Health and Family Welfare Government Departments Closing in 23 days TDR #56455262

Tender For Re E Tender For Procurement Of Kits, Chemicals & Reagents For Two Years From The Date Of Award Of Contract (Aoc) And Its Extension, If Required

Issued by Government Departments · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Aug 2026
23 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Re E Tender For Procurement Of Kits, Chemicals & Reagents For Two Years From The Date Of Award Of Contract (Aoc) And Its Extension, If Required , Rh +K Phenotyping Glass Bead Cassettes Technical Specification: 1.Cassttes Should Contain 6 Columns Filled With Glass Bead As Filtration Media 2.1St Column To 5Th Column Should Be Prefilled With Monoclonal Antisera Such As Anti C, Anti E, Anti C, Anti E, Anti K Respectively And 6Th Column Is Control Column. 3.Peg Should Be Present In The Columns As Enhancer To Increase Uptake Of Antibody 4. Assay Time Should Be As Per Manufacturers Guideline / Brochure 5. Mixed Field Reaction /Double Cell Population Should Be Detected , Ahg Poly Specific Glass Bead Cassettes Technical Specification: 1. Cassettes Should Contain 6 Columns Filled With Glass Beads Filtration Media 2. All Column Should Prefilled With Ahg Reagent (Anti Igg , Anti C3d) 3. Assay Time Should Be As Per Manufacturers Guideline / Brochure 4. Mixed Filled Reaction /Double Cell Population Should Be Detected , Blood Grouping (Forward & Reverse Grouping) Glass Bead Cassettes Technical Specification: 1. Cassettes Should Contain 6 Columns Filled With Glass Bead As Filtration Media 2. 1St To 3Rd Colums Should Be Prefilled With Monoclonal Antisera With A Serial Of Anti A, Anti B, Anti D Respectively And Rest 3 Colums Contain 1 For Control And 2 Colums For Reverse Grouping With Variable Serial. 3. Peg Should Be Present In The Columns As Enhancer To Increase Uptake Of Antibody 4. Centrifugation Time Should Be As Per Manufacturers Guideline 5. Mixed Field Reaction /Double Cell Population Should Be Detected , Monoclonal Antisera For Extended Rh+K Phenotyping Anti C Technical Specification: Anti C Sera Should Be Monoclonal Anti C Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Monoclonal Antisera For Extended Rh+K Phenotyping Anti C Technical Specification: Anti C Sera Should Be Monoclonal Anti C Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Monoclonal Antisera For Extended Rh+K Phenotyping Anti E Technical Specification: Anti E Sera Should Be Monoclonal Anti E Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Monoclonal Antisera For Extended Rh+K Phenotyping Anti E Technical Specification: Anti E Sera Should Be Monoclonal Anti E Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Monoclonal Antisera For Extended Rh+K Phenotyping Anti K (Kell) Technical Specification: Anti K Sera Should Be Monoclonal Anti K Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Panel For Antibody 3 Cell Screening Applicable To Conventional Test Tube Method And Glass Bead Cassettes Technical Specification: 1. Cell Panel Should Be 2%-5% Of Rbc Suspended In Saline 2. Cell Panel Should Be Compatible With Both Conventional Test Tube Method And Glass Bead Cassettes Of Column Agglutination Technology For Doing Antibody Screening Test 3. Cell Panel Should Contain Rbc With The Antigens Of Extended Rh, Kell, Duffy, Kidd, Lewis, Mns Etc Blood Group System 4. Dose Depended Antigens (Like Mns, Duffy Etc) Should Be Present In Homozygous As Per Criteria Of Antibody Screening Test 5. Cell Panel Should Be Compatible For Enzyme Treatment 6. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Panel For Antibody 3 Cell Screening Applicable To Gel Card Technical Specification: 1.Cell Panel Should Be 0.8%-1% Of Rbc Suspended In Low Ionic Strength Saline 2. Cell Panel Should Be Compatible With Gel Card Of Column Agglutination Technology For Doing Antibody Screening Test 3. Cell Panel Should Contain Rbc With The Antigens Of Extended Rh, Kell, Duffy, Kidd, Lewis, Mns Etc Blood Group System 4.Dose Depended Antigens (Like Mns, Duffy Etc) Should Be Present In Homozygous As Per Criteria Of Antibody Screening Test 5. Cell Panel Should Be Compatible For Enzyme Treatment 6. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Panel For Antibody 11 Cell Identification Test Applicable To Conventional Test Tube Method And Glass Bead Cassettes Technical Specification: 1. Cell Panel Should Be 2%-5% Of Rbc Suspended In Saline 2. Cell Panel Should Be Compatible With Both Conventional Test Tube Method And Glass Bead Cassettes Of Column Agglutination Technology For Doing Antibody Identification Test 3. Cell Panel Should Contain Rbc With The Antigens Of Extended Rh, Kell, Duffy, Kidd, Lewis, Mns Etc Blood Group System 4. Dose Depended Antigens (Like Mns, Duffy Etc) Should Be Present In Homozygous As Per Criteria Of Antibody Identification Test 5. Cell Panel Should Contain Rbc With The One Or More Heterozygous Expression Of Dose Dependent Antigens (Mns,Duffy) For Better Interpretation Of Result. 6. Cell Panel Should Be Compatible For Enzyme Treatment 7. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Panel For Antibody 11 Cell Identification Test Applicable To Conventional Test Tube Method And Glass Bead Cassettes Technical Specification: 1. Cell Panel Should Be 2%-5% Of Rbc Suspended In Saline 2. Cell Panel Should Be Compatible With Both Conventional Test Tube Method And Glass Bead Cassettes Of Column Agglutination Technology For Doing Antibody Identification Test 3. Cell Panel Should Contain Rbc With The Antigens Of Extended Rh, Kell, Duffy, Kidd, Lewis, Mns Etc Blood Group System 4. Dose Depended Antigens (Like Mns, Duffy Etc) Should Be Present In Homozygous As Per Criteria Of Antibody Identification Test 5. Cell Panel Should Contain Rbc With The One Or More Heterozygous Expression Of Dose Dependent Antigens (Mns,Duffy) For Better Interpretation Of Result. 6. Cell Panel Should Be Compatible For Enzyme Treatment 7. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Low Ionic Strength Saline For Glass Bead Cassettes Low Ionic Strength Saline Should Be Compatible For Glass Bead Cassettes For Doing Antibody Screening , Antibody Identification Or Any Other Iat Test. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Note : - 1. Physical Demonstration Of Performance Of Testing Kit(S) :Technically Qualified Bidders Have To Undergo Physical Demonstration Of Performance Of Testing Kit(S) By The Experts Before Being Eligible As Finally Qualified For Financial Bid Opening .The Specific Date & Time Of The Same Will Be Notified Later On. 2. The Participating Bidders Of The Gel Card (Cat No. R06(B)/Kcr & B15(B)/Kcr) Are Requested To Bid For The Respective Diluents Also. If Not Participated In Both Gel Card & Diluents Then The Technical Bid Of The Bidder Will Not Be Evaluated And Will Be Rejected. 3. L1 Bidder Of The Gel Card, Must Accept The L1 Rate Of The Diluents, If Not Achieved L1 Status In The Diluents. Otherwise, The L1 Bidder Of The Diluents Will Be Offered To Accept The L1 Rate Of The Gel Card. 4. Where Rate Per Ml Is Invited, After Finalization Of The Tender Minimum Pack Size Will Be Accepted. 5. Quality Of The Product Supplied / To Be Supplied, May Be Ascertained By Testing / Physical Examination By The Experts At Any Stage Of The Tender Period. 6. The Items Should Be Us Fda/Ce/ Icmr/Nib/Cdsco Approved (Us Fda/ Ce Certificate Will Be Applicable Only When The Indian Standards Like Icmr/Nib/Cdsco Is Not Available). 7. In Case Of Imported Items Nabl/Nib/Niv/Cdl Or Equivalent Authorized Lab Accredited By Parent Country Will Be Considered. 8. If Every Supplied Batch Of The Approved Vendor Contains Test Report From Nib/Niv/Nari/Icmr Then The 2% Testing Charge Will Not Be Deducted From The Bill(S). 9. All Prospective Bidders Are Requested To Quote The Rate In Boq As Per Accounting Unit & Item Specification As Mentioned In The Table-A. Wrong Quoting Of The Rate In Boq Will Be Dealt With As Per Penal Provisions Of The T&C Of The Tender. 10. Tendered Quantity Is Just A Tentative Quantity And Should Not Be Treated As Final. It May Increase Or Decrease, As Per Need Of The State. Keeping This In Mind, The Supplier Is Not Allowed To Seek Termination Of The Rate Contract After Finishing Supply Of Tendered Quantity.

BOQ

Name of Work:- RE E TENDER FOR PROCUREMENT OF KITS, CHEMICALS & REAGENTS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC) AND ITS EXTENSION, IF REQUIRED
Sl. No. Item Description
1Rh +K phenotyping glass bead cassettesTechnical Specification:1.Cassttes should contain 6 columns filled with glass bead as filtration media 2.1st Column to 5th column should be prefilled with monoclonal antisera such as Anti C, Anti E, Anti c, Anti e, Anti K respectively and 6th column is 'control' column. 3.PEG should be present in the columns as enhancer to increase uptake of antibody 4. Assay time should be as per manufacturer's guideline / brochure 5. Mixed field reaction /double cell population should be detected
2AHG poly specific glass bead cassettes Technical Specification:1. Cassettes should contain 6 columns filled with glass beads filtration media 2. All column should prefilled with AHG reagent (Anti IgG , Anti C3d)3. Assay time should be as per manufacturer's guideline / brochure 4. Mixed filled reaction /double cell population should be detected
3Blood Grouping (Forward & reverse grouping) glass bead cassettes Technical Specification: 1. Cassettes should contain 6 columns filled with glass bead as filtration media 2. 1st to 3rd Colums should be prefilled with monoclonal antisera with a serial of Anti A, Anti B, Anti D respectively and rest 3 colums contain 1 for 'control' and 2 colums for reverse grouping with variable serial.3. PEG should be present in the columns as enhancer to increase uptake of antibody 4. Centrifugation time should be as per manufacturer's guideline5. Mixed field reaction /double cell population should be detected
4Monoclonal Antisera for extended Rh+K phenotypingAnti C Technical Specification:Anti C sera should be monoclonal Anti C sera should be compatible for conventional test tube method The potency titre of the antisera should not be less than 4.
5Monoclonal Antisera for extended Rh+K phenotyping Anti cTechnical Specification:Anti c sera should be monoclonalAnti c sera should be compatible for conventional test tube method The potency titre of the antisera should not be less than 4.
6Monoclonal Antisera for extended Rh+K phenotyping Anti E Technical Specification:Anti E sera should be monoclonal Anti E sera should be compatible for conventional test tube method The potency titre of the antisera should not be less than 4.
7Monoclonal Antisera for extended Rh+K phenotyping Anti eTechnical Specification:Anti e sera should be monoclonal Anti e sera should be compatible for conventional test tube method The potency titre of the antisera should not be less than 4.
8Monoclonal Antisera for extended Rh+K phenotyping Anti K (Kell)Technical Specification:Anti K sera should be monoclonal Anti K sera should be compatible for conventional test tube method The potency titre of the antisera should not be less than 4.
9Panel for Antibody 3 cell Screening applicable to Conventional Test Tube method and Glass Bead Cassettes Technical Specification: 1. Cell Panel should be 2%-5% of RBC suspended in saline 2. Cell Panel should be compatible with both conventional test tube method and glass bead cassettes of column agglutination technology for doing antibody screening test3. Cell panel should contain RBC with the antigens of extended Rh, Kell, Duffy, Kidd, Lewis, MNS etc blood group system4. Dose depended antigens (like MNS, Duffy etc) should be present in homozygous as per criteria of antibody screening test 5. Cell panel should be compatible for enzyme treatment 6. Pack size should be as per manufacturer's guideline / brochure
10Panel for Antibody 3 cell Screening applicable to gel card Technical Specification:1.Cell Panel should be 0.8%-1% of RBC suspended in Low ionic strength saline2. Cell Panel should be compatible with gel card of column agglutination technology for doing antibody screening test3. Cell panel should contain RBC with the antigens of extended Rh, Kell, Duffy, Kidd, Lewis, MNS etc blood group system4.Dose depended antigens (like MNS, Duffy etc) should be present in homozygous as per criteria of antibody screening test 5. Cell panel should be compatible for enzyme treatment 6. Pack size should be as per manufacturer's guideline / brochure
11Panel for Antibody 11 cell Identification Test applicable to Conventional Test Tube method and Glass Bead Cassettes Technical Specification:1. Cell Panel should be 2%-5% of RBC suspended in saline 2. Cell Panel should be compatible with both conventional test tube method and glass bead cassettes of column agglutination technology for doing antibody identification test3. Cell panel should contain RBC with the antigens of extended Rh, Kell, Duffy, Kidd, Lewis, MNS etc blood group system4. Dose depended antigens (like MNS, Duffy etc) should be present in homozygous as per criteria of antibody identification test 5. Cell panel should contain RBC with the one or more heterozygous expression of dose dependent antigens (MNS,Duffy) for better interpretation of result.6. Cell panel should be compatible for enzyme treatment 7. Pack size should be as per manufacturer's guideline / brochure
12Panel for Antibody 11 cell Identification Test applicable to Conventional Test Tube method and Glass Bead Cassettes Technical Specification:1. Cell Panel should be 2%-5% of RBC suspended in saline 2. Cell Panel should be compatible with both conventional test tube method and glass bead cassettes of column agglutination technology for doing antibody identification test3. Cell panel should contain RBC with the antigens of extended Rh, Kell, Duffy, Kidd, Lewis, MNS etc blood group system4. Dose depended antigens (like MNS, Duffy etc) should be present in homozygous as per criteria of antibody identification test 5. Cell panel should contain RBC with the one or more heterozygous expression of dose dependent antigens (MNS,Duffy) for better interpretation of result.6. Cell panel should be compatible for enzyme treatment 7. Pack size should be as per manufacturer's guideline / brochure
13Low ionic Strength Saline for Glass bead cassettes Low ionic strength saline should be compatible for glass bead cassettes for doingantibody screening , antibody identification or any other IAT test. Pack size should be as per manufacturer's guideline / brochure
14Note : - 1. Physical Demonstration of performance of Testing kit(s) :Technically qualified bidders have to undergo Physical Demonstration of performance of Testing kit(s) by the Experts before being eligible as finally qualified for financial bid opening .The specific date & time of the same will be notified later on.2. The participating bidders of the Gel Card (Cat No. R06(b)/KCR & B15(b)/KCR) are requested to bid for the respective diluents also. If not participated in both Gel Card & diluents then the technical bid of the bidder will not be evaluated and will be rejected.3. L1 bidder of the Gel card, must accept the L1 rate of the diluents, if not achieved L1 status in the diluents. Otherwise, the L1 bidder of the Diluents will be offered to accept the L1 rate of the Gel Card. 4. Where Rate per ml is invited, after finalization of the tender minimum pack size will be accepted.5. Quality of the product supplied / to be supplied, may be ascertained by testing / physical examination by the experts at any stage of the tender period.6. The Items should be US FDA/CE/ ICMR/NIB/CDSCO approved (US FDA/ CE certificate will be applicable only when the Indian Standards like ICMR/NIB/CDSCO is not available).7. In case of imported items NABL/NIB/NIV/CDL or equivalent authorized Lab accredited by Parent country will be considered.8. If every supplied batch of the approved vendor contains test report from NIB/NIV/NARI/ICMR then the 2% testing charge will not be deducted from the bill(s).9. All prospective bidders are requested to quote the rate in BOQ as per Accounting Unit & item specification as mentioned in the Table-A. Wrong Quoting of the rate in BOQ will be dealt with as per penal provisions of the T&C of the Tender.10. Tendered quantity is just a tentative quantity and should not be treated as final. It may increase or decrease, as per need of the state. Keeping this in mind, the supplier is not allowed to seek termination of the Rate Contract after finishing supply of tendered quantity. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56455262
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 07-08-2026
Authority
Authority Name Health And Family Welfare Department
Work Description Tender for Re E Tender For Procurement Of Kits, Chemicals & Reagents For Two Years From The Date Of Award Of Contract (Aoc) And Its Extension, If Required , Rh +K Phenotyping Glass Bead Cassettes Technical Specification: 1.Cassttes Should Contain 6 Columns Filled With Glass Bead As Filtration Media 2.1St Column To 5Th Column Should Be Prefilled With Monoclonal Antisera Such As Anti C, Anti E, Anti C, Anti E, Anti K Respectively And 6Th Column Is Control Column. 3.Peg Should Be Present In The Columns As Enhancer To Increase Uptake Of Antibody 4. Assay Time Should Be As Per Manufacturers Guideline / Brochure 5. Mixed Field Reaction /Double Cell Population Should Be Detected , Ahg Poly Specific Glass Bead Cassettes Technical Specification: 1. Cassettes Should Contain 6 Columns Filled With Glass Beads Filtration Media 2. All Column Should Prefilled With Ahg Reagent (Anti Igg , Anti C3d) 3. Assay Time Should Be As Per Manufacturers Guideline / Brochure 4. Mixed Filled Reaction /Double Cell Population Should Be Detected , Blood Grouping (Forward & Reverse Grouping) Glass Bead Cassettes Technical Specification: 1. Cassettes Should Contain 6 Columns Filled With Glass Bead As Filtration Media 2. 1St To 3Rd Colums Should Be Prefilled With Monoclonal Antisera With A Serial Of Anti A, Anti B, Anti D Respectively And Rest 3 Colums Contain 1 For Control And 2 Colums For Reverse Grouping With Variable Serial. 3. Peg Should Be Present In The Columns As Enhancer To Increase Uptake Of Antibody 4. Centrifugation Time Should Be As Per Manufacturers Guideline 5. Mixed Field Reaction /Double Cell Population Should Be Detected , Monoclonal Antisera For Extended Rh+K Phenotyping Anti C Technical Specification: Anti C Sera Should Be Monoclonal Anti C Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Monoclonal Antisera For Extended Rh+K Phenotyping Anti C Technical Specification: Anti C Sera Should Be Monoclonal Anti C Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Monoclonal Antisera For Extended Rh+K Phenotyping Anti E Technical Specification: Anti E Sera Should Be Monoclonal Anti E Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Monoclonal Antisera For Extended Rh+K Phenotyping Anti E Technical Specification: Anti E Sera Should Be Monoclonal Anti E Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Monoclonal Antisera For Extended Rh+K Phenotyping Anti K (Kell) Technical Specification: Anti K Sera Should Be Monoclonal Anti K Sera Should Be Compatible For Conventional Test Tube Method The Potency Titre Of The Antisera Should Not Be Less Than 4. , Panel For Antibody 3 Cell Screening Applicable To Conventional Test Tube Method And Glass Bead Cassettes Technical Specification: 1. Cell Panel Should Be 2%-5% Of Rbc Suspended In Saline 2. Cell Panel Should Be Compatible With Both Conventional Test Tube Method And Glass Bead Cassettes Of Column Agglutination Technology For Doing Antibody Screening Test 3. Cell Panel Should Contain Rbc With The Antigens Of Extended Rh, Kell, Duffy, Kidd, Lewis, Mns Etc Blood Group System 4. Dose Depended Antigens (Like Mns, Duffy Etc) Should Be Present In Homozygous As Per Criteria Of Antibody Screening Test 5. Cell Panel Should Be Compatible For Enzyme Treatment 6. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Panel For Antibody 3 Cell Screening Applicable To Gel Card Technical Specification: 1.Cell Panel Should Be 0.8%-1% Of Rbc Suspended In Low Ionic Strength Saline 2. Cell Panel Should Be Compatible With Gel Card Of Column Agglutination Technology For Doing Antibody Screening Test 3. Cell Panel Should Contain Rbc With The Antigens Of Extended Rh, Kell, Duffy, Kidd, Lewis, Mns Etc Blood Group System 4.Dose Depended Antigens (Like Mns, Duffy Etc) Should Be Present In Homozygous As Per Criteria Of Antibody Screening Test 5. Cell Panel Should Be Compatible For Enzyme Treatment 6. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Panel For Antibody 11 Cell Identification Test Applicable To Conventional Test Tube Method And Glass Bead Cassettes Technical Specification: 1. Cell Panel Should Be 2%-5% Of Rbc Suspended In Saline 2. Cell Panel Should Be Compatible With Both Conventional Test Tube Method And Glass Bead Cassettes Of Column Agglutination Technology For Doing Antibody Identification Test 3. Cell Panel Should Contain Rbc With The Antigens Of Extended Rh, Kell, Duffy, Kidd, Lewis, Mns Etc Blood Group System 4. Dose Depended Antigens (Like Mns, Duffy Etc) Should Be Present In Homozygous As Per Criteria Of Antibody Identification Test 5. Cell Panel Should Contain Rbc With The One Or More Heterozygous Expression Of Dose Dependent Antigens (Mns,Duffy) For Better Interpretation Of Result. 6. Cell Panel Should Be Compatible For Enzyme Treatment 7. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Panel For Antibody 11 Cell Identification Test Applicable To Conventional Test Tube Method And Glass Bead Cassettes Technical Specification: 1. Cell Panel Should Be 2%-5% Of Rbc Suspended In Saline 2. Cell Panel Should Be Compatible With Both Conventional Test Tube Method And Glass Bead Cassettes Of Column Agglutination Technology For Doing Antibody Identification Test 3. Cell Panel Should Contain Rbc With The Antigens Of Extended Rh, Kell, Duffy, Kidd, Lewis, Mns Etc Blood Group System 4. Dose Depended Antigens (Like Mns, Duffy Etc) Should Be Present In Homozygous As Per Criteria Of Antibody Identification Test 5. Cell Panel Should Contain Rbc With The One Or More Heterozygous Expression Of Dose Dependent Antigens (Mns,Duffy) For Better Interpretation Of Result. 6. Cell Panel Should Be Compatible For Enzyme Treatment 7. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Low Ionic Strength Saline For Glass Bead Cassettes Low Ionic Strength Saline Should Be Compatible For Glass Bead Cassettes For Doing Antibody Screening , Antibody Identification Or Any Other Iat Test. Pack Size Should Be As Per Manufacturers Guideline / Brochure , Note : - 1. Physical Demonstration Of Performance Of Testing Kit(S) :Technically Qualified Bidders Have To Undergo Physical Demonstration Of Performance Of Testing Kit(S) By The Experts Before Being Eligible As Finally Qualified For Financial Bid Opening .The Specific Date & Time Of The Same Will Be Notified Later On. 2. The Participating Bidders Of The Gel Card (Cat No. R06(B)/Kcr & B15(B)/Kcr) Are Requested To Bid For The Respective Diluents Also. If Not Participated In Both Gel Card & Diluents Then The Technical Bid Of The Bidder Will Not Be Evaluated And Will Be Rejected. 3. L1 Bidder Of The Gel Card, Must Accept The L1 Rate Of The Diluents, If Not Achieved L1 Status In The Diluents. Otherwise, The L1 Bidder Of The Diluents Will Be Offered To Accept The L1 Rate Of The Gel Card. 4. Where Rate Per Ml Is Invited, After Finalization Of The Tender Minimum Pack Size Will Be Accepted. 5. Quality Of The Product Supplied / To Be Supplied, May Be Ascertained By Testing / Physical Examination By The Experts At Any Stage Of The Tender Period. 6. The Items Should Be Us Fda/Ce/ Icmr/Nib/Cdsco Approved (Us Fda/ Ce Certificate Will Be Applicable Only When The Indian Standards Like Icmr/Nib/Cdsco Is Not Available). 7. In Case Of Imported Items Nabl/Nib/Niv/Cdl Or Equivalent Authorized Lab Accredited By Parent Country Will Be Considered. 8. If Every Supplied Batch Of The Approved Vendor Contains Test Report From Nib/Niv/Nari/Icmr Then The 2% Testing Charge Will Not Be Deducted From The Bill(S). 9. All Prospective Bidders Are Requested To Quote The Rate In Boq As Per Accounting Unit & Item Specification As Mentioned In The Table-A. Wrong Quoting Of The Rate In Boq Will Be Dealt With As Per Penal Provisions Of The T&C Of The Tender. 10. Tendered Quantity Is Just A Tentative Quantity And Should Not Be Treated As Final. It May Increase Or Decrease, As Per Need Of The State. Keeping This In Mind, The Supplier Is Not Allowed To Seek Termination Of The Rate Contract After Finishing Supply Of Tendered Quantity.
Basic Detail
Tender No WBHF/CMS/ HST/4T-131-2026/ KITS-RT(396)/2026/401
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 14 Jul 2026
Submission Date 07 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1 Lakhs
Exemption Available
Document List
bd9df207-1a6e-44bf-b5a8-53e186552d68.html
BOQ_2535447.xls
Technical_Data_Sheet_401.xls
Tendernotice_1 (15).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

bd9df207-1a6e-44bf-b5a8-53e186552d68.html

xls

BOQ_2535447.xls

xls

Technical_Data_Sheet_401.xls

pdf

Tendernotice_1 (15).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders