Tender For Providing Additional Wiring For Ac, Geyser Points And Electrical Safety Check At Residential Buildings And Maintenance Of Motors In Kalpakkam Township During The Year 2026-2027.
Tender Value
40.50 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
19 days left
EMD
81000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chengalpattu → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Additional Wiring For Ac, Geyser Points And Electrical Safety Check At Residential Buildings And Maintenance Of Motors In Kalpakkam Township During The Year 2026-2027.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+) Less (-) Tender Inviting Authority: Chief Engineer, Engineering Services Group, GSO, Kalpakkam. Name of Work: Providing additional wiring for AC, Geyser points and Electrical Safety check at Residential buildings and Maintenance of Motors in Kalpakkam Township during the year 2026-2027. Tender No: GSO/CTC/ESD/349/2026 Name of the Bidder/ Bidding Firm / Company : PART-II (FINANCIAL BID) Note : 1) This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. 2) Bidders are allowed to enter the Bidder Name and Values only.3) Rates quoted should be inclusive of GST @ 18% and any other taxes as applicable. NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Item.No. Item Description Item Code / Make Quantity Units Estimated RateinRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE including all taxes in Figures to be entered by the Bidder inRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Rates in words Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Unit for Rate TOTAL AMOUNT Without Taxes in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29) |
| 3 | 25 x 12 mm size of PVC Mini trunking |
| 4 | Supply, installation, testing and commissioning of 20A 3kA C series SP Mini MCB, 16A Socket (Heavy Duty), 16A 3 Pin Plug top (Heavy Duty) on 3 Modular plate, including supply and embedment of 3Modular PVC Box as per the detailed specification. |
| 5 | Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply and installation of wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18) |
| 6 | Wiring for Power Points with 2 Run of 4.0 Sq. mm Copper Wire for Phase, Neutral and 1 Run of 2.5 Sq.mm for Earthing. (Quantity indicated is total running length of 3 Runs of Wires) as per the detailed specification. |
| 7 | Wiring with 2 Runs of 6.0 Sq.mm Copper wires for Phase, Neutral and 2 Runs of 2.5 Sq.mm Copper wires for Earth from Energy Meter Distribution Boards to SPN Distribution Boards (Quantity indicated is total running length of 4 Runs of Wires) as per the detailed specification. |
| 8 | Carrying out Healthiness check of RCCB,MCB in TPN/SPN 12/8/6 way DB at residential quarters as per the detailed specification and as directed by the Engineer-in-charge. |
| 9 | Type A & B |
| 10 | Type C & D |
| 11 | Type E |
| 12 | Providing and fixing of CERAMIC tile of size 300X300 ofJohnson/KAJRIA/ of approved patter/shade for closingthe junction box at staircase landing or other area asper the detailed specification and as directed by theEngineer-in-charge.(as per section-VI(MNC), clauseNo: 17.3) |
| 13 | Supply and installation of following sizes of Heavy Duty, PVC circular rigid Conduits for Electrical & Communication System with required Solid Long Bends, Couplings, GI Wire etc, in Floor, Walls, Brick, Block Masonry, etc. including chasing & replastering as per the detailed specification.(Refer Sec VI, Clause No.27). and as directed by Engineer Incharge |
| 14 | 25mm Dia, 2mm wall thickness PVC heavy duty round rigid conduits with 50mm deep Junction boxes |
| 15 | Removal of existing Aluminimum / Copper wires from ERW Conduit embedded on wall in staicase area and laying of removed wires in to the PVC Conduits (Set of Phase, Neutral and earth wires from Energy Meter Distribution Boards to SPN Distribution Boards) |
| 16 | Supply and embedment of 200 mm x 150 mm x 75 mm size Teakwood Pull Box including chasing of wall, finishing and curing etc. Complete all as per the detailed specification and as directed by Engineer Incharge |
| 17 | Supply and installation of 12 Volts, 9AH Lead Acid battery as per specifications and as directed by the Engineer-in-Charge. |
| 18 | Supply and painting One coat on metallic surfaces of electrical equipment and other required surface at all levels with primer and following paint (Asian or approved brand, colour and manufacturer) to give an even shade including preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-Charge. (Refer Sec VI (MNC), Clause No.3). |
| 19 | Synthetic enamel Paint |
| 20 | Supply, open installation testing and commissioning of the following DB with Double Door consisting of Phase, Neutral and Earth Bus and interconnecting wires. (Refer Sec VI, Clause No.15.2). and as directed by the Engineer-in-charge. |
| 21 | DB SPN 12 Way (12) WITH METAL DOOR IP 43 - IK 09cat No: 507612 or equivalent |
| 22 | Supply, installation and testing of 10 Watts (max), 1100 lumen LED Bulkhead Luminaires with integrated driver unit made of aluminium as per the detailed specification. |
| 23 | Supply fixing testing and commissioning of the following RCCBs on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2) |
| 24 | RCCB DP 63A sensitivity 30mA , TYPE Hpi |
| 25 | Supply Installation testing and commissioning of the following MCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2). |
| 26 | 6-32 Amps SP MCB (Type-C) |
| 27 | 40-63 Amps DP MCB (Type-C) |
| 28 | Maintenance of Motor Control centres /Distribution Centres, LT panels/TPN switch Fuse Units (Refer Sec VI (MNC), Clause No.17.2). |
| 29 | Cubicle switch boards having number of vertical sections up to 3 |
| 30 | Cubicle switch boards having number of vertical sections more than 3 |
| 31 | Preventive maintenance of LT Motors ( 3 HP to 25HP motor) |
| 32 | Combination Switch fuse Units/ MCB from 32 A to 125 A / Motor starters |
| 33 | Cleaning of Motor Control Centres / Distribution Centres, LT Panels / TPN Switch Fuse Units / Squirrel Cage Induction Motors / Motor Starters as per the Specification and as directed by Engineer-in-charge |
| 34 | MCC Panel & Panel room |
| 35 | Control Panel & Panel room |
| 36 | Motor Starters units fixed on wall |
| 37 | Squirrel Cage Induction Motors ( Up to 25 HP ) |
| 38 | Motor Junction boxes |
| 39 | Attending to break down calls for following types of Motors as per the scope of work . (Refer Sec VI (MNC), Clause No.15). |
| 40 | Single phase Motors up to 2 HP |
| 41 | 3 Phase Motors from 3 HP to 12.5 HP |
| 42 | 3 Phase Motors from 15 HP to 35 HP |
| 43 | 3 Phase Motors from 40 HP to 75 HP |
| 44 | Overhauling, Painting and test running of the following Single/Three phase motors as per the scope of work. (Refer Sec VI (MNC), Clause No.14.1) |
| 45 | Fraction HP Motors up to 0.5HP Motor |
| 46 | Above 0.5 HP to 2.0 HP Motor |
| 47 | 3.0 HP/5.0 HP Motor |
| 48 | 7.5 HP/10.0 HP Motor |
| 49 | 12.5 HP/15.0 HP |
| 50 | 20.0 HP/25.0 HP |
| 51 | 30.0 HP/35.0 HP/40.0 HP Motor |
| 52 | 50.0/60.0 HP/75.0 HP Motor |
| 53 | Rewinding of the following LT motors as per the scope of work (Refer Sec VI (MNC), Clause No.11.2). |
| 54 | Fractional HP Motors upto 0.5 HP Motors |
| 55 | Above 0.5 HP and Upto 2HP Motors |
| 56 | 3 HP Motor |
| 57 | 5 HP Motor |
| 58 | 7.5 HP Motor |
| 59 | 10 HP Motor |
| 60 | 12.5 HP Motor |
| 61 | 15 HP Motor |
| 62 | 20 HP Motor |
| 63 | 25 HP Motor |
| 64 | Complete Rewinding, Machining, Replacement of Bush Bearings, Thrust Bearings, Oil Seals, Dismantling & Assembling, Testing and Commissioning of following 3 Phase , 415V, Submersible Motors as per the Specification and as directed by Engineer-in-charge |
| 65 | 1.0 HP Submersible Motor |
| 66 | 2.0 HP Submersible Motor |
| 67 | 5 HP Submersible Motor |
| 68 | 7.5 HP Submersible Motor |
| 69 | 10 HP Submersible Motor |
| 70 | 15 HP Submersible Motor |
| 71 | 20 HP Submersible Motor |
| 72 | 25 HP Submersible Motor |
| 73 | Synthetic enamel Painting of the Fractional HP to 25 HP Induction Motor as per the detailed specification and as directed by the Engineer-in-Charge. |
| 74 | Fractional HP to 2 HP Motor |
| 75 | 3 HP to 7.5 HP Motor |
| 76 | 10 HP to 25 HP Motor |
| 77 | Machining and building up of damaged / worn-out Motor Shaft and Bearing housing in end cover as per the detailed specification. |
| 78 | From 3.0 to 10.0 HP Motor |
| 79 | From 12.5 to 25.0 HP Motor |
| 80 | Supply, replacement and testing of the following items as per detailed specification. |
| 81 | HRC Fuse Link 63 A to 125 A DIN Type HN Size 00 or Equivalent |
| 82 | HRC Fuse Link 250 A DIN Type HN Size1 or Equivalent |
| 83 | HRC Fuse Link 2A to 32 A Cyclindrical Type HF or Equivalent |
| 84 | HRC Fuse Link 63 A Cyclindrical Type HF or Equivalent |
| 85 | HRC FUSE Link 4A to 10 A TYPE HG or Equivalent |
| 86 | LED Indication Lamp Except Blue & White, 240V AC |
| 87 | LED Indication Lamp Blue & White 240V AC |
| 88 | ON / OFF Push button with NO / NC Element ( Green / Red) |
| 89 | 10-80 mfd, 240/440V PVC polypropylene industrial type Capacitor for single phase motor |
| 90 | 125A ,1000V Connector ( CSTSN6U) |
| 91 | DOL Starter ,415V, 5 HP |
| 92 | Supply and replacement of the following contactors, VFD Drive and accessories (Refer Sec VI (MNC), Clause No. 4) . as per detailed specification and as directed by the Engineer-in-charge. |
| 93 | Control Contactor, AC-15 Rating MX0 - 22E ( 2 NO + 2 NC ) |
| 94 | Power Contactors, AC3 Rating MNX 3Pole 25A |
| 95 | Power Contactors, AC3 Rating MNX 3Pole 32A |
| 96 | Power Contactors, AC3 Rating MNX 3Pole 40A |
| 97 | Power Contactors, AC3 Rating MNX 3Pole 70A |
| 98 | 3pole Power Contactor (AC3) type ML1.5, 25A |
| 99 | Bimetal over load relay (6 to10 / 9 to 14)A for direct mounting on MK1 type contactor. |
| 100 | Bimetal over load relay (13-21)A for direct mounting on ML type contactor. |
| 101 | Bimetal over load relay (6-10)A for direct mounting on MNX type contactor. |
| 102 | Bimetal over load relay (9-15)A for direct mounting on MNX type contactor. |
| 103 | Bimetal over load relay (14-23)A for direct mounting on MNX type contactor. |
| 104 | Bimetal over load relay (20-33)A for direct mounting on MNX type contactor. |
| 105 | Type: MPR 300 or equivalent of range (8-22)A standrad range or equivalent. |
| 106 | Auxiliary Contact (2NC + 2 NO) for 3 phase, 415 Volt Motor Starter |
| 107 | Electronic Timer suitable for Automatic Star Delta Starter with Timing Range: 3 sec to 120 sec, Voltage: 240 - 415 V AC with 1 NO (Star) + 1 NO (Delta) as per the detailed specification and as directed by Engineer-in-charge |
| 108 | 415 Volts Supply Monitoring Device, (Single Phase Preventer with under votage) |
| 109 | Supply and replacement of the following VFD Drive, as per the detailed specification and as directed by the Engineer-in-charge. |
| 110 | VFD Drive, 415 V , 5.5 KW |
| 111 | VFD Drive, 415 V , 15 KW |
| 112 | VFD Drive, 415 V , 30 KW |
| 113 | Supply and Installation of LT panel accessories as per the detailed specification |
| 114 | Mettalic Panel Lock |
| 115 | Mettalic Panel key |
| 116 | Supply and Installation of 8SWG GI wire including excavation and refiling as per the detailed specification |
| 117 | Supply, cleaning the floor, proper pasting and installation of following insulating mat as per specification. (Refer Sec VI, Clause No.25). |
| 118 | 2.0 mm thickness, Max useable voltage 3.3kV, AC Proof voltage 10kV for 3 minutes, AC dielectric strength 30kV RMS Insulating Mat confirming to IS:15652 |
| 119 | Supply and replacement of following Motor Bearings during overhauling (Refer Sec VI (MNC), Clause No.14). |
| 120 | Bearing Model No:6204 2Z or equivalent |
| 121 | Bearing Model No:6206 2Z or equivalent |
| 122 | Bearing Model No:6208 2Z or equivalent |
| 123 | Bearing Model No:6302 2Z or equivalent |
| 124 | Bearing Model No:6304 2Z or equivalent |
| 125 | Bearing Model No:6306 Z or equivalent |
| 126 | Bearing Model No:6307 Z or equivalent |
| 127 | Bearing Model No:6308 Z or equivalent |
| 128 | Bearing Model No:6310 2Z or equivalent |
| 129 | Bearing Model No:6312 2Z or equivalent |
| 130 | Bearing Model No:6314 or equivalent |
| 131 | Preventive Maintenance in tower blocks/ Residentialquarters as per the detailed specification and asdirected by Engineer-in-charge. |
| 132 | Full House Maintenance of Type A / B / C / SA typeResidential Quarters (Entire House).(as per section-VI(MNC), clause No: 17.3) |
| 133 | Full House Maintenance of Type D / E ResidentialQuarters (Entire House).(as per section-VI(MNC),clause No: 17.3) |
| 134 | Supply and Installation of following Wiring Accessories as per the detailed specification (Refer Sec VI (MNC), Clause No.5) |
| 135 | 1 No 20 Amps SP C MINI MCB suitable in modular plateand termination of wires to the MCB |
| 136 | 1 Modular dummy plate |
| 137 | Supply and fixing following Modular front cover plate on existing modular metal boxes etc. as required. (Refer Sec VI, Clause No.15.7). and as directed by Engineer Incharge |
| 138 | One/Two module |
| 139 | Supply and Embedment of 50mm Deep, Square/Rectangular Concealed type and GI double earthed modular metal boxes of the following types and as specified in RCC/Brick/Concrete Block Masonry with finishing and making good as per the detailed specification. (Refer Sec VI, Clause No.15.12). |
| 140 | ONE/TWO Module |
| 141 | Identification of fault and Replacement of following faulty wiring accessories in labs and low bay areas (Refer Sec VI (MNC), Clause No.4). Note:- Required Electrical component will be issued at free of cost cited above as applicable by the Department. |
| 142 | Replacement, testing and commissioning of electrical components such as 6A to 16A switches and Sockets, telephone jacks, TV coaxial socket, 20A Modular motor starters, 6A to 25A Modular Switch and Socket, Modular plates of different sizes, plug tops in Flush/Concealed type MS switch boxes,2 ft & 4 ft Light Fitting, , etc, as per the detailed specification and as directed by Engineer-in-charge. |
| 143 | Supply, replacement and testing of surface downlight luminaires 12W LED, 230 V, 1200 lumens, Fitting as per detailed specification and as directed by the Engineer-in-charge. |
| 144 | Periodic maintenance of 30 kVA, Three Phase input and output online UPS unit including replacement of failure components as per detailed specification and as directed by the Engineer-in-charge. |
| 145 | Supply, Replacement / Installation, testing and commissioning of 3 Core 6 Sqmm Cu.Cable Flat Type Cable as per the detailed specification and as directed by Engineer-in-charge. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Less (-) 0.0 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Government of IndiaDepartment of Atomic EnergyGeneral Services Organization Centralised Tender Cell TENDER DOCUMENT FOR Providing additional wiring for AC, Geyser points and Electrical Safety check at Residential buildings and Maintenance of Motors in Kalpakkam Township during the year 2026-2027. Tender No: GSO/CTC/ESD/349/2026 Part – II : Financial Bid (Section - VIII) INDEX S.No. Title Page No. |
| 146 | GENERAL INFORMATION FOR GUIDANCE OF TENDERERS |
| 147 | The schedule of quantities is to be read for the purpose of pricing in conjunction with the special conditions, general rules for the guidance of contractors, conditions of contract, specifications, scope of work (Section V), and General Specification (Section VI, VI MNC), drawings, schedule of supply of materials and the appendices for complete interpretation of this scope of work quantity wise. |
| 148 | The prices inserted in the schedule of quantities shall be inclusive of value of the work described including all cost and expenses, which may be required in and for the construction of the work described together with the general risks, liabilities and obligations not forth or implied in the documents on which the tender is to be based. |
| 149 | The quantities stated are to be considered approximate only and the unit prices entered in the schedule of quantities and prices shall apply only to the actual quantities measured in the completed work in accordance with the specifications. |
| 150 | Items of work described in brief are detailed under specification of Work.The scope of work will not be estimated from the brief description of this schedule. |
| 151 | Rate quoted must include all components required for meeting the specification and performance requirements of the item irrespective of whether they are specifically brought out in this schedule or not. |
| 152 | All the materials other than those shown in schedule of supply of materials in section VII are to be arranged by the contractor and his rates should account for the same. |
| 153 | Rates quoted for all items in this tender shall include cost of all materials. Department will not supply any materials other than materials stipulated in Section - VII of the tender and as such the rates quoted must be all inclusive. |
| 154 | If contractors need any clarification they are required to contact the ‘Head, CTC, GSO, Kalpakkam – 603 102, Chengalpattu district, Tamilnadu (Ph – 044 - 27481238 and 044-27480500 Extn. 84299,87345,85803,85532) during office hours. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender