Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56457349

Tender For Provision Of Transformer, Panels And Ht/Lt Cables For Mh And Dsoi At New Cantt Under Ge (West) Prayagraj.

Issued by Statutory Bodies & Commissions/Committees · Prayagraj, Uttar Pradesh
Tender Value
53.59 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
13 days left
EMD
1.05 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Transformer, Panels And Ht/Lt Cables For Mh And Dsoi At New Cantt Under Ge (West) Prayagraj.

BOQ

Name of Work:- PROVISION OF TRANSFORMER, PANELS AND HT/LT CABLES FOR MH AND DSOI AT NEW CANTT UNDER GE (WEST) PRAYAGRAJ.
Sl. No. Item Description
1Supply, install, testing and commissioning and testing of outdoor type,Transformer 800 KVA capacity step down with dual ratio on HT side 11/0.433 KV at no load 3 phase , 4 wire AC, 50 Hz, AC double wound core type copper wound ,oil immersed ,air natural cooled with external cooling tubes ,transformer delta coonection on HV Side and star coonection on LV side in accordence with vector symbol Dyn-II with neutral brought out on secondary side and having tapping in step of ± 7.5% step of 2.5% each to be changed by means of hand operated off load tap changing gear arrangement including first fill of transformer oil as per IS -335 and including all fitting /accesories as specified in SSR Part -I and IS -1180 Part I/2014 (revised) BEE Star rated energy saving.( Energy efficiency level -3) Transformer should have cable box on LT side and brass bushing on HT side ,oil temprature guage ,dehydrating breather with first fill of dehydrating silica gel ,oil conservator tank ,explosion vent ,rating and terminal marking plate, oil level guage ,oil drain and filter valve ,independent earth point and neutral fittings ,earth terminal at bodybase ,voltage regulation should be as per IS and limit of temp rise after contineous full load run as specified in SSR part -I and is - 1180 Part I (revised) shall be stand by adjusted to suit the maximum ambient temp prevaling at site all as specified comprising with the following specification :-
2(a) Earthing terminal and rating diagram plate.(b) Air release device.(c) Oil filling inlet pipe with plug.(d) Drain outlet pipe with brass gate valve with dummy plug.(e) Conservator with level gauge.(f) Silica gel with breather.(g) First Oil fill up to the recommended level by the manufacturer with new oil conforming to IS 335. (h) Type of connection Delta/Star.(j) Type cooling : ONAN.(k) Vector Group : DYN 11.(l) Type of connecting arrangement cable termination boxes on HT side and on LT side.(m) Oil temperature gauge 100mm dia dial type. (n) Buchholz relay.(o) Plateform for Transformer of size 4000mm x4000 mmx 1200mm alongwith fencing & gate shall be provided all as specified & shown on drawing No. CELZ/TD-699 sheet 1/1.(p) Two Nos GI tubing light grade 100mm dia 60cm long embedded in brick/wall on LT/HT side for drawing underground cable.Note: Testing and commissioning of transformer shall be carried out by SEI from HQ CE CC before issue of completion.
3Supply, install, testing and commissioning and testing of outdoor type,Transformer 200 KVA capacity step down with dual ratio on HT side 11/0.433 KV at no load 3 phase , 4 wire AC, 50 Hz, AC double wound core type copper wound ,oil immersed ,air natural cooled with external cooling tubes ,transformer delta coonection on HV Side and star coonection on LV side in accordence with vector symbol Dyn-II with neutral brought out on secondary side and having tapping in step of ± 7.5% step of 2.5% each to be changed by means of hand operated off load tap changing gear arrangement including first fill of transformer oil as per IS -335 and including all fitting /accesories as specified in SSR Part -I and IS -1180 Part I/2014 (revised) BEE Star rated energy saving.( Energy efficiency level -3) Transformer should have cable box on LT side and brass bushing on HT side ,oil temprature guage ,dehydrating breather with first fill of dehydrating silica gel ,oil conservator tank ,explosion vent ,rating and terminal marking plate, oil level guage ,oil drain and filter valve ,independent earth point and neutral fittings ,earth terminal at bodybase ,voltage regulation should be as per IS and limit of temp rise after contineous full load run as specified in SSR part -I and is - 1180 Part I (revised) shall be stand by adjusted to suit the maximum ambient temp prevaling at site all as specified comprising with the following specification :-
4(a) Earthing terminal and rating diagram plate.(b) Air release device.(c) Oil filling inlet pipe with plug.(d) Drain outlet pipe with brass gate valve with dummy plug.(e) Conservator with level gauge.(f) Silica gel with breather.(g) First Oil fill up to the recommended level by the manufacturer with new oil conforming to IS 335. (h) Type of connection Delta/Star.(j) Type cooling : ONAN.(k) Vector Group : DYN 11.(l) Type of connecting arrangement cable termination boxes on HT side and on LT side.(m) Oil temperature gauge 100mm dia dial type. (n) B uchholz relay.(o) Plateform for Transformer of size 4000mm x4000 mmx 1200mm alongwith fencing & gate shall be provided all as specified & shown on drawing No. CELZ/TD-699 sheet 1/1.(p) Two Nos GI tubing light grade 100mm dia 60cm long embedded in brick/wall on LT/HT side for drawing underground cable.Note: Testing and commissioning of transformer shall be carried out by SEI from HQ CE CC before issue of completion.
5Supply, laying & testing cross linked polyethylene insulated (XLPE) galvanised steel strip armoured HT cable with aluminum conductor, 11 KV `E’, of cross sectional area 120 Sqmm, three core (IS-7098) in trenches/through pipes/ducts or on poles at crossing of OH lines of MES and road crossing and including cable indicator complete all as specified and directed .
6Supply, laying of LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as specified and directed .
7Supply, laying of LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed .
8Supply, laying of LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and directed .
9Supply, laying of LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed .
10Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm complete all as specified and directed.
11Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil including bottom surface to required level or slope for laying of cable etc. complete all as specified and directed.
12Returning filling in excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each in soft/loose soil complete all as specified and directed.
13Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
14M&L sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches and consolidated complete all as specified and directed.Note : Punned thickness 18 cm only shall be considered for payment.
15Supply & Laying Sub-Class old size B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed.
16Supplying and laying un-reinforced precast concrete cable cover, class HVP,type 1 with peak, size 300mm x 180mm x 40mm to cover/laid over the cable in cross direction to give mechanical protection to under ground cable complete all as specified and directed. Please Enable Macros to View BoQ information
17Supplying and laying un-reinforced precast concrete cable cover, class HVP,type 1 with peak, size 300mm x 180mm x 40mm to cover/laid over the cable in cross direction to give mechanical protection to under ground cable complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56457349
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 53.59 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Transformer, Panels And Ht/Lt Cables For Mh And Dsoi At New Cantt Under Ge (West) Prayagraj.
Basic Detail
Tender No 81914/W/E8
Bidding Type Tender
Location
City Prayagraj
State Uttar Pradesh
Key Dates
Publish Date 14 Jul 2026
Submission Date 28 Jul 2026
Open Date 04 Aug 2026
Finance
Tender Value 53.59 Lakhs
Tender Fee 1000
EMD 1.05 Lakhs
Exemption Available
Document List
136d0cc3-571a-4029-ae76-8d6b2bdd3f90.html
BOQ_871844.xls
Errata.pdf
Makes.pdf
Particularspecifications.pdf
Specialcondition.pdf
Tenderdocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

136d0cc3-571a-4029-ae76-8d6b2bdd3f90.html

xls

BOQ_871844.xls

pdf

Errata.pdf

pdf

Makes.pdf

pdf

Particularspecifications.pdf

pdf

Specialcondition.pdf

pdf

Tenderdocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders