Tender For Special Repair To Bldg No T-88 Of Asc Coy Khalsar And Special Repair To Bldg No T-29 Of 71 Omp At Khalsar Under Ge 873 Ews
Tender Overview
Project Description
Tender For Special Repair To Bldg No T-88 Of Asc Coy Khalsar And Special Repair To Bldg No T-29 Of 71 Omp At Khalsar Under Ge 873 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Jul-2026 | BOQ Corrigendum | BOQ | 03-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of plain of corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and as directed. |
| 2 | S&F Galvanised MS sheeting of 0.63mm thick corrugated ISI Marked and made of Shakti with two cougation side laps and fixed with J hooks two framed work with PVC and steel washers as in roof & wall with Zinc coating of 275 complete all as specified and as directed. |
| 3 | All as per item No 02 above but except sheets complete all as specified and directed. |
| 4 | S&F plain, galvanised MS sheeting of 0.63mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 5 | Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation board/slabs/ blanket any thickness including cover filllets complete all as specified and as directed. |
| 6 | M&L 9 mm thick prelaminated partical board, interior grade ,prelaminated one side with decorative choice lamination and other side balancing white lamination ,fixed with nails as in wall panelling complete all as specified and as directed. |
| 7 | M&L 9 mm thick prelaminated partical board, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination ,fixed with nails as in ceiling works complete all as specified and as directed. |
| 8 | Dismantling timber framed in fillets, rails, posts rafters, purlines, etc under 40 Sq cm in section complete all as specified and as directed. |
| 9 | M&L second class softwood plain filllets, rectangular in section, clean swan, secured with nails exc 13 and n.exc 25 Sqcm complete all as specified and as directed. |
| 10 | M&L second class softwood plain fillets, rectangular in section, clean swan, secured with nails exc 3 and n.exc 6 Sqcm complete all as specified and as directed. |
| 11 | Demolition of Cement Concrete(unreinforced) in ground floors and pavings n exc 15 cm thickness complete all specified and directed |
| 12 | M&L 25mm thick plain cement concrete 1:2:4 type B-0 using 12.50mm graded crushed stone aggregate) as in floor complete all as specified and as directed. |
| 13 | M&L for Non Skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl Screed bed or bedding layer of mortar 15mm thick in Cement Mortar 1:4 for laying floor finishes complete all as specified and as directed. |
| 14 | Taking down chowkats or frames with shutters (without taking off shutters from frames) of size not exceeding 1.5 SQMs each complete all as specified and as directed |
| 15 | Supply and fix steel window with side hung double shutters of gauzed shutter openable inside and glazed shutter openable outside with projecting type hinges , steel handles and steel peg stay with glazing bars dovetailed or welded and ventilator fixed type complete all as specified and as directed |
| 16 | M&L 4mm thick ordinary quality sheet glass and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed. |
| 17 | S&F Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture1.40mm and fixed withstainless steel wire staples complete all as specified and as directed |
| 18 | Taking down chowkats or frames with shutters (with out taking off shutters from the frames) exc 1.5sqm but n. exc 4 Sqm each.(Steel/Wooden) complete all as specified and as directed. |
| 19 | S & F plain, solid, straight 2nd class hard wood frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed. |
| 20 | S&F 40 mm thick 2nd class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particles board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and as directed. |
| 21 | M&L for painting to wooden surface of any description not other wise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on ply wood including preparation of surfaces etc complete all as specified and as directed. |
| 22 | Supply & fix MS sliding door bolts 250 mm long clip type, stove enamelled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on stapple plate and fixed, complete all as specified and directed. |
| 23 | S & F butt hinges 100mm mild steel cold rolled, medium weight complete all as specified and as directed. |
| 24 | Supply & fix MS barrel tower bolt 150mm long stove enamelled black, complete all as specified. |
| 25 | S & F of Extruded aluminium alloy handles fabricated type anodised 125 mm size complete all as specified and directed. |
| 26 | S & F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor and fixed, complete all as specified and directed. |
| 27 | S & F in repair Curtain rail Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc and fixed, complete all as specified and directed. |
| 28 | M&L for PCC 1:3:6 type C2 75mm thick using 40 mm graded stone aggregate as in plinth protection and Finishing cement concrete surface even and smooth with out using extra cement complete all as specified and as directed. |
| 29 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed |
| 30 | M & L Framed brecket of angals or tee with web and flanges cut to shape, drilled and countersunk for screw,including bending and wending angles as necessary gusset plates, riveting, etc n exc 10 kg each brackets conforming to Fe-290 Gde-E-165 Brackets over 10 kg each to be measured under Structural Steel) complete all as specified and directed. |
| 31 | M & L for Rolled sections as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates. complete all as specified and directed. |
| 32 | S & F Steel work in tubular trusses including special shaped washer etc. completed using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as specified and directed. |
| 33 | Preparation of new steel surfaces of any description over 10cm in width or girth, not otherwise described, and applying two coat of synthetic enamel paint over one priming coat of red oxide complete all as specified and as directed |
| 34 | M &L for Preparation of old painted steel surfaces of any description over 10cm in width or girth, not otherwise described, and applying two coat of synthetic enamel paint complete all as specified and as directed. |
| 35 | M&L of machine cut kota stone slab flooring 20-25 mm thick over screed bed or bedding layer of mortar in CM (1:4) 15 mm thick for laying floor finishes jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 36 | M&L for 20mm thick screed bed or bedding layer of mortar for laying floor finishes in CM 1:4 complete all as specified and directed. |
| 37 | M&L for chequered cement concrete tiles 20cmx20cmx25mm thick, set and jointed and pointed in neat cement slurry in floors with grey cement and no pigment complete as specified and directed. |
| 38 | M&L for 100 mm thick PCC 1:4:8 type D2 (40mm graded crushed stone aggregate) as in sub base complete all as specified and directed by Engr-in-charge |
| 39 | M&L for providing cement cencrete types C-1 1:3:6 (20 mm agg) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 40 | Taking down carefully damaged copper/aluminum point wiring (light/fan/socket or power) complete including fixture and fittings such as switches, ceiling roses, cassing & capping, pendants, sockets, light fitting etc and making good disturbed surfaces of wall/roof complete all as specified and directed. |
| 41 | Taking down of MCB DB/TPN/SPN 4Way/8way including MCB SP and spn and making good of wall complete all as specified and directed. |
| 42 | M&L Point wiring using approved colour coding as per IS for modular switch and socket in concealed conduit with 1.5 Sqmm FRLSH cable (multi-stranded) PVC insulated and sheathed electric cable 1100 volts drawn through PVC Conduit and including rigid 20 mm PVC concealed conduit pipe and conduit Accessories ISI marked with valid CML No ( IS 9537-1983 for conduit and IS 3419: 1976 for conduit accessories ) meduim grade including fixing / grouting with mild steel / Modular Metal flush boxs (with earth dolly ) with suitable size modular cover plate including runing up 1.5 sqmm multistanded copper conductor PVC insulated cable as earth continutiy conductor along with wiring and connecting to the common earth dolly for fixing the switches/sockets/regulators etc all as specified and directed at site for the follwings Note: - 1. switches and sockets shall be measured and paid separately. |
| 43 | One light/fan point controlled by one 5 Amps one way switch |
| 44 | One 3 pin socket outlet 5 Amps on independent board |
| 45 | One 3 pin socket outlet 5 Amps on same board |
| 46 | All as per Serial No 42 above but point wiring with using 2.5 sq.mm (nominal area) copper PVC FRLSH insulated unsheathed stranded copper conductor incl same size continuous earth wire on independent board for one 5/6 pin, 5/15 Amps switch socket outlet combination on independent board |
| 47 | M&L Point wiring using approved colour coding as per IS for modular switch and socket in concealed conduit with 2.5 Sqmm FRLSH cable (multi-stranded) PVC insulated and sheathed electric cable 1100 volts drawn through PVC Conduit and including rigid 20 mm PVC concealed conduit and conduit Accessories ISI marked with valid CML No ( IS 9537-1983 for conduit and IS 3419: 1976 for conduit accessories ) meduim grade including fixing / grouting with mild steel / Modular Metal flush boxs (with earth dolly) with suitable size modular cover plate including runing up 2.5 sqmm multistanded copper conductor PVC insulated cable as earth continutiy conductor along with wiring and connecting to the common earth dolly for fixing the switches/sockets/regulators etc all as specified and directed at site for the follwings Note: - 1.switches and sockets shall be measured and paid separately. |
| 48 | S & F Modular switch 1 way 6 A,1 module, 240 Volts complete all as specfied and directed by Engr-in-Charge. |
| 49 | S&F Modular Socket outlet 6 Amp- 2/3 Pin combined 3 module flush type complete all as specified and as directed. |
| 50 | S&F Modular Switch socket Combination 16 Amp,6 Pin,3 Module flush type complete all as specified and as directed. |
| 51 | S & F Modular Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 52 | Supply and fixing Rechargeable LED Bulb 9 Watt ,220 V, white color complete all as specified and as directed. |
| 53 | S&F surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver tube light fitting 20 Watt, 4 ft long, 220 Volts , and connecting to ceiling rose with three core twisted flexible copper cable of suitable size complete all as specified and directed. . |
| 54 | S&F Ceiling rose surface backelite ISI marked with 3 terminal including connecting and testing complete all as specified and directed. |
| 55 | S&F MCB DB sheet enclosure,Double door with internal gasket protection from water ingration type, Triple pole and neutral 415V with 200 Amp rated bus bar suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. Make : - L&T/Legrand/ Schneider |
| 56 | Supply and fixing 415V, 10 KA 'B' curve Miniature circuit breaker (MCB) of Triple poles Neutral and currentcarrying capacity 63 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed. |
| 57 | Supply and fixing 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of Single pole neutral SPN and currentcarrying capacity 40 Amp, in the MCB DB Complete with connection testing and commissioning all as specified and directed. |
| 58 | S&F MCB DB sheet enclosure,Double door with internal gasket protection from water ingration type, single pole and neutral 240V with 200 Amp rated bus bar suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed.Make : - L&T/Legrand/ Schneider |
| 59 | Supply and fixing 240V, 10 KA 'C' curve Miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed. |
| 60 | Supply and fixing MCB SPN (20-32) Amp 240V, 10KA 'C' curve current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed. |
| 61 | Supply and fix in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve termostate, NRV, connection piece etc complete all as specified and directed. |
| 62 | M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on complete all as specified and as directed. |
| 63 | Supply and fixing LED Building Secuirity light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and including suitable size street light brackets accessiores making all necessary connection with suitable capacity of 3 core circular cable complete all as specified and directed. |
| 64 | Supply and fix in repair Exhaust fan, steel body AC Phase. 230V, 50 Hz,RPM1200 of size 450 mm sweep with, blades, and frame and louvers complete all as specified and as directed. |
| 65 | M & L for sub main Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS is PVC insulated copper conductor, single core cable in surface/ pvc casing capping as required 2x 4.0 sq. mm +1x 4.0 sq. mm earth wire with complete connection complete all as specified and as directed. |
| 66 | S & F LED light fitting 1x9 Watt /1X10 Watt bulk head luminaires including LED light driver holder connecting up with Single core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 67 | Supply and fixing for XLPE insulated, Armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 4 core, cross-sectional area 10 sq. mm complete all as specified and as directed. |
| 68 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and as directed. |
| 69 | Returing, filling in incl spreading, levelling watering and well ramming in layers n.exc 25cm width, complete all as specified and as directed. |
| 70 | Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point complete all as specified and as directed. |
| 71 | Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and as directed. |
| 72 | M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x45 mm complete all as specified and as directed. |
| 73 | Deduct Schedule of Credit of as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender