Housing Urban and Rular Development Government Departments Closing in 7 days TDR #56452581

Tender For Construction Of Laboratory (G+1) At Kvk, Sambalpur.

Issued by Government Departments · Sambalpur, Odisha
Tender Value
1.23 Crore
Estimated cost
Bid Submission
29 Jul 2026
7 days left
EMD
1.23 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sambalpur → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Laboratory (G+1) At Kvk, Sambalpur.

BOQ

Name of Work:- CONSTRUCTION OF LABORATORY (G+1) AT KVK, SAMBALPUR.
Sl. No. Item Description
1Earth work in excavation of foundation trenches in all type of soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge.
2Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). as per the specification and direction of Engineer-in-charge. Ground FLoor
3Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties, of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge. Ground FLoor
4Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, and royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge
5R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. Ground FLoor
6Column base Footing
7Plinth Band
8Column superstructure
9First Floor
10Second Floor
11Lintel Bend
12First FLoor
13Chajja
14First FLoor
15Second Floor
16Staircase
17First FLoor
18Roof Beam
19First FLoor
20Second Floor
21Roof slab
22First Floor
23Second Floor
24Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / TATA / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. Ground FLoor
25First Floor
26Second Floor
27Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-charge. Ground FLoor
28First Floor
29Second Floor
30Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
31First Floor
32Second Floor
33Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
34First Floor
35Second Floor
36Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
37First Floor
38Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\"x2'0\\" with 12mm thick Prelaminated Particle Board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge
39Fixing chequred tile in floor on 20mm thick bed (1:4) c.m.jointed with cement slusy mixed with pigment to match the shade of the tiles including rubbing & polishing complete including cost of tiles.
40Supplying, fitting and fixing tiles in floors of size 600mm x 600mm of approved make confirming to IS 13755 laid on 20 mm thick cement mortar (1:4) (1 cement:4 course sand) and filling joints with white cement of approved qualiy including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge. Ground FLoor(For new work only)
41First Floor
42Supplying, fitting & fixing of Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 13755 of size 60cm x 60cm coloured/printed series in dadoes, skirting and risers of steps of laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. Ground FLoor
43First Floor
44Supplying, fitting & fixing granite tile (Above 0.40 Sqm) (20mm thick) in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including machine polishing to edge moulding to give high gloss finish including making three nos of groove over tread etc. complete including cost, coveyance, loading and unloading and ,es of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge.
45First Floor
46Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. of approved make in dadoes laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including machine polishing to edge moulding to give high gloss finish including making three nos of groove over tread etc. complete including cost, coveyance, loading and unloading and ,es of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge.
47First Floor
48Supplying, fitting and fixing in position well dressed and well seasoned sal wood work framed and fixed (wrought and put up) in choukaths for doors, windows and ventilators including cost of iron works and coaltaring 2 coats to the wall side faces of choukaths including cost of coal tar, cutting grooves and mending sizes where necessary with cost and conveyance, royalties and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors.
49Supplying fitting & fixing of 32mm thick flush door shutters with flush door block board 'A' premium 32mm thick both side teak (Green ply / Allwin) both side laminated with 4 mm thick veener board (Teak Heritage) (Archid ply/ Green ply ) by using adhesives, with all labour, iron fitting & wooden hinged cleats etc. fitted & fixed complete in all respect, including cost of iron fitting , alluminum fittings, all labours, T&P etc. as per specification approved by the Department & as per direction of the E.I.C.
50Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
51Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-charge. Ground FLoor
52Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. Ground FLoor
53Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.
54First Floor
55Second Floor
56Finishing wall surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground FLoor
57First Floor
58Second Floor
59Priming 1 coat with wall primer water bond cement primer of approved make & approved shade to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. Ground FLoor
60First Floor
61Second Floor
62Painting two coats with plastic emulsion paint of approved make & approved shade to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. Ground FLoor
63First Floor
64Second Floor
65Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground FLoor
66First Floor
67Second Floor
68Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. Ground FLoor
69ELECTRICAL WORKSub-Head I (modular Wiring Items)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
70GROUP-A
71GROUP-B
72GROUP-C
73Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
74Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
75Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
76Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)(FLAME retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
77Supplying,fixing of 6A Plug on the separate board with complete fitting by 2X 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
78Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5)
79Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5)
80Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit (2X4+1X1.5)
81Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit . (2X6+1X2.5)
82Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit (4X6+2X4)
83Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
84Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
85Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
86S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
87S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
88Sub-Head II (Light fitting Fixture & Fan)
89Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
90Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
91Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.
92Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of 2 ftsx2fts CRCA powder coated sheet steel of 25W (595mmx595mmx70mm)and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years.
93Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
94SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
95SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
96Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
97BDBS,DB,AC DB,FLOOR PANELS,MCBS
98Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years
994 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
100Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
1012+4 way MCB Enclosure DB (GLAZED door)Warranty on DB is 3 years
1028 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD)Warranty on DB is 3 years
103Supplying and fixing 20 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years.
104Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years.
105Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years..
106Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 4P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 /ABB FB 200in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 1 years.
107Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1 years.
108Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 1years.
109(Earthing) INSTALLATION
110Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. Ground FLoor
111Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
112Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
113CABLING AND END TERMINATION MAIN AREA
114Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade (make-Polycab/ RR/ Finolex/ Havells/ KEI/ Gloster ) of following size cables as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
1153.5core x 50 sq mm 2 runs for main
1164core x 16 sq mm
1174 core x 6 sq mm
118LAYING OF CABLE
119Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
120Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
121Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
122Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
123Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge.
124Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
125Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
126Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
127Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
128Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
1294 core x16sq mm
1303.5 core x50 sq mm
131Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
13250 mm dia
133Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
134200 mm dia
135S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.. 2 nos of 3P+N Type 1+2 SPD65kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer.
136In commer - 125A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula
137Busbar-1&2 04 numbers of 150Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)
138outgoing - 2 nos 63A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula
139Out going- 0 nos 63A 4P MCB 10kA,C series for power BDB. (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200)
140Out going- 01 nos 40A 4P MCB 10kA,C series for light BDB. (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200)
141Out going- 03 nos 32A 2P MCB 10kA,C series for power BDB. (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200)
142Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.
143(ii) 02 set of digital type multifunction meter r(Make-Siemens/Schneider/ABB/Secure) with CT CTs 100/5A 4 nos, 40/5A, class 1 type(Make-KAPPA /AE)for voltage,current,frequency,PF,THD indication.
144CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
145Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
146PUMPS AND APPURTENANCES
147Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.(Make:PUMP:KBL/ Grundfos / KSB/ Wilo)
148Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make-Legrand/schneider/Siemens/ABB
1491100 V GRADE POWER/CONTROL CABLES :SITC of FRLS,PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge.Make-Polycab/Havells/KEI/Finolex/RR Kabel /Gloster 4C x 16 mmsq
1501100 V GRADE POWER/CONTROL CABLES :SITC of FRLS,PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge.Make-Polycab/Havells/KEI/Finolex/RR Kabel /Gloster .Size-2 C x 1.5 mmsq
151PIPE & VALVES ETC.
152Supply,Installation,Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 100 mm NB and IS 3589 for above 100 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge.Make-TATA/JINDAL/SAIL
153100mm NB
15480mm NB
155Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C. Make-Zoloto/AUDCO/Leader
156100mm NB
157Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Ground FLoor Make-Zoloto/AUDCO/Leader
158100mm NB
159Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge. Ground FLoorMake-H.Guru/G.Guru
160Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge. Ground FLoorMake-Danfoss/Indfoss/Grundfoss
161Supply,Installation,Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/AUDCO/Leader
162100mm NB
163DOWN COMER SYSTEM
164Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge. Ground FLoorMake-Minimax/Newage/Fireshield/Safex
165Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge. Ground FLoor Make-Minimax/Newage/Fireshield/Safex
166Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge. Ground FLoor Make-Minimax/Newage/Fireshield/Safex
167Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge. Ground FLoor Make-Minimax/Newage/Fireshield/Safex
168Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge. Ground FLoor Make-Minimax/Newage/Fireshield/Safex
169Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge. Ground FLoor
170Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Zoloto/Karatr/Kirloskar
171EXTINGUISHER SYSTEM
172Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories Make-Morley IAS/Siemens/Bosch/Edward/NOTIFIER
173Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories Make-Morley IAS/Siemens/Bosch/Edward/NOTIFIER
174Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket.
175SIGNAGES
176SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj
177Illumination Glow light for Exit Indication with Battery Back-up.
178SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
179SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
180SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
181SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
182SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length)
183SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length)
184SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
185SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
186SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
187SITC of 10G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear
188SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP
189SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
190SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand
191Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak
19220 MM
19325 MM
194Sub Total A (Excluding GST)
195Subhead- 1.a (IP-PBX System)
196Supplying and fixing of Hybrid EPABX system equipped with 20 Analog extensions and 6 Analog Trunk, including required hardware and software etc as reqd. Make-Matrix/Siemens/Coral
197Supplying desktop telephone sets with colour ID as reqd Make-Panasonic/Beetel
198S/f of 50 pair MDF box with 3 nos. krone module.
199S/f of 5O pair krone box with k2 no. krone module
200Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the surface/ recessed steel/ PVC conduit as required.
2012 Pair
20220 Pair
203S/F DP box suitable for above as reqd
204Sub Total B (Excluding GST)
205Subhead- 3 (IP-CCTV System)
206Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA/STQC compliant. Make-Honeywell(Series 35), Pelco, Axis
207Supply , Installation, testing , commissioning of 32 Channel NVR with 4 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).STQC compliant Make-Honeywell series 35/Pelco/Axis
208Supply & Installation 10 TB Surveillence Hardisk.Make: Seagate/WD/Toshiba
209SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
210Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent
211Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent
212Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent
213Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB/Equivalent
214Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn
215Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn
216Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB/Equivalent
217Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB/Equivalent
218Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent
219Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB/Equivalent
220Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent
221Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent
222Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent
223Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB/Equivalent
224Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB/Equivalent
225Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB/Equivalent
226Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB/Equivalent
227Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB/Equivalent
228Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
229S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic coverPanasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj (5Years Warranty)
230Supply of 6 mtr long hot dip Galvanized PU Painted Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge.
231Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge.
232Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge.
233Supplying, Erection, Fixing, connection & testing of 45W LED Heritage GATE Light,IP 66,IK07,amb. temp -10 to 45 degree celcious,CT 3000-5700K,,50000 HRS,CRI 70,4500 lumens,driver efficiency >/ 85%,dia case aliminium housing,polycarbonet defuser with lens of Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj as approved maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
234Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. Ground FLoor
235Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
236S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials
237Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Make- POLYCAB/KEI/HAVELLS /GLOSTER/FINOLEX/RR KABEL
238Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
239P.H WORKSupplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS: 15778 and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge
240Ground Floor
24125mm dia C-PVC ASTM pipe (sch-80)
24232mm dia C-PVC ASTM pipe (sch-80)
243First Floor
24425mm dia C-PVC ASTM pipe (sch-80)
24532mm dia CPVC ASTM pipe (sch-80)
24640mm dia CPVC ASTM pipe (sch-80)
247Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. Ground FLoor
24815mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)
24915mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)
25015mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
25115mm dia CP Bib cock (Con-CHR-047KN Jaquar make)
25215mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
25325mm dia brass full way valve (Shakti make)
25432mm dia brass full way valve (Shakti make)
25540mm dia brass full way valve (Shakti make)
25615mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
257125mm CP grating
25815mm size C.P. flange
259Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge
2602000 liters capacity PVC water storage tank
261supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. Ground FLoor
262Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge
263Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. Ground FLoor
264Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. Ground FLoor
265110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B)
266110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make)
267110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
268110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
269110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
270110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
271110mm U-PVC HR Bend(Ori Plast/Finolex/Supreme Make)
272110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)
273110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
274110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
275110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)
276110mm U-PVC Plain shoe bend(Ori Plast/Finolex/Supreme Make)
277110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
278Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. Ground FLoor
279580mm size Orissa pan (Hindware/Parryware/Neycer make)
280Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge
28110 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
282Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal
283Supplying all materials, labour, T&P and fixing vitreous china water closet,European wc) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. Ground FLoor
284European water closet (Hindware/Parryware/Neycer make)
285Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge
286550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with
287Counter basin(560x450)Hindware-No.10095
288Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
28925mmx600mm long CP towel rail
290Towel ring
291Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.
292600mmx125mm plate glass shelf with CP/NP guard rails.
293Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.
294600mmx450mm size B.E mirror (swivelled type)
295Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
296Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge
297Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
298Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.
299Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
300Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge )
301Kajaria tile 60cmx60cm Ground Floor
302Kajaria tile 60cmx60cm First Floor
303Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. Ground FLoor
304Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge )
305Kajaria tile 30cmx60cm Ground Floor
306Kajaria tile 30cmx60cm First Floor
307Granite
308Providing fitting, fixing of Aluminium door with anodized AL. door section of 9202 as vertical member,9201 as top and 9200 as middle bottom member with frame section No. 9221 and tapered clip no. 4660 and the frame to be completed by means of jointing angle No. 1855 Including all Cost of Labour. T&P hire charges of drilling machine. labour charges etc. complete. Ref : OBI10
309Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 40 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 40 liter's along with noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge
310Aqua guard pure Chill 40 PSS UV
311Ext. S/D Portion
312Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge
313100mm dia P.V.C. pipe
314150mm dia P.V.C. pipe
315Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification.
316MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover )
317Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
31830 USERS SEPTIC TANK
319Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. 1 x 4.70 x 3.30m x 0. 70
320Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. 1 x 4.70 x 2.30m x 0.15 =
321Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC.
322Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete.
323Supplying all labor T&P &Providing C.C. (1:2:4) with 12mm size broken hard granite chips including watering curing & lead of all materials to site etc. all complete.
324Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site.
325Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. 1.013cum x 2,5 x 35.32 =89.44 say Rs-
326Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor.
327Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site.
328Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site.
329Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site.same as plastering
330Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification.
331Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge.
332Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. Ground FLoor
333Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories
334Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
335Drilling of 200mm dia bore
33600 mtr to 30mtr
33730 mtr to 45mtr
338Drilling of 150mm dia bore
33945 mtr to 175
340Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.
341200mm dia PVC pipe
34200 mtr to 45 mtrs
343Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.
344200mm dia PVC (sch-80) pipe
345Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department)
346Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
347By DTH Rig
348Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:
349Rocky terrain with boulder formation for 300m depth
350Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)
3511.5 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm
352DOL Control panel
35340mm dia steel short piece
354Well cap
35550mm size CI bracket
3562.50sqmm flat cable
357Steel rope with cover
358Labour charges for lowering including transportation
359Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge
36032mm HDPE pipes (Finolex/Supreme make) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56452581
AUTHORITY Government Departments
TENDER VALUE 1.23 Crore
LAST DATE 29-07-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Construction Of Laboratory (G+1) At Kvk, Sambalpur.
Basic Detail
Tender No CCENC(RANDB) /25/ 2025-26
Bidding Type Tender
Location
City Sambalpur
State Odisha
Key Dates
Publish Date 14 Jul 2026
Submission Date 29 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 1.23 Crore
Tender Fee 10000
EMD 1.23 Lakhs
Exemption Available
Document List
10KVK.pdf
63fcfa54-b49c-4319-894c-4563527c8601.html
BOQ_601395.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

10KVK.pdf

html

63fcfa54-b49c-4319-894c-4563527c8601.html

xls

BOQ_601395.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders