Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #56449407

Tender For Supply, Delivery And Replacement Of Electrical Items Of Vcb, Transformer, Lt & Ats Panel At Kamalnagar (12.09 Mld) Wtp Of Surface Based W/S Scheme, Purbasthali-Ii Block In The District Of Purba Bardhaman Under Central Mechanical Division,

Issued by Government Departments · Purba Bardhaman, West Bengal
Tender Value
4.13 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
0 days left
EMD
8550
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Purba Bardhaman → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Delivery And Replacement Of Electrical Items Of Vcb, Transformer, Lt & Ats Panel At Kamalnagar (12.09 Mld) Wtp Of Surface Based W/S Scheme, Purbasthali-Ii Block In The District Of Purba Bardhaman Under Central Mechanical Division, Phe Dte

BOQ

Name of Work:- Supply, delivery and replacement of electrical items of VCB, Transformer, LT & ATS Panel at Kamalnagar (12.09 MLD) WTP of Surface based W/S Scheme, Purbasthali-II Block in the district of Purba Bardhaman under Central Mechanical Division, PHE Dte
Sl. No. Item Description
111KV 3 Panel VCB
2Outgoing - 1
3Supply, delivery at site and storage of following items :
4O/C & E/F Relay (Schneider, Model : Micom-P111/Easergy P1)
5Auxiliary Relay of 110-126VDC (GE T&D, Model-VAA332G8338BCH)
6200Watt Space Heater of 230V AC (Make : Reco)
7Thermostat, Range-30Deg. C-110Deg.C, 15Amps, 230/250V AC (Make : ELCON GOLD, Model : MM-106)
81.1KV grade 2.5sq.mm single core copper control cable for space heater and thermostat wiring. (Approved Make)
9Replacement of defective O/C & E/F Relay by newly supplied Relay of Item Sl.No.1.01.01 above including Modification, Rectro-Fitting & Calibration complete as per direction of EIC.
10Replacement of defective Auxiliary Relay by newly supplied Relay of Item Sl.No.1.01.02 above including connections & calibration complete as per direction of EIC.
11Replacement of defective 200Watt Space Heater of VCB Chamber by newly supplied Space Heater of Item Sl.No.1.01.03 including connection complete as per direction of EIC.
12Replacement of defective Thermostat of VCB Chamber by newly supplied thermostat of Item Sl.No.1.01.04 including connection complete as per direction of EIC.
13Replacement of 2Nos. defective Space Heater, 1No. Thermostat along with its burnt out wiring by newly supplied Space Heater, Thermostat & Wiring Wire of Item Sl.Nos. 1.01.03 to 1.01.05 respectively as per direction of EIC.
1411/0.433KV 1000KVA Indoor OLTC Transformer (2 Nos.)
15Supply, delivery at site and storage of following items :
16All kinds of Gaskets including Top Cover, Inspection Cover, Valve etc. & Oil Seal for HT & LT Bushing of 1000KVA OLTC Transformer (11KV/433V)
17Replacement of existing gaskets & oil Seal of 1000KVA OLTC transformer by newly supplied gasket & Oil Seal of Item Sl.No. 2.01 above after disconnection of HT & LT Terminals and draining out the existing transformer oil by opening out the top cover and inspection cover, tap switch, conservator tank, rediators, buchholz, drain valve, OLTC Tap Cover, HT & LT Bushing Portion etc. to prevent oil leakage as per direction of EIC.
18Oif filtration of 2 Nos. 1000KVA OLTC Transformer by hired Filter Machine ( 1250 x 2 + 260 x 2 OLTC ) = 3020
19Di-electric strength test of transformer oil by hired Testing (BDV) Machine as per direction of EIC.
20Replacement of existing damaged Silica Gel by newly supplied Silica Gel for Tr.1 & Tr.2 as per direction of EIC.
21Supply, delivery at site and \storage of transparent Breather with 500gms. Silica Gel.
22Replacement of existing damaged Silica Gel Breather by newly supplied Breather with Silica Gel of Item Sl.No. 2.06 above as per direction of EIC.
23Supply, delivery at site and \storage of Tap Position Indicator for RTCC Panel - 2 (Make : Ascensor)
24Replacement of existing damaged Tap Position Indicator of RTCC Panel-2 by newly supplied Indicator of Item Sl.No.2.08 above including connection complete as per direction of EIC.
25Up & Down Transportation cost for carrying of Oil Filter Machine & BDV Testing Set. Etc.
26LT Panel : Chemical House (2F2 Feeder & 2F3 Feeder)
27Supply, delivery at site and storage of following items :
28Indicating Lamp (LED) - Red.
29150Amps 4 Pole Cable Terminal
30Neutral Link (Terminal)
311.1KV grade Single Core 6sq.mm copper flexible wire. (Approved Make)
32Copper Ring/Pin Socket suitablr for 6sq.mm Copper Wire (Approved Make)
33Al. ring Socket suitablr for 16sq.mm Al. Ar. Cable.
34Fault Rectification by replacement of existing damaged 1 No. Indicating Lamp, 2 Nos.Terminal, 1 No. Neutral Link of 2F2 & 2F3 Feeder by newly supplied Indicating lamp, Terminal and copper wire with its sockets of Item Sl.Nos. 3.01 to 3.06 above including termination complete as per diection of EIC.
35Motor Control Centre for Blower Room in ADM Building : 1F1 Feeder (Blower & Actuator) & 1F2 Feeder (LDB-1 Ground Floor)
36Supply, delivery at site and storage of following items :
37Indicating Lamp (LED) - Red.
38Coppper Ring Socket suitable for 10sq.mm Cable.
39150Amps 4 Pole Cable Terminal
401.1KV grade Single Core 10sq.mm copper flexible wire.
41Fault Rectification by replacement of existing damaged 1 No. Indicating Lamp, 1No.Terminal, of 1F1 & 1F2 Feeder by newly supplied Indicating lamp, Terminal and copper wire with its sockets of Item Sl.Nos. 4.01 to 4.04 above including termination complete as per diection of EIC.
42132KW ATS Panel (5F2, 10F2 & 3F2)
43Supply, delivery at site and storage of following items :
4412.5 KVAR 440Volt 16.4Amps. 50Hz. Capacitor of EPCOS make
45Replacement of existing defective 12.5KVAR Capacitors by newly supplied Capacitor of Item Sl.No.5 above including connections complete as per direction of EIC.
46Add GST @ 18%
47Add Cess @ 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56449407
AUTHORITY Government Departments
TENDER VALUE 4.13 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Supply, Delivery And Replacement Of Electrical Items Of Vcb, Transformer, Lt & Ats Panel At Kamalnagar (12.09 Mld) Wtp Of Surface Based W/S Scheme, Purbasthali-Ii Block In The District Of Purba Bardhaman Under Central Mechanical Division, Phe Dte
Basic Detail
Tender No WBPHED/EE/CMD/eNIT-01/2026-27
Bidding Type Tender
Location
City Purba Bardhaman
State West Bengal
Key Dates
Publish Date 14 Jul 2026
Submission Date 21 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value 4.13 Lakhs
Tender Fee Ref. Documents
EMD 8550
Exemption Not Available
Document List
0feb19ba-3be6-4794-bd76-ae8cb532ce80.html
2911-N-pdf.pdf
BOQ_2532520.xls
Tendernotice_1 (15).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

0feb19ba-3be6-4794-bd76-ae8cb532ce80.html

pdf

2911-N-pdf.pdf

xls

BOQ_2532520.xls

pdf

Tendernotice_1 (15).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders