Tender For Expression Of Intrest To Installtion Of Solar Grid At Swm Landfill Site Of Mandya Cmc. Only For Rate Approval
Tender Overview
Project Description
Tender For Expression Of Intrest To Installtion Of Solar Grid At Swm Landfill Site Of Mandya Cmc. Only For Rate Approval Solar Panel Solar Pv Module: N-Type Topcon Bifacial Double Glass Module, Dcr Compliant, 550 Wp Capacity, 23.13% Module Efficiency, 132 Cells, Vmp 41.30 V, Imp 15.14 A, Voc 49.90 V, Isc 15.95 A, Power Tolerance 0 To +2%, Bifaciality Factor 80 ± 5%, Dimensions 2382 × 1134 × 30 Mm, Silver Anodized Aluminium Frame, 2.0 Mm Heat-Strengthened Front Glass And 2.0 Mm Ar-Coated Semi-Tempered Rear Glass, Ip68 Junction Box With 3 Bypass Diodes, Maximum System Voltage 1500 Vdc, Series Fuse Rating 30 A, Operating Temperature -40°C To +85°C, Nmot 45 ± 2°C, Temperature Coefficients: Pmax -0.30%/°C, Voc -0.25%/°C, Isc +0.045%/°C, Mechanical Load Capacity 5400 Pa Snow Load And 2400 Pa Wind Load, Class A Application, Class Ii Electrical Safety, Class C Fire Rating, 12-Year Product Warranty And 30-Year Linear Performance Warranty. Microinverter Dc Input Power: 2000 W, Number Of Channels: 4, Pvpanel Rating:Upto 680Wp Perchannel,Maxinputdccurrent:16Aper Channel, Full Power Mppt Voltage Range: 34–45 V, Extended Mppt Voltage Range: 20–60 V, Start-Up Voltage: 19 V, Dc Connection Type: Mc4 Compatible, Grid Connection Type: 230V L-N (1-Phase), Operationalvoltagerange:184–276V,Max Continuous Power: 2000 W @ 60°C, Nominal Output Frequency: 50 Hz, Frequency Range: 47.5–52.5 Hz, Power Factor: >0.99 (Programmable), Output Thd:<2%, Inrush Current: <8 A, Output Wiring: 14 Awg, Output Connector: T5 Ac Micro Male, Off-Grid Voltage Range: 90–245 V, Off-Grid Frequency: 54–56 Hz, Certifications: Ul1741, Rule 21, Ieee1547, Iec 61727, Is 16221, Reverse Voltage Protection: Yes, Anti-Islanding: Yes (Programmable),Gfdi: Integrated, Isolation: Galvanic, Trip Time: <200 Ms, Max Efficiency: 97.5%, Cec Efficiency: 97%, Mppt Efficiency: Static 99.85%, Dynamic 99.8%, Standby Consumption: <30 Mw, Monitoring: Wireless,Web-Based, Operating Temp: -40 To +65°C, Relative Humidity: 0–1 100% Condensing. Iotsmartgateway Connectivity:Ltecat-1Bandb3/B5/B40, Zigbee 3.0 (2.4 Ghz), Leds: 2 (Lteindicator, 1 Reserved), Antenna: Built-In, Power Requirement: 12V 1A Dc (2.1Mm Barrel Jack, Center Pin Positive), Power Backup: Li-Ion 3.7V 450Mah Rechargeable, Inverterconnectivity:Upto6Inverters,Data Update Interval: 10 Minutes (Configurable), Data Storage: Approx. 48 Hours With One Inverter, Enclosure: Ip65 With Tie-Wrapmount (4 Ear Lobes), Mounting Method: Outdoor, Suitable For Pole, Wall, Or Tower, Operating Temperature: -10°C To +70°C, Storage Temperature: +20°C To +85°C,Humidity:95%Non-Condensing,Sim:Esim, Warranty: 12 Months. Zigbee-Enablediot-Basedsolardatalogger Ac Voltage Range: 100–240V (Single Phase), Frequency Range: 50–60Hz, Max Current: 2.5A, Dc Input Voltage: 5V, Dc Inputcurrent:0.6Atypical,Cooling:Natural Convection, Ambient Temp Range: 0–50°C (0–122°F), Enclosure: Indoor Only, Dimensions: 92Mm X 73Mm X 37Mm,Weight: 200G, Mounting: Wall Mount Or Self-Standing, Inverter Communication: Wireless (Modified Zigbee-Ha), Lan: Ethernet 10/100Mbps, Wi-Fi, Inverter Capacity:Recommended Max 30 Inverters, On-Device Data Storage: Up To 25 Years, Warranty: 5Years, Compliance: Fccpart15 Class B, Csa22.2 60950-1, Ul 60950 Ltpanelsupply & Installing Of Outdoor Type (Ip-65) Lt Panel 415V63A 4P MccbS, Spd Type I&Ii,Iot-Integratedmonitoring,01NoSas Incomer And Required Accessories With Suitable Glands And Indications Lamps & Universal Standard 3-Pin, Real-Time Power Distribution Tracking. Acdb Polycarbonate Box Enclosure, Acspd Type 2, Ac Mcb, Changeover Switch, Ryb Indicators For Each Phase, Ip 65 Enclosure, Fuse Protection For Each Strings, Cable Glands And Connectors For Input And Output.63A, 415Vcapacity:50Kw Dccablesupply & Installing Copper,1.1Kv,Electron Beam Xlpo Outer Sheath, Black Color, Dc Cables Complying To Tuv 2Pfg 1169/09.07.1.5Kvdc,1Cx4Sq.Mm Pvc Insulated Uv Pvc Sheathed Copper Cable - Red,1.5Kvdc,1Cx4Sq.Mm Pvc Insulated Uv Pvc Sheathed Copper Cable -Black Lightening Arrestor Conductors Supply & Installing Of Aluminum ,Frl Swith Galvanized Steel Armoring Minimum Area Of Coverage 90%, Xlpe Insulated Compliant To Is 1554 And Iec 60189, With Distinct Extruded Xlpe Inner Sheath Of Black Color As Per Is 5831. If Armored, Galvanized Steel Armoring Tobeused With Minimum 90% Area Of Coverage. H4 Grade Aluminum Strandedclass-2.1.1Kv4C X 2520Sqmm.A2Xfycable (From Inverter To Acdb Panel) Acearthingconductor Supply & Installing Of Pvc Insulated Flexible Cu Cable High Conductivity Copper Rods Complying Is: 8130-1984 And Its Amendments.0 51.1Kv1C X6Sqmm Y Cable For Inverter Earthing-Green/Yellow Earthingkit Maintenance Free Earth Electrode With Chemical Earthing Set 3Mtr Long 17.2 Mmdia, Copper Bonded, Thickness Of 250 0Microns Electroderod Copper-Bonded Earthing Electrode, 50 Mm Diameter, 3-Meter Length, Copper Bonding Thicknessminimum250Microns,Corrosion- Resistant,Low-Resistancetype,Conformingto Ieee80 And Is 3043 Standards, With Terminal Clamp And Backfill Material, Includingexcavationandrefilling,Completeinall Respects. Pre-Gi Solar Mounting Structure Pre-Gi Solar Mounting Structure: Pre-Galvanized Iron Structure Fabricated And Assembled On Site; Main Legs 80×40×2 Mm Gi Box Section; Rafters 80×40×2 Mm Gi; Purlins 60×40×1.6 Mm Gi; Base Plates Ms 6–8 Mm Fixed With Ss/High-Tensile Wedge Anchor Bolts On Rcc Base; Gi Struts For Bracing; U-Type Gi/Ss Fixing Bolts; Aluminum Anodized Mid And End Clamps 25 Mm Width; Ss 304 Bolts, Nuts, And Washers; Pre-Galvanized Coating ≥120 Gsm As Per Is 277; Designed For Wind Load Up To 150 Km/H Per Is 875; Tilt Angle 10°–15°; Cold-Galvanized Touch-Up At Cut Edges; Complies With Is 2062, Is 800, Is 1367, Iec 62548; All Surfaces Smooth, Rust-Free, Properly Aligned And Corrosion-Protected; Suitable For Rooftop Installation With Concrete Base And Adjustable Alignment. Solarsysteminstallation Solar System Installation: Installation, Testing, And Commissioning Of Complete Solar Pv System Including On-Site Erection Of Pre-Gi Mounting Structure, Mounting And Alignment Of Solar Panels With Aluminum Mid And End Clamps And Ss Fasteners, Installation Of Solar Inverter On Wall Or Pedestal, Laying Of Solar-Grade Dc Cables From Panels To Dcdb, Dcdb To Inverter, Inverter To Acdb, And Acdb To Lt Panel Through Uv-Resistant Hdpe/Gi Conduits, Panel-To-Panel String Looping Using Mc4 Connectors, Provision Of Dcdb With Mcb, Fuses, And Spd Type Ii Protection, Acdb With Mccb And Spd, Proper Terminations With Crimped Lugs And Ferrules, Installation Of Earthing Network Including Separate Earth Pits For Dc, Ac And Lightning Arrestor Using Gi Electrodes And 25×3 Mm Gi Strips, Installation Of Lightning Arrestor With Gi Down Conductor, Handling, Loading, Unloading, Shifting, And Placement Of Materials Including Use Of Crane And Transportation For Solar Panels, Structures, And Inverters, All Works As Per Is 3043, Is 2309, Is 732, Iec 62548, Is/Iec 60364 And Mnre Standards, Ensuring Neat Workmanship, Corrosion Protection, Labeling, Testing, And Commissioning Of The Complete System.. And Comprehensivemaintenancefor5Years Smartbidirectionalmeter 3Phase Bidirectional Smart C T Energy Meter And Escom Energy Meter Approval Charges, Application Charges, Agreement Making And Synchronization.
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Offline submission at the designated office.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender