Public Administrative Department Local Bodies Closing in 2 days TDR #56446777

Tender For Provision Of 03 Nos. Semi High Mast Light Pole Located Opposite To Police Apartment Near Pulia, Main Gate Entry Shastri Mohalla And Near Community Centre, Patparganj Village In Ward No. 197, Ac-57 (Patparganj) Under Shahdara (South) Zone.

Issued by Local Bodies · Delhi, Delhi
Tender Value
6.47 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
2 days left
EMD
14000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of 03 Nos. Semi High Mast Light Pole Located Opposite To Police Apartment Near Pulia, Main Gate Entry Shastri Mohalla And Near Community Centre, Patparganj Village In Ward No. 197, Ac-57 (Patparganj) Under Shahdara (South) Zone.

BOQ

Name of Work:- Provision of 03 Nos. Semi High Mast Light Pole located opposite to Police Apartment near pulia, Main gate entry Shastri Mohalla and Near Community Centre, Patparganj Village in Ward No. 197, AC-57 (Patparganj) under Shahdara (South) Zone.
Sl. No. Item Description
1Earthing with GI earth pipe 4.5 Metre long, 40mm dia i/c accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/coke and salt) as required.
2Providing and Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
3Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
5Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
6Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 Hz, Operating temp range -15 deg to 50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66, IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR -15 , lenses for beam angle 30deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (Asper ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 150 W
7Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc..direct in ground (75 cm below ground level)including excavation and refilling the trench but excluding sandcushioning and protective covering etc., complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
8Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc. in theexisting trench , complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
9Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd.
10Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumfrential weld. It should also included accessories For High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries symmitrically And its control gears boxes and lighting finial ,the mast shall have integral type manual raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC(1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in possion, reinforcement of cold twisted bars of 12 mm dia-2100mm long(approx)-16 nos. and reinforcement of cold twisted bars of 8 mm dia-3700 mm (approx)-13 nos. (with 150mm specing ) as required with positioning of foundation bolts and providingDWC HDPE pipe for cable entry and exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4 Nos S.P MCB, 63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
11Providing and fixing name board made of MS sheet 90*60 cm,1mm thick with frame of MS angle 50*50*6mm, two diagonal braces at bthe back of the sheet of MS flat 40*6mm ,total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4(1 cement:coarse sand:4 graded stoneaggegate 20mm nominal size) 30*30*45 cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer,painting with syntheic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in -charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56446777
AUTHORITY Local Bodies
TENDER VALUE 6.47 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Provision Of 03 Nos. Semi High Mast Light Pole Located Opposite To Police Apartment Near Pulia, Main Gate Entry Shastri Mohalla And Near Community Centre, Patparganj Village In Ward No. 197, Ac-57 (Patparganj) Under Shahdara (South) Zone.
Basic Detail
Tender No EEE-I/2026-27/2.2
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 13 Jul 2026
Submission Date 20 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 6.47 Lakhs
Tender Fee 590
EMD 14000
Exemption Not Available
Document List
4b41cc11-a06d-41a0-8369-3bb3b2ee2e8c.html
BOQ_331253.xls
condition.pdf
Tendernotice_1 (6).pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

4b41cc11-a06d-41a0-8369-3bb3b2ee2e8c.html

xls

BOQ_331253.xls

pdf

condition.pdf

pdf

Tendernotice_1 (6).pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders