Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #56467107

Tender For Provision Of New Building/ Assets At Pocket Of A Land To Accommodate Existing Mes Installation Shifiting From Pocket C Land And Pump House With Associated Items For Firefighting Facilities At Icgas Chennai

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
1.65 Crore
Estimated cost
Bid Submission
04 Aug 2026
14 days left
EMD
2.40 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of New Building/ Assets At Pocket Of A Land To Accommodate Existing Mes Installation Shifiting From Pocket C Land And Pump House With Associated Items For Firefighting Facilities At Icgas Chennai

BOQ

Name of Work:- PROVISION OF NEW BUILDING/ ASSETS AT POCKET OF A LAND TO ACCOMMODATE EXISTING MES INSTALLATION SHIFITING FROM POCKET C LAND AND PUMP HOUSE WITH ASSOCIATED ITEMS FOR FIREFIGHTING FACILITIES AT ICGAS CHENNAI
Sl. No. Item Description
1Lumpsum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
2Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-II
3Lumpsum price worked out by the tenderer for ROAD / PATH / CULVERT as listed in Schedule ‘A’ Part-III
4Lumpsum price worked out by the tenderer for ROAD FENCING AND GATE as listed in Schedule ‘A’ Part-IV
5Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-V
6Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VI
7Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VII
8Lumpsum price worked out by the tenderer for FIRE FIGHTING SYSTEM as listed in Schedule ‘A’ Part-VIII
9SCHEDULE 'A' PART IX (MISCELLANEOUS ITEMS)Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under column 5 signifies this fact only.
10COMPOUND WALL, FENCING AND GATE
11Supply and fix 4mm dia GI steel wire PVC coated 75mm x 75mm mesh as in chain link fencing including straining and fixing to posts and to straininig bolts includings securing with and provision of galvanised iron, PVC coated, trying with wire etc., complete all as specified and as directed.
12SEWAGE DISPOSAL
13Material and labour for providing lowering, laying, aligning, testing and commissioning of Precast Reinforced Cement Concrete (RCC) Bio-Septic Tank of active working capacity 10 KL (10,000 Litres) suitable for approximately 130 users, comprising 03 compartments/partitions and complete with 01 No. manhole opening with cover and vent shaft complete as described below and as specified in Particular speciation and as directed by the Engineer-n-Charge :-[i] The tank shall consist of precast/monolithic shell, internal partitions and top slab manufactured using Design Mix Concrete of Grade M40 conforming to IS 456 and reinforced with High Yield Strength Deformed corrosion-resistant TMT bars conforming to IS 1786 (Grade Fe 500D/Fe 550D). [ii] The bio-septic tank shall be designed and manufactured in accordance with DRDO–ABD (Anaerobic Biological Digestion) technology parameters for treatment and disposal of sewage sludge.
14[iii] The work includes excavation in any type of soil, preparation of foundation with sand filling, hard core and 100 mm thick PCC (1:3:6) (M10) bedding, lowering and positioning of the tank using suitable mechanical crane/hoist, sealing all joints with approved high-strength non-shrink waterproof grout, conducting water-tightness test at site and commissioning complete.[iv] The item also includes supply and charging of initial dosage of DRDO-approved Anaerobic Microbial Inoculum (AMI) culture, backfilling around the structure with approved excavated soil in layers not exceeding 200 mm thickness including watering and ramming, brick masonry in cement mortar 1:4 for side wall support, sand filling in balance gaps between tank and wall, and finishing the top surface with hard core, PCC (1:4:8) and PCC (1:2:4), complete in all respects as specified and directed by the Engineer-in-Charge.
15[v] The contractor shall submit a structural stability certificate of bio septic tank duly vetted by IIT Madras (or) NIT Trichy (or) Anna University (or) from any Government Engineering colleges for approval of Bio Septic tank prior to execution.[vi] The contractor shall also submit an extended warranty certificate as specified in Particular Specifications.
16EXTERNAL WATER SUPPLY
17M&L for dismantling of existing Reverse Osmosis (RO) Plant of 500 Ltrs/Hr capacity along with all connected items carefully without any damage including inlet and outlet pipe connections, electrical wiring, starter, foundation bolts, control panel, and associated accessories, at old CG Air Station – MES Pump House Area and shifting to new designated location as directed, re-fixing and replacing the damaged/unserviceable parts, making all connections (water supply, drain, and electrical etc.,) and testing and commissioning complete all as specified and as directed by the Engineer-in-Charge.
18Supply, installation, testing and commissioning of centrifugal monoblock pumping set electric driven of 5 HP capacity all as per Cat No. MHPHET5X00 of Havells Pump or equivalent of other specified make capable of delivering 13.50 LPS at total head of 40 mtr with 80mm suction diameter and 65 mm delivery diameter Head with DOL Starter for 5 HP Motor, fixed on suitable MS frame with necessary PCC foundation etc., complete all as specified and as directed.
19Supply and fix gun metal Check valve 50 mm dia, heavy duty, both end threaded and leaf spring loaded vertical type including taking down unserviceable foot valve / check valve from the suction pipe of the pump set complete all as specified and as directed.
20EXTERNAL ELECTRIC SUPPLY
21Supply, installation, commissioning and testing of LT panel board outdoor type 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 630 Amps capacity Aluminium bus bar for the 3 phase and neutral, both side opening along with locking arrangement,rainguard canopy system, with ventilations fabricated out of steel sections i.e 3.0 mm thick CRCA sheet with angle iron of size 40x40x6mm thick . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. with PCC (1:2:4), Digital multi function meters with necessity CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories:-
22(i) INCOMING:- ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 630 Amps - 01 No.(ii) OUTGOING:-(a) MCCB 4 Pole, 415 V, Adjustable type, 400 Amps, 36 KA - 02 Nos.(b) MCCB 4 Pole, 415 V, Adjustable type, 350 Amps, 36 KA - 03 Nos.(c) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps ,36 KA - 01 Nos.(d) MCCB 3 Pole, 100 Amp,with Fixed TM,415 volt, 16 KA - 01 Nos.(e) MCCB 3 Pole, 63 Amp,with Fixed TM,415 volt, 16 KA - 01 Nos. (iii) Indicator Lamp Set of 03 - 01 No
23Supply, installation, commissioning and testing of LT panel board outdoor type 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 630 Amps capacity Aluminium bus bar for the 3 phase and neutral, both side opening along with locking arrangement,rainguard canopy system, with ventilations fabricated out of steel sections i.e 3.0 mm thick CRCA sheet with angle iron of size 40x40x6mm thick . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. with PCC (1:2:4), Digital multi function meters with necessity CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories :- (LT panel for DG Set).
24(i) INCOMING:-MCCB 4 Pole, 415 V, Adjustable type, 350 Amps, 36 KA - 02 Nos.(ii) Automatic Transfer Switch 4 Pole, 415 V, 315 Amps Auto/Manual with complete protection -01 Nos.(iii) OUTGOING:-(a) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps, 36 KA - 01 No.(b) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps, 36 KA - 01 No.(c) MCCB 3 Pole, 125 Amp,with Fixed TM,415 volt, 16 KA - 01 No.(d) MCCB 3 Pole, 25 to 100 Amp,with Fixed TM,415 volt, 16 KA - 03 Nos.(iv) Indicator Lamp Set of 03 - 01 No
25Supply, installation, commissioning and testing of LT Feeder pillar box outdoor type 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 630 Amps capacity Aluminium bus bar for the 3 phase and neutral, both side opening along with locking arrangement,rainguard canopy system, with ventilations fabricated out of steel sections i.e 3.0 mm thick CRCA sheet with angle iron of size 40x40x6mm thick . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. with PCC (1:2:4), Digital multi function meters with necessity CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories for Genset Feeder Near crew room :-
26(i) INCOMING:- MCCB 4 Pole, 415 V, Adjustable type, 350 Amps, 36 KA - 01 No.(ii) OUTGOING:-(a) MCCB 3 Pole, 125 Amp,with Fixed TM,415 volt, 16 KA - 02 Nos.(b) MCCB 3 Pole, 25 to 100 Amp,with Fixed TM,415 volt, 16 KA - 02 Nos.(iii) Indicator Lamp Set of 03 - 01 No.
27Supply, installation, commissioning and testing of LT Feeder pillar box outdoor type 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 630 Amps capacity Aluminium bus bar for the 3 phase and neutral, both side opening along with locking arrangement,rainguard canopy system, with ventilations fabricated out of steel sections i.e 3.0 mm thick CRCA sheet with angle iron of size 40x40x6mm thick . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. with PCC (1:2:4), Digital multi function meters with necessity CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories for Utility Feeder Near crew room :-
28(i) INCOMING:- MCCB 4 Pole, 415 V, Adjustable type, 350 Amps, 36 KA - 01 No.(ii) OUTGOING:-(a) MCCB 3 Pole, 125 Amp,with Fixed TM,415 volt, 16 KA - 02 Nos.(b) MCCB 3 Pole, 25 to 100 Amp,with Fixed TM,415 volt, 16 KA - 04 Nos.(iii) Indicator Lamp Set of 03 - 01 No. Please Enable Macros to View BoQ information
29(i) INCOMING:- MCCB 4 Pole, 415 V, Adjustable type, 350 Amps, 36 KA - 01 No.(ii) OUTGOING:-(a) MCCB 3 Pole, 125 Amp,with Fixed TM,415 volt, 16 KA - 02 Nos.(b) MCCB 3 Pole, 25 to 100 Amp,with Fixed TM,415 volt, 16 KA - 04 Nos.(iii) Indicator Lamp Set of 03 - 01 No. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56467107
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.65 Crore
LAST DATE 04-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of New Building/ Assets At Pocket Of A Land To Accommodate Existing Mes Installation Shifiting From Pocket C Land And Pump House With Associated Items For Firefighting Facilities At Icgas Chennai
Basic Detail
Tender No 8297/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 14 Jul 2026
Submission Date 04 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 1.65 Crore
Tender Fee 1000
EMD 2.40 Lakhs
Exemption Available
Document List
4fe8a8bb-3482-4cb7-a87c-15a2acd24bab.html
8297TENDER.pdf
ArchStructuralDrgs.pdf
BOQ_871983.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

4fe8a8bb-3482-4cb7-a87c-15a2acd24bab.html

pdf

8297TENDER.pdf

pdf

ArchStructuralDrgs.pdf

xls

BOQ_871983.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders