Tender For Provn Of Lighting In Inspection Galley At Shivsagar Dam At installation Shivaji ,Lonavla (8469/E8)
Tender Value
23.78 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
21 days left
EMD
47600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Lighting In Inspection Galley At Shivsagar Dam At installation Shivaji ,Lonavla (8469/E8)
BOQ
| Sl. No. | Item Description |
| 1 | S&F of vertical type DB , (VTPN) suitable for and including MCCB 4 pole, 100 amps, 16KA as incoming (compact) Earth and neutral bus bar of capacity upto 250 amp 4 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed. |
| 2 | S&F of MCB SP 5 To 32 AMP, single pole 240 Volts 10KA ''C'' curve as per site requirment,Complete all as specified and directed. |
| 3 | S&F of MCB TP 40 T0 63 AMP, 415 Volts 10KA ''C'' curve as per site requirment,Complete all as specified and directed. |
| 4 | Supply & fix of 20 Watt LED, surface mounted, IP65 weatherproof batten for single T8 LED tube, robust lighting fixture designed to withstand harsh environment with square profile and polycarbonate channel. mounted on square box of suitable size connecting up with three core flexible copper conductor cable of suitable size from ceiling rose/junction box complete with all connected accessories and jointing materials. Make:- Crompton CIS-307-20-CP-NGR or equivalent to Surya/Philips/Havells |
| 5 | Supply & fix of LED street light of 70 watt along with cast aluminium housing,toughened glass diffuser,secondary optics,IP65/66,10 KV SPD,>100lm/watt and wired with accessories complete all as specified and directed.Make:Crompton CPP-421-70-57-SL-LM-NSG or equivalent to Surya/Philips/Havells |
| 6 | S & F LED decorative column light 50 watts with die cast aluminium pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage and IP65 protection with tricolor and tratic white output switch, 3.0 mtr hight all as specified and directed. Cat No- Bajaj BLSLC 50W LED TRI 3M or equivalent philips/bajaj/havells |
| 7 | S & F LED Bollard,with opal, 9 watts, cast aluminium housing & polymer diffuser for pleasant light output,weather proof.IP65 complete with LED,inbuilt driver & wired with all accessories. Make:- Bajaj BGBOM 1000 9W LED WH or equivalent philips/bajaj/havells |
| 8 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core all as specified and directed. |
| 9 | S&F cable flexible PVC insulated three core with copper conductor of size 1.5 sqmm all as specified and directed. |
| 10 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core on wall/roof/ or in cable tray with necessary clamps/hooks etc all as specified and directed. |
| 11 | S & F XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 25 sqmm 4 core on wall/roof/ or in cable tray with necessary clamps/hooks etc all as specified and directed. |
| 12 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3½ core on wall/roof/ or in cable tray with necessary clamps/hooks etc all as specified and directed. |
| 13 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3½ core coreon wall/roof/under ground or in cable tray with necessary clamps/hooks etc all as specified and directed. |
| 14 | Supply, installation of GRP covered weatherproof cable tray, rectangle shape, corrosion resistant, 300 x 50 mm, 6 mm thickness, powder coated/galvanised surface finish complete with all necessory fittings/fixtures such as bends,tees, joints, screwes, hooks, clamps etc all as specified and directed. |
| 15 | S & F Thermoplastic Cable Junction Boxes IP 66/69 “weather proof”, for indoor/outdoor installation (with knockouts for cable entry - Black colour ) , size 130x 180x 77 mm with terminals, suitable mounting clamp all as specified and directed.Make : Hensel KF-1010 B or equivalent |
| 16 | Supply and lay in trenches / along the wall / floor flexible conduit weatherproof of size 25 mm dia with and including all fittings and accessories complete all as specified and and directed for cable protection |
| 17 | Supply and lay in trenches / along the wall / floor pipes GI light grade of size 50 mm dia with and including all fittings and accessories including taking down old U/S pipe complete all as specified and and directed for cable protection |
| 18 | M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamber all as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed. |
| 19 | Supply, installation, testing and commissioning Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 20 | Supply and lay in trenches / along the wall / floor DWC (Double wall corrugated) pipes of size 50 x 38 mm dia with and including all fittings and accessories for laying of LT cables complete all as specified and and directed for cable protection |
| 21 | Supply, fabricating and fixing, in replacement of, powder coated MS busbar chamber of minimum size of 900 x 600 x 300 mm, made out of CRCA MS Sheet 2 mm thick, front openable with locking arrangement, double door type, duly provided with aluminium bus bar of size 50 x 6 mm colour coded with heat shrinkable PVC sleeves for phases and neutral, fixed on SMC/DMC insulator, weather/vermin proof duly provided with PU gasket alond the door, fixed on 50x50x6mm angle iron 4 leg frame duly grouted in P:C:C (1:2:4) (Each leg 50cm grouted in ground/floor and 50cm above floor level, with and including one no of incomer MCCB 160 Amps, 36 kA, 3 pole, thermal magnetic release, ICS = 100% ICU with and including Spreader Terminals, including making connection complete all as specified and directed.Note for Item No 1 to 21 :-(a) As the work to be carried out in inspection gallery of Dam, requires strict adherence to safety protocols due to the confined space, high humidity and proximity to massive water pressure. Essential precautions include rigorous confined space entry procedures, maintaining adequate ventillation, wearing specialized personal protective equipments and ensuring robust emergency communication systems.(b) Work should be carried out through specialised trained skilled, experienced, medically fit workers.(c ) All necessary safety equipments required during the working in gallery like hard hats, non slip safety footwear, high visibillity vests, oxygen cylender with mask etc should be provided to the workers.(d) Reliable intrinsically safe two way radio or hand signal systems must be established between the workers inside the gallery and the dedicated standby attentants outside, Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysAug 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer