Housing Urban and Rular Development Government Departments Closing in 0 days TDR #56452572

Tender For Construction Of Court Building At Bijepur

Issued by Government Departments · Bargarh, Odisha
Tender Value
7.19 Crore
Estimated cost
Bid Submission
29 Jul 2026
0 days left
EMD
7.19 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bargarh → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Court Building At Bijepur

BOQ

Name of Work:- CONSTRUCTION OF COURT BUILDING AT BIJEPUR
Sl. No. Item Description
1Earth work in excavation of foundation trenches in all type of soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge.
2Supplying, filling in foundation and plinth with sand in 22.5 cm (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete (Measurement will be taken on finished compacted section only). as per the specification and direction of Engineer-in-charge. Ground FLoor
3Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard hand broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties, taxes of all materials and cost of all labours, T&P etc complete as per the direction of the Engineer -in-charge.
4Cement Concrete (1:2:4) using 12mm size hard granite C.B. chips approved quality from approved quarry black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-charge. Ground FLoor
5Providing and lying plain cement concrete of proportion (1:4:8) in foundation and floors using Portland slag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-charge. Ground FLoor
6Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
7RCC work M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 N. / Square mm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using 12 mm. to 20 mm. size black hard crusher broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20 mm. size chips not to exceed 25 % ) to be mixed in concrete mixture with approved grade cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centring and shuttering and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P, required for the work etc. complete in all respect but excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel tying the grills and placing in proper position as per direction of the Engineer in charge
8A)COLOUM BASE FOOTING
9B)COLUMN SUPER STRUCTURE
10HEAD ROOM(FIRST FLOOR)
11C) PLINTH BAND
12D) LINTEL BAND
13E)ROOF BEAM
14HEAD ROOM(FIRST FLOOR)
15F) CHAJJA
16HEAD ROOM(FIRST FLOOR)
17G) STAIRCASE 1
18J) ROOF SLAB
19HEAD ROOM(FIRST FLOOR)
20Straightening bent up or coiled M.S. rod or HYSD steel (Fe-415 / Fe-500), cutting, bending, cranking, hooking, welding or jointing (if required), the M.S. rod or HYSD steel and binding, tying the grills, hoisting, lowering and placing in proper position as per drawing & design required for R.C.C. works including cost, conveyance and taxes of M.S. rod or HYSD steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete as per approved drawing and technical specification and as per clause-1600 of MoSRTH specification for road & bridge works (Latest Revision ) complete in all respect as directed by Engineer-in-charge. Ground FLoor(weight of binding wires will not be considered for payment and payment will be made on weight of M.S. rod or HYSD steel only. Steel bars of only MAJOR INTEGRATED STEEL PLANTS like SAIL, RINL, TATA, JINDAL & SHYAM STEEL, etc. of Fe-415 / Fe-500 grade are to be used in the work & if required original bill of . steel has to be produced by the contractor)
21HEAD ROOM
22First class Fly ash Brick masonry using bricks of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. Ground FLoor
23Fly Ash. brick masonry of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:6) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge
24HEAD ROOM
25Fly Ash. brick masonry of size 23 cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per Sqr. Cm. in cement mortar of mix (1:4) with approved grade cement and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Superstructure including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge
26Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
27HEAD ROOM
28Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
29HEAD ROOM
30Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
31HEAD ROOM
32Supplying, fitting & fixing of Vitrified floor tiles of premium grade having thickness 8mm to 10mm confirming to IS 13755 of sizes. 60cm x 60cm coloured/printed series laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )
33Supplying, fitting and fixing industrial vitrified tile in floors of approved make conformaing to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only )
34Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Plain (Ivory) of approved make as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects.
35Fixing granite tile (Above 0.40 Sqm) (20mm thick) in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including machine polishing to edge moulding to give high gloss finish including making three nos of groove over tread etc. complete including cost, coveyance, loading and unloading and ,es of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge.
36Priming 1 coat with wall primer water bond cement primer of approved make & approved shade to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. Ground FLoor
37HEAD ROOM
38Finishing wall surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground FLoor
39Wall Painting two coats with approved Distemper of approved make & approved shade to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. Ground FLoor
40Head room
41Painting two coats with plastic emulsion paint of approved make & approved shade to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. Ground FLoor
42Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground FLoor
43HEAD ROOM
44Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-charge. Ground FLoor
45Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @0.90mtr. C/C and stainless square pipe barracking of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.
46Supplying fitting & fixing of 32mm thick flush door shutters with flush door block board 'A' premium 32mm thick both side teak (Green ply / Allwin) both side laminated with 4 mm thick veener board (Teak Heritage) (Archid ply/ Green ply ) by using adhesives, with all labour, iron fitting & wooden hinged cleats etc. fitted & fixed complete in all respect, including cost of iron fitting , alluminum fittings, all labours, T&P etc. as per specification approved by the Department & as per direction of the E.I.C.
47Supplying, fitting and fixing in position well dressed and well seasoned sal wood work framed and fixed (wrought and put up) in choukaths for doors, windows and ventilators including cost of iron works and coaltaring 2 coats to the wall side faces of choukaths including cost of coal tar, cutting grooves and mending sizes where necessary with cost and conveyance, royalties and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors.
48Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
49Supplying, fitting, fixing up window (sliding type) made up aluminum Section 151-154, 151-155, as windows frame section No. 151- 155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-incharge.
50Supplying fitting fixing 5mm thick Black glass including cost of materials all taxes labour, T&P etc. complete as per direction of Engineer-incharge.
51Painting two coats with any approved synthetic enamel paint of approved quality shade and make over a coat of Red Oxide priming to new wood work / iron work including cost of the primer and paint, sand papering polishing the surface with cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect.
52HEAD ROOM
53Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures. 25.17 New Miscellaneous Items-14 page 235 of S/R -2022
54Supplying and fixing of Elastomeric Membrane of 200mm x 2mm size for expansion joint sealing from approved manuefacturer, fixing with epoxy adhesive of approved quality complete.
552.5cm (1”) av. thick grading concrete (1:2:2) using 6mm size black hard crusher broken granite chips over roof slab after chipping and chiseling the same and cleaning the surface by brushing laid to proper slope finished smooth to receive tarfelt treatment watering and curing including cost, conveyance, royalties and taxes of all materials with all labour and T&P etc. required for the work complete in all respect in all floors.
56Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.
57Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018.
58R.C.C. work of Grade-M20 in Drain works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including hoisting, lowering, laying and compacting concrete, watering and curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour and T&P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position.
59BASE SLAB
60SIDE WALL
61COVER SLAB
62Construction of embankment with approved materials obtained from borrow pits with all leads transportation to required slope & compacting by mechanical means spreading, grading to required slope & compacting to meet requirement as per approved drawing and technical specifications complete in all respect as per Section 900 and clause 305 of MoRT&H Specification for Road & Bridge works (latest revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-charge. Ground FLoor
63Construction of Granular Sub-base Grading VI stone screaning materials, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, as per approved Drawing & Technical Specifications and as per Clause - 401 of MoRT&H Specifications for Road & Bridge works (5th Revision) including cost, conveyance, royality & other taxes of materials, cost of labour, machinery, T&P etc complete.
64E.I WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge.Raw power switch board shall be separate from emergency power switch board. UPS DB shall have provision of all computer boards, 1no. of light in every room and alternate lights in the corridor area. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group-A
65Group-B
66Group-C
67Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider (Zencelo)/ legrand( Myrius) / Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
68Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider (Zencelo)/ legrand( Myrius) / Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
69Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
70Supplying,fixing of 2x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+2 nos 6A switch & socket(modular type) (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ Legrand (Myrius-)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
71SUBMAIN.
72Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic HMS FRLS PVC conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
732 X 2.5 sq.mm +1 X 1.5 sq.mm -do- (BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT )
742 X 4 sq.mm +1 X 1.5 sq.mm -do- (PDB to PSB/ POWER POINT/AC POINT)
752 X 6 sq.mm +1 X 2.5 sq.mm -do- (LFDB TO LBDB/UBDB)
762 X 10 sq.mm +1 X 4 sq.mm -do- (LFDB TO LBDB/UBDB)
774 X 10 sq.mm + 2 X 6 sq.mm -do- (LFDB TO FLOOR PANEL TO TPN BDB power) (for AC Power TPN DB)
78Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
79Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
80S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
81S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision))
82FIXTURE
83Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
84Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(Regulator compatible)
85Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
86Supplying an fixing of recess/surface mounted 2'x2' 36 W square(595x595x70mm) shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years.
87SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
88S/F of 10W LED Bulb including all connections and accessories with 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj category ISI marked as per direction Engineer-In-charge
89S/F. of pressure die-cast alluminium 120Wt. LED Street (120 lm/w) light fittings with IP PC Lens, IP66 protection, IK 07 complete with G.I. bracket. The replacement warranty shall be 5 years.Of Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj
90Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 5 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. Warrantied for a period of 5 years
91AC Machine
92Supply,installation, testing and commisioning of 2.0 TR high wall 5 star inverter type split A.C machine (BTU/Hr-21000-24000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi)
931.5 TR high wall 5 star inverter type split A.C machine (BTU/Hr-18000)with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make: (Make:O-General/Diakin/Mitsubishi/Hitachi)
94S/F of 4KVA Voltage stabilizer (90V - 300V) ISI Marked. (Make:- V-Guard/MICRO-TECH).
95S/F of 5KVA Voltage stabilizer (90V - 300V) ISI Marked. (Make:- V-Guard/MICRO-TECH).
96S/F of 3pin 15A top for AC machine (Legrand/Siemens/Schneider)
97Supply,installation of hard/soft copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.
98Supply,installation & fabrication of Insulated drain water piping from indoor to nearest drain point separate to all and other nesessary material to complete the job. 25mm nom. Dia pipe
99Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C
100CABLE .
101Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
1023.5core 150 sq.mm (2 run from Sub-station to Main Panel)
1033.5core 95 sq.mm (2 run from Main Panel to DG)
1043.5core 70 sq.mm (2 run from DG)
1053.5core 35 sq.mm (for external pump room & other)
1064 core 16 sq.mm ((for external Light/Security room & other)
107Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
108Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
109Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct within required size of HDPE Pipe in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required.
110Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
111END TERMINATION
112Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
1133.5C x 150 sq.mm
1143.5C x 95 sq.mm
1153.5C x 70 sq.mm
1163.5C x 35 sq.mm
1174C x 16 sq.mm
118Earthing
119Supply anf fixing of copper plate earthing (600 X 600 X 3.15mm) with running copper 2RUN flat 25 X 5mm from copper plate to funnel of 40mm dia G.I pipe including all accessories & brick massonary pedastal with extra super structure including cement plastering etc as required as per direction of Engg.-in-Charge.
120Supplying and laying 25 mm x 5 mm CU earth strip ISI marked on surface or in recess for connection etc as required.
121Providing and fixing GI Flat 25 mm X 5 mm thick on parapet or surface of wall complete as required.
122Supply, delivery and laying of 40mm HDPE pipe and cable inside the HDPE pipe as per construction standard specification and draning etc
123Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
1244 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
125Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
126Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
127Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
128Supplying and fixing 25Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years.
129Supplying and fixing 40Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years.
130Supplying and fixing 63Amps rating,C series,10KA breaking capacity ,DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The MCB should be Replacement Warranty will be 3 years.
131S/F of 63A 30mA DP RCCB in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on RCCB will be 3 years (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)
132S/F of 40A 30mA DP RCCB in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on RCCB will be 3 years (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)
133Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years.
134Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years.
135Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
136Size 60mm(H) x 200mm(W)
137Size 60mm(H) x 300mm(W)
138Supply ,installation ,testing & commissioning of 20KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 1 ph output, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 24 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD.
13958.5-KVA Silent D.G. SET
140Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 58.5KVA ( Make -Kirloskar / Jakson ) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years
141ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21.
142ENGINE: Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 58.5 KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 10 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standards
143AMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 58.5KVA DG Set complete with Battery Charger & leads as required.
144BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required.
145FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. *It also includes 2 nos copper plate earthing for body and 4 nos copper plate earthing for neutral, control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work)
146SAFETY EQUIPMENTS
147Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj
148Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m)
149Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
150Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room.
151PANEL
152S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.40X10MM Separate Aluminium Earth bus bar should be installed. ON,OFF,TRIP INDICATION for all incommer, changeover and outgoing feeder to be provided.
153MAIN PANEL
154In commer-1-01 number of 250A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release . ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS(FROM TRANSFORMER)
155In commer-2-01 number of 125 4P Icu=100%Ics,36Ka withTMR based release with adjustable overload . ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS(FROM DG)
156Changeover-1- 01 no of 160A 4P onload changeover switch (62.5 KVA DG 01 NO)(Make-L&T/Siemens/Schneider/C&S)
157Busbar-1&2 04 numbers of 300Amps copper busbar with 1.6A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)
158Out going- 01 number of 125A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
159Out going- 05 numbers of 63A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
160Out going- 5 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)
161Out going- 10 numbers of 63A rating,10 KA breaking capacity,C series, 2P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)
162Out going- 2 numbers of 40A rating,10 KA breaking capacity,C series, 4P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)
163Out going- 4 numbers of 32A rating,10 KA breaking capacity,C series, 2P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)
164Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.
165(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data.
166(iii)1 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)
167S/I/T&Commissioning of LT indoor wall mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL UPS CONNECTED LOAD) BUILDING UPS)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40ka shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. ON,OFF,TRIP INDICATION for all incommer, changeover and outgoing feeder to be provided.Provision for potential free ON,OFF,TRIP contacts should be given for BMS/EMS.
168In commer 1- 1 numbers of 63A rating,10 KA breaking capacity,C series, 2P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)
169Changeover-1- 01 no of 63A 2P MCB changeover switch(Make-Siemens/Schneider/LEGRAND)
170Busbar- 02 numbers of 100Amps 25*3mm copper bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
171Out going- 10 nos 40A 2P MCB,240V,C SERIES 10kA, . Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
172Instrument- (i) 01 numbers phase indicating lamp with toggle switch & HRC fuse.
173MAIN AC PANELS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) PUMP)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40ka shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.
174In commer 1- 01 number of 63A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
175Busbar- 04 numbers of 100Amps 25*3mm copper bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
176Out going- 02 nos 32A 4P MCB 10kA,C . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9
177Out going- 03 nos 20A 2P MCB 10kA,C . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9
178Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
179(ii) 01 set of 0-100Amps MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)
180PUMP PANELS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) PUMP)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40ka shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.
181In commer 1- 01 number of 63A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
182Busbar- 04 numbers of 100Amps 25*3mm copper bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
183Out going- 02 nos 32A 4P MCB 10kA,C . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9
184Out going- 03 nos 20A 2P MCB 10kA,C . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9
185Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
186(ii) 01 set of 0-100Amps MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)
187External Lighting panelSupplying,installation,testing & commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 32A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 32 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB as outgoing Make-LEGRAND-dx3 / Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 3 years of acceptance of materials
188CCTVSupply, Installation, Testing & Commissioning of Full High Definition 5MP( 2880 x 1624) resolution vandal proof dome/bullet camera, 1/3\\" Progressive Scan CMOS Sensor, IR Cut mechanical Filter for True Day & Night vision, Support dual streams, Onvif supported, IP67, IK 10 Weather proof outdoor enclosure, Inbuilt Smart IR LEDs with intensity control, IR 50 mtr, H.264 / H.265, Supports android and iOS APP for Smart phone and tablets, with Inbuilt audio, -10°C to + 50°C, CE, FCC, RoHS . Make-Honeywell series 20/Pelco/Axis
189Supply , Installation, testing , commissioning of 32 Channel NVR with 4 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS). Make-Honeywell series 20/Pelco/Axis
190Supply & Installation of surveliance 8 TB HDD .Make:WD/Segate/Toshiba
191Supply of 43\\" 4K, LCD BACKLIT LED display. RESOLUTION 3840X 2160 HDMI, DVID, DP, RJ45, USB, WIFI, BRIGHTNESS 500 nits, Operation Hour 24/7, Aspect ratio 16:9, Haze 25%, 2200Hz, 20 WATT SPEAKER INBUILT,Make-Sony/Samsung/LG
192Supply and installation of 24 Port Layer2 Giga (10/100/1000BaseT) PoE Switch with 4 x 1Gig SFP Port , Switching Capacity 56 Gbps, Throughput 41.7 Mpps ,Management Port 1 x RJ 45 Console port ,PoE power budget 270 Watt, Switch should support IEEE 802.3af & IEEE 802.3at standard ,MAC Address 16K , Jumbo Frame 12K ,Temperature Working 0°C~50°C, storage -40°C~70°C, Power Supply AC: 100~240VAC.Digisol Model No. DG-GS1528HPE-P/Cisco/HP
193Supply and laying of 4 pair Cat6 U/UTP Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Tyco / Legrand / Panduit
194Supply of Cat6 UTP 24 Port Jack panel loaded with Spring loaded shuttered Jack and Rear Cable manager. Should include labels with transparent clear label covers at the front and Port number at the back. 4 x 6 ganged jack configuration. Compliance to TIA/EIA-568-C.2-1, IEC-603-7, ISO 11801 Class E. ETL Verified etc. complete as required.Make: Legrand/Systimax/Panduit
195Supply & Installation of Cat6 Factory crimpped moulded patch cord, 2mtr. Make: Legrand/Systimax/Panduit
196Supply & Installation of Cat6 Factory crimpped moulded patch cord,1mtr, Make: Legrand/Systimax/Panduit
197Supply of 9U WALL mountRack with all accessories like Ventilation Fan- I No. 4 nos. 5 amps socket & Switch in one PDU, cable manager etc. complete as required. Make : Netrack/Valrack/Rittal/APW
198Supplying and fixing of 1 or 2 Module (75 mm X 75 mm), GI box along with modular base & cover plate for modular switches in recess etc as required.Make-Legrand/Schneider/Siemens
199Supply and Installation of Cat6 I/O with Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Tyco / Legrand / Panduit I/O Single
200Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)
20120 MM
20225 MM
203ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEMSupply, Installation,Testing & Commisioning of 2 Loop Microprocessor based Addresable fire alarm control panel , fully networkable with each loop capable of taking 99 devices, 8 line x 40 character alpha- numeric liquid crystal display .The panel shall be soft addressable type . The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification. The fire alarm panel shall be suitable for software integration with BMS & PA system.Make-Morley IAS/Siemens/Bosch/Edward
204Supply, Installation, Testing & commissioning of Analog Addressable smoke cum heat detector with status indicator and inbuilt isolator module . Make-Morley IAS/Siemens/Bosch/Edward
205Supply, Installation, Testing & commissioning of Addressable Manual Call Point soft addressable type with in built fault isolator as required.Make-Morley IAS/Siemens/Bosch/Edward
206Supplying, installing, testing and commissioning of Hooter Cum Strobe at 85 dB (A) @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. The device shall be UL/EN/FM approved. Make-Morley IAS/Siemens/Bosch/Edward/Honeywell Please Enable Macros to View BoQ information
207Supplying, installing, testing and commissioning of Hooter Cum Strobe at 85 dB (A) @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. The device shall be UL/EN/FM approved. Make-Morley IAS/Siemens/Bosch/Edward/Honeywell Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56452572
AUTHORITY Government Departments
TENDER VALUE 7.19 Crore
LAST DATE 29-07-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Construction Of Court Building At Bijepur
Basic Detail
Tender No CCENC(RANDB) /25/ 2025-26
Bidding Type Tender
Location
City Bargarh
State Odisha
Key Dates
Publish Date 14 Jul 2026
Submission Date 29 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 7.19 Crore
Tender Fee 10000
EMD 7.19 Lakhs
Exemption Available
Document List
19COURT.pdf
BOQ_601397.xls
ea9da45d-b78d-4a05-ac64-6e7c29740a6d.html
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

19COURT.pdf

xls

BOQ_601397.xls

html

ea9da45d-b78d-4a05-ac64-6e7c29740a6d.html

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail