termination, single pointed copper rod 12mm dia and 300mm long complete . |
| 66 | Supply and fix epoxy insulator with red colour incl with nut and bolt suitable for fixing size of strip 25 X 3.15 mm complete . |
| 67 | Supply and fix Test Point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexognal head screw complete . |
| 68 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI strip 25 x4 mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 40 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender