Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Electrical System Or Installation; Service Provider - Supplying And Laying Of One Number Of Size 3.5 Core X 25 Sq Mm Pvc Insulated An
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Electrical System Or Installation; Service Provider - Supplying And Laying Of One Number Of Size 3.5 Core X 25 Sq Mm Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Armoured Power Cable Of 1.1 Grade In Following Manner As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , Supplying And Laying/Fixing Of Pvc Insulated & Pvc Sheathed Lt 5 Core 1.1Kv Grade Ariel Bunched Cable (Abs)With Xlpe Insulation Of Size 25 Sqmm, Confirming To Is 14255:1995 Suitable For Arieal Service Connection In Following Manner (Cable Shall Consist Of 4 Cores X 25 Sq Mm, 1 X 16 Sq Mm As Insulated Messanger Cum Neutral) , S/F Accessories For Lt 5 Core 1.1Kv Grade Ariel Bunched Cable Of Size 25 Sq Mm I/C Making Connections , Testing Etc Complete As Required. , Providing And Fixing/ Laying 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing / Supporting Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required , Supplying And Fixing Bescom/Hescom Approved Fuse Cut-Out Having 3 Nos ,63 S Nos Kit-Kat Fuses & Neutral Link With Suitable Capacity Fuse Wire-Links Fitted On Hylum Sheet With Required Fixing Hardware Suitable For Fixing On Keb Rcc/Cement Pole Etc.Complete As Required. , Carrying Out Preventive Maintenance Of Electrical Infra Including Tightning Of Power Cable Connection & Cable Connections In The Kit-Kat Fuses On Hescom Pole , Checking For Burnt / Heated Terminals And Attending Faults By Replacing Burnt Terminal With Suitable Rating Of Lugs, Cleaning Of Sdb/Panel In Bts Hut/Room Including Cleaning With Blower,Tightning Of All Contacts,Checking For Of Burnt / Heated Terminals And Attending Faults By Replacing Burnt Terminal With Suitable Rating Of Lugs , Etc Complete As Required. (Note- This Item Does Not Include Any Major Electrical Item If Found Faulty. The Same Shall Be Paid At Extra Cost) , Supplying And Laying 40 Mm Dia Class-A Gi Pipe As Per Following Etc Complete As Required.(Isi Marked). , Supplying And Laying Of 40 Mm Dia Hdpe Of 6 Kg Per Square Cm In Following Ways For Drawing Ug Cable E As Required. , Supplying And Making Straight Through Joint With Cast Resin Compound Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required , Reduction/Enhancement Of Existing Hescom Contract Demand I/C Submission Of Application To Hescom,Puersuation With Various Hescom Offices, Obtaining O & M For Load Enhancement , Testing Of Meter From Mrt Division Of Respective Hescom Area, , I/C Co-Ordination With Hescom Field Units, Taking Shut Down,Making Payment Of Testing Fees , Shut Down Charges Etc Complete As Required.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supplying and laying of one number of size 3.5 core x 25 sq mm PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 grade in following manner as required. | Supplying and laying of one number of size 3.5 core x 25 sq mm PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 grade in following manner as required. |
| 2 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 3 | Supplying and laying/fixing of PVC insulated & PVC sheathed LT 5 core 1.1KV grade Ariel bunched cable (ABS)with XLPE insulation of size 25 Sqmm, confirming to IS 14255:1995 suitable for arieal service connection in following manner (Cable shall consist of 4 cores x 25 sq mm, 1 x 16 sq mm as insulated messanger cum neutral) | Supplying and laying/fixing of PVC insulated & PVC sheathed LT 5 core 1.1KV grade Ariel bunched cable (ABS)with XLPE insulation of size 25 Sqmm, confirming to IS 14255:1995 suitable for arieal service connection in following manner (Cable shall consist of 4 cores x 25 sq mm, 1 x 16 sq mm as insulated messanger cum neutral) |
| 4 | S/F accessories for LT 5 core 1.1KV grade Ariel bunched cable of size 25 Sq mm i/c making connections , testing etc complete as required. | S/F accessories for LT 5 core 1.1KV grade Ariel bunched cable of size 25 Sq mm i/c making connections , testing etc complete as required. |
| 5 | Providing and fixing/ Laying 6 SWG dia G.I. wire on surface or in recess for loop earthing / supporting along with existing surface/ recessed conduit/ submain wiring/ cable as required | Providing and fixing/ Laying 6 SWG dia G.I. wire on surface or in recess for loop earthing / supporting along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 6 | Supplying and fixing BESCOM/HESCOM approved fuse cut-out having 3 Nos ,63 Amps nos kit-kat fuses & neutral link with suitable capacity fuse wire-links fitted on Hylum sheet with required fixing hardware suitable for fixing on KEB RCC/cement pole etc.complete as required. | Supplying and fixing BESCOM/HESCOM approved fuse cut-out having 3 Nos ,63 Amps nos kit-kat fuses & neutral link with suitable capacity fuse wire-links fitted on Hylum sheet with required fixing hardware suitable for fixing on KEB RCC/cement pole etc.complete as required. |
| 7 | Carrying out preventive maintenance of Electrical infra including tightning of power cable connection & cable connections in the Kit-kat fuses on HESCOM pole , checking for burnt / heated terminals and attending faults by replacing burnt terminal with suitable rating of lugs, cleaning of SDB/Panel in BTS hut/room including cleaning with blower,tightning of all contacts,checking for of burnt / heated terminals and attending faults by replacing burnt terminal with suitable rating of lugs , etc complete as required. (Note- This item does not include any major electrical item if found faulty. The same shall be paid at extra cost) | Carrying out preventive maintenance of Electrical infra including tightning of power cable connection & cable connections in the Kit-kat fuses on HESCOM pole , checking for burnt / heated terminals and attending faults by replacing burnt terminal with suitable rating of lugs, cleaning of SDB/Panel in BTS hut/room including cleaning with blower,tightning of all contacts,checking for of burnt / heated terminals and attending faults by replacing burnt terminal with suitable rating of lugs , etc complete as required. (Note- This item does not include any major electrical item if found faulty. The same shall be paid at extra cost) |
| 8 | Supplying and laying 40 mm dia class-A GI pipe as per following etc complete as required.(ISI Marked). | Supplying and laying 40 mm dia class-A GI pipe as per following etc complete as required.(ISI Marked). |
| 9 | Supplying and laying of 40 mm dia HDPE of 6 Kg per square cm in following ways for drawing UG cable e as required. | Supplying and laying of 40 mm dia HDPE of 6 Kg per square cm in following ways for drawing UG cable e as required. |
| 10 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
| 11 | Reduction/Enhancement of existing HESCOM contract demand i/c submission of application to HESCOM,puersuation with various HESCOM offices, obtaining O & M for load enhancement , testing of meter from MRT division of respective HESCOM area, , i/c co-ordination with HESCOM field units, taking shut down,making payment of testing fees , shut down charges etc complete as required. | Reduction/Enhancement of existing HESCOM contract demand i/c submission of application to HESCOM,puersuation with various HESCOM offices, obtaining O & M for load enhancement , testing of meter from MRT division of respective HESCOM area, , i/c co-ordination with HESCOM field units, taking shut down,making payment of testing fees , shut down charges etc complete as required. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender