Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56457372

Tender For Provision Of Voltage Stabilizer With Isolation Transformer For Critical It Infrastructure At Hemrl

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Aug 2026
20 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Voltage Stabilizer With Isolation Transformer For Critical It Infrastructure At Hemrl

BOQ

Name of Work:- PROVISION OF VOLTAGE STABILIZER WITH ISOLATION TRANSFORMER FOR CRITICAL IT INFRASTRUCTURE AT HEMRL
Sl. No. Item Description
1Excavating holes in all kinds of soil more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc. disposing of surplus excavated soild, as directed within a lead of 50 m and lift upto 1.5 m. complete all as specified and directed.
2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 type B1 (using 20 mm graded stone aggregated) complete all as specified and directed.
3Material and labour for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 applying a priming coat of approved steel primer Complete all as specified and as directed by Engineer-in-Charge.
4Material and labour for Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as specified and directed.
5Supply and fix Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
6Material and labour for Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications for Painting of Steel work with Deluxe Multi Surface Paint to give an even shade. Two coats applied @ 0.90 ltr/ 10 sqm over and under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture complete all as specified and directed.
7Earth work in excavation for all kind of soil, by mechanical means (hydraulic excavation) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m complete all as specified and directed by Engineer-in-charge.
8Excavation work for ordinary rock by mechanical means (Hydraulic excavator) / manual means in foundation means in foundation trenches or drains (not exceeding 1.5m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Ordinary rock complete all as specified and directed by Engineer-in-charge.
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) complete all as specified and directed.
10Material and labour for Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed.
11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m complete all as specified and directed.
12Supplying and fixing for PVC (SWR) pipes 110mm dia in any length for deep holes complete all as specified and directed.
13Material and labour for extra over stone walling for hammer dressing to face stones and dressing or face beds and joints as directed of random rubble walling, uncoursed or brought upto courses 20mm deep in granite or trap stone complete all as specified and directed.
14Material and labour for keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in CM (1:3) complete all as specified and as directed.
15Providing and laying cement concrete in retaining walls, return walls, walls (any thicknes) including attached pilasters, columns, piers, abutments, pillars, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. upto floor five level, excluding the cost of centering, shuttering and finishing 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size) complete all as specified and directed.
16Material and labour for rendering 12mm thick cement plaster of mix cement mortar 1:4 complete all as specified and directed.
17Supply and fix at site Angle iron post strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete all as specified and as directed.
18Supply and fixing for steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar work complete all as specified and directed.
19Providing and fixing GI chain link madeup with wire of 4mm dia fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete all as specified and directed.
20Material and labour for finishing walls with Acrylic smooth exterior paint of required shade for new work in two coat applied @ 1.67 ltr/10Sqm over and including primming coat of exterior primer applied @ 2.20Kg/10Sqm of approved brand and manufacture complete all as specified and directed.
21Material and labour for finishing with deluxe Multi surface paint system for interiors and exteriors for painting of steel work with deluxe multi surface paint to give an even shade. Two coat applied @ 0.90 ltr/10Sqm over an under cate of pimer applied @ 0.80ltr/10Sqm of approved brand and manufacture complete all as specified and directed.
22Supply and fix Servo Voltage Stabilizer for automatic operation A+ grade, three phase pure copper winding with high low voltage cut off bypass switch and all other standard accessories, microprocessor based suitable for fast fluctuation if occurs in input side, voltage range 300-480 volts, naturally oil cooled, indoor type, output voltage stabilized at 415 with accuracy ±2.5% and speed of correction 8 Volts per second and of capacity 300 KVA with first fill of transformer oil (confirming to IS 335) of required quantity. Stabilizer must meet the following specification :(a) Servo Controlled Voltage Stabilizer. (b) Natural Oil Cooled. (c) Three phase 4 wires. (d) Input voltage range 300-480 Volts (e) Operation voltage range 170-280 Volts. (f) Output voltage - 415 Volts AC 3 phase. (g) Single phase output 220 Volts AC. (h) Output Accuracy +/-2.5%. (j) Frequency = 50 Hz +/-3Hz. (k) Duty Cycle - continuous 24x7 operation. (l) Efficiency- >98%.(m) Construction features : Winding material -100% copper, transformer type - Buck Boost transformer, core material - CRGO laminatino , insulation class - Class - H, Tank material - Heavy duty MS tank, cooling medium - Transformer oil.(n) Protection Features : High and low voltage protection, overload protection, short circuit protection, phase failure protection, single pahse protection, bypass switch facility.(o) Metering Facility : Digital LCD display, input and output voltage indication, load current indication, frequency indication, phase healthy indication, faul indication lamp.
23Supply, installation, testing and commissioning, isolation transformer 300 KVA, 415 Volts (Fixed ration), 3 phase, 50 Hz, ONAN cooled oil immersed copper wound, indoor type, complete with first filling of IS-335 ISI marked filtered and dehydrated transformer oil electrostatic shield between primary 415 Volts in Delta connection and secondary 415 volts in Star connection complete with all necessary standard fittings / accessories with Vector Group Dy-11 complete all as specified and directed, isolation transformer must meet the following technical specification and standard fittings & accessories:-Technical Specifications:-(a) Rating in KVA - 300 KVA, Indoor(b) Voltage ratio _ 415/415 Volts(c) Frequency - 50 Hz(d) Winding - Electrolytic Grade, Copper Double Wound(e) Connection primary / secondary - Delta/Star(f) Vector Group - Dyn 11(g) Cooling type - ONAN(h) Ambient temperature - 50 degree celcius(j) Temp rise above ambient (Oil/Winding) - 50/55 degree celcius(k) Tap switch - Off circuit tap switch(l) Terminals - Primary and secondary both side cable box(m) Insulation - Class AStandard Fittings & Accessories :-(n) Off circuit tap switch, lifting lugs, top cover lugs, earthing terminals, conservator with oil gauge glass, oil filling hole with plug and drain plug, Transformer drain valve, Bi directional plain roller, explosion vent with diaphragm. Termometer pocket, Air vent plug, silica gel breather, rating & digram plate, inspection cover terminal marking plate, cooling radiators, LV neutral bushing brought out for external earthing and first fill of EHV grade transformer oil as per IS 335 grade.
24Supply, Laying and testing cable XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured, electric power cables ( heavy duty) 1100V grade with stranded alluminium conductor of size 300 sqmm 3.5 Core complete all as specified and as directed.
25Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for taking out/laying of LT under ground cable and getting out in the soft earth strata complete all as specified and as directed.
26Supply and laying un-reinforced precast concrete cable cover class HV, Type I, flat, size 250mm x150mm x 40mm for cable protection all as specified and directed by the Engr-in-Charge.
27Supplying, spreading, leveling and well ramming in layers not exceeding 20 cm in height stone crushed sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge.
28Material and labour for returning/filling available excavated earth (excluding rock) in trenches, sides of foundations etc in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m complete all as specified and directed.
29Removing excavated materials not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
30Material and labour for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised earth lead strip 25mm x 5 mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 05 of SSR Part I connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber RCC 1:2:4 type B1 in cover slab GI funnel with GI watering pipe 20 mm bore med gde, wire mesh, protection pipe 20 mm bore GI pipe light gde for earth lead upto 7.50 m long including testing complete all as specified and directed by Engineer-in-Charge.
31Supply and fixing 25mm x 5mm GI strip on surface or in recess for connections etc as required at site complte all as specified and directed.
32Supply, install test and commissioning of Outdoor LT Bus bar Feeder Pillar Enclosure CPRI approved cubical made of 3 mm thick with IP 54 grade of protection CRCA sheet, powder coated of size 1420mm x 1470mm x 600mm with support of 50mm x 50mm x 6mm angle iron bottom frame with double hinged front and rear openable with locking arrangement, heat shrinkable PVC sleeved aluminium bus bar of size 40 x 10mm (2runs each), 3 phase and Neutral, fixed on suitable insulator all housed in suitable bus bar chamber and provision and fixing of pilot indication lamps (R, Y & B) complete alongwith provision for necessary cable entry/exit from bottom and all incoming and putgoing cables with suitable glands etc fixed on suitable PCC foundation complete, testing and commissioning on completion all as specified and directed and shall comprises of MCCB 630 Amps, 4 pole, 50KA adjustable with thermal magnetic release complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56457372
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 04-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Voltage Stabilizer With Isolation Transformer For Critical It Infrastructure At Hemrl
Basic Detail
Tender No GERD/PSN/TOKEN/38 OF 2026-27
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 14 Jul 2026
Submission Date 04 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 94000
Exemption Available
Document List
59d820d9-37d3-4afd-835a-a936ef958a8b.html
8732.pdf
BOQ_871879.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
html

59d820d9-37d3-4afd-835a-a936ef958a8b.html

pdf

8732.pdf

xls

BOQ_871879.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders