Tender For Rep/Maint Drainage,Compound Wall ,Fencing, Hardstanding Shed, Footpath, Culvert, Drain Covers Etc At E/M Installations Of Zone ‘A And Repair/Replacement Of Electrical Wiring Including All Connected Electrical Fittings And Fixtures At Aro,
Tender Overview
Project Description
Tender for Rep/Maint Drainage,Compound Wall ,Fencing, Hardstanding Shed, Footpath, Culvert, Drain Covers Etc At E/M Installations Of Zone ‘A And Repair/Replacement Of Electrical Wiring Including All Connected Electrical Fittings And Fixtures At Aro, Stn Hq, Apo Otm & Md Accns Under Ge (I) Gos
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed. |
| 2 | M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed. |
| 3 | M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 4 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 5 | M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in Surface channels and drains etc complete all as specified and directed. |
| 6 | M&L Random rubble masonry walling well bonded, bedded, solidly hearted, uncoursed built in CM 1:6.Complete all as specified and directed. |
| 7 | M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 8 | M&L brick work with old size sub class 'B' brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including all quoins, arches, pillars etc, but except bricks complete all as specified. Note: The bricks shall be used as obtained from demolition of brickwork from Ser No 01 above. |
| 9 | M&L for rendering 20 mm thick in CM 1:6 on stone masonary surface, finishing even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed. |
| 11 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 12 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 13 | M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed. |
| 14 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 15 | M&L for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 16 | M&L for Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed |
| 17 | M&L for Removing excavated material (Soil) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 18 | S&F pre- painted galvalume aluminum zinc corrugated steel based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping serews as specified and directed by Engr - in - Charge. |
| 19 | Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and directed. |
| 20 | M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 21 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 22 | Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out making good the disturbed surface if required in soft/ loose soil complete all as specified and directed. |
| 23 | M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete all as specified and directed. |
| 24 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for. Complete all as specified & directed. |
| 25 | M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening anf fixing complete all as specified and directed. |
| 26 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 27 | M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc all as specified and directed by Engr - in - Charge. |
| 28 | M&L preparation of new steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge |
| 29 | S&F prepolished coloured machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified & directed. |
| 30 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 31 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed. |
| 32 | M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 33 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path/ hard standing surface finished even and fair complete all as specified and directed. |
| 34 | M & L for 75 mm thick PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement including demolition of cement concrete in plinth protection ground floor complete all as specified directedNote :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3). |
| 35 | M&L Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and directed. |
| 36 | M&L for providing Glass strip of 6 mm thick and 40 mm deep in hardstanding for making panels complete all as specified and directed. |
| 37 | M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed. |
| 38 | M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed. |
| 39 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed. |
| 40 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 41 | S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 42 | S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 43 | M&L for finishing cement concrete even and smooth using extra cement complete all as specified and directed. |
| 44 | M&L for Cleaning and removing all scale and dirt, etc, from RCC/PVC tanks exc 250 ltr n.exc 500 ltr capacity incl washing of water tank with the use of Tank cleaning motor jet pressure machine and using bleaching powder @ 0.25 Kgs per tank with writing the date of cleaning with any type of paint and from mouths of circulating pipes, including Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 45 | S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 46 | S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 47 | S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 48 | S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 49 | Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 50 | M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed. |
| 51 | M&L for preparing new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed |
| 52 | M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 53 | Dismantling posts or sturts (wood,steel or RCC) any section incl taking out embedded portion and making good disturbed ground etc all as specified and directed. |
| 54 | Dismantling fencing wire mesh any type etc all as specified and directed. |
| 55 | S&F Angle iron posts and rails,drilled and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc, flat iron fillets (for secruing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165. |
| 56 | Mild Screw bolts (Machine made) with hexagonal or square head at one ends and to fitted with washers and one hexagonal or square n.exc 15cm long, dia of neck 11 to 15mm all as specified and directed by Engr-in-Charge. |
| 57 | Fixing only chain link fencing including line wire, any mesh, any size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 58 | Supply only PVC coated chain link of 3.16mm dia mild steel galvanised fencing of mesh size 75 mmx 75mm as per IS : 2721-2003 weight n exc 4.00 kg per sqm complete all as specified and directed by Engr - in - Charge. |
| 59 | S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified & directed. |
| 60 | M&L for writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 cm high etc complete all as specified and as directed by Engineer-in-Charge. (Note : Rates to be deemed fit for all security measures while working in heights more than 6m from GL). |
| 61 | M&L 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 62 | M&L applying one coats Cement based paint on old decorated wall surfaces, includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 63 | M&L applying two coats Cement based paint on old decorated wall surfaces, includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 64 | M & L for2 coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification after Preparation of plastered surface including a coat of primer on prepared surfaces including, rubbing with sand paper and applyingn. ( Plastic Emulsion Paint) |
| 65 | M&L applying One coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces/ old decorated wall surfaces, in case of old decorated wall surfaces includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 66 | M&L applying two coats of acrylic exterior weather proof emulsion paint over a coat of exterior primer on newly plastered wall surfaces/ old decorated wall surfaces, in case of old decorated wall surfaces includes complete removal of existing wall finish of any type with wire brush, brooming, dusting & finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc complete all as specified and directed. |
| 67 | M & L for ACP Green glow sign Road Sign Boards of size .90 x 0.45 Sqm Shape: Rectangle with stainless steel poles of 40 mm dia all as specified and directed by Engineer in Charge . |
| 68 | Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made for conditions separately ) and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing without andulations complete all as specified and directed.( Note:- All credit materials should be deposited in MES yard as available on work site the same materials should be issued to contractor through gate pass as per contract schedule of credit materials against contract agreement or taken on ledger with approval by accepting officer). |
| 69 | Material and labour for cutting chasing,pinning of brick/ stone/concrete wall at any height wall cutting and chases for concealed wiring for 20/25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed |
| 70 | M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed, multistranded, single core, copper cable 1100 volts grade cables drawn through in PVC Conduit 20/25 mm dia medium grade ISI marked (MMS) at any height/places and all accessories are concealed in walls / roofs / floors / ceiling etc. including suitable arrangements for flush mounting modular MS/GI boxes as per site requirement/suitable for modular top cover and frame for fixing of modular switches,sockets,fan regulators, blank plate etc and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directed for the following:-(a) One light point controlled by one 10amps switch. |
| 71 | (b) All as per item no 70 but for One fan point controlled by one switch 10 amps, and one regulator. |
| 72 | (c) All as per item no 70 but for One exhaust fan point controlled by one 10 amps switch . |
| 73 | (d) All as per item no 70 but for One 5 pin 6 amps socket point controlled by one 10 amps switch on independent board . |
| 74 | (e) All as per item no 70 but for One 5 pin 6 amps socket point controlled by one 10 amps switch on same board . |
| 75 | (f) All as per item no 70 but for One bell/buzzer point controlled by one bell push. |
| 76 | (g) All as per item no 70 but for One light point controlled by two 2 way switches/bed switch point |
| 77 | All as per item No.73 & 74 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm incl circuit wiring complete all as specified and directed for the following:-(a) One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on independent board. |
| 78 | (b) All as per item no 77 but for One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on same board. |
| 79 | All as per item No.73 above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm incl circuit wiring complete all as specified and directed. |
| 80 | M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed, multistranded, single core, copper cable 1100 volts grade cables drawn through PVC casing and caping 20/25 mm width double locking medium grade ISI marked (MMS) at any height and all accessories such as Tee,bend,short piece & elbow on surface on walls / roofs / floors / ceiling etc. including providing suitable arrangements for flush mounting modular MS boxes as per site requirement/suitable for modular top cover and frame for fixing of modular switches,sockets,fan regulators, blank plate etc and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directed for the following: (a) One light point controlled by on switch |
| 81 | (b) All as per item no 80 but for One fan point controlled by one switch and regulator |
| 82 | (c) All as per item no 80 but for One exhaust fan point controlled by one switch. |
| 83 | (d) All as per item no 80 but for One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . |
| 84 | (e) All as per item no 80 but for One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . |
| 85 | (f) All as per item no 80 but for One bell point controlled by one bell push. |
| 86 | (g)All as per item no 80 but for One light point controlled by two 2 way switches. |
| 87 | All as per item No.83 &84 above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm and incl providing circuit wiring complete all as specified and directed for the following:-(a) One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board. |
| 88 | (b) All as per item no 87 but for One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board. |
| 89 | All as per item No.83 above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm incl providing circuit wiring complete all as specified and directed. |
| 90 | Supply & fixing and fixing in repairs modular type switch 10 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 91 | Supply & fixing and fixing in repairs modular type switch 10 Amps ,2way,single pole,1 module,240V,AC, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 92 | Supply & fixing and fixing in repairs modular type bell push 6 Amps,1 module, single pole, 240 volts,AC, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 93 | Supply & fixing and fixing in repairs modular type switch 16 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 94 | Supply & fixing and fixing in repairs modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed by Engr-in-Charge |
| 95 | Supply & fixing and fixing in repairs modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module,240V,AC ISI Marked complete all as specified and directed by Engr-in-Charge |
| 96 | Supply & fixing and fixing in repairs red color lighting indication lamp 6 Amps, single pole,240volts,AC,50 Hz suitable for 1 module ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 97 | Supply & fixing and fixing in repairs modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 0 to 4/5 steps, ISI Marked complete all as specified and directed by Engr-in-Charge. |
| 98 | Supply & fixing and fixing in repairs call bell AC, 230 Volts single pole, multi music type ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 99 | Supply & fixing and fixing in repairs call bell ding dong AC, 230 Volts single pole, multi music type ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 100 | Supply & fixing and fixing in repairs angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed by Engr-in-Charge. |
| 101 | Supply & fixing and fixing in repairs ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed by Engr-in-Charge. |
| 102 | Supply & fix decorative box type 20 watt light fitting,blue coloured end caps, pre-wired and including providing single/double side LED tubelight(tube rod) white/warm 20 watt-01 No made of aluminium extrusion with high efficient LED driver,IP-20, including PVC/Wooden round/square block -02 Nos and connected with LED fitting to ceiling rose and including removing old unserviceable fitting complete all as specified and directed by Engr-in-Charge. |
| 103 | Supply & fix decorative box type 9 watt light fitting,blue coloured end caps, pre-wired providing single side LED tube 9 watt-01 No, and including PVC/Wooden round/square block -02 Nos and connected with LED fitting to ceiling rose and including removing old unserviceable fitting complete all as specified and directed by Engr-in-Charge. |
| 104 | Supply and fixing, in repairs 20 watt LED pride plus batten white decorative type,high quality materials,240V,50Hz, and slim integrated body,easy to install,,PC diffuser and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed by Engr-in-Charge. |
| 105 | Supply & fixing, in repairs 40 watt LED light fitting white lighting, high quality materials and intergrated design, PC diffuser, reliable and robust housing structure, easy to install, efficency 125 lm/w necessary arrangements for fixing with LED fitting to ceiling rose complete all as specified and directed by Engr-in-Charge. |
| 106 | S & F Energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired of luminaires including LED light driver and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed by Engr-in-Charge. |
| 107 | Supply & fixing , in repairs LED bldg secruity light fitting sensor based of capacity 35 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection and including removing of old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 108 | Supply and fix GI bracket pipe of size 25 to 32 mm dia as suitable medium grade of 1.2 mtr long bent to shape suitable degree of bending as per site requirement with hot or cold bending method of process for making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on wall surfaces and including providing suitable fabricate galvanised flat iron clamps of 20X4 mm thick -02 Nos suitable for fixing at any place/height with hole fastners,nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 109 | Supply & fixing , in repairs in sheet metal enclosure, 415 volts AC,TPN DB, 4 way,8+12 modules, flush mounting with copper busbar, 2 neutral/earth bars links and MCB incomer, and MCB SPN/SP/TPN as outgoing and complete for IP43&54 DBs protection and including removing old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed by Engr-in-Charge. |
| 110 | Supply & fixing , in repairs in sheet metal enclosure, double door ,415 volts AC,VTPN DB, 4 way,8+12 modules, flush mounting copper busbar, 2 neutral/earth bars links and MCCB incomer, and MCB SPN/SP/TPN as outgoing and complete for IP43&54 DBs protection and including removing old unserviceable DBs and incl making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed by Engr-in-Charge. |
| 111 | Supply & fixing , in repairs sheet metal enclosure, double door, 240 volts AC,SPN,DB, 12 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed by Engr-in-Charge. |
| 112 | Supply & fixing in repairs sheet metal enclosure, double door, 240 volts AC,SPN,DB, 8 way, flush mounting with 100amps copper busbar,neutral bar,earth bar links and MCB incomer MCB SPN/DP and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs and making good the disturbed surfaces to match with existing surface and colour shade acomplete all as specified and as directed by Engr-in-Charge. |
| 113 | Supply & fix and fixing in repairs and sheet metal enclosure, with acrylic type double door, 240 volts AC,SPN,DB, 4 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP, and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed by Engr-in-Charge. |
| 114 | Supply & fix and fixing in repairs MCB SP 6 to 32 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed by Engr-in-Charge. |
| 115 | Supply & fix and fixing in repairs MCB SPN 32 to 40 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed by Engr-in-Charge. |
| 116 | Supply & fix and fixing in repairs MCB SPN 40 to 63 Amps 10 KA,\\"C\\" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed by Engr-in-Charge. |
| 117 | Supply & fix and fixing in repairs MCB TPN 40 to 63/100 Amps 10 KA,\\"C\\" series,AC,440Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed by Engr-in-Charge. Make:-Legrand /Havells/ Hagar/Schneider approved by GE |
| 118 | M & L for sub main wiring complete in repairs with 2 run of 10 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn drawn through and including PVC conduit in concealed ISI marked medium grade(MMS) accessories such as Tee,corner, overlaping connector etc and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed.Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. |
| 119 | All as per ditto item No 118, but 2 run x 6 sqmm+1 run earth wire complete all as specified and directed. |
| 120 | All as per ditto item No 118, but 2 run x 4 sqmm+1 run earth wire complete all as specified and directed. |
| 121 | All as per ditto item No 118, but 2 run x 2.5 sqmm+1 run earth wire complete all as specified and directed. |
| 122 | All as per ditto item No 118, but 2 run x 1.5 sqmm+1 run earth wire complete all as specified and directed. |
| 123 | Supply & fix and fixing in repairs suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C 'series, 230 Volts,50Hz suitable for AC's/Geysers complete all as specified and directed by Engr-in-Charge. |
| 124 | Supply & fix and fixing in repairs MCCB, 125 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item complete all as specified and as directed by Engr-in-Charge. |
| 125 | Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed. |
| 126 | S&F for PVC non-metalic rigid conduit incl boxes,junctions boxes 1 to 4 way & terminals but incl of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers lock nuts,saddles,pipes hookes etc ISI marked heavy duty of size 20/25 mm dia for LAN,telephone and TV connections cablesincluding cutting,chasses and making good disturbed surfaces to match with existing surfaces with plaster/putty and including removing of old unserviceable item complete all as specified and directed. |
| 127 | Supply & fix and fixing in repairs copper conductor cable, PVC insulated, sheathed,flexible, multistranded,ISI marked, 1100 volts grade 3 core ;2.5 sqmm and including electric connection through PVC conduit in concealed/casing caping in surface from ceiling fan to ceiling rose and including removing old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 128 | Supply & fix and fixing in repairs 40 watts LED post top lantern made in cast aluminium spigot housing with decorative opal polycarbonate diffser and IP65 protection and providing suitable fixing arrangements ,nuts,bolts and washers and including removing old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 129 | Supply & fix and fixing in repairs LED flood light light fitting of capacity 120 Watt LED, light fitting in aluminium PDC housing, toughened glass cover with IP-65 protection and including removing of old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 130 | Supply & fix and fixing in repairs LED flood light light fitting of capacity 100 Watt LED, light fitting in aluminium PDC housing, toughened glass cover with IP-65 protection and including removing of old unserviceable item complete all as specified and directed by Engr-in-Charge. |
| 131 | Supply and fixing and in repairs galvanised metal flush box 1/2 module, ISI marked,and suitable for existing type as per site requirement and including removing old unserviceable item from existing loaction complete all as specified and as directed by Engr-in-Charge. |
| 132 | All as per item No-131 ditto but meteal box 3 module |
| 133 | All as per item No-131 ditto but meteal box 4/5 module |
| 134 | All as per item No-131 ditto but meteal box 6 module |
| 135 | All as per item No-131 ditto but meteal box 8/9 module |
| 136 | All as per item No-131 ditto but meteal box 12 module |
| 137 | All as per item No-131 ditto but meteal box 16 module |
| 138 | All as per item No-131 ditto but meteal box 18 module |
| 139 | Supply and fixing in repairs modular white/wood/glazed type cover plate with frame 1 module,ISI marked and suitable for existing type as per site requirement and incl screws,washears etc and including removing old unserviceable item from existing loaction complete all as specified and as directed by Engr-in-Charge. |
| 140 | All as per item No-139 ditto but modular white/wood/glazed type cover plate with frame 2 module |
| 141 | All as per item No-139 ditto modular white/wood/glazed type cover plate with frame 3 module |
| 142 | All as per item No-139 ditto but modular white/wood/glazed type cover plate with frame 4/5 module |
| 143 | All as per item No-139 ditto modular white/wood/glazed type cover plate with frame 6 module |
| 144 | All as per item No-139 ditto but modular white/wood/glazed type cover plate with frame 8/9 module |
| 145 | All as per item No-139 ditto but modular white/wood/glazed type cover plate with frame 12 module |
| 146 | All as per item No-139 ditto but modular white/wood/glazed type cover plate with frame 16 module |
| 147 | All as per item No-139 ditto butmodular white/wood/glazed type cover plate with frame 18 module |
| 148 | Supply and fix in repairs of PVC/bakalite sheet round cover blanking plate as per site requirement with screws of existing fan junctions/ wiring junctions boxes etc |
| 149 | M&L for preparation of new plastered of wall/ceiling or concrete surface of walls or concrete and applying two coats of 3 mm thick wall care putty complete all as specified and directed |
| 150 | M&L for preparation of old decorated surface of wall and apply two coats of white wash complete all as specified and directed |
| 151 | M&L for applying two coats of oil bound distember on wall or concrete over a coat of primer on prepared surfaces including,rubbing with sand paper after complete removal of existing treatment complete |
| 152 | Supply & Fixing of SITC of LED Patient bed head light with Up-Down twin side glow 20W+20W batten type wall mounted luminaire. CCT 6500K (CW) on down side & 3000K (WW) on up side & total system lumen not less than 2000Lm on each side. Color Rendering Index (CRI) ≥80, long life of 35000hrs of operation, Fully diffused optics with eye comfort technology, Inbuilt electronic driver, PF >0.90 and THD <20% with operating voltage 160-270V AC, 50Hz. Inbuilt surge protection minimum 2.5 KV, complete in all specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender