Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56446462

Tender For Special Repair Of Water Storage Tank With Monkey Caging Of Otm And Md Accn At Raiwala Mil Stn.

Issued by Statutory Bodies & Commissions/Committees · Dehradun, Uttarakhand
Tender Value
34.81 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
15 days left
EMD
69638
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair Of Water Storage Tank With Monkey Caging Of Otm And Md Accn At Raiwala Mil Stn.

BOQ

Name of Work:- SPECIAL REPAIR OF WATER STORAGE TANK WITH MONKEY CAGING OF OTM AND MD ACCN AT RAIWALA MIL STN.
Sl. No. Item Description
1Disconnecting and dismantling of water storage tank and removing from the site of following capacity of tank complete all as specified and as directed:-
2Capacity exc 500 Ltr but not exc 1000 Ltr
3S&F rotational moulded polyethylene water storage tank, double layer construction, white in colour ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms). of following capacity of tank complete all as specified and as directed:-
4Capacity 1000 Ltrs
5Taking up or down steel water tubing (GI Pipe) and connections of following bore complete all as specified and as directed :-
620mm bore
725mm bore
8S&F galvanised steel water tubing (GI pipe), medium grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :-
920mm bore
1025mm bore
11Refixing old galvanised steel water tubing, with all new fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :-
1220 mm bore
13S&F gun metal globe or gate valves, (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed, for following bore complete all as specified and directed:-
1420 mm Bore
15Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
16M&L for brick work with old size full brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
17M&L for 15mm thick plastering on fair faces of brick work or concrete wall surfaces in cement plaster (1:6) fininshed surface even and smooth without using extra cement complete all as specified and directed.
18M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed. Note :- The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per satifaction of Engr-in-Charge. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted.
19Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
20S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete.
21S&F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight per sqm not exc 4kg complete all as specified and as directed.
22M&L for two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed.
23M&L for shifting aside of MS monkey cage of 2.0m x1.8m x 2.0 m or any size & weight for repair / replacement of water tank, GI pipe, tank staging & refixing the same as required at site complete all as specified and directed.
24M&L PCC (1:2:4) type B1 using 20 mm graded aggregate as in bed block/hold fast blocks,benching, kerb and coping including necessary formwork complete all as specified and directed.
25Demolition of existing roof treatment i.e APP membrane incl cement screed, brick tiling incl mud mortar or lime concrete and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with Removal of existing roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed.Note :- (a) The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof. (b) The rates quoted shall deemed to be included for these items.
26M&L PCC 1:2:4 40 mm thick type B-0 (using 12.5 mm graded stone agg) mixed with liquid water proofing compound (mixed as per manufacturer direction ) and finishing the surface even and smooth without using extra cement as in roof paddingto receive roof treatment complete all as specified and directed. Note :- 1. Liquid water proofing compound will be measured and paid seperately.2. The work is required to be carried out at non-accessible roof . The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these item.
27M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregates, as in concrete angle-fillets with a radiaus of 75 mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks etc. and other similar situation to ease up about corners mixed with integral water proofing compound as per manufactur direction )Note :- Liquid water proofing compound (WPC) will be measured and paid seperately.
28Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed.
29M&L for one coat of cement slurry admixed with acrylic bonding compound SBR Latex liquid polymer (slurry will be prepared as per manufacturer direction) as to be used for bonding of new concrete/ mortar to old surface. Note :- (i)The work is required to be carried out at non-accessible roof. (ii)The contractor shall make arrangement of scaffolding,safety & security of workers and arrangement for approach to roof .(iii) The rates quoted shall deemed to be included for these item.
30M&L for water proofing treatment to non-accessible roof slab with APP based modified polymeric membrane as per manufacturer’s instructions with following course of description below :-(a) Applying a priming coat of bituminious primer @ 0.30 kg/sqm till the surface is properly impregnated.(b) Providing APP based 5 layer polymeric membrane minimum weighing 3.6Kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer's instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer(c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membranceNote :- 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only.2. The work is required to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof. The rates quoted shall deemed to be included for these items. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56446462
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 34.81 Lakhs
LAST DATE 07-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Water Storage Tank With Monkey Caging Of Otm And Md Accn At Raiwala Mil Stn.
Basic Detail
Tender No 86483/RWL/E8
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 13 Jul 2026
Submission Date 07 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 34.81 Lakhs
Tender Fee 500
EMD 69638
Exemption Available
Document List
9d01ebc7-f403-4603-9d7a-0f6b052bf242.html
BOQ_871666.xls
Tender86483.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

9d01ebc7-f403-4603-9d7a-0f6b052bf242.html

xls

BOQ_871666.xls

pdf

Tender86483.pdf

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender