Tender For Upgradation Of Chc Mathalput Of Koraput District
Tender Value
4.06 Crore
Estimated cost
Bid Submission
12 Aug 2026
8 days left
EMD
4.06 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Koraput → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Upgradation Of Chc Mathalput Of Koraput District
BOQ
| Sl. No. | Item Description |
| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Civil Work- Earth work excavation in all kinds of soil within initial lead of 50 m. And initial lift of 1.5 m. including rough dressing and leveling the bed.RENOVATION |
| 3 | CASUALTY |
| 4 | OPD TICKET COUNTER |
| 5 | PUBLIC TOILET |
| 6 | MAIN GATE |
| 7 | BOUNDARY WALL |
| 8 | RCC DRAIN |
| 9 | PAVER ROAD, PARKING & LANDSCAPING |
| 10 | Supplying & filling foundation and plinth with course sand well watered and rammed including cost, cost of all labour, carriage, royalty, etc complete.RENOVATION |
| 11 | CASUALTY |
| 12 | OPD TICKET COUNTER |
| 13 | PUBLIC TOILET |
| 14 | MAIN GATE |
| 15 | BOUNDARY WALL |
| 16 | RCC DRAIN |
| 17 | PAVER ROAD, PARKING & LANDSCAPING |
| 18 | Cement concrete of proportion (1:2:4) in F&F using 12mm size cb/hb chips of approved quality including cost, conveyance, taxes & royalty of all materials and labour with T&P etc. complete in all respect.PAVER ROAD, PARKING & LANDSCAPING |
| 19 | Providing, lifting, hoisting and laying cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. Kerb StonePAVER ROAD, PARKING & LANDSCAPING |
| 20 | Providing and laying of 80mm thick factory made cement concrete interlocking paver block of M-35 grade and approved make, varity, colour and size made by Block making machine with strong vibratory compacrion of approved design and shape laid in required colour and pattern over 50mm thick compacted bed of coarse sand, filling the joints with find sand etc, all complete include cost, conveyance, royalty, taxes of all materials, labour T&P etc, complete as per direction of Engineer-in-Charge. Paver BlockPAVER ROAD, PARKING & LANDSCAPING |
| 21 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).ncluding cost of labour, T&P, all taxes and royalties etc. complete as directed by engineer-in-chargePAVER ROAD, PARKING & LANDSCAPING |
| 22 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. CPWD DSR CH-1 NEW 2.33 LANDSCAPEPAVER ROAD, PARKING & LANDSCAPING |
| 23 | C.C (1:4:8) with 4cm size HG CRUSHER BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.CRENOVATION |
| 24 | CASUALTY |
| 25 | OPD TICKET COUNTER |
| 26 | PUBLIC TOILET |
| 27 | MAIN GATE |
| 28 | BOUNDARY WALL |
| 29 | RCC DRAIN |
| 30 | Cement Concrete (1:3:6) with 4cm size hard granite metal in Foundation and Plinth.RENOVATION |
| 31 | R.C.C work of M-20 grade with 20mm & down grade BHG C/B chips including hoisting, laying & all cost, conveyance, royalty & taxes etc. comp. to work site as per the specification approved by the deptt. & direction of EIC.Foundation & PedestalRENOVATION |
| 32 | CASUALTY |
| 33 | OPD TICKET COUNTER |
| 34 | PUBLIC TOILET |
| 35 | MAIN GATE |
| 36 | BOUNDARY WALL |
| 37 | Column,(footing to plinth level )RENOVATION |
| 38 | CASUALTY |
| 39 | OPD TICKET COUNTER |
| 40 | PUBLIC TOILET |
| 41 | MAIN GATE |
| 42 | BOUNDARY WALL |
| 43 | Plinth BeamRENOVATION |
| 44 | CASUALTY |
| 45 | OPD TICKET COUNTER |
| 46 | PUBLIC TOILET |
| 47 | MAIN GATE |
| 48 | BOUNDARY WALL |
| 49 | RCC DRAIN |
| 50 | ColumnGround FloorRENOVATION |
| 51 | CASUALTY |
| 52 | OPD TICKET COUNTER |
| 53 | PUBLIC TOILET |
| 54 | MAIN GATE |
| 55 | BOUNDARY WALL |
| 56 | Column First FloorCASUALTY |
| 57 | MAIN GATE |
| 58 | Roof Beam Ground FloorRENOVATION |
| 59 | CASUALTY |
| 60 | OPD TICKET COUNTER |
| 61 | PUBLIC TOILET |
| 62 | MAIN GATE |
| 63 | Roof Beam First FloorCASUALTY |
| 64 | MAIN GATE |
| 65 | Slab Ground FloorRENOVATION |
| 66 | CASUALTY |
| 67 | OPD TICKET COUNTER |
| 68 | PUBLIC TOILET |
| 69 | MAIN GATE |
| 70 | Slab First FloorCASUALTY |
| 71 | MAIN GATE |
| 72 | Staircase Ground FloorCASUALTY |
| 73 | Chajja Ground FloorRENOVATION |
| 74 | CASUALTY |
| 75 | OPD TICKET COUNTER |
| 76 | PUBLIC TOILET |
| 77 | MAIN GATE |
| 78 | Chajja First FloorCASUALTY |
| 79 | MAIN GATE |
| 80 | LintleGround FloorRENOVATION |
| 81 | CASUALTY |
| 82 | OPD TICKET COUNTER |
| 83 | PUBLIC TOILET |
| 84 | MAIN GATE |
| 85 | LintelFirst FloorCASUALTY |
| 86 | MAIN GATE |
| 87 | Supplying fitting & placing uncoated HYSD reinforcement including cutting, bendind,binding & placing the steel rods as per drawing & technical specification with cost of binding wire 18 to 20 gauge Ground Floor RENOVATION |
| 88 | CASUALTY |
| 89 | OPD TICKET COUNTER |
| 90 | PUBLIC TOILET |
| 91 | MAIN GATE |
| 92 | BOUNDARY WALL |
| 93 | DRAIN |
| 94 | First FloorCASUALTY |
| 95 | MAIN GATE |
| 96 | Brick work with Fly ash Bricks 23cm x 11cm x 8cm size having crushing strength not less than 75Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in Foundation and Plinth & Super structure including watering curing, cost of carriage and royalty of all materials, cost of all labour, etc complete. F&PRENOVATION |
| 97 | CASUALTY |
| 98 | OPD TICKET COUNTER |
| 99 | PUBLIC TOILET |
| 100 | MAIN GATE |
| 101 | BOUNDARY WALL |
| 102 | Brick work with Fly ash Bricks 23cm x 11cm x 8cm size having crushing strength not less than 75Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in Foundation and Plinth & Super structure including watering curing, cost of carriage and royalty of all materials, cost of all labour, etc complete. Ground Floor RENOVATION |
| 103 | CASUALTY |
| 104 | OPD TICKET COUNTER |
| 105 | PUBLIC TOILET |
| 106 | MAIN GATE |
| 107 | BOUNDARY WALL |
| 108 | First Floor CASUALTY |
| 109 | MAIN GATE |
| 110 | 12mm thick C.P.(1:6) on brick masonary to the smooth surface including watering, curing, cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C.Ground Floor RENOVATION |
| 111 | CASUALTY |
| 112 | OPD TICKET COUNTER |
| 113 | PUBLIC TOILET |
| 114 | MAIN GATE |
| 115 | First FloorRENOVATION |
| 116 | CASUALTY |
| 117 | 16mm thick C.P. (1:6) over brick masonary to the smooth surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. Ground Floor RENOVATION |
| 118 | CASUALTY |
| 119 | OPD TICKET COUNTER |
| 120 | PUBLIC TOILET |
| 121 | MAIN GATE |
| 122 | BOUNDARY WALL |
| 123 | First FloorRENOVATION |
| 124 | CASUALTY First Floor |
| 125 | MAIN GATE |
| 126 | 6 mm thick C.P. (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment , watering, curing cost, carriage & royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. Ground Floor RENOVATION |
| 127 | CASUALTY |
| 128 | OPD TICKET COUNTER |
| 129 | PUBLIC TOILET |
| 130 | MAIN GATE |
| 131 | First FloorRENOVATION |
| 132 | CASUALTY First Floor |
| 133 | MAIN GATE |
| 134 | Supplying, fitting and fixing vetrifed tile in floors of size 600mm x 1200mm of approved make conforming to IS:13755 laid on 20mm thick cement mortar (1:4) and filling joints with white cement of approved quality etc. complete including cost, conveyance, taxes, cess royaltieis of all materials with labour (T&P) etc., complete and as per direction of Engineer-in-charge. Fixing of (600mm x1200mm) size Vetrified tiles Colour/ printed series of Johnson/Kajaria/Somany branded make in floors, Trades of steps & LandingGround Floor RENOVATION |
| 135 | CASUALTY |
| 136 | First FloorRENOVATION |
| 137 | Supplying, fitting and fixing vetrifed tile in floors of size 600mm x 600mm of approved make conforming to IS:13755 laid on 20mm thick cement mortar (1:4) and filling joints with white cement of approved quality etc. complete including cost, conveyance, taxes, cess royaltieis of all materials with labour (T&P) etc., complete and as per direction of Engineer-in-charge.Ground Floor DDC |
| 138 | OPD TICKET COUNTER |
| 139 | MAIN GATE |
| 140 | First FloorCASUALTY |
| 141 | S/F/F of ceramic floor tiles of premium grade having thickness 7mm to 8mm ( 30cm x 30cm / 40cm x 40cm special plain / printed series )Ground Floor RENOVATION |
| 142 | CASUALTY |
| 143 | PUBLIC TOILET |
| 144 | MAIN GATE |
| 145 | First FloorCASUALTY |
| 146 | S/F/F of granite up to size 0.10 sqm to 0.4sqm i.e up to 2'1\\" x 2'1\\" (10mm thick) in floorsGround Floor RENOVATION |
| 147 | CASUALTY |
| 148 | OPD TICKET COUNTER |
| 149 | PUBLIC TOILET |
| 150 | MAIN GATE |
| 151 | First FloorCASUALTY |
| 152 | Fixing tiles in dados on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete.S/F/F of ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm ( 30cm x 30cm / 40cm x 40cm special plain / printed series )Ground Floor RENOVATION |
| 153 | CASUALTY |
| 154 | PUBLIC TOILET |
| 155 | MAIN GATE |
| 156 | First FloorCASUALTY |
| 157 | Vitrified dadoGround Floor RENOVATION |
| 158 | CASUALTY |
| 159 | OPD TICKET COUNTER |
| 160 | First FloorCASUALTY |
| 161 | Finishing wall surface of walls with Acrylic wall putty (water based) of approved make & finished smooth & even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc. complete. Ground Floor RENOVATION |
| 162 | CASUALTY |
| 163 | OPD TICKET COUNTER |
| 164 | PUBLIC TOILET |
| 165 | MAIN GATE |
| 166 | BOUNDARY WALL |
| 167 | First FloorRENOVATION |
| 168 | CASUALTY First Floor |
| 169 | MAIN GATE |
| 170 | Priming one coat with any approved primer including cost of primer for Wall workGround Floor RENOVATION |
| 171 | CASUALTY |
| 172 | OPD TICKET COUNTER |
| 173 | PUBLIC TOILET |
| 174 | MAIN GATE |
| 175 | BOUNDARY WALL |
| 176 | First FloorRENOVATION |
| 177 | CASUALTY |
| 178 | MAIN GATE |
| 179 | Wall painting two coats with plastic emulsion paint of approved shade including cost of paint.Ground Floor RENOVATION |
| 180 | CASUALTY |
| 181 | OPD TICKET COUNTER |
| 182 | PUBLIC TOILET |
| 183 | MAIN GATE |
| 184 | First FloorRENOVATION |
| 185 | CASUALTY First Floor |
| 186 | MAIN GATE |
| 187 | Wall painting two coats with weather coat of approved shade including cost of paint.Ground Floor RENOVATION |
| 188 | CASUALTY |
| 189 | OPD TICKET COUNTER |
| 190 | PUBLIC TOILET |
| 191 | MAIN GATE |
| 192 | BOUNDARY WALL |
| 193 | DRAIN |
| 194 | First FloorRENOVATION |
| 195 | CASUALTY |
| 196 | MAIN GATE |
| 197 | Providing and fixing of Un-plasticised Poly Vinyl Chloride(UPVC) (Fenesta/NCl/Veka Ltd) Three Track-Three Panel Sliding window -60- series duly manufactureed using upvc reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x 58mmx2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window frame shall be fitted with 6 mm thick clear toughened glass of Saint-Gobain make duly fixed with EPDM weathering seal resistant and the System is to be installed using reinforcement large coupler at the site using anchor fasteners, silicon, rubber, sealant, easy glazing/Deglazing at site etc. including cost and conveyance of all materials accessories labour charges amterials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards - WindowRENOVATION |
| 198 | CASUALTY |
| 199 | CASUALTY First Floor |
| 200 | OPD TICKET COUNTER |
| 201 | MAIN GATE |
| 202 | VentilationRENOVATION |
| 203 | CASUALTY |
| 204 | CASUALTY First Floor |
| 205 | PUBLIC TOILET |
| 206 | MAIN GATE |
| 207 | Supplying, fitting & fixing of M.S framed Grills, wherever requied. The Cost includes, cutouts, drilling, screws etc. complete RENOVATION |
| 208 | CASUALTY |
| 209 | CASUALTY First Floor |
| 210 | OPD TICKET COUNTER |
| 211 | PUBLIC TOILET |
| 212 | MAIN GATE |
| 213 | RCC DRAIN |
| 214 | Supplying, fitting, fixing of openable UPVC doors with door frame of approved make with 6 mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. RENOVATION |
| 215 | CASUALTY |
| 216 | CASUALTY First Floor |
| 217 | PUBLIC TOILET |
| 218 | MAIN GATE |
| 219 | Providing fitting fixing of approved make 35mm thick (Laminated Finished) factory made Flush Doors, of different sizes finished with 1mm thick laminate of approved shade and colour to both sides fixed to teak wood beading/ liping as per the design, whereever necessary the glazing portion of the door will be made out of 6mm thick glass with itiching as required to be fixed with 50x18mm /48x24mm teak beading finished with melamine polish / 1mm thick laminate.. The glass jointing shall be tightened with silicon or approved jointing material for proper rigidity. The door shall be provided with all necessary fittings and fixtures, i.e Godrej Ultra Veritibolt Lock (Model 1 CK) ,125x75x3 mm SS204 Hinges, approved make Door closer,Door Stoper etc with all accessories, labour T&P etc complete. RENOVATION |
| 220 | CASUALTY |
| 221 | CASUALTY First Floor |
| 222 | DOOR OPD TICKET COUNTER |
| 223 | Factory made single extruded WPC (Wood Polymer Composite) solidplain flush door shutter 35 mm thickRENOVATION |
| 224 | PUBLIC TOILET |
| 225 | Supply, fitting & fixing of WPC Choukat with size of 4\\"x\\"2.5\\" of saburi/amulya/ecoste branded make. The cost includes choukat, labour, accessories etc all complete RENOVATION |
| 226 | CASUALTY |
| 227 | CASUALTY First Floor |
| 228 | OPD TICKET COUNTER |
| 229 | PUBLIC TOILET |
| 230 | Supplying, fitting afixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect. RENOVATION |
| 231 | CASUALTY |
| 232 | CASUALTY First Floor |
| 233 | OPD TICKET COUNTER |
| 234 | PUBLIC TOILET |
| 235 | MAIN GATE |
| 236 | PAVER ROAD, PARKING & LANDSCAPING |
| 237 | Supplying, fitting and fixing, wrought & putup and hoisting the joist and trusses made out of Tata/Bhusan/Jindal make MS square pipes of 3\\" X 3\\" and 2\\" X 2\\" and purlins of 2\\"X2\\" square pipes with base plate of 12'X12\\" size including all cost of materials, labour, transportation to work site, welding and taxes etc. complete. RENOVATION |
| 238 | Labour for fixing of Tata/Bhusan/Jindal Make Aluminium semi corrugated colour sheet 0.5 in roof drilling holes in wind ties including fixing ridges and valleys etc complete.RENOVATION |
| 239 | Priming one coat with any approved primer including cost of primer for Iron workGround Floor RENOVATION |
| 240 | CASUALTY |
| 241 | OPD TICKET COUNTER |
| 242 | PUBLIC TOILET |
| 243 | MAIN GATE |
| 244 | RCC DRAIN |
| 245 | CASUALTY First Floor |
| 246 | Painting two coat with any approved paint on new wood/Iron workGround Floor RENOVATION |
| 247 | CASUALTY |
| 248 | OPD TICKET COUNTER |
| 249 | PUBLIC TOILET |
| 250 | MAIN GATE |
| 251 | RCC DRAIN |
| 252 | First Floor CASUALTY |
| 253 | Supplying of M.S Cow catcher of approved specification and approved quality with cost, conveyance, royalities and texes of all materials, all labour and T&P required for the work etc. complete in all respect as per the direction of Engineer-in-charge.MAIN GATE |
| 254 | 2.5cm thick grading concrete (1:2:2) on roof slab using 6mm size hard granite chips on new work..Ground Floor RENOVATION |
| 255 | First FloorRENOVATION |
| 256 | CASUALTY |
| 257 | Dismentaling brick or stone masonary in lime or cement mortar under 3mt.height including stacking the useful materials for reuse and removing the debries within 50mt.lead. |
| 258 | Dismentaling brick or stone masonary in lime or cement mortar above 3mt.height including stacking the useful materials for reuse and removing the debries within 50mt.lead. |
| 259 | Dismantlling and removing R.C.C. columns beams slab, staircase landing, lintels including stacking the useful materials for re-use and removing the debries within 50mtr lead.Ground Floor |
| 260 | First Floor |
| 261 | Dismentling and removing 2.5cm thick artificial stone flooring including stacking the useful materials for re-use and removing the debries within 50 mts.lead |
| 262 | Dismentling and removing of A.C. & G.C.I. Sheet including stacking the useful materials for re-use and removing the debries within 50 mts.lead |
| 263 | Dismentaling and removing doors,windows and ventilators including removal of frame,hinges,fastening and stacking the same for re-use and removing the debris within 50mts lead. |
| 264 | Removing old grading plaster from roof slab cleaning the surface, lowering and removing the debries within 50mts lead |
| 265 | Dismentling and removing of Old Tarfelt from Roof Slab and cleaning the surface including stacking the useful materials for re-use and removing the debries within 50 mts.lead |
| 266 | Removing old lime or cement plaster from walls including racking out joints 12mm deep and removing the debries within 50mts lead |
| 267 | Dismentalling & Removing Old Tiled flooring including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete.Ground Floor |
| 268 | Dismentalling & Removing Old Tiled cladding in wall including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete.Ground Floor |
| 269 | Carraige of earth by mecahnical means with cost of all lead & lift upto 5Km. including cost of all labour,T&P etc complete. |
| 270 | Providing & fixing Plain Calcium Silicate board ceiling 8mm thick board suspended from roof by adjustable G.I. ceiling angle with spread at a distance not more than 600mm fixed to roof by Rowl Plug & stiff cleat, Gupsum board 12.5mm thick held by G.I. perimeter channel MF-3 & intermediate channel MF-7, framing, boarding, jointing & finishing with special type of gypsum compound etc. including cost , conveyance & taxes of all materials, labour with T&P etc. complete in all respect as per the direction of the E-I-C.Ground Floor |
| 271 | ARMSTRONG GRID CEILING ( DUNE RH-99). The main G.I. runner spaced at 1200mm centre to centre securely fixed to the structural soffit using G.I. suspension system at 1200mm maximum centr to centre & not more than 150mm from spliced joints. The First/Last suspension system at the end of each main runner should not be greater than 600mm from the adjacent wall. 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm modules to be formed by fitting 600mm long cross tees centrally between the 1200 mm cross tees. Perimeter trim to be shadow wall angle (dimensions: 19x7x7x14mm), secured to walls at maximum 450 mm C/C, complete in all respect with all labour, material etc. as directed by the Architect/Engineer-in-Charge. The rate includes all complete with materials, labour, T&P, taxes etc. (Fixtures should be independently supported from the soffit). Ground Floor |
| 272 | Supply, fitting, fixing & installation of METALWORKS BAFFLE BLADE 100X50MM - WOOD - RED OAK/ CHERRY With accessories Armstong make. The cost includes boards, running tracks, channels, labour T&P Etc |
| 273 | Supplying, fitting, fixing of two track UPVC sliding window of approved make with 6 mm thick glass of approved quality complete with frame , shutters and all fitting and fixture |
| 274 | Supplying, fitting, fixing of openable UPVC doors with door frame of approved make with 6 mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 275 | Providing fitting fixing wooden panelling to Doors and Windows, whereever necessary panelling will be done with 12mm & 19mm fire resistant & termite proof BWP ply (confirming to I.S 5509) wherever required to be provided and finished with 1mm thick laminate of approved shade and colour as per the drawing. The rate inludes cost of cut-outs, fixation,other accessories, labour T&P etc complete. First Floor |
| 276 | Providing fitting fixing wooden panelling to walls, whereever necessary panelling will be done with 12mm & 19mm fire resistant & termite proof BWP ply(confirming to I.S 5509) wherever required to be provided and finished with 1mm thick laminate of approved shade and colour as per the drawing. The rate inludes cost of cut-outs, fixation,other accessories, labour T&P etc complete. First Floor |
| 277 | Providing fitting fixing Solid wooden Partition, whereever necessary panelling will be done with 12mm & 19mm fire resistant & termite proof BWP ply (confirming to I.S 5509) wherever required to be provided and finished with 1mm thick laminate of approved shade and colour as per the drawing. The rate inludes cost of cut-outs, fixation,other accessories, labour T&P etc complete. |
| 278 | Supply, fitting,fixing of laminated plywood make deck with glass covering as per design drawing |
| 279 | Supply, fitting & fixing of plywood wooden credenza size (0.9 H x 1.52 W x 0.5 D ) meter |
| 280 | P.H. Work-Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.20mm dia PVC pipe (Sch-80)Ground Floor |
| 281 | First Floor |
| 282 | 25mm dia PVC pipe(Sch-80)Ground Floor |
| 283 | First Floor |
| 284 | 32mm dia PVC pipe (Sch-80)Ground Floor |
| 285 | First Floor |
| 286 | 40 mm dia PVC pipe (Sch-80) top Floor |
| 287 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
| 288 | 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) |
| 289 | 15mm dia CP Bib cock (Con-CHR-047KN Jaquar make) |
| 290 | 15mm dia CP Long body Bib cock (Con-CHR-107KN Jaquar make) |
| 291 | 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
| 292 | 25mm dia CP Health Faucet (Jaquar Make)ALD - CHR - 565 |
| 293 | WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR) |
| 294 | 25mm dia brass full way valve (Shakti make) |
| 295 | 32mm dia brass full way valve (Shakti make) |
| 296 | 40mm dia brass full way valve (Shakti make) |
| 297 | 15mm CP Extension piece |
| 298 | 125mm CP grating |
| 299 | 15mm size C.P. flange |
| 300 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank roof of 1st Floor |
| 301 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.Ground Floor |
| 302 | First Floor |
| 303 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-chargeGround Floor |
| 304 | First Floor |
| 305 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.Ground Floor |
| 306 | First Floor |
| 307 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 308 | 80mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 309 | 110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
| 310 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 311 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 312 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 313 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 314 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 315 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 316 | 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 317 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 318 | 75mm U-PVC plain bend(Ori Plast/Finolex/Supreme Make) |
| 319 | 75mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 320 | 75x75x75mm U-PVC double equal door Tee(Ori Plast/Finolex/Supreme Make) |
| 321 | 75mm U-PVC vent cowl(Ori Plast/Finolex/Supreme Make) |
| 322 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 323 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-chargeEuropean water closet with 'S' trap plain(Hindware/Parryware/Neycer make) |
| 324 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 325 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with pedestal |
| 326 | Counter top basin oval shape 550mmx430mm (Hindware/Parryware/Neycer make) |
| 327 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge20mmx450mm long CP towel rail |
| 328 | Towel ring |
| 329 | Grab bar (Jaquar make) WAC - WHT - BAI 090 |
| 330 | 450MM long Grab bar (Jquar make)AHS - CHR - 1507 |
| 331 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeCP soap holder |
| 332 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails. |
| 333 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.600mmx450mm size B.E mirror (swivelled type) |
| 334 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge.CP revolving Shower (bend Type) |
| 335 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge stall urinal |
| 336 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 337 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 338 | Supplying all materials labour & laying the waterproofing material of Dr. fixit torch shield P3160(3mm) with its primer 2 coats or equivalent water proofing materials after drying cleaning the concrete surface over the concrete floor/roof/balcony/ sunken and dado upto1'6\\" in wall including cleaning, applying and mending as per specification including cost, conveyance, taxes, royalities of all materials to worksite etc. all complete as per the direction of the Engineer- in- charge. First Floor |
| 339 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 120 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 120 liter's along with 3 noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in chargeAqua guard pure Chill 80 PSS UV |
| 340 | External P.H. workSupplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge110mm dia u-pvc pipe alround concrete |
| 341 | 160mm dia u-pvc pipe alround concrete |
| 342 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge |
| 343 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-chargeInside size 76cmx76cmx46cm with 18” dia RCC MH cover |
| 344 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 345 | 2 Septic tank, 2 soak pit, man hile & Gully TrapEarth work excavation in all kinds of soil within initial lead of 50 m. And initial lift of 1.5 m. including rough dressing and leveling the bed. |
| 346 | Supplying & filling foundation and plinth with course sand well watered and rammed including cost, cost of all labour, carriage, royalty, etc complete. |
| 347 | C.C (1:4:8) with 4cm size Hand BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C |
| 348 | C.C (1:3:6) with 4cm size Hand BROKEN metal including all cost, conveyance,royalty & taxes etc.comp.to work site as per specification approved by the department & direction of E.I.C |
| 349 | R.C.C. work of m-20 using 20mm and down graded hard granite Crusher broken chips including laying, hoisting, Centring & shuttering with all cost, conveyance etc. complete.Slab |
| 350 | Plate |
| 351 | Supplying fitting & placing uncoated HYSD reinforcement including cutting, bendind,binding & placing the steel rods as per drawing & technical specification with cost of binding wire 18 to 20 gauge |
| 352 | Brick work with Fly ash Bricks 23cm x 11cm x 8cm size having crushing strength not less than 75Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in Foundation and Plinth including watering curing, cost of carriage and royalty of all materials, cost of all labour, etc complete. F&P |
| 353 | 12mm thick cement plaster (1:4) for brick work with cement punning for skirting . |
| 354 | Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessoriesLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore00 mtr to 30mtr |
| 355 | 31 mtr to 45mtr |
| 356 | Drilling of 150mm dia bore46 mtr to above |
| 357 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200mm dia P.V.C casing pipes00 mtr to 45 mtrs |
| 358 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.200mm dia PVC (sch-80) pipe |
| 359 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 360 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in chargeBy DTH Rig |
| 361 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:Rocky terrain with boulder formation for 300m depth |
| 362 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) 1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) |
| 363 | DOL Control panel |
| 364 | 40mm dia steel short piece |
| 365 | Well cap |
| 366 | 50mm size CI bracket |
| 367 | 2.50sqmm flat cable |
| 368 | 20mm dia rigid UPVC pipes |
| 369 | Steel rope with cover |
| 370 | Labour charges for lowering including transportation |
| 371 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge32mm HDPE pipes (Finolex/Supreme make) |
| 372 | E.L Work-Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A |
| 373 | GROUP-B |
| 374 | GROUP-C |
| 375 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 376 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 377 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 378 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 379 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 380 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 381 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 382 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 383 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 384 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 385 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 386 | Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 387 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 388 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 389 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 390 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator) |
| 391 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of not more than 25W and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2 years. |
| 392 | Supplying and fixing of Energy efficient recessed mounted LED luminaire made up of CRCA powder coated housing, Top opening clean room LED luminaire of 600 X 600 x 65 mm size with of 45 W and system lumens output not less than 4500 lumens , IP65 ,dust free & zero maintenance , anti glare high transmittance PMMA diffuser , operating volatge range 150-265 V, high performance potentiometric electronic driver for zero maintenance , 2.5 KV internal urge protection, L70 B 50: 50,000 hrs., CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,,IP 65 protection complete with all other accessories suitable for operation on 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2years. .Each CLEAN ROOM FITTING . |
| 393 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 394 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 395 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 396 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 397 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 398 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years |
| 399 | 2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years |
| 400 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD)Warranty on DB is 3 years |
| 401 | Supplying and fixing 20 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 402 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years. |
| 403 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years. |
| 404 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years |
| 405 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 406 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 407 | CABLING AND END TERMINATION MAIN AREASupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 240 sq mm (2 run from TRF to Main LT Panel) |
| 408 | 3.5core x 120 sq mm ( DG PANEL 2 RUNS ) |
| 409 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 95 sq mm ( FOR FDB 1F,2F, POWER ) |
| 410 | 4core x 16 sq mm (BDB LIGHT /POWER,EQUIPEMENT ) |
| 411 | 4 core x 6 sq mm (for small power) |
| 412 | 3.5core x 35 sq mm (To FDB LIGHT / power BDB/UPS PANEL,separate panel for OT Complex,MCU) |
| 413 | 3.5core x 50 sq mm (From main panel to light floor distribution panel) |
| 414 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 415 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 416 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 417 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 418 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 419 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 420 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 421 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 422 | Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x240 sq mm |
| 423 | 4 core x16sq mm |
| 424 | 3.5 core x35 sq mm |
| 425 | 3.5 core x95 sq mm |
| 426 | 3.5 core x120 sq mm |
| 427 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia |
| 428 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 200 mm dia |
| 429 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 430 | Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT. |
| 431 | S/F of Street light- 90W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 432 | Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat as per direction of Engg. in Charge. |
| 433 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 434 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 435 | Supplying, Erection, Fixing, connection & testing of Panasonic 40 LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 436 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years |
| 437 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 438 | Supplying,installation,testing & commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 32A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 32 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB as outgoing Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 3 years of acceptance of materials |
| 439 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
| 440 | Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 32mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender