Home Affairs Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56471868

Tender For Construction of Multipurpose Hall At 39Th Bn I.T.B. Police, Greater Noida, Uttar Pradesh.

Issued by Statutory Bodies & Commissions/Committees · Gautam Buddha Nagar, Uttar Pradesh
Tender Value
6.40 Crore
Estimated cost
Bid Submission
05 Aug 2026
15 days left
EMD
12.81 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gautam Buddha Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction of Multipurpose Hall At 39Th Bn I.T.B. Police, Greater Noida, Uttar Pradesh.

BOQ

Name of Work:- C/o Multipurpose Hall at 39th Bn I.T.B. Police, Greater Noida, Uttar Pradesh.
Sl. No. Item Description
1Earth work in excavation by mechanical means(Hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m ; disposed earth to be levelled and neatly dressed. All kinds of soil
2Extra for every additional lift of 1.5 m or part thereof in: excavation/banking excavated or stacked materials.(a) All Kinds of Soil
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
4Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete.
5Supply and stacking of Fly ash conforming to IRC- 58 at site, including carriage, loading , unloading & stacking up to any lead (measured stacks will be reduced by 20% for payment).
6Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using insecticide emulsion/solution @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:
7Treatment of soil under existing floors using insecticide emulsion/solution @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
10Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
11Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).
12Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
13Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
14Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing,finishing carriage for all leads; but excluding the cost of centering, shuttering and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:. Concrete of M30 grade with minimum cement content of 350 kg /cum. : All works up to plinth level
15Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing,finishing carriage for all leads; but excluding the cost of centering, shuttering and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:. Concrete of M30 grade with minimum cement content of 350 kg /cum. : All work above plinth level upto floor V Level
16Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns,raft etc. for mass concrete.
17Centering and shuttering including strutting, propping etc. and removal of form for : Wall
18Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform.
19Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast-in-situ)
20Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers.
21Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts.
22Centering and shuttering including strutting, propping etc. and removal of form for : Chajja
23Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and walls :Under 20 cm wide
24Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars: Upto plinth level.
25Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars : Above plinth level. Thermo-Mechanically Treated bars
26Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
27Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Above plinth level up to floor V level
28Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS : 12894, in super structure Cement mortar 1 : 4 (1 cement : 4 coarse sand) Above plinth level up to floor V level
29Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorptions ≤ 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576.Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
30Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
31Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :White sand stone - Exposed face machine cut and table rubbed with rough backing. 30 mm thick
32Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones instone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.
33Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.Red sand stone
34Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, door window, sills, jambs, soffits, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand) joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing , curing , moulding on all exposed edges and polishing to edge to give high gloss finish etc. complete at all levels(a) Jet Black Granite 18mm thick: Area of slab Upto 0.50 sqm
35Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, door window, sills, jambs, soffits, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand) joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing , curing , moulding on all exposed edges and polishing to edge to give high gloss finish etc. complete at all levels(a) Jet Black Granite 18mm thick: Area of slab over 0.50 sqm
36Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
378.8 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 8.8.1 Wedge expansion type Fastener with threaded dia 12 mm
38Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
399.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
409.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
41Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :125x64x1.90 mm
42Providing & Fixing matt finished stainless steel grade 304 tower bolt ( barrel type) with necessary stainless steel screws etc. complete as per the direction of Engineer-In-Charge. Model STB-01 of SUZU or Equivalent make.250 x 10mm with flap thickness 0.80 mm
439.170 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200 mm
449.165 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm
459.165 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.100mm
46Providing & Fixing matt finished stainless steel grade 304 hanging floor door stopper with necessary stainless steel screws etc. complete as per the direction of Engineer-In-Charge Model SDS-02 of SUZU or Equivalent make. Twin rubber stopper with pin/rod dia 10mm and flap thickness 0.8mm
47Providing and fixing stainless steel grade 304 hook and eyes 150 mm long. with necessary stainless steel screws etc. complete as per the direction of Engineer-In-Charge. Model SSGH of SUZU or Equivalent make.
48Providing & Fixing matt finished stainless steel grade 304 sliding door bolts/L-Drop with necessary stainless steel screws etc. complete as per the direction of Engineer-In-Charge. Model SLD-08 of SUZU or Equivalent make.300x16mm with flap thickness 2.5mm
49Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete
50Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
51Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all comers, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineersin Charge.Wire mesh/Glazing of plain/ toughened/ laminated/ double glass unit with/without high performance coatings as per design requirements and conforming to 15: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for fil Sites with basis wind speed Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for:(i) Sites with basic wind speed> 45m /sec as per IS 875 Part 3 (ii) Sites with structure height more than 20m for all wind speeds make Fenesta/NCL Veka/Saintgobin. 9.147.C2.1 Using R1 series with frame (33 mm & above ) x (35 mm & above) & mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre)
52Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handles. Using R1 series with frame (33 mm & above ) x (35 mm & above) & sash /mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre).
539.147.A1 Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. 9.147.A1.1 Using R2 series with frame (40 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre).
54Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). make Fenesta/NCL Veka/Saintgobin.
55Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
56Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
57Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
58Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.9.135.2 With 12 mm mild steel U beading
59Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete.
60Providing and fixing steel roller for uPVC sliding window with necessary screws etc. complete.
61Providing and fixing steel roller for uPVC sliding door with necessary screws etc. complete.
62Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete.
63Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
64Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
65Providing and fixing bolts including nuts and washers complete.
66Providing and fixing M.S. rivets of sizes in position.
67Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
68Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
69Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes
7021.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sectionsshall be smooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
7121.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
7221.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
73Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin- charge.
7421.12 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar
75Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
7611.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
77Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent.
78Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab of colour Black, Cherry/RubyRed or equivalent
7911.30 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone
80Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement
81Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400 mm of all colours and shades.
82Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer ), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
83Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
84Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
85Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
86Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick
87Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
88Extra for pre finished nosing to treads of steps of Kota stone.
89Extra for Kota stone flooring in treads of steps and risers using single length up to 2.00 metre.
9025 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Second class teak wood
91Providing and fixing of SPORTS FLOORING series with roll dimensions of 1.8 meters width and length of 20 meters and thickness 4.5mm to laid on hard, levelled, smooth and moisture free sub floor. Sports flooring should have traffic classification 33 and weight of 2.8-3.4 kg/m2. Flooring should have caster chair EN-985 tested with color fastness of more than 6. It should be ASTME662 qualified on Smoke density test. Product must be fire rating of the product should be Bfl-S1. Any Joints in flooring rolls should be sealed with cold welding.As per approved shade and colour as per the satisfaction of the .
92Providing and fixing of 10 mm Indoor EPDM flooring with 20% white granuals and PU binders following international standards for GYM - heavy weights area of with roll dimensions of 1 meters width and length of 10 meters size as per company standard should be approved by architect. 10MM thickness to laid on hard, levelled, smooth and moisture free sub floor. Flooring should have quality standards for high resiliance, shock absorption. Any Joints in flooring rolls should be sealed properly. As per approved shade and colour as per the satisfaction of the Architect. Approve Makes :- Boker, Vibrant
9326.1 Providing & fixing in position Phenol bonded Bamboo wood flooring with planks of sizes 14 mm thick, minimum 1800 mm length and minimum 100 mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4 mm thick expanded polyethylene foam sheets having density 40 kg/cum, over prepared surface with necessary quarter round planks of size 1900 mm x 18 mm and door reducer of size 1900 mm x 44 mm, wherever required. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.
9426.2 Providing & fixing in position Phenol bonded Bamboo wood in wall skirting with planks of sizes 14 mm thick, 1900 mm length (minimum) and 85 mm wide(minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC). The skirting shall be fixed with SS screws & rawl plugs, over underlayment of 4 mm thick, expanded polyethylene foam sheets having 40 kg/cum density over prepared surface. The bamboo wood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.
95Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces including cutting to size and shape where required as per specifications, detail drawings and direction ofEngineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses. 26.19.1 0.71 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm.
96Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50 mm with 3 mm thick EPDM seal and SS plain washer complete : Precoated/mill finish aluminium Gutter (600 mm over all girth)
97Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions ≤ 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
9822.23 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative(internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @ 0.70 kg per sqm per coat
9922.23 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative(internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
10022.14 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
101Making khurra 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over P.V.C. sheet 1 m x1m x 400 micron, finished with12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement rounding the edges and making and finishing the outlet complete.
102Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
103Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm Shoe
104Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
105Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
106Wall Paneling Specification upto 8 Feet :-Providing and fixing Wall Paneling with Grooved Slats Acoustical High Density Fiber Board Panels 15 mm with lineal perforations.The panels shall be one side Pre-laminated board (decorative lamination on one side and other sides balancing lamination ) grade -1 with 3 mm grooved at 16/32 mm pitch, Toungue and Groove edges for seamless mounting having density of 700 kg/m3. The back of the panels are perforated with 10mm diameter circular holes with a nonwoven fabric covering of 0.2mm for providing Sound absorption .Panel is to be fixed on Aluminium section (weight approx.150gm/mtr) framework with screw fixed on stud of Knurling G I section of prime quality cold rolled steel as per IS 513 hot dipped galvanized 120 gsm as per BS 2989 and zinc coating as per IS 277 of Knurling GI-48 mm (48 X 34 X 36 X 0.5 X 3050 / 3660 ) wall channel and Knurling GI 50 mm (50X32X32X0.5X3660) floor and ceiling channel are to be fixed with nylon plastic sleeves and wooden screws to from the proper framework . The extra channel must be used at openings and junctions as required. The cavity of framework should be inserted with Rockwool backing/ infill 50 mm with density of 48 Kg/m3 for better insulation. The stud will come at every 600 centre to centre &Aluminium Core Cross channel having thickness 0.50 mm, lenght 2400mm , depth 18 mm and flanges of 7 mm with suitable edge bracket ¢er bracket is then fixed prependicular to stud &floor channel with help of fasteners at every 400 mm centers. The installed system will have NRC not less than 0.84 as per IS: 8225 / ISO: 354 / ASTM 423. Contractor to provide expansion joints of 3 mm ar every 5 mtr bothways. as per manufacturer's specification as per direction of Engineer-in-Charge. ( Make: Earcons Acoustic, Anutone , Knauf)
107Wall Paneling Specifications Above 8 Feet : Providing and Fixing Magnesite Bonded Wood Wool Panel of size 1200x600x25 mm with having density 456 kg/m3 . Which will comprise to NRC Upto 0.95 to 1.00. Panel is to be installed on Knurling GI 48 mm (48 X 34 X 36 X 0.5 X 3050 / 3660 ) framework and meet the stringent fire test required having Class ‘P’ rating for Ignitability test as per BS 476 part 5 and Class ‘1’ rating as per BS 476 part 7 for Surface Spread of Flame test. Class ‘P’ and Class ‘1’ are the highest rating. BS 476 part 6 Fire Propagation index and for Flaming ISO 1182 and Smoke density as per ASTM E 662 besides base panel conform to EN 13168 2000 with complete Strut frame work as per Installation details given. Installation:- The Magnesite Bonded Wood Wool Panel is to be fixed on stud of Knurling G I section of prime quality cold rolled steel as per IS 513 hot dipped galvanized 120 gsm as per BS 2989 and zinc coating as per IS 277 of Knurling GI-48 mm (48 X 34 X 36 X 0.5 X 3050 / 3660) wall channel and Knurling GI 50 mm (50 X32X32X0.5X3660) floor and ceiling channel are to be fixed with nylon plastic sleeves and wooden screws to from the proper framework . The extra channel must be used at openings and junctions as required. The cavity of framework should be inserted with Rockwool backing/ infill 50 mm with density of 48 Kg /m3 for better insulation. The stud will come at every 600 centre to centre & Panel to be fixed perpendicular to the GI-48 mm channels with steel screws. The Appove colour of 3-4 mm fabric pasted on the panel. The panel in line & level. As per the specification and direction of the incharge. (Make: Earcons Acoustic, Anutone , Heradesign)
108Providing and fixing calcium silicate perforated board false ceiling at all heights including providing and fixing of frame work made of special sections power pressed from M.S. sheetand galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling withdash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mmcentre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm eachhaving clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the calcium silicate board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mmlong, the perimeter of ceiling fixed to wall/partition with thehelp of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame ofperimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but but excluding the cost of painting of thickness of calcium ilicate board as below:- 8 mm thick
109Providing and fixing tiled false ceiling of approved materials of size 595X595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams per sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24X38 mm made from 0.30 mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24X25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200X600 mm and secondary cross “T” of length 600 mm and size 24X25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200X600 mm panel to form grids of 600X600 mm and wall angle of size 24X24X0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 X 37 X 25 X 1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 X 30 X 0.8 mmspaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be prepaintedwith polyester paint, all complete for all heights asper specifications, drawings and as directed by Engineer-incharge.GI Metal Ceiling Lay in Plain Tegular edge Global white colour tiles of size 595X595 mm, and 0.5 mm thick with 8 mm drop, made of G I Sheet having galvanizing of 100gms/sqm (boths ides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
11026.27 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80 gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size 24 x 24 X 3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications , drawings and as per directions of the engineer-in-charge.2 With 20 mm thick beveled tegular mineral fibre false ceilingtile (NRC 0.7)
11112 mm cement plaster of mix : 1:6 ( 1 cement : 6 coarse sand )
11215mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement : 6 coarse sand )
1136 mm cement plaster 1:3 ( 1 cement : 3 fine sand)
114Providing and applying Acrylic wall putty of approved brand and manufacturer,in two coats to a average thickness of 1 mm, over the cement plastered wall surface to prepare the surface even and smooth(The rate quoted is inclusive of all operation of removal of dust, dirt and forign metal etc. before applying the putty and preparing the dried surface with fine emery paper fit to receive the paint etc.) complete.
115Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
116Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
117Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kg/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litre/10 sqm, complete as the direction of Engineer -in-Charge.
118Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc Complete
119Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
120Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
121Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
122Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
12317.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
124Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
125Providing and fixing toilet paper holder : C.P. brass
126Providing and fixing towel ring complete with brackets fixed with CP brass screws PVC sleeves etc. Complete. 450 mm long .Model No- ACN-1111 BNM , of Jaquar or equivalent make
127Providing and fixing Health facad with 8mm Dia, 1.00 M long Flexible Tube & Wall hook arrangement Model No- ALD-573 , of Jaquar or equivalent make
128Providing and fixing soil, waste and vent pipes : Hubless centrifugally cast (spun) iron pipe epoxy coated inside & outside IS:15905100 mm dia
129Providing and fixing soil, waste and vent pipes : Hubless centrifugally cast (spun) iron pipe epoxy coated inside & outside IS:1590575mm diameter :
130Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905100 mm dia
131Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:1590575 mm dia
132Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 17.60.1.3 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905100 mm inlet and 100 mm outlet
133Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 17.60.1.3 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905100 mm inlet and 75 mm outlet
134Providing & fixing cockcroch trap S.S. grating of approved design for floor traps etc. including setting in floor with cement mortar. 100 mm dia
135Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40 mm dia Semi rigid pipe
136.Providing and fixing Polyethelene-Aluminium- Polyethelene (PEALPE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. CONCEALED WORK, including cutting chases and making good the wall etc 1216 (16 mm OD) pipe
137.Providing and fixing Polyethelene-Aluminium- Polyethelene (PEALPE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. CONCEALED WORK, including cutting chases and making good the wall etc 1620 (20 mm OD) pipe
138Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer in charge.2025 (25 mm OD) pipe
139Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer in charge.2532 (32 mm OD) pipe
140Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engineer in charge.3240 (40 mm OD) pipe
141Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
142Providing and fixing Braided hose with Two 15mm Nuts & Rubber washers without Nipple : Model No. ALD-805B of Jaquar or equivalent make45 cm length
143Providing and fixing C.P. brass bib cock quarter turn with Wall flange Model no OPL-15037 of Jaquar or equivalent make
144Providing and fixing C.P. Brass kitchen sink mixer with swinging spout on upper side (wall mounted) with connecting legs and flangs as per model no. OPL-15165 of jaquar or equvilent make
14518.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ..1 15 mm nominal bore
14618.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter
147Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge.
148Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.5000 l
149Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore.
150Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
151Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
152Providing and fixing ball valve (brass) of approved quality, High or low pressure with plastic floats complete25 mm nominal bore
153Wiring for light point/ fan point/ call bell point with 2x1.5 sq.mm FRLS /HFFR PVC insulated copper conductor singlecore cable in recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS /HFFR PVC insulated copper conductor single core cable etc. as required Group C
154Wiring for group controlled (loopied) light point/ fan point/exhaust fanpoint/ call bell point with 2x1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required Group C
155Wiring for twin control light point with 1.5 sq.mm FRLS /HFFRPVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
156Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
157Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
158Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
159LED Panel light 2x2 ft. (System lumen efficiancy ≥120 <135 lm/Watt) Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 45 Watt
160LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency > 85 % , Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation ColorMatching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved / Embossing / Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body including trim 12-15 Watt
161LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation ColorMatching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark / Name Engraved / Embossing / Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body including trim 18 Watt
162LED Batten light (System lumen efficacy ≥105 <120lm/watt Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 24- 26 Watt
163Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
164Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
165Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
166Supplying and fixing 30A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\" curve, TP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
167Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
168Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
169Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.c) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
170Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.d) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
171Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.e) 4 X 10 sq. mm + 2 X 6sq. mm earth wire
172Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.f) 4 X 16 sq. mm + 2 X 10 sq. mm earth wire
173Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)a) 4 way (4 + 12), Double door
174Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)b) 8 way (4 + 24), Double door
175Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 100 A,16 KA,TP MCCB
176Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)a) 8 way , Double door
177Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)b) 12 way , Double door
178Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
179Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door
180Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8way (4 + 24), Double door
181Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
182Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
183Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A
184Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as requireda) 25 A
185Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as requiredb) 40 A
186Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as requiredc) 63 A
187Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
188Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
189Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
190Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
191Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
192Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
193Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
194Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
195Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, paintingsuspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
196Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required. a) 1 or 2 Module (75mmX75mm)
197Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm
198Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. a) 2Pair
199Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) Telephone socket outlet (RJ11)
200Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 Run of cable
201Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.a) 100 mm X 100 mm X 60 mm deep
202Supplying and fixing metal box of following sizes (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.a) 180 mm X 100 mm X 60 mm deep
203Supplying and laying 25 mm x 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode,including connection / terminating with G.I. nut bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolts & spring washer spaced at 50 mm)
204Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
205Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
206Earthing with G.I. earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
207Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
208Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
209Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
210Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
211Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub-main wiring/ cable as required.
212Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as require
213Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 120 sq. mm
214Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following sizes of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 120 Sq.mm.
215Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following sizes of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 120 Sq.mm.
216Supplying and making streight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following sizes of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 120 Sq.mm.
217Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.a) Upto 35 sq. mm
218Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.b) Above 35 sq. mm and upto 95 sq. mm
219Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.c) Above 95 sq. mm and upto 185 sq. mm
220Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.d) Above 185 sq. mm and upto 400 sq. mm
221Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.a) Upto 35 sq. mm (clamped with 1mm thick saddle)
222Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
223Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.c) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
224Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.d) Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
225Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.a) 3.5 x 300 sq.mm
226Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.b) 3.5 x 185 sq.mm
227Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.c) 3.5 x 50 sq.mm
228Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.d) 4 x 25 sq.mm
229Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.e) 4 x 16 sq.mm
230Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.f) 4 x 10 sq.mm
231Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
232Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
233Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
234Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
235Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
236Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
237Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
238Supply, installation, testing and commissioning of 3 phase and Neutral 433V 4 wire free standing floor mounted MV Panel made out of 2mm thick CRCA sheet for main frame and 1.6 mm thick for partions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating 1.0 Heat shrinkable sleeves. The metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below and as per Technical specification. The panel shall be got fabricated from manufactures with CPRI Test certificate only. The PCC shall have atleast two spare cubicles to suit the highest rating outgoing MCCB. The size of all Panel Mounting Meters shall be 96X96 mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF push buttons, ON/OFF / Trip indication lamps of LED type and shunt trip coils wherever Electrical Interlocking is specified. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. All ACBs/MCCBs 160A and above shall be with Micro processor releases. All CTs/CBCT shall be resin cast type. All MCCBs below 160A shall be with adjustible Thermal magnetic releases. All ACBs/MCCBs shall be Icu=Ics=100%. All McCBs shall be provided with spreader links and Rotary handles.LT Panel :Transformer Incomer : 400 A FP 35KA MCCB MP RELEASE O/L,S/C, E/F PROTECTION :Metering For Incomers : 0-500V Digital Voltmeter with selector switch and MCBs :400 A Digital Ammeter with CTs of ratio 400/5A, Class 1 Accuracy and 15 VA burden and selector switch :LED Phase indication lamps with individuals MCBs and control with toggle switches :ACB SHUNT TRIP COIL, MCCB SPREADER LINK, MCCB ROTARY HANDEL,DIGITAL AMMETER, AMMETER SELECTOR SWITCH,CT , DIGITAL VOLT METER,VOLTMETER SELECTOR SWITCH, OVER CURRENT & EARTH FAULT RELAY(50,50N,51,51N), PHASE INDICATING LAMP R/Y/B, 6A SP MCB,6A DP MCB etc. all necessory accessories complete suitable as required. Busbars : 500A TPN Aluminium Busbar - 1 Set :Outgoings : MCCB 200 Amp TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 02 NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK : MCCB 100 Amp TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 06 NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK : MCCB 63A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 08 NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK :MCCB 100 Amp TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 06 NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK :MCCB 63A TP+NL 36KA TM RELEASE WITH O/L,S/C PROTECTION- 08 NOS, MCCB ROTARY HANDEL,MCCB SPREADER LINK :32A-16A, TPN MCB - 6NOS
239Supply, erection,testing and commissioning of 5m octagonal Pole with single arm. Material for pole section: Hot rolled product of non alloy structural steel grade S355, Other parts: MS as per IS 2062. Material as per BS EN 10025 equivalant to Indian standard.. Bottom (O.A.F.) 130mm and top (O.A.F.) 70mm. Size of Base Plate: 200 SQ, thickness of base plate should be minimum 12mm, hole PCD 200, hole dia 20mm. Tolerance on material thickness as per IS:1852/85. Pole shall be hot dip galvanized as per IS: 2629. Make: Signify 5mtr. octagonal pole with single arm of 1000mm length and 48.3mm dia. Similar to above specs in Signify /Philips or equivalent
240Supply testing of under noted sizes of Alum.conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.a) 4 x 6 sq.mm
241Supply testing of under noted sizes of Alum.conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required.b) 3 x 6 sq.mm
242Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming toIS-12615: 2018. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.For pump defined above & of duty as follows for Sprinkler and Hydrant system :1620 lpm at 56 m Head
243Supply, installation, testing and commissioning of Jockey pump (pressurisation pump) comprising of the following:
244Providing, fixing, testing and commissioning of precharged air vessel (size 250 mm dia & 1200 mm height, 8mm thick MS sheet) for pressurization of hydrant / sprinkler system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm dia Gun Metal Wheel valve with required accessories, air release valve with stop cock on the top, pressure gauge and painting with synthetic enamel paint of approved shade as required. minimum 50 mm dia inlet with isolating valve duly painted from inside and outside with two coats of synthetic enamel paint over a coat of primer complete as required. (Vessel should be suitable for rated working pressure).
245Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal / Stainless Steel cap and chain as required : Single headed Gunmetal
246d) Connections from riser with 40 mm dia stop valve (gun metal ) and M.S. pipe
247Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
248Supplying and fixing 63mm dia, 15 mtr long RRL hose pipe with 63mm dia male and female gun metal couplings duly binded with GI wire, rivets etc. confirming to IS 636 (type-A)as required. (Gun Metal)
249Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required (Gun metal)
250Supply & Fixing of Fire Man's Axe with heavy Insulated rubber tested up to 20 KV and confirming to IS ;926 as required.
251Providing & fixing 100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg) range, 3 / 8\\" BSP bottom entry on Pump Delivery Line complete with Ball valve
252Providing and fixing M.S. fire hose door (Including door frame and all civil work and finishing) of size 2000mm High x 1600mm Wide x 100 mm Deep approx.Fabricated from 16 gauge M.S sheet.Provision for hole fasteners on both sides with double dore & frame with 2 nos locking arrangement with 2 nos tower bolts and Glazed with 4mm thick Float clear glass (glass panel to be fix in door panel - 700 mm from the bottom of the door and 100 mm from the top /sides of door panel) suitably marked on the outside with the letters \\"FIRE HOSE\\".all M.S. work to be stove in Enamled Fire Red Colour over appropriate primer (Front side P.O. Red Paint & inside white paint two coat).The width & height to depend upon the actual size of the fire shaft available.Contractor to make shop drawings and get it approved by Enginner -in-charge/Consultant before fabrication.(Cost shall be inclusive of providing break glass box containing key for the door)
253Providing laying, testing and commissioning of class 'C' heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.100 mm dia
254Providing laying, testing and commissioning of class 'C' heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.80mm dia
255Providing laying, testing and commissioning of class 'C' heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge.25 mm dia
256Providing and fixing inspection & testing assembly/drain assembly consist of following :- i) 25 mm dia Inspection Test Valve (Ball Valve) & Piping ii) Sight Glass iii) Union iv) 50 mm dia ball valve for drain with piping The arrangment shall be complete as per drawing and as per NBC provisions. The item will include all works from the sprikler header to the drain pipe.
257Supplying and fixing air release valve made of 100 mm dia, required accessories, as required
258Providing and fixing of carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to ID:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 4.5 Kg.
259Providing and fixing of ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to ID:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 4.0 Kg.
260Supplying, installation, testing & commissioning Sector panel sultable for following zones, complete with visual Indications for short circuit Fault condition and all other standard facilities as per IS: 2189 with mimic diagram for all area/ zone covered, complete with all connections, interconnections as required. 4 zone
261Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
262Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required
263Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required
264Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
265Supply, installation testing and commissioning of 2W Double sided LED signage with built in battery back-up for minimum of 3hrs continuous operation in an active mode. luminaire shall be fitted with a bi-colour Red/Green LED to indicate its status. complete with all accessories as per required.
266Supply, installation testing and commissioning of 2W Double sided LED signage with built in battery back-up for minimum of 3hrs continuous operation in an active mode. luminaire shall be fitted with a bi-colour Red/Green LED to indicate its status. complete with all accessories as per required.
267Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25mm dia
268Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow / Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor (s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5Outdoor units:-150 (50 HP) 03 Nos Working (Setting, Stage & back corridor) Standby outdoor is not included in BOQ(150 HP) Outdoor unit Total Capacity
269Supply, installation, testing & commissioning of double skin air handling units with thermal break profile with 25 mm thick PUF insulation consisting of fan section with fan, motor, motor mounting arrangement belt drive system and vibration isolators, cooling coil sections with coils & mixing box with aluminium volume control dampers on fresh air & the outlet of AHU, filter section with filters, double canvas connections as required etc complete as per specifications and drawings. Competable with VRV system & outdoor.
270Supply, installation, testing and commissioning of Split type air-conditioning unit, each comprising of an one number outdoor unit and one number indoor unit. Outdoor condensing unit shall comprise of compressor & air cooled condenser with fan. Evaporating unit shall consist of a blower section with dynamically balanced centrifugal blower driven by TEFC squirrel cage induction motor, multirows deep copper cooling coil with aluminium fins, thermostatic expansion valve etc. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit. The units shall be suitable for 230V±6%, or 415V±10%, 50 Hz. supply & complete with electrical controls & panels.1.0 TR
271Supply, installation, testing and commissioning of Split type air-conditioning unit, each comprising of an one number outdoor unit and one number indoor unit. Outdoor condensing unit shall comprise of compressor & air cooled condenser with fan. Evaporating unit shall consist of a blower section with dynamically balanced centrifugal blower driven by TEFC squirrel cage induction motor, multirows deep copper cooling coil with aluminium fins, thermostatic expansion valve etc. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit. The units shall be suitable for 230V±6%, or 415V±10%, 50 Hz. supply & complete with electrical controls & panels.1.5 TR
272Supply, installation, testing and commissioning of Split type air-conditioning unit, each comprising of an one number outdoor unit and one number indoor unit. Outdoor condensing unit shall comprise of compressor & air cooled condenser with fan. Evaporating unit shall consist of a blower section with dynamically balanced centrifugal blower driven by TEFC squirrel cage induction motor, multirows deep copper cooling coil with aluminium fins, thermostatic expansion valve etc. The evaporating unit shall be equipped with synthetic fibre filters, insulated drain pan, safety controls, thermostat all complete in a unit. The units shall be suitable for 230V±6%, or 415V±10%, 50 Hz. supply & complete with electrical controls & panels.2.0 TR
273Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class- O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 31.8 mm dia (OD) (hard drawn) with tube thickness 1.62 mm with 19
274Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class- O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :34.9 mm dia (OD) (hard drawn) with tube thickness 1.62 mm with 19
275Refrigerant R-410A to top up the system if required.
276Supply,installation, testing and commissionig of refrigerant Copper Y-Joints and T-Joints.
277Providing and fixing in position the following CPVC Drain with all necessary 32 mm dia drain pipe.
278Providing and fixing in position the following CPVC Drain with all necessary 25 mm dia drain pipes.
279Supply,Installation, Testing and Commissioning of Master Remote Control Suitable for 15nos of indoor unit.
280Supplying, installing, testing and commissioning of direct driven 300 dia free flow propeller fan with gravity louvers.
281Supply, installation, testing and commissioning of Inline Fan exhaust fan with centrifugal blower and motor encased in sheet metal casing, as per specifications. The motor shall be suitable for 220 ± 6% V, 50 Hz AC supply. The price shall include fan speed regulator and cowl with bird screen and electrical wiring from socket to fan cons:750 cfm inline fan at 15mm static presssure.
282Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm Sheet (24 Guage)
283Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.80 mm Sheet (22 Guage)
284Supply and installation of flexible ducting made of steel helix wire with insulation of fibreglass 25 mm thick and of density 24 kg/ cum covered with AL foil from both sides. Item shall be complete with duct joining clamps, duct sealing tapes , supports etc. Flexible ducts to be hungstretched and not to be left sagging.100 mm ⦰ Flexible Duct (For Cassette Units)
285Supply, installation, testing and commissioning of double canvas for outlet connection of the equipments.
286Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
287Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
288Supplying & fixing of powder coated extruded aluminium Return Air Grills without aluminium volume control dampers as per specifications.
289Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with antismudge ring & removable core.
290Supplying, fixing testing commissioning of Return/Exhaust air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core.
291Supplying, fixing testing commissioning of powder coated aluminium Fresh/Exhaust air louvers With Damper and Bird screen.
292Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
293Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.19 mm Thick
294Design, manufacture, supply, installation, testing and commissioning of the following integrated, cubicle type, dead front, extensible, sheet steel control panels, anchoring the panel to the foundation. The panel shall be suitable for 500 volts, 50 cycles, 4 wire supply. (Incommer power supply to AC panel by others).HVAC contractor has to terminate incoming cable to AC panel along with the incoming switch. Quoted price shall include all necessary internal wiring, earthing. Separate compartments for bus bar and cable alleys. The panel shall have minimum 2 spare compartments. The following components and accessories shall be mounted within the control panel. Contractor has to take approval from consultant/ site engineer incharge the SLD drawings for electrical panel before fabricationHVAC PANEL-1INCOMINGOne No. 250 amps, 25 ka, 4-pole MCCB complete with adustable overload circuit protection.0-500 Volts 96 x 96 mm square voltmeter digital type with selector switch1 Set0-50 amps ammeter digital type with 300/5 amps CT's and selector switch 1 SetPhase indicating lamps with control SP MCB.Aluminum bus bar sleeve type rated at 300 amps for three phase & neutral phase bus bar shall have maximum current density of 1.0 amp per sq. mm and the neutral bus bar of not less than 50 % capacityOUTGOING :2 Nos 63 amps, 25 k, TPN MCCB with single phase /overload circuitprotection.2 Nos 100 amps, 25 k, TPN MCCB with single phase /overload circuitprotection.
2952.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil
2961:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
297Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
298Supplying and stacking at site.Good Earth
299Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
300Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in Charge.16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
301Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in-charge
302Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess / less cement used as per design mix is payable / recoverable separately
30316.45 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
30416.46 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.
305Providing and applying 2.5 mm thick road marking strips (retroreflective)of specified shade/ colour using hot thermoplastic materialby fully/ semi automatic thermoplastic paint applicator machine fittedwith profile shoe, glass beads dispenser, propane tank heater andprofile shoe heater, driven by experienced operator on road surfaceincluding cost of material, labour, T&P, cleaning the road surface ofall dirt, seals, oil, grease and foreign material etc. complete as perdirection of Engineer-in-charge and accordance with applicablespecifications.
306Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
307Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge.
308Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
309Providing and fixing Glow studs of size 100x20 mm made of heavyduty body shall be moulded ASA (Acrylic styrene Acryloretrite ) orHIP (High impact polystyrene) or ABS having electronically weldedmicro- prismatic lens with abrasion resistant coating as approved byEngineer in charge. The glow stud shall support a load of 13635 kg Tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels onboth sides with at least 12 cm of reflective area up each side. Theluminance intensity should be as per the specification and shall betested as described in ASTM I: 809 as recommended in BS: 873part 4 : 1973. The studs shall be fixed to the Road surface using theadhesive conforming to IS, as per procedure recommended by themanufacturer complete and as per direction of Engineer-in-charge
310Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm
3112.1 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water(excluding cost of imported earth, sludge or manure).
312Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
313Supplying and stacking of sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment)
314Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm
315Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 16 mm
316Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 4.75 mm
317Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
318Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
319Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge
320Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads andlifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 1.2 m dia and 1.2 m deep
321Edging with bricks laid dry length wise, including required excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within a lead of 50m : Common burnt clay F.P.S. (non modular) bricks of class designation 7.5
322Providing and stacking of Azadirachta indica ( Neem ) height 120-130cm in polybag size 25 cm as per direction of the officer-in-charge.
323Providing and stacking of Ficus religiosa (Peepal) height 150-165 cm. in poly bag size 30 cm as per direction of the officer-in-charge.
324Providing and stacking of Dalbergia sissoo (Seasam) height 120-135cm. in poly bag size 25 cm as per direction of the officer-in-charge.
325Providing and stacking of Adansonia digitata (kalp vricksh) ht 150-165 cm in bag size 25 cm as per direction of the officer-in-charge.
326Providing and stacking of Polyalthia pendula (Ashok Pendula) height 180-195 cm. in gunny bag size 30 cm as per direction of the officer-incharge.
327Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 90-105 cm.,bushy in big size HDPE bag as per direction of the officer-in-charge.
328Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)Shrubs Plant
329Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)Hedge Plant /Ground cover
330Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.80 mm dia nominal bore
331Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.32 mm dia nominal bore
332Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore
333Providing and fixing square-mouth S.W. gully trap grade 'A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks
334Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
335Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1;2 (1 cement : 2 fine sand) including testing of joints, connecting rcc pipes with manhole, chamber etc. All complete:150 mm dia. R.C.C. pipe
336Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1;2 (1 cement : 2 fine sand) including testing of joints, connecting rcc pipes with manhole, chamber etc. All complete:250 mm dia. R.C.C. pipe
337Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete450 mm dia RCC pipes
338Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round SW/ RCC pipes including bed concrete as per standard design:150 mm diameter SW/RCC pipe
339Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round SW/ RCC pipes including bed concrete as per standard design:250 mm diameter SW/RCC pipe
340Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56471868
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 6.40 Crore
LAST DATE 05-08-2026
Authority
Authority Name Indo Tibetan Border Police Force
Work Description Tender for Construction of Multipurpose Hall At 39Th Bn I.T.B. Police, Greater Noida, Uttar Pradesh.
Basic Detail
Tender No 348-50
Bidding Type Tender
Location
City Gautam Buddha Nagar
State Uttar Pradesh
Key Dates
Publish Date 15 Jul 2026
Submission Date 05 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 6.40 Crore
Tender Fee Ref. Documents
EMD 12.81 Lakhs
Exemption Not Available
Document List
5321bea1-e37f-49ba-a9ff-edc7b4824086.html
BOQ_964103.xls
drawings.pdf
tenderformmphall.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

5321bea1-e37f-49ba-a9ff-edc7b4824086.html

xls

BOQ_964103.xls

pdf

drawings.pdf

pdf

tenderformmphall.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders