Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #56467110

Tender For Repair And Maintenance Of Street Lights , Security Lights, Solar Lights And Allied Works At Anarwala Under Age E/M -Ii Of Ge Dehradun.

Issued by Statutory Bodies & Commissions/Committees · Dehradun, Uttarakhand
Tender Value
32 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
4 days left
EMD
64000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Street Lights , Security Lights, Solar Lights And Allied Works At Anarwala Under Age E/M -Ii Of Ge Dehradun.

BOQ

Name of Work:- Repair and Maintenance of street lights , security lights, solar lights and allied works at Anarwala under AGE E/M -II of GE Dehradun.
Sl. No. Item Description
1DESCRIPTION OF ITEMS
2Supply and fixing in repair of LED light fitting driver suitable for 25-45 watts fittings as per sample complete all as specifeid & directed.
3Supply and fixing in repair of LED light fitting driver suitable for 60-100 watts fittings as per sample complete all as specifeid & directed
4Supply and fixing in repair of surge protection device 10 KV 240 Volts suitable for LED street light fitting complete all as specified and directed.
5Supply and fixing of power contactors 4 pole 40-80 Amps AC3 in control of timer as per existing one etc incl taking down existing and necessary connection complete all as specifeid & directed.
6Supply and fixing of power contactors 4 pole 9-25 Amps AC3 in control of timer etc complete as per existing one incl taking down existing and necessary connection complete all as specified and directed.
7Supply and fixing of coil for contactor 40 Amps to 80 Amps as per existing sample complete incl taking out existing and necessary connections complete all as specified and directed.
8Supply and fixing of coil for contactor 9 Amps to 25 Amps as per existing sample complete incl taking out existing and necessary connections complete all as specified and directed.
9Supply and fixing in repair of MCB SP 6 to 32 Amp 'C' series 10 KA repturing capacity including connection with suitable size copper lugs complete all as specified and directed.
10Supply and fixing in repair of MCB isolator SPN 40 Amp 240 V AC 10 KA repturing capacity including connection with suitable size copper lugs complete all as specified and directed.
11Supply and fixing in repair MCB TPN 63 Amps rating 240V, 10KA 'C' curve including connection with suitable size copper lugs complete all as specified and directed.
12Taking down and dismantling of Street light fittings of any size and model (FTL ,ES,HPSV,MVL,MH,Flood light fitting,garden/gate lts etc) and depositing the same to MES store yard for repair if any required or as directed by Engr- in-charge complete all as specified and directed.
13Fixing only of street light taking down against the item here and above but after repair and replacement of unserviceable spares/accessories for the same including refixing the street light fittings of any size ,type and model of existing pole ,including existing pole, including neccessary electric connection by providing PVC insulated and sheathed aluminium conductor cable of 3 single core of size 2.50 sqmm (nominal cross sectional area) from junction box to fittings incl testing complete all as specified and as directedNote : divers,surge protector shall be measured and paid & separately under relevent items
14Supply and fixing in replacement of street light timer suitable for out door operation, infrared sensor, as per seasonal variation of daylight complete with contactor, relay, MCB, sensor etc, auto - manual faclity duly complete wiring suitable for 15 KW capacity Single pole 230 Volt AC including GI clamping & fixing to pole with IP-65 a weather proof & out door type IK09 protection complete all as specified and directed.
15Supply and fixing of timer astronomical digital type in repair incl taking out existing timer and necessary connection complete all as specified and directed.
16Supply and fixed in repair of GI bracket made out of 40 mm GI pipe medium grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps 02 Nos not less than 50x6 mm MS flat duly painted, nuts, bolts and washer complete all as directed.
17Supply only of 3 core 1.5 Sqmm copper conductor cable in existing pole incl making holes for cable entry and exist near to light fitting and junction box complete all as directed.
18Supply and fixing in replacement of flood light ,70 W,Outdoor type with high power LED's as light sources . Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing with dedicated heat sink and toughened glass with inbuilt control grar woth IP66,CCT :5700K,Efficacy : 100 Im/W,Impact resitace of IK07 and integrated driver with 5 KV inbuilt surge protection complete all as specified and directed.
19Supply and fixing in replacement flood light ,120 W,Outdoor type with high power LED's as light sources . Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing with dedicated heat sink and toughened glass with inbuilt control grar woth IP66,CCT :5700K,Efficacy : 100 Im/W,Impact resitace of IK07 and integrated driver with 5 KV inbuilt surge protection complete all as specified and directed.
20Supply and fixing in replacement flood light ,200W OR higher Outdoor type with high power LED's as light sources . Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing with dedicated heat sink and toughened glass with inbuilt control grar woth IP66,CCT :5700K,Efficacy : 100 Im/W,Impact resitace of IK07 and integrated driver with 5 KV inbuilt surge protection complete all as specified and directed.
21Supply and fixing in relacement Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65/66 protection road way luminaries with high power LED 45 watt with Efficacy 110 Lm/W,CCT :5700 K with potted 5KV internal and 10 KV external inbuilt surge protection complete all as specified and directed.
22Description all as per item No 20 above but light fitting of 70 watt complete all as specified and directed.
23Description all as per item No 20 above but light fitting of 90 watt complete all as specified and directed.
24Supply and fixing of LED decorative post top lantern for Garden light 20 watt IP 65 protection resistance to impact and corrosion glare, free and better uniformity milky version including taking down old unserviceable post of lantern.
25Supply and fixing of LED bollard type fitting 10 watt capacity inverted Pyramid Tripod type with soft 360 degree distribution with IP 65 protection ,complete with necessary PCC foundation including taking down existing old pattern unserviceable light fittings complete all as specified and directed .
26Supply and fixing of all in one LED solar street light fitting IP66 of capacity 30 watt made up of aluminium housing with mono crystalline solar panels for higher efficiency including in built high quality lithium ferrophosphate (LiFePO4) battery of capacity minimum 240W Hour/ 24 Ah @12.8 V of temperature range -10 to +50 C, solar panel capacity 50 Wp, charge controller with dusk dawn sensor having 5250 lumens in 30 Watts with system efficacy not less than 175 Lumens per Watt, complete taking down existing unserviceable light fittings all as directed.Dimmer profile:(a) From dusk - first 4 hours-100% & dimming-25% in non occupancy(b) 2nd 7 hours - 25% (fixed dimming)(c) 3rd 1 hour - 40% & dimming-25% in non occupancy (till dawn conditions)
27Material and labour in replacement for service cable 6 sq mm twin core Weather proof aluminium multistranded conductor cable PVC sheathed PVC insulated round suspended with No.8 SWG GI wire and reel insulators at distance of 01 mtr duly connected with earthing and clamp etc from Pole to pole complete all as specified and directed.
28Description all as per Item No 26 above but 10x2 sq mm complete all as specfied and directed.
29Supply and fixing in replacement thermoplastic polycarbonate IP-65 street light MCB distribution junction box for pole mounting of size 228mm X 126mm X 111mm conforming to IEC 61439-3, shock proof and double insulated, IEC 60529 weather proof, corrosion free, acid and chemical resistant, impact resistant, ultra voilet resistant made out of halogen and silicon free recyclable material, internally embedded gasket with provision for cable entry through top, bottom and sides including impact strength IK 08 in accorance with IEC 62262 to withstand temperature upto 750 degree centrigrade, self extinguishing, fire retardant including MCB SP 6 Amps and suitable size clamps for fixing on pole complete all as specified and directed.
30Supply and fixing in replacement thermoplastic polycarbonate IP-65 street light MCB distribution junction box for pole mounting of size 238mm X 202mm X 111mm conforming to IEC 61439-3, shock proof and double insulated, IEC 60529 weather proof, corrosion free, acid and chemical resistant, impact resistant, ultra voilet resistant made out of halogen and silicon free recyclable material, internally embedded gasket with provision for cable entry through top, bottom and sides including impact strength IK 08 in accorance with IEC 62262 to withstand temperature upto 750 degree centrigrade, self extinguishing, fire retardant including MCB SP 6 Amps and suitable size clamps for fixing complete all as direceted.
31Material and labour for painting to steel pole any type after scrapping and rubbing down with sand paper prepation of old or new surface of poles including pole fitting such as cross arms of any description ,anti climbing devices,nut,bolts etc with two coat of aluminium paint incuding numbering of pole as per existing complete all as directed and making 5 nos of alternative strips of black,yellow paint of 30 Cm wide complete all as specified and directed.
32Dismantling existing steel poles/stuts ,any size carefully for reuse inclding necessary excavation .demolition of concrete etc and removing the old unserviceable poles/rubbish off the premises etc complete all as specified and directed.
33Fixing only of street light poles of any length and dia retrieved against respective dismantling from ser item no 31 above including loading ,shifting ,unloading errection in true vertical position complete all as specified and directed. Note : Excavation and PCC for fixing of pole shall be measured and paid separately.
34Supply and fixing in replacement of steel tubular swaged pole type 410 SP-31, 9 mtr long conforming to IS - 2713 in vertical position, applying two coats of aluminium paint over a coat of red oxide primer externally above ground level and a coat of anti corrosive below ground level a with cast Iron base plate , drilling of holes for cable entering and including taper plug complete all as specified and directed.
35Material and labour for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc size of cutting 100mm wide and 300mm deep and removing the excavated materials and disposal at 50 metre distance and making good to the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as directed.Note:- (a) Cost of GI/ HDPE pipe shall be measured and paid separately under relevant items.
36Supply and laying of XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 16 Sqmm 4.0 core incl lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete, including taking out old u/s cable all as specified and directed. Notes: (a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately.(b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.(c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor.
37Description all as per item No 35 here-in-before but cable of size 10 Sqmm 2 core complete all as specified and directed.
38Description all as per item No 35 here-in-before but cable of size 10 Sqmm 4.0 core complete all as specified and directed.
39Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of electric cableand getting out in any type of soil, complete all as specified and directed
40Returning, filling in excavated soil , including leveling,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
41Removing excavated material(soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above & starting point complete all as specified and directed.
42Material and labour for supply and filling sand with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE: - Punned thickness shall be measurement & paid.
43Material and labour for for sub class 'B' bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as directed.
44Supply & Laying in replacement of GI Steel tubing medium grade 40 mm dia including all fitting laying in trenches across road or grouting /fixing on wall for protection of cable complete all as specified and directed.
45Supply & Laying in replacement of GI Steel tubing medium grade 50 mm dia including all fitting laying in trenches across road or grouting /fixing on wall for protection of cable complete all as specified and directed.
46Material and labour PCC 1:4:8 type C2 (using 40mm graded stone aggregate) as in foundation for Post/Pole/ FPB /Transformer plinth plateform etc including finished even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
47Material and labour PCC 1:2:4 type B-1 (with using 20 mm graded stone aggregate) as in coping of pole/FPB/TFR plinth plateform including necessary form work as required complete as directed.
48Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized wire 4 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 15 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion incl demolition to existing one complete all as specified and directed.Note: (i) Earthing has to done by spl persons and if the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost.(ii) Cost of GI wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item
49Note : Tenderers may note that amount of credit Rs 69868.00 will be deducted from the total amount arrived, at the time of Acceptance of contract. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56467110
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 32 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Street Lights , Security Lights, Solar Lights And Allied Works At Anarwala Under Age E/M -Ii Of Ge Dehradun.
Basic Detail
Tender No 8230/A/E8
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 14 Jul 2026
Submission Date 05 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value 32 Lakhs
Tender Fee 500
EMD 64000
Exemption Available
Document List
56290592-89ec-43eb-8aa2-50d79b715116.html
8230Tenderdocuments.pdf
BOQ_871894.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

56290592-89ec-43eb-8aa2-50d79b715116.html

pdf

8230Tenderdocuments.pdf

xls

BOQ_871894.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders