Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56469621

Tender For 1) repair maintenance Specialized Electrical And Mechanical Services At Trade & Taxes Building, Ip Estate, New Delhi. 2) repair maintenance Electrical And Mechanical Services At Mso Building, I.P.Estate, New Delhi. (Sh: Replacement Of Outl

Issued by Government Departments · Delhi, Delhi
Tender Value
65.18 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
6 days left
EMD
1.30 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for 1) repair maintenance Specialized Electrical And Mechanical Services At Trade & Taxes Building, Ip Estate, New Delhi. 2) repair maintenance Electrical And Mechanical Services At Mso Building, I.P.Estate, New Delhi. (Sh: Replacement Of Outlived Existing Emergency Panels).

BOQ

Name of Work:- 1) RMO Specialized Electrical and Mechanical services at Trade & Taxes Building, IP Estate, New Delhi. 2) RMO Electrical and Mechanical services at MSO Building, I.P.Estate, New Delhi. (SH: Replacement of outlived existing Emergency Panels).
Sl. No. Item Description
1SH: I (Emergency PANEL 4,5 & 6)Supplying, installation, testing & commissioning of cubical modular type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design having bus bar chamber duly fabricated from CRCA sheet steel of 2 mm thick for frame, back, sides, partition & doors and 3mm thick for glad plate duly powder coated in approved shade including cleaning & finishing complete with 7 tank process complete with 1600 Amp capacity extensible type four strip aluminium alloy bus bars of high conductivity, DMC/ SMC bus bar supports having short circuit withstand capacity of 31 MVA for '1' Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars, control wiring with 2.5 sq. mm. PVC insulated copper conductor single core cable, cooling / ventilation fans including construction of suitable CC foundation, in & out connections and providing & Fixing following switch gears therein etc. complete as required. a) Incoming (i) 3 Nos- 1250 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display & pre overload and over temperature protection indication along with USB Port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date(ii) 3 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, \\"C\\" Curve backup MCB(iii) 3 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 1250/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, \\"C\\" Curve back up MCB.
2b) Bus Coupler (i) 2 Nos - 1250 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V with LSIG release, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc.(ii) 2 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, \\"C\\" Curve backup MCBc) Interlocking (i) Electrical interlocking through advance contacts in ACB's (all Incomers & Bus couplers) along with mechanical interlockingd) Outgoing (i) 2 Nos.- 1000 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display & pre overload and over temperature protection indication along with USB port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date(ii) 2 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, \\"C\\" Curve backup MCB(iii) 2 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 1000/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, \\"C\\" Curve back up MCB.(ii) 5 Set- 630A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(iii)5 Set- 400A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (iv) 8 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (vi) 18 sets- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs along with ON/OFF indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB
3SH: II (EMERGENCY PANEL 1 & 7)Supplying, installation, testing & commissioning of cubical modular type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design having bus bar chamber duly fabricated from CRCA sheet steel of 2 mm thick for frame, back, sides, partition & doors and 3mm thick for glad plate duly powder coated in approved shade including cleaning & finishing complete with 7 tank process complete with 1600 Amp capacity extensible type four strip aluminium alloy bus bars of high conductivity, DMC/ SMC bus bar supports having short circuit withstand capacity of 31 MVA for '1' Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars, control wiring with 2.5 sq. mm. PVC insulated copper conductor single core cable, cooling / ventilation fans including construction of suitable CC foundation, in & out connections and providing & Fixing following switch gears therein etc. complete as required. a) Incoming (i) 2 Nos- 1250 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display & pre overload and over temperature protection indication along with USB Port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date(ii) 2 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, \\"C\\" Curve backup MCB(iii) 2 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 1250/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, \\"C\\" Curve back up MCB.
4b) Bus Coupler (i) 1 Nos - 1250 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V with LSIG release, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc.(ii) 1 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, \\"C\\" Curve backup MCBc) Interlocking (i) Electrical interlocking through advance contacts in ACB's (all Incomers & Bus couplers) along with mechanical interlockingd) Outgoing (i) 2 Nos.- 800 Ampers four pole horizontal drawout type electrically operated air circuit breaker of fault breaking capacity 50 kA breaking capacity (Ics = Icu = Icw=100%) for 1 second suitable upto 690V, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, auxilary contacts, shunt trip, interlocking features etc. complete with self powered Microprocessor based release for adjustable setting for over current, earth fault & short circuit protection with LCD display & pre overload and over temperature protection indication along with USB port for communication & all other standard features conforming to IS 1397-2 : 1993 as amended up-to-date(ii) 2 Sets- RYB Phase indication LED lamps with 6A, 10KA, \\"C\\" Curve back up MCB, breaker ON/OFF/TRIP indicating light with 6A, 10KA, \\"C\\" Curve backup MCB(iii) 2 Nos.- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs of 800/5 A class 1.0 accuracy and 15 VA burden and with 3 Nos 6A, 10KA, \\"C\\" Curve back up MCB.(ii) 8 Set- 630A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(iii)8 Set- 400A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (iv) 6 Set- 250A, FP, 36KA MCCB (Ics=Icu =100%) with Microprocessor based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal.(v) 3 Set- 200A, FP, 36KA MCCB (Ics=Icu =100%) with Thermal based release with adjustable setting having O/L & S/C protection with Rotary handle and spreader terminal. (vi) 25 sets- 3 phase Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. with 3 Nos. resin cast CTs along with ON/OFF indicating light with 6A, 10KA, \\"C\\" Curve backup MCB, auxiliary contacts with MCCB
5SH: III (EI Work)1 ) Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
62) Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm
73 ) Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
84) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
95) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
106 ) Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminum conductor armoured cable of 1.1 KV grade on surface etc complete as required.a) 3 X 10 Sq.mm
11b) 4 X 25 Sq.mm
12c) 3½ X 35 Sq.mm
13d) 3½ X 70 Sq.mm
14e) 3½ X 120 Sq.mm
15f) 3½X 300 Sq.mm
16g) 3½ X 400 Sq.mm
177) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3 X 10 sq. mm (22mm)
18b) 4 X 25 sq. mm (28mm)
19c) 3½ X 35 sq. mm (32mm)
20d) 3½ X 70 sq. mm (38mm)
21e) 3½ X 95 sq. mm (45mm)
22f) 3½ X 120 sq. mm (45mm)
23g) 3½ X 300 sq. mm (70mm)
24h) 3½ X 400 sq. mm (82mm)
258) Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
26b) 3½ X 300 sq. Mm
27c) 3½ X 400 sq. Mm
289 ) Aluminium lugs for 10 sq. mm cable
2910 ) Aluminium lugs for 16 sq. mm cable
3011) Aluminium lugs for 25 sq. mm cable
3112) Aluminium lugs for 35 sq. mm cable
3213 ) Aluminium lugs for 70 sq. mm cable
3314) Aluminium lugs for 120 sq. mm cable
3415 ) Aluminium lugs for 300 sq. mm cable
3516 ) Aluminum lugs for 400 sq. mm cable
3617 ) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.17.01) 63 mm dia (OD-63 mm & ID-51 mm nominal)
3717.02) 120 mm dia (OD-120 mm & ID-103 mm nominal)
3818 ) Dismantling and shifting of the existing emergency panel complete with bus bar, accessories including dismantling of cables, cutting of base/supporting frame etc. with the help of heavy labour, chain pulley, welding machine to make frame of channels along with shifting from Sub-Station to other location as per directions of Engineer-in-charge complete as required.
3919) Credit of old dismantle materials:-19.01) Emergency panel
4019.02) Assorted Cable
4119.03) Assorted Lugs/Malba etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56469621
AUTHORITY Government Departments
TENDER VALUE 65.18 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for 1) repair maintenance Specialized Electrical And Mechanical Services At Trade & Taxes Building, Ip Estate, New Delhi. 2) repair maintenance Electrical And Mechanical Services At Mso Building, I.P.Estate, New Delhi. (Sh: Replacement Of Outlived Existing Emergency Panels).
Basic Detail
Tender No 79/EE(E)/PWDDHC,ND/C/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 15 Jul 2026
Submission Date 21 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value 65.18 Lakhs
Tender Fee Ref. Documents
EMD 1.30 Lakhs
Exemption Not Available
Document List
6a31f1bd-c8c0-4fd3-b63c-a71175166d81.html
BOQ_393001.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

6a31f1bd-c8c0-4fd3-b63c-a71175166d81.html

xls

BOQ_393001.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender