Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #56467207

Tender For Repair/ Maintenance Of Various Building Security Light, Flood Lights, Highbay Lights And Other Connected Works Under Ge Narangi

Issued by Statutory Bodies & Commissions/Committees · Kamrup Metro, Assam
Tender Value
40 Lakhs
Estimated cost
Bid Submission
04 Aug 2026
8 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Various Building Security Light, Flood Lights, Highbay Lights And Other Connected Works Under Ge Narangi

BOQ

Name of Work:-
Sl. No. Item Description
1Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
2Material and labour for Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FR-LSH grade cable conforming to IS-694 1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
3All as per item No 2 here-in-before but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables complete all as specified and directed.
4All as per item No 2 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board complete all as specified and directed.
5All as per item serial No 2 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches complete all as specified and directed.
6All as per item No 2 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly complete all as specified and directed.
7Suppy and fix switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and directed.
8Suppy and fix Bell push switch, flush type, 5 Amps 230 volt complete all as specified and directed.
9Suppy and fix socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and directed.
10Suppy and fix switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and directed.
11Suppy and fix switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and directed.
12Suppy and fix ceiling rose surface bakelite 65x50mm three terminal complete all as specified and directed.
13Suppy and fix lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as specified and directed.
14Suppy and fix stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
15Suppy and fix Ding Dong AC. 230 volts,single pole complete all as specified and directed.
16Suppy and fix in repair factory made, sheet steel distribution boards, TPN, 4 Way, double door IP-43,with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
17Supply fix in repair MCCB DB IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
18Supply fix in repair MCB DB of sheet metal enclosure IP-43 double door SPN 8 way with 200 A rated bus bar and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
19Suppy and fix in repair MCB Tripple pole & neutral 40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified and directed.
20Suppy and fix in repair for MCCBs 415 V, 16 KA, 4P, 63 Amps complete all as specified and directed.
21Suppy and fix in repair for MCCBs 415 V, 16 KA, 4P, 100 Amps complete all as specified and directed.
22Suppy and fix in repair MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and directed.
23Suppy and fix in repair MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and directed.
24Material and labour for sub main wiring with two runs (P-N) of single core 1.5 Sqmm (nominal area) FR-LSH PVC insulated and unsheathed copper conductor cable 1100 volts grade having multi-stranded copper conductor with earthing cable of FR-LSH PVC insulated and unsheathed multi-stranded copper conductor of size 1.5sqmm single core as earth continuity wire drawn through PVC conduit complete all as specified and directed. (Two single core 1.5 Sqmm cable and one single core 1.5 Sqmm earth conductor cable shall be measured as one run).
25Material and labour for wiring with 2 runs of 2.5 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old wiring and type of conduit complete all as specified and directed. Note: 2 run of 2.5 Sqmm cable and 1 run of 2.5 Sqmm cable along with conduit altogether shall be measured as one unit.
26Material and labour for Sub main wiring with 2 runs of 6.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.
27Material and labour for Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.
28Taking down old UNSV bulkhead/security fitting type and Supply and fixing in repair LED building security light of capacity 30 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection upto 10kV including connection with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmmX 3 core from light fitting to ceiling rose complete all as specified and directed.
29Taking down old UNSV bulkhead/security fitting type and Supply and fixing in repair LED building security light of capacity 45 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection upto 10kV including connection with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmmX 3 core from light fitting to ceiling rose.complete all as specified and directed.
30Taking down old UNSV bulkhead/security fitting type and Supply and fixing in repair LED building security light of capacity 60 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection upto 10kV including connection with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmmX 3 core from light fitting to ceiling rose.complete all as specified and directed.
31Taking down old UNSV flood fitting type and Supply and fixing in repair LED flood light of capacity 50 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection upto 10kV including connection with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmmX 3 core from light fitting to ceiling rose.complete all as specified and directed.
32Taking down old UNSV High bay fitting type and Supply and fixing in repair LED High bay light of capacity 50/60 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover including electronic driver should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5700±300,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection upto 10kV including connection with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmmX 3 core from light fitting to ceiling rose.complete all as specified and directed.
33Supply and fixing in repair batten type LED light fitting 1x 20W, 220V,AC decorative type including flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
34Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed /surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
35Suppy and fix in repairs 18 watt LED recessed/surface mounted luminaire with high brightness LED for glare-free homogenous illumination suitable for Armstrong/grid ceiling and fixture complete all as specified and directed.
36Suppy and fix in repair LED 35/40 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and directed.
37Suppy and fix in repair LED surface/recess mounted round downlighter 15 W with pressure die-cast sink and PC difuser in chrome finish diffuser with integrated driver complete all as specified and directed.
38Suppy and fix in repair of unsv switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and directed.
39Suppy and fix in repair/ replacement of unsv socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and directed.
40Suppy and fix in repair of unsv switch socket combination outlet 2-in-1, 5 Amp flush type complete all as specified and directed.
41Suppy and fix in repair/ replacement of unsvr switch socket combination multipurpose, 2 in 1, 3 pin, 5 & 15 Amp flush type complete all as specified and directed.
42Suppy and fix in repair/ replacement of unsv socket outlet 3 Pin 15 Amp 240 volts complete all as specified and directed.
43Supply and fix in repair PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep for mounting switches complete all as specified and directed.
44Suppy and fix in repair/ replacement of unsv fan capcitor 2.5 Mfd suitable for 1200/1400mm sweep ceiling fan complete all as specified and directed.
45Supply & fixing and testing of Antique bollard light upto 20W, 230 volts or nearest size with die cast aluminium lighting with high power LED with B22 holder as light source body , IP-65, with all necessary fixing arrangments, exacavation work ,PCC work and earth work etc complete all as specified and directed.
46Suppy and fix in repair LED post Light with B22 holder up to 20 w bulb with white cover diffuser including plastic base plate suitable complete all as specified and directed.
47Supply and fix in repair for street light bracket made out of 40mm bore medium grade GI pipe ( minimum length 1.50 mtr) with including 2X MS clamp of flat iron not less than 40X 6 mm with anchor fastner for fixing on wall duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer on steel surfaces all as specified & directed by Engr-in-Charge.
48Material and labour Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 8 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old Earthing chamber . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56467207
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 04-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Various Building Security Light, Flood Lights, Highbay Lights And Other Connected Works Under Ge Narangi
Basic Detail
Tender No 8241/B/E8
Bidding Type Tender
Location
City Kamrup Metro
State Assam
Key Dates
Publish Date 15 Jul 2026
Submission Date 04 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
75a78434-c779-42b9-a04d-83a9c3a45c7d.html
8241Tender.pdf
BOQ_872039.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.