Tender For Comprehensive Maintenance Of Swimming Pool, Filtration Plant, Stps, Solar Water And Connected Works Under Ge (I) Kanpur
Tender Value
40 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
20 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Maintenance Of Swimming Pool, Filtration Plant, Stps, Solar Water And Connected Works Under Ge (I) Kanpur
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) Kanpur Name of Work : COMPREHENSIVE MAINT OF SWIMMING POOL, FILTRATION PLANT, STPs, SOLAR WATER AND CONNECTED WORKS UNDER GE (I) KANPUR Contract No : GE(I)/KAN/T-52 OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Items/Works Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Maintenance of station swimming pool including brushing the inside the entire pool having bottom area 400 Sqm, side wall having an area 300 Sqm, 100 meter long scum channel and having 250000 gallons entire capacity of water. Filter capacity of the pool is 150 Cum/Hour with pressure type pumps of capacity 5 HP and having chlorine plant to maintain 2 PPM of chlorine in the pool water and PH level between 7 to 8 all over complete all as specified and directed including the followings:- (i) Suction sweeping the bottom of the entire pool two time in a day by a trained operator by using suction sweeping pump set connected with 40 mm size flexible rubber hose and tied with 12 mm nylon rope to the handles on either side for moving the sweeper in all direction for removing sediment.(ii) Removing all floating particles by using net in a regular interval of one hours. (iii) Feeding of chemicals in required proportion on Sunday/Monday as per requirement of swimming pool. |
| 3 | Supply & fixing 6'' check valve inside balancing tank complete with fittings complete all as specified and directed. |
| 4 | Supply only flexible hose pipe ribbed type high density of 40 mm size complete all as specified and directed. |
| 5 | S&F nylon brush with superior quality of size as sample made out of water resistant wooden block with thickly insert nylon strings for using sweeping complete all as specified and directed. |
| 6 | S&F nylon rope 12 mm for the suction sweeper complete all as specified and directed. |
| 7 | S&F aluminimum alloy telescopic rod , top dia 30mm and bottom dia 28 mm with detachable superior quality brush ISI marked of size 6 mtr expanded upto 12 Mtr for brushing the entire area of swimming pool complete all as specified and directed. |
| 8 | M&L for poly aluminimum cloride (PAC) COAGULANT CONTAINING APPROX 29% Al2O3 with bacity of approx 64% packed complete all as specified and directed. |
| 9 | Supply & Pouring Sodium Hypo Cloride having chlorine content (10-11%) in manufacturer standard packing complete all as specified and directed. |
| 10 | Supply & mixing Copper Sulphate complete all as specified and directed. |
| 11 | Supply & Pouring Soda Ash complete all as specified and directed. |
| 12 | Supply & Pouring Chemi coat, Algae-cide liquid for swimming pool complete all as specified and directed. |
| 13 | Supply and fixing in replacement High pressure guage circular dial up to 5 Kg/Sq.cm confirming to IS complete all as specified and directed. |
| 14 | Supply only Ortho- Toliding solution for testing of disolved chlorine in water complete all as specified and directed. |
| 15 | Supply and fixing in replacement superior quality detachable type telescopic brush suitable for telescopic rod of 30mm dia (bottom 28mm dia) complete all as specified and directed. |
| 16 | Supply and fixing in replacement leaf net for removing floating particles from both swimming pool surface every day in the morning and evening time complete all as specified and directed. |
| 17 | Supply only chlorine testing kit comprising of samples of chlorine contents in seald tube from 0.1 to 2.0 PPM and othotodoline solution, testing tube complete all as specified and directed. |
| 18 | Supply & Pouring Calcium based high strength granular chlorination chemical having 65 % to 70 % active chlorine, whitish, free flowing, decomposes clear in water solution , free of foriegn matter , the chlorination chemical should contain appropriate quantities of dispersants, corossion inhibitors to prevent incrustation scaling in distribution systems, mercury and other heavy meatl conteminents in chlorination chemical must be Below Detectable Limit (BDL) complete all as specified and directed. |
| 19 | S&F of high rate pressure sand filters bobbin wound fibre glass reinforced laminated filter of 1200 mm with UV resistant surface finish, reliable to operate under prolong sunlight for years, designed for easy inspection of quartz filter media with a six position, 50 mm multiport valve and ABS lateral with quartz filter media complete with all required materials incl dismantling of old, all materials as required at site, fixing arrangements and testing on completion all as specified and directed. Mkae : HIBIRD or Equivelent. |
| 20 | M&L in replacement of swimming pool pump having discharge 300 LPM Head 16 mtr voltage 415 volt 50 Hz 2.2KW/3 HP Iincluding required fittings complete all as specified and directed. |
| 21 | Supply & fixing in replacement sluice valves 150 mm dia class PN-1.6 , IS-14846 with flanged ends, stainless steel spindle and iron wheel including nut bolts and rubber packing complete all as specified and directed. |
| 22 | S&F in replacement of 150 mm bore non return valve both end flanged suitable for cast iron pipe including all fittings washer, nuts & bolt etc complete all as specified and directed. |
| 23 | S&F in replacement of MCCB 4 pole 415V adjustable type 200 Amp with breaking capacity 36 KA with Ics =100% Icu complete all as specified & directed. |
| 24 | S&F in replacement of MCCB 4 pole 415V adjustable type 100 Amp with breaking capacity 16 KA with Ics =100% Icu complete all as specified & directed. |
| 25 | S&F in replacement of MCCB 4 pole 415V adjustable type 63 Amp with breaking capacity 16 KA complete all as specified & directed. |
| 26 | S&F in replacement of DP isolator 63 Amp complete all as specified & directed. |
| 27 | S&F in replacement of Contactor LA1D11 of existing make complete all as specified & directed. |
| 28 | S&F in replacement of swimming pool pump round copper cable 4 sqmm 4 core complete all as specified & directed. |
| 29 | Servicing / maint of solar water heater system of capacity up to 750 ltr including dismantling the required parts after that de-scaling, cleaning of water tank, cleaning of pipe, air vent, eliminator etc and refixing the dismantled parts at its original position to make solar water heater functional complete by replacement of minor accessories and testing on completion all as spfd and directed. (i) Minor spares i.e nut, bolt, washers, wire or other minor parts if required shall deems to be included in this job. (ii) Any accessories found unserviceable that shall be replaced & paid under respective items of this Sch. |
| 30 | S&F in replacement PVC hose pipe for Solar water heating system as per sample including clamps, washers, bolts etc where ever reqd complete all as specified and directed. |
| 31 | S&F in replacement of thermostat with connected fittings complete all as specified and directed. |
| 32 | S&F in replacement of air vent valve complete all as specified and directed. |
| 33 | S&F in replacement of drain valve complete all as specified and directed. |
| 34 | S&F in replacement of shutt off valve complete all as specified and directed. |
| 35 | Supply & Laying, jointing and leakage testing 3 layer (inner antimicrobial outer UV Stabilized) ISI Marked , IS- 15801 PP-R pipes SDR 7.4 (PN-16) 20 mm outer dia with all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches/floor/walls and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate/ plastering in CM 1:4 and applying finishing coat of existing treatment) complete all as specified and directed. Notes :(i) The laying and jointing of pipes are required to be carried out in short / long streches catering to specific requirements of a purticular quarter or a group of blocks. (ii) Excavation & earth work shall be measured & paid seperately. |
| 36 | S&F 20 mm dia stop valve chromium plated cast copper alloy, fancy type high pressure with capstan head screwed both ends for iron / PP-R pipe or for union complete all as specified and directed. |
| 37 | S&F Solar Flat Plate Collector OF Selective Black chrome with Nickel Undercoat absorber, Italian design, (screw less construction for durability) Copper riser tube dia 12.5mm x 0.55mm thick, 9 risers, Copper header tube dia 25.4 mm x 0.72mm thk x 1120 mm length, Toughened glass 4mm thick transmittance up to 87%, Aluminum-PU coated frame, Box Type Structure body, Glass wool and Rock wool insulation, Back Insulation - 50mm thick, Side Insulation - 25mm thick, 48 Kg/Mtr cube insulation density, Stainless Steel - SS 304L, having 6 bar pressure complete all as specified and directed. |
| 38 | S&F in replacement of SS-304 pressurized tank 300 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. |
| 39 | S&F in replacement of SS-304 pressurized tank 500 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. |
| 40 | S&F in replacement of SS-304 pressurized tank 750 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. |
| 41 | S&F in replacement of ETC tube size 58mm x 1800 mm solar water collector complete all as specified and directed. |
| 42 | S&F in replacement of ETC tube size 58mm x 2100 mm solar water collector complete all as specified and directed. |
| 43 | S&F in replacement of ETC Coupler flange set complete all as specified and directed. |
| 44 | S&F rotational moulded polyethylene water storage tanks, 250 capacity (cylindrical veryical with closed top) hoisted and fixed in position all as specified in SSR Part I, including MS stand of suitable size as per recommendations of solarwater heater, including two coats of anticorrosive paint over and including a coat of anti corrosive primer complete all as specified and directed. |
| 45 | S&F in replacement of Mild steel framed/sheet work for tanks/panel/pump cage supported structure/ladder and similar works conforming to Fe-290 Gde-E-165 including welding/cutting of steel including painting of two coats of synthetic enamel paint over one coat of primer paint (incl preparation of surface) complete all as specified and directed. |
| 46 | S&F in replacement of change over switch on load 415 volt in sheet metal enclouser 4 pole of capacity 125 Amps incl disconnecting and dismantling old and fixing on wall making electric connection with existing cable complete all as specified and directed. |
| 47 | M&L for hot lagging and wrapping on GI / PP-R pipe used in internal plumping work all around with bonded mineral wool performed snap on pipe section of density 144 Kg / cum conforming to IS 9842 and covered with required size of glass wool and aluminium cladding of required size for up to 20 mm bore pipe complete all as specified and directed. |
| 48 | S&F heating element 1500/2000 watt capacity suitable for solar water heater push / screw type as per sample with 'O' ring including making electrical connection complete all as specified and directed. |
| 49 | M&L for fixing glass wool insulation for Hot water pipe complete all as specified and directed. |
| 50 | S&F in replacement of air eliminator complete all as specified and directed. |
| 51 | Taking / lifting out defective submersible type raw sewage pumps set of capacity 1.1 KW/2760 RPM from raw sewage sump with column pipe steel rope, submersible cable and accessories, including cleaning, greasing , oiling of bearing of electric motor, impeller shaft and relowering the same after repairing works including replacement of worn out parts as per requirement and testing complete all as specified and directed. |
| 52 | M&L for rewinding of submersible type sewage motor 1.1 KW/2760 RPM with existin same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc including cleaning and replacement of defective parts complete all as specified and directed. |
| 53 | Taking out defective Air blower with motor of capacity 3 KW/1400 RPM complete with all accessories, including cleaning, greasing,oiling of bearing of electric motor and refixing including cleaning, greasing , oiling of bearing of electric motor, impeller shaft and commissioning the same after repairing works including replacement of bearing and testing complete all as specified and directed. |
| 54 | M&L for rewinding of Air blower motor of capacity 3 KW/1400 RPM with existin same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc. including cleaning and replacement of defective parts complete all as specified and directed. |
| 55 | Supply and replacement of air filter for air blower of capacity 3 KW as per existing pattern/make complete all as specified and directed. |
| 56 | Taking out defective Monoblock centrifugal pump set of capacity 5.5 KW/1500 RPM complete with all accessories including cleaning, greasing , oiling of bearing of electric motor and refixing the same after repairing works including replacement of worn out parts as per requirement and testing complete all as specified and directed. |
| 57 | Supply and fixing of Contactor Model No MNX-12 making proper connection with suitble lugs complete all as specified and directed. |
| 58 | S&F MCB SPN 240 volts 40 Amp including connection with suitable size aluminium / copper lugs complete all as specified and directed. |
| 59 | M&L for earthing complete with GI plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified and directed. |
| 60 | M&L for cleaning raw sewage chamber and cleaning all foreign Materials complete all as specified and directed. |
| 61 | M&L for draining out sewage water from Fludized Aerobic Bed (FAB) reactor and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. |
| 62 | M&L for drain out sewage water from Tube settler tank and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. |
| 63 | M&L for drain out sewage water from treated water tank and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. |
| 64 | M&L for cleaning of bushes shrubs, grass around out side of STP upto 2 meter between fencing & road complete all as specified and directed. Note : Necessary tools for cleaning will be arranged by the contractor with out any extra cost. |
| 65 | M&L for plastic filter media for enhanced bacterial development in filter tank used in STP plant complete all as specified and directed. |
| 66 | Removing of dried sludge from sludge drying bed and depositing the same at a distance of not less than 200 mtr from plant complete all as specified and directed. |
| 67 | Supply and replacement of butter fly valve of size 50 mm bore ISI marked heavy duty including suitable nut,bolt & washer complete all as specified and directed. |
| 68 | Supply and filling of oil ENKLO 320 or equivalent for air blower of capacity 3 KW complete all as specified and directed. |
| 69 | M&L for testing of treated water of STP (Monthly) from authorised laboratory and submit the report timely complete all as specified and directed. Make - Bharat test House/CIMEC/Spectro or equivalent lab approved by GE. |
| 70 | M&L for painting of steel and iron surfaces with one coat of synthetic enemelled paint after preparation of old painted surfaces complete all as specified and directed. |
| 71 | S&F in replacement of copper cable round core 2.5 sqmm 3 core for complete all as specified and directed. |
| 72 | S&F in replacement LED flood light 210 watt , die cast aluminium housing with LEDs as light source suitable for highlighting architectural features or area lighting including fixing arrangements i.e suitable clamps, nut, bolt and washers complete all as specified and directed. |
| 73 | Supply and laying in trenches or fixing to wall/pole or passing through pipe XLPE insulated heavy duty electric cable with armoured aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification) complete all as specified and directed. |
| 74 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays and for rerouting of cables complete all as specified and directed. |
| 75 | Returning filling including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed. |
| 76 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 77 | M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.Note:- Punned thickness shall be measured and paid. |
| 78 | M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed. |
| 79 | M&L in replacement of filter media required for ACF & DMF Filter complete all as specified & directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender