Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56457365

Tender For Repair/Maint Of Overhead Cranes, Misc Machinery, Dg Sets And Lighting Protection System Including Connected Works At 15 Fad Jindrah Under Ge (Army) Dhar Road Udh Ur

Issued by Statutory Bodies & Commissions/Committees · Reasi, Jammu and Kashmir
Tender Value
44.80 Lakhs
Estimated cost
Bid Submission
04 Aug 2026
18 days left
EMD
89600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Overhead Cranes, Misc Machinery, Dg Sets And Lighting Protection System Including Connected Works At 15 Fad Jindrah Under Ge (Army) Dhar Road Udh Ur

BOQ

Name of Work:- REPAIR/MAINT OF OVERHEAD CRANES, MISC MACHINERY, DG SETS AND LIGHTING PROTECTION SYSTEM INCLUDING CONNECTED WORKS AT 15 FAD JINDRAH UNDER GE (ARMY) DHAR ROAD UDH UR
Sl. No. Item Description
1BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: REPAIR/MAINT OF OVERHEAD CRANES, MISC MACHINERY, DG SETS AND LIGHTING PROTECTION SYSTEM INCLUDING CONNECTED WORKS AT 15 FAD JINDRAH UNDER GE (ARMY) DHAR ROAD UDHAMPUR Contract No: CWE/U(DR)-52/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2Repair, comprehensive and preventive maintenance of DG set any make of the following capacities which include taking down diesel filter,Engine oil filter ,lubricating oil rubber hose pipe ,V belt oil pipe,fuel pipe and other burn spare parts etc and tightning of nuts bolt, washers greasing etc for proper running of DG set of capacity 62.5KVA .
3Ditto all as per item No.1 above but capacity of DG Set 125KVA
4Ditto all as per item No.1 above but capacity of DG Set 160KVA complete all as specified and as directed.
5Ditto all as per item No.1 above but capacity of DE Pump 10HP complete all as specified and as directed.
6Ditto all as per item No.1 above but capacity of DE Pump 50HP complete all as specified and as directed.
7M&L for dismantling /opening of alternator of DG Set by disconnection of cable connections and flexible coupling, nuts/bolts and alternator foundation nut, bolts including opening of earth strip opening of alternator and checking out burnt out Winding of DG Sets of capacity 125KVA to 160 KVA and taken back in temporary platform all as specified and directed.
8All as per Sr item No. 06 above but DG Sets of capacity 62.5 KVA complete all as specified and as directed.
9Taking out burnt armature, winding wire and rewinding of armature with super enamelled copper winding wire of existing gauge including insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature for 62.5KVA to 160 KVA set wire DG sets.
10Taking out burnt field coil and rewinding of field coil with super enamelled copper winding wire of existing gauge including insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature for 62.5KVA to 160 KVA sets.
11M&L for insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature for 125 KVA to 160 KVA DG Sets.
12All as per Sr item No.10 above but DG Sets of capacity 62.5 KVA Complete all as specified and as directed.
13M&L for insulation of field coils with Class ‘B’ insulation and varnishing of field coils and drying up to desired temperature for 125KVA to 160 KVA Alternator of DG Sets.
14Re-assembling of rotor and stator after rewinding and re-fixing of Alternator with Engine by assembling flexible coupling with alternator mounting with nuts, bolts including making cable connection complete including testing and commissioning at desire load of DG Set of capacity 125KVA to 160KVA complete all as specified and directed.
15All as per Sr item No. 13 above but DG Sets of capacity 62.5KVA complete all as specified and as directed.
16Dismantling of radiator and repair by welding/soldering of radiator fins and re-fixing the same after de-scaling and brazing and cleaning of radiator with caustic soda and hydrochloric acid including replacement of radiator foundation nuts, bolts (where ever required) complete all as specified and directed.
17M&L for Over hauling Fuel injector pump from DG set carefully, transprotation of the same to civil work-shop for repair & complete service of FIP pump and calibration on automatic setting machine, shifting of FIP pump from civil work-shop to worksite and re-fixing the same to DG set and testing complete capacity 160KVA complete all as specified and directed.
18M&L for Over hauling Fuel injector pump from DG set carefully, transprotation of the same to civil work-shop for repair & complete service of FIP pump and calibration on automatic setting machine, shifting of FIP pump from civil work-shop to worksite and re-fixing the same to DG set and testing complete capacity 125KVA. complete all as specified and directed.
19M&L for Over hauling Fuel injector pump from DG set carefully, transprotation of the same to civil work-shop for repair & complete service of FIP pump and calibration on automatic setting machine, shifting of FIP pump from civil work-shop to worksite and re-fixing the same to DG set and testing complete capacity 62.5 KVA complete all as specified and directed.
20Dismantling / Taking down the 160 KVA DG Set (Eninge and Alternator ) assembly / parts for carrying out / replacement of following spare parts at site and re-assembling the DG Set after repair and testing complete. Spare parts replaced shall be measured and paids as Supply & fixing in replacement of under following items :-
21S& F in replacment of Piston Ring.set of existing type and make complete all as specified and directed.
22S& F in replacment of Cylinder liner with joints rings of existing type and make complete all as specified and directed.
23S& F in replacment of valve cylinder head assly of existing type and make complete all as specified and directed.
24S& F in replacment of valve seat insert (inlet) of existing type and make complete all as specified and directed.
25S& F in replacment of valve Guide Cyl head of existing type and make complete all as specified and directed.
26S& F in replacment of Valve collet (3-grove)lock of existing type and make complete all as specified and directed.
27S& F in replacment of Cylinder head gasket of existing type and make complete all as specified and directed.
28S& F in replacment of Sets of Jointst(Engine Gasket set complete) of existing type and make complete all as specified and directed.
29S& F in replacment of Crank oil seal front of existing type and make complete all as specified and directed.
30S& F in replacment of Crank oil seal rear of existing type and make complete all as specified and directed.
31S& F in replacment of Thrust washer of existing type and make complete all as specified and directed.
32S& F in replacment of connecting rod bearing(cell) of existing type and make complete all as specified and directed.
33S& F in replacment of Main general bearing(cell) of existing type and make complete all as specified and directed.
34S& F in replacment of Connecting rod bush of existing type and make complete all as specified and directed.
35Supply & fixing in replacement of Controller/ PCB with (± / - 15V,DC) out put for hall effect sensor of existing type and make complete all as directed.
36S& F in replacment of V belt /Grooved complete set for the capacity of DG Sets 62.5 KVA to 160 KVA approved make for the DG set existing type and make complete all as specified and directed.
37Servicing of DG Set draing out used Engine oil of DG Set and cleaning sump completely with re-filling of engine oil 15 W 40 in sealed drum after taking out un-serviceable engine oil from oil sump (Note- Oil 15W40 shall be measured and paid separetely.
38M&L in replacement for Kirloskar Oil of grade 15W - 40 or as specified by manufacturer for topping up or replacement of lubricating oils during different checks complete all as specified and as directed.
39M&L in replacement for Lubricating oil filter suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
40M&L in replacement for Fuel filter element primary suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
41M&L in replacement for Fuel filter element secondary suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
42M&L in replacement for Seal ring for fuel filter suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
43M&L in replacement for Air Cleaner Primary Element suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
44M&L in replacement for Air Cleaner Safety Element for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
45M&L in replacement for coolant premixer for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
46Supply & fixing in replacement of Magnetic pickup unit suitable for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
47M&L in replacement for Hose Rubber: Engine to Radiator for 62.5 KVA to 160 KVA DG Sets all as specified and directed.
48M&L in replacement for Hose Rubber: Radiator to Engine for 62.5KVA to 160 KVA DG Sets all as specified and directed.
49Suppy & Fixing in replacement of battery terminal of batteries of capacity upto 12 Volt ,150/180 Ah.inculding nuts and bolts of DG set capacity 125KVA to 160KVA complete all as specified and directed.
50Suppy & Fixing in replacement of Hose TC Drain for 62. 5KVA to 160 KVA DG Sets all as specified and directed.
51S&F in replacement of Clamp Hose Bend Type for 62. 5KVA to 160 KVA DG Sets all as specified and directed.
52Suppy & Fixing in replacement of Seal Oil (Front) for 62.5KVA to 160 KVA DG all as specified and directed.
53Supply in fixing in replacement of self starter suitable for 62.5KVA to 160 KVA DG Sets complete all as specified and directed.
54Suppy & Fixing in replacement of AVR unit suitable for 62.5KVA to 160 KVA DG Sets as prescribed by the manufacturer.
55Suppy & Fixing in replacement of Charging Alternator 12 V , 3R suitable for 62.5 KVA to 125 KVA DG SET and removing of unserviceable Charging Alternator 12 V complete all as specified and directed.
56Suppy & Fixing in replacement of Charging Alternator 24 V , 3R suitable for 62.5 KVA to 125 KVA DG SET and removing of unserviceable Charging Alternator 24 V complete all as specified and directed.
57Supply & fixing in replacement of Instrument Panel, 3R unit suitable for 62.5 KVA to 125 KVA as prescribed by the manufacturer.
58Supply & fixing in replacement of Stop Solenoid 3R unit suitable for 62.5 KVA to 125 KVA as prescribed by the manufacturer.
59Supply & fixing in replacement of Engine Control Panel, 3R unit suitable for 62.5 KVA to 125KVA as prescribed by the manufacturer.
60Supply & fixing in replacement of Engine Control Unit EMS907, 3R unit suitable for 62.5 KVA to 125 KVA as prescribed by the manufacturer.
61Supply & fixing in replacement of Start Stop card RB electronics of existing type and make complete all as specified and directed.
62Supply & fixing in replacement of Fuel Pipe for filter (pre- filter to take unit). of existing type and make complete all as specified and directed.
63Supply & fixing in replacement of Fuel return pipe of existing type and make complete all as specified and directed.
64Supply & fixing in replacement of 1.1 Ltr Duel Fuel filter w/o over flow valve. of existing type and make complete all as specified and directed.
65Supply & fixing in replacement of Silencer suitable DG Set for capacity 125KVA to 160KVA of existing type and make complete all as specified and directed.
66Supply & fixing in replacement of Silencer suitable DG Set for capacity 62.5KVA of existing type cand make complete all as specified and directed.
67Supply & fixing in replacement of Oil pump assly of existing type and make complete all as specified and directed.
68Supply & fixing in replacement of Piston assembly of existing type and make complete all as specified and directed.
69Supply & fixing in replacement of Harness,wiring engine of existing type and make complete all as specified and directed.
70Dismantling and taking out of broken shaft from DE Pump 50 HP and replacement of new shaft , lath work including required no of bush complete all as directed.
71S&F in replacement of Off load side handle change over switch 200 Amps, 4 pole, 415 volts with sheet metal enclosure complete all as directed.
72S&F in replacement of Onload side handle change over switch 100 Amps, 4 pole, 415 volts with sheet metal enclosure complete all as directed.
73M&L for writing SM No. /MES No. /Maker No/Make /Capacity with letter of required siize i.e hight and thickness of letter on machine /plant at site deploying 'sign writer' complete all as specified & directed.
74Shifting of DG Set any capacity any size at one place to another place by removing all connections of Alternator and panel with help of skilled electrician and labour, pull up the DG Set with the help of crane and fix the DG Set at plinth of RCC with the help of crane and connections of panel and alternator and testing of DG Set at load after re-shifiting all as specified and directed by Engr-in - Charge.
75S&F in replacement of Digital / S96 Voltmeter range 0-500 Volts, AC,Ammeter range 300Amp with complete panel wiring.
76M&L for rubbing the uneven as well as open surface of DG set of capacity ranging from 62.5KVA to 160 KVA with emery paper, cleaning all the grease and oil substances over the area. applying two coat of synthetic enamelled paint as per existing colour code or as directed.
77S&F in replacement battery 12 volt, 180Ah complete all as specified and directed.
78S&F in replacement battery 12 volt, 150Ah complete all as specified and directed.
79S&F in replacement of MCCB 125 Amps 4 Pole, 16 KA, 415 V, 50 Hz adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
80All as per item no. 78 above but 160 Amps,36 KA complete all as specified and as directed.
81All as per item no. 78 above but 200 Amps,36 KA complete all as specified and as directed.
82All as per item no. 78 above but 250 Amps,36 KA complete all as specified and as directed.
83S & F in replacement air termination single pointed aluminium rod 12 mm dia and 300 mm long fitted on exisiting lightening conductor tube 40 mm on buildings with F clamps nut bolts complete all as specified and directed.
84S & F in replacement earth test point terminal block made out of gun metal or phorphorus bronze size 75 x 75 x 5 mm , drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw grouting on wall with PCC, nut bolts and washers, including making good to disturbed surface complete all as specified and directed.
85S&F in replacement of Galvanised iron strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and as directed .
86S & F in replacement of aluminium strip 25 x 3.15 mm with saddle and fixing screws, gutties etc on wall and roof top conductors including grouting wooden gutties complete all as specified and directed.
87M&L for constructing Earth pit of internal size not less than 300x300x150mm PCC 1:3:6 type C 1 chamber, RCC cover slab of 50 mm thick 1:2:4 with suitable handle.Dismantling old unsv one.
88M& L in replacement of Earthing complete with Galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal Ground Level connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers and earth strip protected by 40zmm dia GI pipe medium grade connected to main Panel point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways , GI funnel with watering pipe 20 mm dia, wire mesh, salt and charcoal, protection pipe for earth strip upto 7.50m long complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified in SSR part-II earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
89Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
90Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been errected and tested , all as specified.
91Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
92Supply and laying double wall corrugated pipe (DWC) confirming to IS 14930 Part-I of size 110 mm outer dia and 95 mm inner dia including taking out old unserviceable complete all as specified and as directed.
93Ditto- all as per item 91 but of size 90 mm outer dia and 76 mm inner dia complete all as specified and as directed.
94Ditto- all as per item 91 but of size 77 mm outer dia and 63 mm inner dia complete all as specified and as directed.
95Taking out existing worn out/old XLPE under ground cable in 4 core of 35 sqmm to 120 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
96Supply, laying , jointing ,testing and commisioning LT underground cable 1100 volts grade XLPE insulated and steel strip or wire armoured heavy duty with multistranded aluminium conductor 16 Sqm 4 core size including making all incoming and out going connections through proper lugs/thimbles complete all as specified and directed.Note:- (i) Excavation and earth work cable protection and sand cushioning shall be measured and paid seperately.
97All as per item No: 95 here in before but size 35 sqmm 3.5 core complete all as specified and as directed.
98All as per item No: 95 here in before but size 70 sqmm 3.5 core complete all as specified and as directed.
99All as per item No: 95 here in before but size 120 sqmm 3.5 core complete all as specified and as directed.
100Material and labour for road / path way any type (Concrete) cutting , including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boulders/ stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as directed.
101Servicing of electrically operated over head travelling cranes (EOT), double girder type (Flame proof ) of 5.0 tonne capacity installed at P-103 & P-118 AC Plant comprising of electric motor for long travel, cross travel, hoist motion, VVVF Drive and electric control panel consisting of MCCBs /Main switches , step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, with oil, motor bed ends, electrical control cables etc including lubrication/ greasing/ oiling complete for smooth operation of cranes by skilled service engineer/mechanic complete all as specified & directed.
102Notes for Ser item No:100:- (i) Taking out / down of unserviceable spare parts are included in quoted rates and S&F of new spare parts shall be measured and paid separately. Item will be provided as per existing make/size .(ii) The servicing of each crane throughout the contract period shall be responsibilty of contractor and shall quote accordingly. (iii) The record of servicing shall be maintained by the contractor. iv) The following parts (to be checked) included in the quoted rates :- (a) Motors- Check terminal connections slip rings, carbon bushes alignment of motors, couplings, clutches, brakes if any tight/adjust if required.(b) Wire Rope – Check lubrication and number of broken wires. (c) Hook – Check for free rotation of hook, lubrication/ greasing/ oiling of moving parts.(d) Electrical – Check contactor tips limit switch operating mechanism including connections & testing of LT panel of crane complete.(e) Cleaning of all parts and rail/wheel of cranes.(f) Checking of all movement i.e Long Travel, Cross travel, lifting and/or any other part as decided by the Engineer-in-charge.(v) Detection of oil leakage rectification of the same along with replacement of oil seal demeed to included in quoted rates.
103M&L for static & dynamic load testing, health inspections of complete cranes capacity 5 tonne include mechanical component for cracks, corrosion, improper function, deformation and oil leakages guide rails and electrical component, safety devices, hooks, rope, hoist brake, motor, coupling & gear, rope drum, limit switch control device including inspection to all connected parts of cranes complete all as specified & directed.
104Attending complaints of EOT/HOT crane installed at P-103 & P-118 AC Plant of capacity 5 Tonne, complaint of any nature on emergency call given by concern Engineer-in-charge/JE, by providing skilled service engineer/ mechanic for locating the electrical and mechanical fault and rectification of the fault within two day to the entire satisfaction level of the Engineer-in-charge complete all as specified & directed. Notes:- (i) Taking out / down of unserviceable spare parts are included in quoted rates and S&F of new spare parts required for rectification of fault shall be measured and paid separately. Item will be provided as per existing make/size .(ii) The complaints shall be attended by the contractor within 48 hours. A penalty of Rs. 500/- per hour will be recovered/made for not attending the complaint/non rectification of fault beyond 48 hours upto 72 hours, after intimation of concerned AGE/JE in writing. A penalty of Rs. 12000/- per day (for every 24 hours) will be made for not attending the complaint beyond 72 hours. (iii) The contractor will be responsible for providing T&P to the personal deployed, as per requirements for rectifying the faults.(iv) If the nature of fault for which rectification is involved comes beyond the scope of contract, the same shall not be considered for any type of penalty.(v) Site visit by the contractor /service engineer / mechanic for any number of time requierd to make EOT crane serviceable condition /upto satisfaction of user will be considered only one job, cost of this aspect deemed to be included in quoted rates.(vi) Any minor parts which is not included in BOQ here-in-after but required for satisfactory operation of EOT crane deemed to be included in quoted rates.
105M&L for brake adjustment of any crane of any capacity including load testing in presence of JE/Engr-in- Charge complete all as specified & directed
106S&F HRC fuse 20 Amp to 32 Amp capacity complete all as specified & directed.
107S&F single phase preventer complete all as specified & directed.
108S&F timer relay, encapsulated on delay Timer Type SAS-P (Solid State output) Voltages : 240 volt AC, 110 volt AC, 48 volt AC/DC, 24 volt AC/DC, Time Range : 1 second or 0.1-10 Second or 1-100 Second or 3-300 Second complete all as specified and as directed.
109S&F in repair as per existing size or 100 mm dia Flameproof Thrustor Operated Brake (Type \\"FLPMTOB\\" ) with 18 Kg Flameproof Thrustor Type 'ETF-240' suitable for Gas Group-IIB, Zone-1&2, as Per IS:2148, 415 volt AC, 3 Phase, 50 Hz, Braking Torque 9 Kg-mtr complete all as specified & directed.
110S&F in repair as per existing or 100 mm dia brake lining of electromagnetic thruster 100 FLP complete all as specified & directed.
111S&F brake shoe thrust assembly with lining set 415 volt AC, 3 phase 50 Hz fill with transformer oil EHD grade 'B' class suitable for main hoist and for vertical drive of size 5 ton capacity complete all as specified & directed.
112S&F push button for moveable pendant and making necessary connections including testing complete all as specified & directed.
113S&F Emergency stop switch for flame proof pendant and making necessary connections including testing complete all as specified & directed.
114S&F contactor 3 pole, 415 volts, 40 Amps complete all as specified & directed.
115S&F over load relay, Built-in Single Phasing protection, mounting type capacity 12-24 Amps complete all as specified & directed
116S&F thermal over load relay, Built-in Single Phasing protection mounting type capacity 6-12 Amps complete all as specified & directed
117S&F breaking resister 2000 Watt, 1 Ohm to 5 Kilo-Ohm or existing capacity Motor capacity complete all as specified & directed.
118S&F flame proof limit switch, 40 amps rating with one NO & one NC for long travel & cross travel complete all as specified & directed.
119S&F flame proof limit switch, 40 amps rating with rotory gear of main hoist complete all as specified & directed.
120S&F variable speed drive 3 Phase, 415 volt, 4KW, 5HP suitable for motor installed on EOT Crane with overvoltage protection, undervoltage protection, overcurrent protection and short circuit protection and making necessary connections including testing complete all as specified & directed
121S&F flame proof pendant suitable for 5.0 ton capacity gantry complete all as specified & directed.
122S&F wheel bearing as per existing size / Make after taking down unserviceable/ wornout wheel bearing as existing at site complete all as specified & directed.
123Taking down/out existing long travel wheel, cross travel wheel from gantry for repair by filling of bronze material by welding & brazing, turning, grinding and refixing the same to make it functional complete all as specified & directed. Note: Cost of transportation to workshop shall deemed to be included in quoted rate.
124M&L for Rewinding of motor capacity 3 HP, 415 volt, 3 phase with super enameled copper conductor as per existing weight, size and design etc. varnishing, baking and testing including taking down unserviceable / wornout winding of flame proof / non flame proof motor mounted on rail complete all as specified & directed.
125S&F in replacement of control cable, 2.5 sqmm 4 core, stranded copper conductor, unarmoured, 1100 volt grade, FRLS PVC insulated PVC sheathed with supporting steel/GI wire for fixing complete all as specified & directed.
126Taking down/out travelling crab of double girder 5 tonne capacity, electric operated crane for rectification of fault and re-installing with and including replacing testing complete all as specified & directed.
127Dismantling & taking out of gear box of EOT gantry 5000 Kg capacity, for rectification of fault & re-installing the same including replacing of unserviceable bearing, bush, gears of existing make and size including turning, welding, grinding and testing complete all as specified & directed.
128S&F in replacement bearing block of existing make & size at site complete all as specified & directed.
129M&L for dismantling of unserviceable rotating shaft & keyways from travelling crab and transporting to & from to workshop for checking & repairing and making new keyways including inserting new key as per existing/site requirement for fully functional of EOT crane complete all as specified & directed.
130M&L for replacement checking electric circuits of any EOT crane and locating the fault, rectifying the fault and replacing the unserviceable parts if required and ensuring furntionality of EOT cranes including replacement of burnt/wornout wires complete all as specified & directedNote: Spare parts to be measured and paid seperately.
131M&L in replacement of cable roller with superior quality plastic roller to the existing cable complete all as specified & directed.
132S&F Rotary Geared Shunt limit switch with 2NC contact and gear ratio 48:1, contactor rated 40 Amps, 415 volt AC complete all as specified & directed.
133S&F Two way lever type Shunt limit switch with 3NC contact and contact rated for 40 Amps at 415 volt AC complete all as specified & directed.
134S&F Counter weight limit switch with 1NC contact and contact rated for 40Amps at 415 volt AC complete all as specified & directed.
135S&F Variable Voltage Variable frequency Drive (VVVFD) 3 Phase, 415 Volt, 5.5KW for electric crane complete all as specified & directed.
136S&F in replacement steel wire rope 10mm dia rope 6x36 construction, tensile grade 1770 N-Sqmm confirming to IS 2266/2002 with suitable size 'D' clamp, nuts, bolts and washers complete all as specified & directed.Note for Ser item No.136: The Nut, Bolt, washer shall be mesured & paid seperately.
137M&L for apply two coat of epoxy paint by spray painting m/c on site,including preparation of rusted surface of Gantry Crane any type and capacity and writing SM No./MES No.complete all as specified and as directed.
138S&F in repair hexagonal or square nuts, bolts with hexagonal or square heads at one end and screwed the other or screwed both ends and washers of any size any type complete all as specified & directed.
139M&L in replacement of gear oil, crane duty, helical gear box oil as per OEM recommendation complete all as specified & directed.
140M&L in replacement of synthetic gear oil VG680 for hoist thrust brake complete all as specified & directed
141M&L in replacement of semi synthetic gear oil EP320 for gear box complete all as specified & directed
142Meterial and labour for cement concrete in foundations for pole or any other work type D2 1:4:8 with 40 mm graded crushed stone aggregate all as directed.
143Meterial and labour for cement concrete in foundations for pole or any other work type C2 1:3:6 with 40 mm gradedcrushed stone aggregate all as directed
144Meterial and labour for cement concrete in foundations for pole coping or any other work type B1 1:2:4 with 20mm graded crushed stone aggregate all as directed
145Panel No:01 Supply , Installing ,testing and commissioning, weather,vermin proof LT Feeder pillar box of suitable size factory fabricated(Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick MS sheet and inner comparments of 2.00mm thick steel sheet enclosure with double door shutter with locking arrangement including 04 No's of angle iron legs length 0.75 Mtr made out of 50mmx50mmx6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system with hinged panel door(covers) on two sides with handle,bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade with PCC foundation mounted on epoxy insulators with and constitute the following:-
146Cont... Ser item No:144:- Note:- Including foundation work shall be includedin this quoted rate.(a) INCOMING (i) MCCB 4 Pole, 415 V, Adjustable type,350 Amps with breaking capacity 36 KA(I/C): 01 No (ii) Voltmeter 0-500 volts, (digital type) square, 144 mm, flush pattern with 3 way rotary selector switch - 01 No(iii) Ammeter size 144 mm,(digital type) square dial, flush pattern having dual range 500 amps with three way rotary selector switch with suitable size CT's- 01 No(vi) Indicating lamps :---o1 set of three(v) Aluminium bus bar 1.5 times of rated current of incoming MCCB with heat shrink insulation and mounting insulators : ­­ 01 setOUTGOING (i) MCCB 4 Pole,415 Volts, fixed type, 125 Amps with breaking capacity 16 KA (O/C) : 03 No's(ii) MCCB 4 Pole,415 Volts, fixed type, 63 Amps with breaking capacity 16 KA (O/C) : 02 No's(iii) Isolator DP 63 Amp 230 Volt (O/C) : 03 No
147Panel No:02 All as per Item No: 144 here in before but the following accessories are inbuilt in this items:-(a) INCOMING (i) MCCB 4 Pole, 415 V, Adjustable type,250 Amps with breaking capacity 36 KA(I/C): 01 No (ii) Voltmeter 0-500 volts, (digital type) square, 144 mm, flush pattern with 3 way rotary selector switch - 01 No(iii) Ammeter size 144 mm,(digital type) square dial, flush pattern having dual range 500 amps with three way rotary selector switch with suitable size CT's- 01 No(vi) Indicating lamps :---01 set of three(v) Aluminium bus bar 1.5 times of rated current of incoming MCCB with heat shrink insulation and mounting insulators : ­­ 01 setOUTGOING (i) MCCB 4 Pole,415 Volts, fixed type, 125 Amps with breaking capacity 16 KA (O/C) : 01 No's(ii) MCCB 4 Pole,415 Volts, fixed type, 63 Amps with breaking capacity 16 KA (O/C) : 04 No's(iii) Isolator DP 63 Amp 230 Volt (O/C) : 02 No
148Supply & fixing in replacement of Busbar chamber 200 Amps, TPN 8 way minimum length 460mm long enclosed in sheet metal enclosure with and including 04 No's of angle iron legs length 1.2 made out of 50mmx50mmx6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system including consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade including all the fixing arrangements, making all incoming and out going connections through the lugs/thimbles all as specified and directed .Note: PCC item will be measured and paid separately.
149Supply & fixing in replacement of Busbar chamber 200 Amps, TPN 8 way minimum length 460mm long enclosed in sheet metal enclosure with and including 04 No's of angle iron legs length 1.2 made out of 50mmx50mmx6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system including consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade including all the fixing arrangements, making all incoming and out going connections through the lugs/thimbles all as specified and directed .Note: PCC item will be measured and paid separately.
150Earthing complete with Galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below the normal ground level) with top edge of the plate not less than 1.5 m below normal Ground Level connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers and earth lead protected by 15mm dia GI pipe medium grade connected to main distribution board/ earthing test point all as shown on electrical plate No-03 of SSR Part-1 and all as specified including testing on completion.Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways , GI funnel with watering pipe 20 mm dia, wire mesh, salt and charcoal, protection pipe for earth lead upto 7.50m long complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified in SSR part-II earth lead wire and protection pipe beyond 7.5m shall be measured and paid separately. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56457365
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.80 Lakhs
LAST DATE 04-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Overhead Cranes, Misc Machinery, Dg Sets And Lighting Protection System Including Connected Works At 15 Fad Jindrah Under Ge (Army) Dhar Road Udh Ur
Basic Detail
Tender No CWE/U(DR)-52 /2026-27
Bidding Type Tender
Location
City Reasi
State Jammu and Kashmir
Key Dates
Publish Date 14 Jul 2026
Submission Date 04 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 44.80 Lakhs
Tender Fee 500
EMD 89600
Exemption Not Available
Document List
8ec22640-0b92-473d-a213-d101aab36a2d.html
BOQ_871929.xls
Tenderdocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

8ec22640-0b92-473d-a213-d101aab36a2d.html

xls

BOQ_871929.xls

pdf

Tenderdocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender