Tender For Repair/ Maintenance And Improvement Of Lt Network, Ug Cables, Oh Lines, Lt Panels, And Other Connected Items At Various Locations Of Anarwala Under Age E/M-Ii Of Ge Dehradun.
Tender Overview
Project Description
Tender for Repair/ Maintenance And Improvement Of Lt Network, Ug Cables, Oh Lines, Lt Panels, And Other Connected Items At Various Locations Of Anarwala Under Age E/M-Ii Of Ge Dehradun.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Jul-2026 | critical dates | Date | 04-Aug-2026 |
| 2 | 25-Jul-2026 | Revised BOQ | BOQ | 04-Aug-2026 |
| 3 | 04-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 11-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Excavation in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed. |
| 3 | Material and labour for sand cushioning & covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed. NOTE: - Punned thickness shall be measurement & paid. |
| 4 | Material and labour for sub class B bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as specified and directed. |
| 5 | Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed. |
| 6 | Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 7 | Material and labour for cutting existing road/ hardstanding of any type by using crow bar chisel upto a depth of 60 cm for laying HDPE/ GI pipe upto 100 mm including making good the surface by returning, filling, watering, ramming in layers of 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 8 | Material and labour for cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundations and mass concrete for foundations of poles etc complete all as specified and directed. |
| 9 | Material and labour for cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary from work for finishing exposed faces of concrete smooth and even using extra cement complete all as specified and directed. |
| 10 | Taking out carefully LT cable of any size from 10 sqmm to 300 sqmm or of any type or make from ground/ poles/ pipes etc and testing for serviceability and laying the same serviceable LT cables under ground/ on poles/ through pipes etc at same or any other location and testing after connections complete all as specified and directed.Note:- (a) Item to be measured only when cable is found serviceble for reuse.(b) Necessary excavation, sand cushioning, cable protection covers, returning, removal etc shall be measured and paid separately under relevant items. |
| 11 | Material and labour for laying, jointing and testing in replacement underground XLPE insulated & PVC sheathed, armoured heavy duty multistranded electric cable with aluminium conductor, 1100 volts grade in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc and connecting with new aluminium lugs including taking out existing unserviceable of any size/ type complete for the following cables of cross sectional area all as directed: Notes:(a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately.(b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.(c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. |
| 12 | 10.0 Sqmm, 4 core. |
| 13 | 16.0 Sqmm, 4 core. |
| 14 | 25.0 Sqmm, 4 core. |
| 15 | 50.0 Sqmm, 3.5 core. |
| 16 | 70.0 Sqmm, 3.5 core. |
| 17 | 95.0 Sqmm, 3.5 core. |
| 18 | 120.0 Sqmm, 3.5 core. |
| 19 | 240.0 Sqmm, 3.5 core. |
| 20 | Supply and laying in trenches/ fixed to poles/ wall/ laid in floor GI steel tubing 80mm bore (dia) light grade including fitting bolt, nut & washers etc or wooden rubber bushing at the ends of complete all as directed incl disconnection and taking down existing tubing complete all as specified and directed. |
| 21 | Description all as per item No 11 but size of pipe 50mm dia. |
| 22 | Supplying, errecting and fixing in replacement steel tubular swaged poles, type 410-SP-31, 9.00 metre long height, complete with cast iron base plate, heat resistance finial taper plug, bolts, nuts and screws as specified including painting with two coats of synthetic enamalled paint over one coat of red oxide primer and 06 Nos bands/straps with white/ red/ black/ yellow as required (30cm wide each) epoxy heat resistant paint at a distance 30cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including taking out existing unserviceable pole of any type/ height/ make etc complete all as specified and directed.Notes: 1. Excavation, returning, removal, PCC for foundation and coping etc shall be measured and paid separately.2. Any damage done during erection of pole to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.3. Cost of T&P required for transporting/ handling/ erection etc of pole is deemed to be included in the rate quoted by the contractor. |
| 23 | Material and labour for fixing in replacement cross arms, bracing, supports, clamps and back plates fabricated from structural steel section (flat iron/ angle iron/ MS sheet) including back plate, MS boxes made out of MS sheet, clamps or D clamps made out of MS flat iron made to shape including nuts, bolts, washers, welding, bending hot or cold, drilling holes for bolt in any size or shape as directed inclusive of two coats of aluminium paint over a coat of red oxide primer including taking out existing unserviceable of any size/ type etc complete all as specified and directed. |
| 24 | Material and labour for fixing in replacement Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts for LT of size 20 x 15 cm. including taking down existing unserviceable of any type/ size etc complete all as specified and directed. |
| 25 | Dismantling existing steel poles/stuts ,any size carefully for reuse inclding necessary excavation, demolition of concrete etc and removing the old unserviceable poles/rubbish off the premises etc complete all as specified and directed. |
| 26 | Fixing only of street light poles of any length and dia retrieved against respective dismantling from ser item no 17 above including loading, shifting, unloading errection in true vertical position complete all as specified and directed. Note : Excavation and PCC for fixing of pole shall be measured and paid separately. |
| 27 | Material and labour for trimming/ pruning of tree branches up to 5 meters above & below and both sides to obtain clearance all around the LT over head lines / HT over head lines conductor upto 5 mtr from conductor including removing of cut branches and cleaning of site complete all as specified and directed. |
| 28 | Material and labour for painting of steel pole 09 meter height after preparing the surface by scrapping old paint with sand paper with two coat of aluminium paint over a coat of red oxide primer incuding making 5 nos of alternative strips of black and yellow paint of 30 cm width & numbering of pole as per existing complete all as specified and directed. |
| 29 | Supply and fixing in replacement digital 3 line display multifunction meter having features to measure Voltage, Amperes, power factor, active load etc complete all as specified and directed. |
| 30 | Supply and fixing in replacement LED indication Lamps (RYB) complete all as specified and directed. |
| 31 | Material and labour for replacement of unserviceable earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth strip 25x4 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point/ transformer/ panel all as directed and testing on completion as directed including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1:3:6) type C1, RCC pit cover, charcoal, salt including provision of earth lead protected by 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as specified and directed.Note: (i) If the desired earth resistance is not found within permissible limit of less than 5 Ohm, earthing shall be redone by contractor without any extra cost.(ii) Cost of galvanised earth lead upto 7.5 mtr, 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering is included in the rate quoted for this item. |
| 32 | Description all as per item 22 above but with galvanised iron strip 32x6 mm as earthing lead and protection pipe of dia 50mm. |
| 33 | Material and labour for replacement of unserviceable earthing with copper earth plate electrode 600x600x3mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to copper earth strip 20x3 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 1991 connected to earthing test point/ transformer/ panel all as directed and testing on completion as directed including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1:3:6) type C1, RCC pit cover, charcoal, salt including provision of earth lead protected by 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as specified and directed. Note: (a) If the desired earth resistance is not found within permissible limit of less than 2 Ohm, earthing shall be redone by contractor without any extra cost.(b) Cost of copper earth lead upto 7.5 mtr, 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering is included in the rate quoted for this item. |
| 34 | Supply and fixing of MCCB 415 V with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete of following capacities including fixing properly with new suitable size of thimbles, nut - bolt and washers and taking down existing unserviceable of any type/ make etc complete all as specified and directed. |
| 35 | MCCB 400 Amps, 4 pole of breaking capacity 36 KA |
| 36 | MCCB 250 Amps, 4 pole of breaking capacity 36 KA |
| 37 | MCCB 200 Amps, 4 pole of breaking capacity 25 KA |
| 38 | MCCB 160 Amps, 4 pole of breaking capacity 25 KA |
| 39 | MCCB 125 Amps, 4 pole of breaking capacity 25 KA |
| 40 | MCCB 100 Amps, 4 pole of breaking capacity 25 KA |
| 41 | MCCB 63 Amps, 4 pole of breaking capacity 25 KA |
| 42 | Supply, Installation, Commission and testing of busbar LT panel outdoor type LT (415 volts, 50hz, 3 phase 4 wire supply) of size 90cmx60cmx50 cm factory assembeled, weather & vermin proof (protection class IP43) fabricated out of 3.15mm thick CRCA sheet with front hinges opening, rubber lining, locking arrangement, powder coated extermally and internally including cable glands of suitabe size including taking down old unserviceable panel complete all as specified and directed and comprising the following as under :-(i) Aluminium busbar consisting of four No of capacity 300 amps duly insulated with heat shrinkable sleeve 1.1 KV grade mounted on heavy duty epoxy insulator.(ii) Provn for fixing of MCCB, 4P, 63 to 200 Amp.(iii) The panel shoud be fixed on and including angle iron stand made out of 50x6mm thick 60 cm height duly grouted 30 cm below ground level in PCC all as directed.(iv) RYB Indicating Lamp LED type 240 Volts - 01 set(v) Item rate includs excavation, PCC & earth work reqd for taking out old existing cable incl lugs thimble & relaying the same. |
| 43 | Supply and fixing of post top lantern LED type of 20 Watt capacity 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp from pole of any height/ pillar/ bldg wall etc CCT not less than 5700K, IP 65 complete including taking down existing unserviceable light fittings all as directed. |
| 44 | Supply and fixing of Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65/66 protection road way luminaries with high power LED 90 watt with Efficacy 110 Lm/W,CCT :5700 K with potted 5KV internal and 10 KV external inbuilt surge protection complete including taking down existing unserviceable light fittings all as directed. |
| 45 | Supply and fixing of Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65/66 protection road way luminaries with high power LED 70 watt with Efficacy 110 Lm/W,CCT :5700 K with potted 5KV internal and 10 KV external inbuilt surge protection complete including taking down existing unserviceable light fittings all as directed. |
| 46 | Supply, Installation, commissioning & testing of factory made CPRI approved, LT switch gear panel board, IP-54 (outdoor type), 415 volts, 50 Hz, AC supply, three phase and neutral (4 wire), 400 Amps aluminium busbars 4 pole, duly insulated with heat shrinkable sleeve as per colour code supported on epoxy insulatators, having independent compartment for insulated busbar, incoming feeder & each outgoing feeder i.e. cubicle type, made out of 3.00 mm thick CRCA sheet and 2mm thick inner enclosure CRCA sheet, rigid mild steel angle iron frame of 50x50x6mm with 900mm long extended legs grouting in PCC 1:3:6 type C2 block of size 1000x300x600mm, duly epoxy powder coated internally & externally with approved shade, rubber gasket, hinged front & back openable doors with proper locking arrangements for dust and vermin proof, complete including suitable size cable alley, lugs, cable glands, common earth bar of GI strip 32x6mm at bottom and making connections with MCCB spreaders/wiring with suitable size of single core PVC copper conductor cable, locking arrangements 65mm size and lock with keys, earth work and excavation comprising the following:Incoming :- (a) MCCB 250 Amps 4P, 35 KA, Adjustable thermal & fixed magnetic setting, Ics=100% of Icu with spreader link - 01 Nos., Meter set : Digital voltmeter,Ammeter + CT : 400/5, RYB indicating Lamp LED type 240 V, MCB SP 6A, 400 Amp Alluminium Bus Bar Outgoing :-(a) MCCB 100 Amp FP, 25 KA, Adj thermal & fixed magnetic setting,Ics=100% of Icu with spreader link - 02 Nos.(b) MCCB 63 Amp FP,16 KA, Adj thermal & fixed magnetic setting, Ics=100% of Icu with spreader link - 02 Nos. |
| 47 | Description all as per item No 30 here-in before but with following switch gears :Incoming :- (a) 250 Amps 4P, 35 KA , Adjustable tharmal & fixed magnetic setting, Ics=100% of Icu with spreader link - 01 Nos.(b) Meter set : Digital voltmeter, Ammeter + CT : 400/5, RYB Indicating Lamp LED type 240 V, MCB SP 6A, 400 Amp Alluminium Bus Bar Outgoing :-(a) MCCB 100 Amp FP,25 KA,,Adj thermal & fixed magnetic setting,Ics=100% of Icu with spreader link - 03 Nos.(b) MCCB 63 Amp FP,16 KA,,Adj thermal & fixed magnetic setting,Ics=100% of Icu with spreader link - 03 Nos. |
| 48 | Description all as per item No 30 here-in before but with following switch gears :Incoming :- (a) 400 Amps 4P, 35 KA , Adjustable tharmal & fixed magnetic setting, Ics=100% of Icu with spreader link - 01 Nos.(b) Meter set : Digital voltmeter, Ammeter + CT : 400/5, RYB Indicating Lamp LED type 240 V, MCB SP 6A, 600 Amp Alluminium Bus Bar Outgoing :-(a) MCCB 250 Amp FP,25 KA,,Adj thermal & fixed magnetic setting,Ics=100% of Icu with spreader link - 01 Nos.(b) MCCB 200 Amp FP,25 KA,,Adj thermal & fixed magnetic setting,Ics=100% of Icu with spreader link - 01 Nos. (c) MCCB 100 Amp FP,16 KA,Adj thermal & fixed magnetic setting, Ics=100% of Icu with spreader link - 02 Nos. |
| 49 | Supply and fixing of all in one LED solar street light fitting IP66 of capacity 30 watt made up of aluminium housing with mono crystalline solar panels for higher efficiency including in built high quality lithium ferrophosphate (LiFePO4) battery of capacity minimum 240W Hour/ 24 Ah @12.8 V of temperature range -10 to +50 C, solar panel capacity 50 Wp, charge controller with dusk dawn sensor having 5250 lumens in 30 Watts with system efficacy not less than 175 Lumens per Watt, complete taking down existing unserviceable light fittings all as directed.Dimmer profile:(a) From dusk - first 4 hours-100% & dimming-25% in non occupancy(b) 2nd 7 hours - 25% (fixed dimming)(c) 3rd 1 hour - 40% & dimming-25% in non occupancy (till dawn conditions) |
| 50 | Note : Tenderers may note that amount of credit Rs 160955.00 will be deducted from the total amount arrived, at the time of Acceptance of contract. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender