Public Administrative Department Local Bodies Closing in 6 days TDR #56454274

Tender For Major Repair Work M.C. Primary Co-Ed School, Anguri Khirki (School Fans, Switch Board & Tube Lights Etc )

Issued by Local Bodies · Delhi, Delhi
Tender Value
6.78 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
6 days left
EMD
13978
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Major Repair Work M.C. Primary Co-Ed School, Anguri Khirki (School Fans, Switch Board & Tube Lights Etc )

BOQ

Name of Work:- Major Repair Work M.C. Primary Co-ed School, Anguri Khirki (School Fans, Switch Board & Tube Lights etc )
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
3Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
4(a) 200 mm X 300 mm X 100 mm deep
5Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
6(a)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
7(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
8(c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
9Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)) (A) 6 Way Double door
10Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. . (A) 20 mm
11Supplying and fixing 5amps,to 32 amps rating, 240 volts, \\"C\\" curve miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc, as required. (A) Single Pole
12Supply and fixing following rating, double pole, 240 volt, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. (A) 40 amps
13Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1 kv grade of following size in the existing surface as required
14(A)Upto 35 sq. mm (clamped with 1mm thick saddle)
15Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt
16Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 150Watt
17Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
18(a)5/6amps switch
19(b)15/16 amps switch
20(c)3 pin 5/6 amps socket outlet
21(d) 6 pin 15/16 amps socket outlet
22Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
23Supply & Fixing of phenolic laminated 3 mm thick sheet i/c cutting as reqd.
24Providing and fixing following rating and breakingcapacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
25(a)100 Amp, 16KA TPMCCB
26(b)125 Amp, 16KA TPMCCB
27Supply of PVC/XLPE insulated PVC/XLPE sheathed Al. conductor armoured cable for working voltage up to 1.1 kv confirming to IS 7098(part-1) of following size
28(a) 2 X6 sqmm
29Rewinding of AC ceiling fan of all sizes and make including oiling, greasing as required. Old Model (Heavy Weight)
30Replacement of ball bearing of size 117/120 NBC equivalent SKF make as required.
31Replacement of fan condenser 2.5 mfd as required.
32Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
333 Module (100mmX75mm
344 Module (125mmX75mm)
356 Module (200mmX75mm)
368 Module (125mmX125mm)
3712 Module (200mmX150mm) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56454274
AUTHORITY Local Bodies
TENDER VALUE 6.78 Lakhs
LAST DATE 22-07-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Major Repair Work M.C. Primary Co-Ed School, Anguri Khirki (School Fans, Switch Board & Tube Lights Etc )
Basic Detail
Tender No 15/MWEEE-I/2026-27/TC
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 14 Jul 2026
Submission Date 22 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value 6.78 Lakhs
Tender Fee 590
EMD 13978
Exemption Not Available
Document List
abb8c548-e5ad-411a-9988-b091b1ea54df.html
BOQ_331360.xls
DNIT01_0001.pdf
Tendernotice_1.pdf
Tendernotice_2 (1).pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

abb8c548-e5ad-411a-9988-b091b1ea54df.html

xls

BOQ_331360.xls

pdf

DNIT01_0001.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (1).pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders