Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56446454

Tender For Addition/Alteration To Store Room, Security Room, Sentry Post, P-40, P-19 And Rcma Building, Provision Of Temporary Shelter, Input Power Supply To Test Cell And Vertical Blinds At Gtre, Cabs And Cemilac Under Ge (I) R&D (East), Bangalore.

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
49.30 Lakhs
Estimated cost
Bid Submission
25 Jul 2026
10 days left
EMD
98600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addition/Alteration To Store Room, Security Room, Sentry Post, P-40, P-19 And Rcma Building, Provision Of Temporary Shelter, Input Power Supply To Test Cell And Vertical Blinds At Gtre, Cabs And Cemilac Under Ge (I) R&D (East), Bangalore.

BOQ

Name of Work:- ADDITION/ALTERATION TO STORE ROOM, SECURITY ROOM, SENTRY POST, P-40, P-19 AND RCMA BUILDING, PROVISION OF TEMPORARY SHELTER, INPUT POWER SUPPLY TO TEST CELL AND VERTICAL BLINDS AT GTRE, CABS AND CEMILAC UNDER GE (I) R&D (EAST), BANGALORE.
Sl. No. Item Description
1Demolishing RCC work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead all as per direction of Engineer- in-Charge.
2Demolishing cement concrete any description manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in -Charge.
3Demolishing brick work in cement mortar manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead all as per direction of Engineer- in-Charge.
4Material and labour for machine cutting of RCC beams (2 Nos) of approximate size 0.6m x 0.4m, length 12m and slab (1 No) of approximately size 12m x 4m, depth 150mm from the existing functional RCC structure without causing any structural deformation to existing functional structure at height upto 6m from ground level including cost of necessary scaffolding , machineries and labour all as per direction of Engineer- in-Charge.NOTE:- In case of any damage caused to existing functional structure, the same shall be repaired and made good and the rate quoted shall deemed to be inclusive of the same and no separate payment will be effective.
5Providing and fixing up to floor five level precast cement concrete solid block (1:1½:3) (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete all as per direction of Engineer- in-Charge.
6Material and labour for cement concrete flooring 1:2:4, 40 mm thick with 20 mm nominal size stone aggregate (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps, etc., complete all as specified and as directed.
7Material and labour for 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 fine sand) including mixing of water proofing compound, complete all as specified and as directed NOTE:- WPC shall be measured and paid separately.
8Supply only water proofing material in cement plaster work in proportion recommended by the manufacturer, complete all as specified and as directed.
9Material and labour for distempering with 1st quality acrylic distemper for walls (ready mix) having VOC content less than 50 grams per litre of approved brand, shade and manufacture to give an even shade for new work (two or more coats) including applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content with water thinnable cement primer on wall surface having VOC content less than 50 grams per litre.
10Material and labour for finishing walls with acrylic smooth exterior paint of required shade on new work (two or more coats applied @ 1.67 litre per 10 square metre over and including priming coat of exterior primer applied @0.9 kilo gram per 10 square metre) complete all as specified and as directed .
11Material and labour for micro-concreting in RCC slabs/ chajjas / beams / columns including chemicals, reinforcement, form work averaging thickness not exceeding 25mm thick comprising of the following stages:-(i) Support the slab and beam which is contributing the load for the column under rehabilation. (ii) Remove the damaged concrete portions completely till the reinforcement is exposed from the member carefully with mechanical arrangements and hand chiseling and clean the dust particles. (iii) Anchoring shear connectors in the form of 'L' shaped bars of 10 mm dia HSD in to the existing concrete by drilling holes not less than 75 mm depth, 12 mm dia in staggered position along the perimeter and height of member. Spacing shoud not be less than 300 mm for all sides, before anhoring clean the holes with jet compressed air to remove dust particles and anchor the dowel bars serve as shear connectors with chemical resin Lokfix E77 / Anchorfix 3030 manufactured by Dr. Fixit / Fosroc / Sika chemicals or equivalent.
12(iv) Clean the rusted reinforcement by applying a rust remover of Dr. Fixit / Fosroc / Sika or equivalent, allow the product to act for a few minutes, then remove the loosened rust by tapping, using a wire brush or any other suitable method. Ensure thorough cleaning from all sides, to achieve a completely rust-free and finished steel surface, followed by applying 2 coats of Epoxy Zinc Rich Primer of Dr. Fixit / Fosroc / Sika or equivalent anticorrosive coating to the exposed reinforcing bars after application of rust remover. Also apply on the shear connectors / welded mesh / additional reinforcement of repair surface, etc., complete as per direction of Engineer-in-Charge.(v) Applying a coat of two-part solvent free epoxy resin-based bonding agent epoxy bonding agent of Dr. Fixit / Fosroc / Sika or equivalent at rate of 2-3 square meter per kilogram, so that the old surface and new plastering surface can be bonded effectively. When the epoxy bonding agent reaches the tacky condition lay micro concrete.
13(vi) Providing leakproof shuttering system for the jacket portion of the members and dual shrinkage micro concrete of Fosroc / Sika/ Dr.Fixit or equivalent (compressive strength of micro concrete should be 55 MPa at 28 days)
14Material and labour for fixing nozzle for epoxy, packer drilling, installation and finishing. Drilling and fixing injection packers in reinforced concrete members including, drilling holes in structural members at the intervals as per recommendation of Engineer-in-Charge.(i) Cleaning of holes: Clean the holes by vaccum cleaner prior to fixing nozzles.(ii) Fixing of Packers: Insert 12 mm dia., 50~75 mm long injection packers in cleaned holes with structural grade epoxy adhesive like Dr. Fixit epoxy injection grout /Sikadur-31 or equivalent.(iii) Cutting of packers: Cut the packers by cut of wheel after completion of grouting and filling with repair polymer mortar without damaging structural elements, complete all as specified and as directed .
15Supply and apply a shrinkage free low viscous epoxy resin based injection grout, of Dr.Fixit epoxy injection grout / Sikadur®-55 LP IN or equivalent product, Yield : 0.88 litre per kilo gram, Compressive strength > 70 N/mm2 (7 days) according to BS 6319:PART 2; Flexural strength > 30 N/mm2 (7 days) according to BS 6319:PART 3; Tensile strength > 15 N/mm2 (7 days) according to BS 6319:PART 7; Bond strength > 10 N/mm2 (14 days) or concrete failure according to ASTM D 4541 complete all as specified and as directed.
16Raking out joints of stone masonry surface to the required width and depth, with due care and precaution, by mechanical / manual means, including preparing and cleaning the surface for re-pointing / refilling of joints, including disposal of rubbish to the dumping ground within 50 metre lead complete all as specified and as directed.
17Material and labour for flush / ruled pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) complete all as specified and as directed .
18Material and labour for cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete all as specified and as directed .
19Material and labour for random rubble masonry with hard stone in super structure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like in cement mortar 1:6 (1 cement : 6 coarse sand).
20Dismantling tile work in floors and roofs for thickness of tiles 10 mm to 25 mm laid in cement mortar including stacking material within 50 metres lead, complete all as specified and as directed .
21Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, sub base etc., up to floor five level, excluding the cost of centering, shuttering and finishing in cement concrete 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).
22Providing and laying in position cement concrete of specified grade for sunken floor, sub base or similar place, excluding the cost of centering and shuttering, all work up to plinth level in cement concrete 1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
23Material and labour for providing and laying water proofing treatment to sunken portion of WCs, bathroom and kitchen, etc., by applying cement slurry mixed with two component elastomeric acrylic based polymer modified cementitious composite compound coating of make as approved in TI 5/2003. The following procedures to be adopted during the execution of work :(i) Cleaning the sunken / lowered portion of RCC slab surface for full depth of sunken floor by wire brush , chisel out any mortar sticking the surface, all pipes passing through walls of sunken floor shall be laid before water proofing treatment is carried out .One 40 mm dia PVC pipe of medium grade , 35 cm long medium grade GI pipe with wire gauge on inside mouth shall be provided to each sunken portion.
24(ii) Applying FOSROC Nitoproof 600PF (Minimum 0.8 mm DFT) over a priming coat of Nitoproof water bound primer or equivalent product of Asian paints , M/s MC Bauchemic / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP applied as per manufacturer's instructions to bottom and full vertical sides of sunken floors . (iii) Fill it with water and check for dampness and seepage, in case the slightest indication of seeepage / leakage is noticed, the same shall be rectified by injection grouting to seal all cracks or application of polymer modified mortar FOSROC Nitobond SBR or equivalent or M/s MC Bauchemie / CIPY / SIKA / Pidilite Dr Fixit / Asian paints / Thermax / STP admixed with integral waterproofing compound or cementitious crystalline waterproofing compound in the affected area to seal all cracks and micro cracks if any and this shall be done by contractor at his own cost.
25(iv) Apply additional coat of FOSROC Nito proof 600 PF or equivalent or Asian paints / M/s MC Bauchemie / CIPY / SIKA / Pidilite Dr.Fixit / Asian paints / Thermax / STP. (v) All junction points of side walls where CI / GI pipes are passing through shall be sealed with epoxy cement mortar.NOTE:- (i) The sunken slab sloped towards outer face so as the drain the water to GI spout pipe.(ii) Coving shall be provided at the junction of slab with the wall.(iii) Nahni trap shall be 10 mm below finished floor level. Ensure the drain of pipe dia is larger than the Nahni trap size. (iv) The outer end of the spout should be chamfered.
26Providing and laying non skid ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS:15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on and including 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kilo gram per square metre including pointing the joints with white cement and matching pigments etc., complete all as specified and as directed .
27Providing and fixing 1st quality ceramic glazed wall tiles of size 450x300 mm conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over and including 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kilo gram per square metre, including pointing in white cement mixed with pigment of matching shade complete all as specified and as directed .
28Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, W.C. pan with ISI marked white solid plastic seat and lid complete all as specified and as directed.
29Providing and fixing white vitreous china water closet squatting pan (Indian type) Orissa pattern W.C. Pan of size 580x440 mm along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in-Charge.
30Supply and fix in repair of health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect and as specified.
31Providing and fixing chrome plated two way bib cock of 15 mm nominal bore of approved quality conforming to Indian Standards and weighing not less than 690 grams.
32Supplying and fixing in repairs of 15 mm dia stop valve, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete in all respect and as specified.
33Providing and fixing in repair of chrome plated urinal cock / spreader of approved quality and 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 grams.
34Providing and fixing of uplasticised PVC connection pipe, with brass unions, 45 cm length 15 mm nominal bore complete all as specified and as directed.
35Providing and fixing vitreous china urinal partitions with necessary fittings as per direction of Engineer-in-Charge.
36Supplying and fixing vitreous china counter top / counter shunk wash basin in circular / oval shape, white, of size 560x400mm placed on granite platform as per direction of Engineer-in-Charge.
37Supplying and fixing in repairs of 15 mm dia fancy pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed .
38Providing and fixing in repairs vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) only including connections to flushing pipe and outgoing pipes fixed
39Providing and fixing flexible P.V.C. waste pipe of 32 mm dia. for sink or wash basin in repairs including P.V.C. waste fittings complete all as specified and as directed.
40Providing and fixing of chrome plated waste coupling of 32 mm dia and 125 mm length for wash basin and sink, of approved quality and colour.
41Dismantling 15 to 40 mm dia G.I./PVC pipe exposed on wall including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer- in-Charge.
42Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of size 25 mm internal dia. for external work, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
43Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of 15 mm dia bore concealed work, including cutting chases and making good the walls, etc., having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
44All as per item No.38 here-in-before but of size of 20 mm internal dia exposed work.
45Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete as per direction of Engineer in Charge.
46Providing and fixing 18 mm thick granite stone slab, colour black, cherry/ruby, red, gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of area of slab over 0.50 square metre, approved shade, colour and texture laid over and including 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish, etc., complete at all levels as specified and as directed by the Engineer-in-Charge.
47Providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc., including moulding, rubbing and polishing of cut edges etc. complete all as specified and as directed.
48Supplying and fixing tubular towel rail of 20mm dia brass chromium plated, D type, 60cm long between flanges complete all as specified and as directed .
49Dismantling doors, windows and clerestory windows (steel or wood) shutter of area upto 3 square metres and below including chowkhats, architrave, holdfasts, guard bars etc. complete and stacking within 50 metres lead as specified and as directed.
50Providing and fixing factory made single extruded WPC frame of size 45 x 70 mm, (Wood Polymer Composite) solid door / window / Ceosetory windows and other Frames / Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 grams) fabricated with miter joints after applying PVC solvent cement and screwed with full body threadedstar headed SS screws having minimum frame density of 750 kilogram per cubic metre, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position
51with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. NOTE :- (i) M.S hold fast/lugs or SS dash fasteners shall be paid for separately.(ii) For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made .
52Providing and fixing factory made single extruded WPC 30 mm thick (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 grams) having minimum density of 650 kilogram per cubic metre and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. NOTE:- Stainless steel butt hinges and necessary S.S screws shall be paid separately.
53Supplying and fixing in repair of PVC (SWR) floor trap, type 'B', 75 mm plain with grating including jointing with solvent cement
54Taking down eaves gutters, PVC/CI/AC pipes as in rainwater pipes or soil pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
55Supplying and fixing PVC (SWR) pipes 75 mm, type 'B', single socketed including bends,elbows and all fittings in any length with rubber ring joints, fixed to walls and laid in trenches.
56Supplying and fixing PVC (SWR) pipes 110 mm, type 'B', single socketed including bends,elbows and all fittings in any length with rubber ring joints, fixed to walls and laid in trenches.
57Providing and fixing on wall face unplasticised rigid PVC rain water single socketed pipes, 110 mm dia., conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
58Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
59Providing and fixing powder coated (minimum thickness of powder coating 50 micron) aluminium work for fixed portion for doors, windows, ventilators and partitions for fixed portion with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. NOTE:- Glazing, paneling and dash fasteners to be paid for separately.
60Providing and fixing powder coated (minimum thickness of powder coating 50 micron) aluminium work for shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required.NOTE:- Fittings shall be paid separately.
61Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc., with float glass panes of 4.0 mm thickness (weight not less than 10 kilo gram per square metre) with EPDM rubber / neoprene gasket etc., complete as per the architectural drawings and the directions of Engineer-in-Charge . NOTE:- Cost of aluminium snap beading shall be paid in basic item.
62Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
63Material and labour for 10 mm thick cement plaster 1:4 (1 cement: 4 fine sand) finished with a neat cement, complete all as specified and as directed.
64Material and labour for 5 mm thick cement plaster on ceiling with 1:3 (1 cement: 3 fine sand) finished with a neat cement, complete all as specified and as directed.
65Material and labour for white washing with lime to give an even shade on old work (two or more coats) complete all as specified and as directed
66Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for beyond 19 km lead upto 20 km for all lifts, complete as per directions of Engineer-in-Charge.
67Material and labour for 75mm thick cement concrete, type B2,1:2:4 using 20mm graded aggregate as plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
68Material and labour for 25 mm thick plain cement concrete, type B0, 1:2:4 using 12.5mm graded aggregate as in bedding, finished fair and even complete all as specified and directed.
69Material and labour for 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand), finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
70Material and labour for 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand), finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
71Material and labour for 6 mm thick cement plaster mix 1:3 (1 cement: 3 fine sand) finishing the ceiling surface even and smooth without using extra cement complete all as specified and directed.
72Providing and laying double charge vitrified tile polished/matte finish coloured of size 600x600 mm in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid on and including 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kilo gram per square metre including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
73Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete all as specified and directed.
74Providing and applying wall putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
75Distempering with 1st quality two coats acrylic oil bound distemper on old work surfaces (old prepared wall surface) (ready mix) having VOC content less than 50 grams per litre of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour.
76Removing dry or oil bound distemper / exterior paint/ cement base paint, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc., and finishing walls with acrylic smooth exterior paint of required shade on old work (old surface) (two or more coat applied @ 1.67 litre per 10 square metre over and including priming coat of exterior primer applied @ 2.20 kilogram per 10 square metre) including applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content with water thinnable cement primer on wall surface having VOC content less than 50 grams per litre, complete all as specified.
77Providing and fixing fly proof wire gauze stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm, nuts and bolts complete.
78Providing and fixing anodised aluminium grill (anodised transparent shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as per requirement and direction of Engineer-in-Charge.NOTE:- Only weight of grill to be measured for payment.
79Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kilo gram and door width upto 700 mm), with necessary accessories and screws etc., complete all as per requirement and direction of Engineer-in-Charge.
80Providing and fixing float glass panes of 5.0 mm thickness (weight not less than 10 kilogram per 10 square metre) in aluminium door, window, ventilator shutters and partitions, etc., with EPDM rubber / neoprene gasket, etc., complete as per the architectural drawings and the directions of Engineer-in-Charge . NOTE:- Cost of aluminium snap beading shall be paid in basic item.
81Design supply and installation of suspended spider glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The suspended system held with spider fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel spider and bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to slab/beams by means of SS- 316 Grade stainless steel brackets, anchor bolts and at the bottom using SS channel of 50x25x2 mm using fastener and anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc.
82The joints between glass panels (6 to 8 mm) and gaps at the perimeter and in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof and dust proof and providing reception counter with small access door.The rate shall include all design, engineering and shop drawing including approval from structural designer, labour, T and P, scaffolding, other incidental charges including wastage, enabling temporary services, all fitting fixers, nut-bolts, washer, buffer plates, fastener, anchors, SS channel, laminated glass, etc., complete all. For the purpose of payment, actual elevation area of glazing including thickness of joints and the portion of glass panel inside the SS channel shall be measured.
83Excavating in post holes in soft / loose soil (or similar holes) each exceeding 0.5 cubic metre, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
84Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
85Material and labour for structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as per direction of Engineer-in-Charge.
86Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
87Material and labour for prepartion of new steel surfaces and applying two coats of synthetic enamel paint of approved brand and manufacture of required colour over coat of red oxide, any description not otherwise described over 10cm width or girth complete all as specified and directed.
88Excavating in post holes in hard/dense soil (or similar holes) each exceeding 0.5 cubic metre, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,all complete as per direction of Engineer-in-Charge.
89Material and labour for steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works and applying a priming coat of approved steel primer using structural steel etc. as required. as per direction of Engineer - in - charge.
90Supply and fix venetian blinds, vertical type, 100 mm slot width of approved fabric and powder coated aluminium top railsetc complete all as specified, including dismantlilng old damaged one completecomplete all as specified and as directed. NOTE:- The colour,design, shade and make shall be as approved by GE.
91Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), in flooring, including finishing complete all as per direction of Engineer-in - Charge.
92Material and labour for hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface as per direction of Engineer-in-Charge.
93Material and labour for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
94Material and labour for forming contraction (dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed .
95Providing and laying factory made precast concrete solid blocks of 200 mm thickness of grade M10 made of construction and demolition waste from approved manufacturer in superstructure upto plinth level, in cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed by Engineer-in-Charge.
96Finishing walls with water proofing cement paint of required shade on new work (two or more coats applied @ 3.84 kilo gram per 10 square metre) complete all as specified and as per direction of Engineer-in -Charge.
97Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.
98Material and labour for 25 mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished, including cement slurry, but excluding the cost of nosing of steps etc. complete all as specified and as directed.
99Providing and laying non skid ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as white,ivory, grey, fume red brown, laid on and including 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kilogram per square metre including pointing the joints with white cement and matching pigment etc., complete all as specified and as directed.
100Providing and fixing 1st quality coloured glazed ceramic tiles of size 450mm x 300mm / 450mm x 350mm , in dado/skirting etc. conforming to IS : 15622 of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over and including 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kilogram per square metre including pointing in white cement mixed with pigment of matching shade complete all as specified and directed.
101Providing and fixing white vitreous china battery based infrared sensor operated urinal of approved make/brand having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-Charge.
102Providing and fixing 15 mm nominal bore chrome plated brass battery based infrared sensor operated pillar cock of approved make/brand, having foam flow technology.
103Providing and fixing vitreous china table top wash basin of approved make/brand of size 595x420x200mm, weight 10.80 kg, as per manufacturers specification and direction of Engineer-in-Charge.
104Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
105Providing and fixing of curve glass urinal partition straight shape dimenstion 450x900mm all as per manufacturers specification and direction of Engineer-in-charge.
106Removing excavated material exceeding 1.50 km but not exceeding 5 km and depositing where directed complete all as specified and directed.
107Material and labour for centering and shuttering including strutting, propping etc., and removal of form for suspended floors, roofs, landings, balconies and access platform (steel shuttering) in all respect as per directions of Engineer-in-Charge.
108Providing thermo-mechanically treated bars of grade Fe-500D or more as in steel reinforcement for reinforced concrete work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
109Providing and laying in position reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in all work up to plinth level, excluding the cost of centering, shuttering, finishing NOTE:- Reinforcement shall be measured and paid separately.
110Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of size 40 mm internal dia.(concealed on wall), exposed on wall, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
111Material and labour for 10 mm thick internal plaster in cement mortar 1:6 on other than fair faces of walls, finishing the surfaces even and smooth without using extra cement.
112Material and labour for preparation of plastered or unplastered surface and distempering 02 coats with oil bound washable distemper of approved brand and manufacture to give an even shade over and including water thinnable priming coat with cement primer all as specified and directed by Engineer in Charge.
113Material and labour for distempering 01 coat with oil bound washable distemper of approved brand, shade and manufacture to give an even shade including primer.
114Supply and fix 15mm bib taps of approved make/brand, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
115Providing and fixing chrome plated brass stop cock of 15 mm nominal bore (concealed) in repairs of standard design and of approved make conforming to IS:8931, complete all as specified and directed.
116Supply and fix PVC (SWR) gully trap 125/110 mm, type 'B', setting and jointing with solvent cement.
117Providing and fixing stainless steel towel rail complete with brackets fixed to wall with chrome plated brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 grams.
118Dismantling false ceiling, boarding etc., complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as specified and directed by Engineer in Charge.
119Providing and fixing mineral fibre beveled tegular edged ceiling tiles 595 x595mm,16 mm thick of approved texture in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per square metre including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls / partitions on a perimeter wall angle pre-coated steel of size (24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with
12025 mm long dry wall screws @ 230 mm interval and laying 16mm thick mineral fibre beveled tegular edged ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Make : Armstrong or equivalent.
121Providing and fixing mirror of superior glass (of approved quality) of rectangular shape and size of 1500x760 mm with plastic moulded frame of approved make.
122Supply only CPVC elbow, tee, collar, union of size 20 mm, complete all as specified and as directed.
123Supply only CPVC elbow, tee, collar, union of size 25 mm, , complete all as specified and as directed.
124Material and labour for 15 mm thick plaster in cement mortar 1:4 on fair faces of walls , finishing the surfaces even and smooth without using extra cement. NOTE :- Work shall be executed for buildings of height upto 20m with necessary scaffolding.
125Material and labour for 15 mm cement plaster in fine sand on the rough side of single or half brick wall or concrete surface of mix 1:6 (1 cement: 6 fine sand).
126Supply only liquid water proofing compound (Mix 200ml water proofing compound with every 50 kg of cement) complete all as specified and as directed.
127Material and labour for finishing walls of new work with 100% premium acrylic external emulsion paint having VOC less than 50 gram per litre and UV resistance as per IS 15489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives (two or more coats) applied @ 1.43 litre per 10 sqare metre over and including priming coat of exterior primer applied @ 0.90 litre per 10 sqare metre complete all as specified and as directed. NOTE :- Work shall be executed for buildings of height upto 20m with necessary scaffolding.
128Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.NOTE :- Work shall be executed for buildings of height upto 20m with necessary scaffolding.
129Material and labour for applying 1.00 to 1.50mm thick wall care putty on walls for preparation of even and smooth surface at any location including filling the holes of nails and scratches preparation of surfaces complete all as specified and as directed.
130Material and labour repairing cracks in plaster up to 5mm wide, by cutting a V-groove, filling with and finishing with polymer-modified, paintable acrylic filler (Dr. Fixit or as approved by GE), including scaffolding, cleaning, and making good complete all as specified and as directed. MAKE:- Dr. Fixit (Pidilite- Crack-X/Sika Latex/ Asian Paints (Smart Care Range)/ Berger(Home Shield)/ Sika(Nitobond)/ Fosroc(Nitobond).
131Material and labour applying two coats of exterior emulsion weather proof paint of approved tint over a coat of primer, including removal of existing treatment on wall surfaces including cornices, plasters, etc., by scrapping down with wire brushes and washing down and removing existing loose finishes, particles, etc., complete all as specified and as directed. NOTE :- Work shall be executed for buildings of height upto 15 metre including all necessary scaffolding.
132Material and labour applying one coat of exterior emulsion weather proof paint of approved tint on old wall surfaces including cornices, plasters, etc., by scrapping down with wire brushes, washing down and removing existing loose finishes, particles, etc., complete all as specified and as directed. NOTE:- Work shall be executed for buildings of height upto 15 metre including all necessary scaffolding.
133Material and labour for french polishing on surfaces of any description, width or girth cleaning and preparing the surfaces including a coat of wood filler on old works with two or more coats complete all as specified and as directed.
134Material and labour for painting one or more coats with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade on old work of wood or steel surfaces.
135Material and labour for finishing walls with textured paint of required shade (two or more coats applied @ 3.28 litres per 10 square metre) over and including priming coat of primer applied @ 2.20 kilo gram per 10 square metre, complete all as specified and as directed.
136Supplying and fixing in repairs for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates, etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
137Providing and fixing floor/wall mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket, etc., including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
138Supply and fix in repair angle valve 15mm bore chromium plated cast copper alloy, screwed down high pressure with capstan head and flange complete all as specified and directed.
139Supply and fix in repair angle valve two way 15mm bore brass chromium plated screwed down high pressure with capstan head and flange complete all as specified and directed.
140Supply only pillar tap brass chromium plated, with fancy type, screwed down high pressure, with or without letter 'Hot' or cold with long screwed shanks and fly nut screwed for iron pipe of bore 15mm , complete all as specified and directed by Engineer-In-Charge.NOTE:- Weight of pillar tap shall not be less than 665 grams.
141Supply only brass chromium plated bib cock 2 way double handle with flange of approved make / brand complete all as specified and directed.
142Supply only brass chromium plated bib tap of approved make / brand, 15 mm bore pipe, fancy type, any description complete all as specified and directed.
143Supply and fix PVC (SWR) pipes single socketed 110 mm bore, type 'B', fixed in walls including all clamps and shoes, all as specified and directed.
144Supply and fix PVC (SWR) pipes single socketed 75 mm bore, type 'B', fixed in walls including all clamps and shoes, all as specified and directed.
145Supply and fix 110 mm PVC (SWR) bends, type 'B', any radius complete all as specified and as directed.
146Supply and fix 75 mm PVC (SWR) bends,type 'B', any radius.complete all as specified and as directed.
147Supply and fix in repairs brass chromium plated 32 mm dia, waste coupling for wash basin and sink, of approved quality and colour, complete all as specified and as directed.
148Supply and fix in repairs brass chromium plated 40 mm dia, waste coupling for wash basin and sink, of approved quality and colour, complete all as specified and as directed.
149Supply and fix in repair of SS grating 125 mm dia round (with holes / without holes as per site condition) fixed on floor / nahani trap fixed with cement mortar complete all as specified and directed.
150Supply and fix PVC connections 15mm size with PTMT nuts of length 600mm, fixed as in repairs.
151Taking down carefully unseviceable aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc , removing all material for reuse/ issued under schedule of credit and making good the disturbed surface as the existing one, complete all as directed.
152Taking down old sub main wiring of any type and size, complete all as specified and directed .
153Material and labour for wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed, medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(a) One light point controlled by one way switch
154Material and labour for wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed, medium class PVC conduit as required.(a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wireNOTE: Two runs of 4 sq.mm copper cable, one run of earth wire of 4 sq.mm copper cable and PVC conduit of suitable size shall be measured and paid as one running metre.
155Material and labour for wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed, medium class PVC conduit as required.(a) 4 X 10 sq. mm + 2 X 6 sq. mm earth wireNOTE: Four runs of 10 sq.mm copper cable, two runs of earth wire of 6 sq.mm copper cable and PVC conduit of suitable size shall be measured and paid as one running metre.
156Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(a) 4 X 16 sq. mm + 2 X 6 sq. mm earth wireNOTE: Four runs of 16 sq.mm copper cable, two runs of earth wire of 6 sq.mm copper cable and PVC conduit of suitable size shall be measured and paid as one running metre.
157Supply and fix ceiling rose, surface backelite, two to three terminal complete all as directed.
158Supplying and fixing LED light fitting 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified as directed.
159Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
160Supply and fix exhaust fan, steel body AC single phase 230V of size 300 mm sweep 900RPM with, blades, and frame and louvers including cutting the wall of stone/ brick masonery as per the size of exhaust fan including grouting the bolts, nuts, etc., for fixing necessary connection with three core flexible wire from and making good the distrubed surface as the existing one, exhaust fan to ceiling rose complete all as directed.
161Supplying and fixing surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of 8 way (4 + 12), double door type of sheet steel, dust protected, duly powder painted, inclusive of 125 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . NOTE:- Vertical type MCB TPDB is normally used where 3 phase outlets are required.
162Providing and fixing following rating and breaking capacity and 4 pole MCCB with hermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections of size 125 A to 160A, 35KA, 50Hz, 415V, four phase MCCB etc. as required.
163Supplying and fixing SP 5A to 32A rating 240/415 V, 10KA 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete testing and commissioning, etc., as required.
164Material and labour for earthing complete with galvanised iron plate electrode 600 x 600 x 6.00 mm thick GI earthing lead burried directly in ground vertically to a depth not less than 2.25 metre deep below GL with the top edge of the plate at a depth not less than 1.5 metre from below normal GL, connected to and including galvanised iron strip 32x6 mm as earthing lead by means of nuts, bolts, washers, checknuts of galvanised iron and connected to earthing test point all as shown in electric plate no. 3 of SSR Part l of 2010 and as specified or indicated and testing on completion including excavation / earth work in any type of strata PCC (1:3:6), type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM)) weight not less than 4 kilo gram per square metre, cast iron frame, funnel with wire mesh, including GI earth strip with GI protection pipe of 40mm medium grade 7.5 meter long, etc., complete and testing on completion all as specified and as directed.
165NOTE :(i) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50 metre, PCC pit, funnel and RCC cover plate.(ii) GI strip above 7.5m will be measured and paid separately.(iii) Earth resistance not exceeding 1.0 ohm.
166Material and labour for point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 25 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I, ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes, etc., fixed surface/ concealed/ recessed in wall or ceiling, etc., including 1.5 sq.mm PVC insulated but unsheathed multistranded copper conductor FRLSH cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified, etc., for one light point controlled by one, one way switch 5 Amps
167Material and labour for point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 25 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I, ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes, etc., fixed surface/ concealed/ recessed in wall or ceiling, etc., including 1.5 sq.mm PVC insulated but unsheathed multistranded copper conductor FRLSH cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified, etc., for :-(a) One Ceiling fan point/wall fan/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
168Material and labour for sub main wiring single core, PVC insulated, unsheathed, multistranded copper conductor cable, 1100 Volts, FRLSH grade, ISI marked, drawn through and including suitable PVC non matallic rigid conduit with accessories fixed on walls / roofs / floors / ceiling, etc., and connecting terminal ends including one run of single core, PVC insulated, unsheathed, multistranded copper conductor cable, green in colour, 1100 Volts, FRLSH Grade as earth continuity conductor complete all as specified and as directed(a) 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wireNOTE: Two runs of 2.5 sq.mm copper cable, one run of earth wire of 2.5 sq.mm copper cable and 25 mm dia PVC conduit shall be measured and paid as one running metre.
169Material and labour for sub main wiring single core, PVC insulated, unsheathed, multistranded copper conductor cable, 1100 Volts, FRLSH grade, ISI marked, drawn through and including suitable PVC non matallic rigid conduit with accessories fixed on walls / roofs / floors / ceiling, etc., and connecting terminal ends including one run of single core, PVC insulated, unsheathed, multistranded copper conductor cable, green in colour, 1100 Volts, FRLSH Grade as earth continuity conductor complete all as specified and as directed(a) 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire Note: Two runs of 2.5 sq.mm copper cable, one run of earth wire of 2.5 sq.mm copper cable and 25mm dia PVC conduit shall be measured and paid as one running metre.
170Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 Amps modular socket outlet and 5/6 A modular switch, connections etc as required.
171Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and 15/16 Amps modular socket outlet and 15/16 A modular switch, connections etc., as required.
172Supplying and fixing LED batten luminaire not less than 20 watt fitting 4’ long with white powder coated housing and frame in CRCA sheet, high efficiency LED grade diffuser, electronic driver duly wired upto terminal block CRI>80, LED colour temperature -5700k, IP20, 50000 burning hours as per L70 criteria, ambient temperature – 0 to 50° C, Driver efficiency >85%, THD<10%, PF>0.95, sure protection in CM-3KV, multistage isolated constant current, constant voltage operated driver with range 150-270V AC and safety, extra low voltage, safe level<60V DC as per IEC standard including batten/suspension system complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed.
173Material and labour for point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I, ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes, etc., fixed surface/ concealed/ recessed in wall or ceiling, etc., including 1.5 sq.mm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified, etc., for one light /fan point controlled by one switch complete all as specified.
174Supply and fixing exhaust fan of sweep 150/200 mm, made of plastic body complete with louvers shutter, voltage 230V, 50 Hz, speed RPM 1200, copper winding including making all connections and fixing arrangements complete all as specified and all as directed by Engineer-in-Charge.
175Supply and fix exhaust fan steel body, of size 300 mm sweep with AC single phase 230/ 240 V, speed 1400 RPM with complete louver as required at site with all fixing arrangment required at site, finishing work complete with all connections all as specified and directed by Engineer-in-Charge.
176Supply & fixing recess mounted 2'x2' LED fitting, full lit luminaire with glare free uniform illumination with longer life suitable for 36 watt, including all fixing arrangement and taking down of old unserviceable, complete all as specified and directed.
177Material and labour for earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc., with charcoal/ coke and salt as required and direction of Engineer-in-Charge.
178Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc., as required (jointing shall be done by overlapping and with 2 eachs of brass nut bolt and spring washer spaced at 50mm) complete all as specifed and directed.
179Supply and fix MCCB enclosure suitable for 4 pole, 415V of rating 100 Amp inclduing making connection complete all as specified and directed.
180Providing and fixing of rating and breaking capacity 4 pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 36 KA inclduing connection, complete all as specified and direted.
181Supply and fixing change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps including connection, etc., complete all as specified and directed.
182Supply and making end termination with brass compression gland and brass lugs of size 4x16 sq.mm ( 28 mm ) PVC insulated and PVC sheathed conductor cable of 1.1 grade complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56446454
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.30 Lakhs
LAST DATE 25-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addition/Alteration To Store Room, Security Room, Sentry Post, P-40, P-19 And Rcma Building, Provision Of Temporary Shelter, Input Power Supply To Test Cell And Vertical Blinds At Gtre, Cabs And Cemilac Under Ge (I) R&D (East), Bangalore.
Basic Detail
Tender No 8694/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 13 Jul 2026
Submission Date 25 Jul 2026
Open Date 27 Jul 2026
Finance
Tender Value 49.30 Lakhs
Tender Fee 500
EMD 98600
Exemption Available
Document List
2699acb3-acef-476d-8d43-120965359070.html
8694Tender.pdf
BOQ_871702.xls
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

2699acb3-acef-476d-8d43-120965359070.html

pdf

8694Tender.pdf

xls

BOQ_871702.xls

pdf