Tender For Repair And Maintenance Of Lt Ug Cables, Distribution Network, Ascr Conductors, Guard Wire, Electric Poles And Allied Work At Afs Under Ge (Af) Jorhat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Aug 2026
4 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jorhat → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Lt Ug Cables, Distribution Network, Ascr Conductors, Guard Wire, Electric Poles And Allied Work At Afs Under Ge (Af) Jorhat
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of ACSR conductors, line seperator, service feeder or distribution span from the existing LT over head lines etc. complete all as specified and as directed. |
| 2 | Dismantling and taking down insulators, any type and size from the existing LT line complete all as specified and as directed |
| 3 | Dismantling and taking down cross arms or MS channel or angle section, etc. from the existing LT line and transformer, etc. and setting aside for reuse or removal complete all as specified and as directed. |
| 4 | Dismantling LT stay assembly of any size complete all as specified and as directed. |
| 5 | M&L for drawing aluminium conductor, steel reinforced of any size conductor including fixing by binding wire and provision of jumpers, etc complete all as specified and as directed. |
| 6 | M&L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and as directed. |
| 7 | M&L for shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, and one galvanised iron nut, 100mm height, 115mm dia for 1100 volts grade complete all as specified and as directed. |
| 8 | M&L for stay assembly having stay rod diameter 16mm complete with accessories all as shown in Electrical Plate No.1 (SSR Part-I) complete all as specified and as directed. Note: Stay clamps loop type insulator, excavation & earth work and concrete work shall be measured and paid for seperately under relevant items. |
| 9 | M&L for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections, including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat primerand one finishing coat of aluminium paint complete all as specified and as directed. |
| 10 | S&F PVC line seperator in between two conductors spiral type complete all as specified and as directed. |
| 11 | Trimming branches of trees upto 1m from O/H conductor and removing the same at a distance upto 50m complete all as specified and as directed. |
| 12 | Dismantling of steel tubular pole of any size from bottom by demolition of concrete complete all as specified and as directed. |
| 13 | S&F LT steel tubular swaged poles complete, 9.0m long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 complete all as specified and as directed.Note : Necessary excavation & earth work including PCC work shall be measured and paid seperately. |
| 14 | Excavating in trenches not exc. 1.50m wide and not exc. 1.50m in depth, for taking out and laying of cables, etc. and getting out in soft/loose soil complete all as specified and as directed. |
| 15 | All as per Serial Item No. 14.00 here-in-before but excavation in trenches exc. 1.5m wide and n. exc. 3.0m in depth . |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil complete all as specified and as directed. |
| 17 | Removing excavated materials (soils) not exc. 50.00m and depositing where directed at a level not exc. 1.50m above the starting point in soil complete all as specified and as directed. |
| 18 | Horizontal boring for passing GI protection pipe upto 100mm bore (dia), under road / foot path, not exc. 10m in a single length complete all as specified and as directed. |
| 19 | M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness or for sand filling on ground or in foundations including watering and consolidation complete all as specified and as directed.Note : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for. |
| 20 | Taking down/out unserviceable or serviceable LT UG cables of nominal cross sectional area 300 sq.mm, 3.5 core and connections including bricks, GI pipes, etc. of any descriptions, laid in trenches and/or fixing with walls/poles including segregating of serviceable materials viz bricks, cables, GI pipes, etc. and keep in safe custody for re-use complete all as specified and as directed.Note : Earth Work shall be Measured and Paid for separately under relevant Items. |
| 21 | All as per Serial Item No. 20 here-in-before but of nominal cross sectional area 185 Sq.mm, 3.5 core. |
| 22 | All as per Serial Item No. 20 here-in-before but of nominal cross-sectional area 120 Sq.mm, 3.5 core. |
| 23 | All as per Serial Item No. 20 here-in-before but of nominal cross-sectional area 95 Sq.mm, 3.5 core. |
| 24 | All as per Serial Item No. 20 here-in-before but of nominal cross-sectional area 70 Sq.mm, 3.5 core. |
| 25 | All as per Serial Item No. 20 here-in-before but of nominal cross-sectional area 50 Sq.mm, 3.5 core. |
| 26 | All as per Serial Item No. 20 here-in-before but of nominal cross-sectional area 35 Sq.mm 3.5 core. |
| 27 | All as per Serial Item No. 20 here-in-before but of Nominal Cross-Sectional Area 25 Sqmm 4 Core. |
| 28 | All as per Serial Item No. 20 here-in-before but of nominal cross-sectional area 16 Sq.mm 4 Core. |
| 29 | All as per Serial Item No. 20 here-in-before but of Nominal Cross-Sectional Area 10 Sqmm 2 core. |
| 30 | Supply and laying or fixing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy Duty) with aluminium conductor, 1100 volts grade, nominal cross-sectional area 300 sq.mm, 3.5 core and testing, including crass compression cable gland, terminal lug, etc. complete all as specified and as directed. |
| 31 | All as per Serial Item No. 30 here-in-before but of nominal cross-sectional area 185 Sq.mm, 3.5 core. |
| 32 | All as per Serial Item No. 30 here-in-before but of nominal cross-sectional area 120 Sq.mm, 3.5 core. |
| 33 | All as per Serial Item No. 30 here-in-before but of nominal cross-sectional area 95 Sq.mm, 3.5 core. |
| 34 | All as per Serial Item No. 30 here-in-before but of nominal cross-sectional area 70 Sq.mm, 3½ core. |
| 35 | All as per Serial Item No. 30 here-in-before but of nominal cross-sectional area 50 Sq.mm, 3½ core. |
| 36 | All as per Serial Item No. 30 here-in-before but of nominal cross-sectional area 35 Sq.mm, 3½ core. |
| 37 | All as per Serial Item No. 30 here-in-before but of nominal cross-sectional area 25 Sqmm, 4 core. |
| 38 | All as per Serial Item No. 30 here-in-before but of nominal cross-sectional area 16 Sq.mm, 4 core. |
| 39 | All as per Serial Item No. 30 here-in-before but of nominal cross-sectional area 10 Sq.mm, 2 core. |
| 40 | Re-laying/Fixing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy Duty) with aluminium conductor, 1100 volts grade, nominal cross-sectional area 300 Sq.mm, 3½ core including brass compression cable gland, terminal lug, etc. complete all as specified and as directed.Note (For Item No. 40 to 48) : Old serviceable UG cable obtained from Serial Item No. 20 to 29 to be re-used. |
| 41 | All as per Serial Item No. 40 here-in-before but of nominal cross-sectional area 185 Sq.mm, 3.5 core. |
| 42 | All as per Serial Item No. 40 here-in-before but of nominal cross-sectional area 120 Sq.mm, 3.5 core. |
| 43 | All as per Serial Item No. 40 here-in-before but of nominal cross-sectional area 95 Sq.mm, 3.5 core. |
| 44 | All as per Serial Item No. 40 here-in-before but of nominal cross-sectional area 70 Sq.mm, 3½ core. |
| 45 | All as per Serial Item No. 40 here-in-before but of nominal cross-sectional area 50 Sq.mm, 3½ core. |
| 46 | All as per Serial Item No. 40 here-in-before but of nominal cross-sectional area 35 Sq.mm, 3½ core. |
| 47 | All as per Serial Item No. 40 here-in-before but of nominal cross-sectional area 25 Sq.mm, 4 core. |
| 48 | All as per Serial Item No. 40 here-in-before but of nominal cross-sectional area 16 Sq.mm, 4 core. |
| 49 | M&L for sub-class 'B' bricks, laid breadth-wise along the axis of cable laid in trenches over sand cushion for UG cable protection complete all as specified and as directed. |
| 50 | Re-laying only old bricks in trenches for under ground cable protection complete all as specified and as directed.Note : Serviceable bricks obtained from Item No. 20 here-in-before shall re-use. |
| 51 | M&L for cutting the road/hard standing and making good disturbed surface by using PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) for the fixing the pipe complete all as specified and as directed. |
| 52 | Taking down/out unserviceable GI / HDPE/Polyethylene flexible pipes of any descriptions, laid in trenches and/or fixing with walls/poles complete all as specified and as directed. |
| 53 | S&F galvanised iron pipe 80mm bore (dia) ‘light grade’ for protection of UG cable, laid in floors/road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc. complete all as specified and as directed. |
| 54 | All as per Serial item No. 53 here-in-before but 50mm bore (dia) ‘light grade’ GI pipe. |
| 55 | All as per Serial item No. 53 here-in-before but 40mm bore (dia) ‘light grade’ GI pipe. |
| 56 | All as per Serial item No. 53 here-in-before but 32mm bore (dia) ‘light grade’ GI pipe. |
| 57 | M&L for repair of LT feeder pillar box complete with complete dismantling of burnt out cable connections, bus-bars, MCCBs, etc. and painting to external surfaces with one coat of synthetic enamel paint of approved grade, refixing of bus-bars, replacement of epoxy cast busbar insulators, serviceable MCCBs, all cable connection from busbar to terminals at both ends etc. including patch repair with electric welding for replacement of hinges, refixing of broken doors, replacement of locking arrangement with sliding bolts including PCC for reconstruction of foundation/coping, etc. complete all as specified and as directed. Note : MCCBs / Cable connector required for replacement and required PCC for reconstruction of foundation/coping will be measured & paid separately. |
| 58 | M&L for cable connector of length 0.5m, made out of 50 Sq.mm multistranded copper conductor single core. PVC inner sheathed unarmoured cable including copper lugs, copper nut bolts, etc. complete all as specified and as directed. |
| 59 | S&F aluminium lugs to replace the existing panel boards / transformer, etc. of following sizes : - |
| 60 | 25 sq.mm |
| 61 | 35 sq.mm |
| 62 | 50 sq.mm |
| 63 | 70 sq.mm |
| 64 | 95 sq.mm |
| 65 | 120 sq.mm |
| 66 | 150 sq.mm |
| 67 | 185 sq.mm |
| 68 | 240 sq.mm |
| 69 | 300 sq.mm |
| 70 | S&F brass cable gland single compression type complete with check nut to replace the existing panel boards/transformer etc.of following sizes : -Make : DOWELLS/UML/ DOLLARS |
| 71 | 25 sq.mm, 4 core. |
| 72 | 35 sq.mm, 3.5 core. |
| 73 | 50 sq.mm, 3.5 core. |
| 74 | 70 sq.mm, 3.5 core. |
| 75 | 95 sq.mm, 3.5 core. |
| 76 | 120 sq.mm, 3.5 core. |
| 77 | 150 sq.mm, 3.5 core. |
| 78 | 185 sq.mm, 3.5 core. |
| 79 | 240 sq.mm, 3.5 core. |
| 80 | 300 sq.mm, 3.5 core |
| 81 | S&F digital AC ammeter with 3.5 digit display and with built in selector switch, type 3 PH, range 5 amp direct and with CT 200/5 A, size 96mmx96mm, accuracy class 1.0 complete all as specified and as directed. |
| 82 | S&F digital AC voltmeter 3.5 digit display and with built in selector switch, type 3 PH, range 30-600 volts direct, size 96mmx96mm, accuracy class 1.0 complete all as specified and directed. |
| 83 | S&F 4 way cable connector complete all as specified and as directed.Make : ACDC/RAMANUT |
| 84 | M&L straight through (heat shrink) cable joint kit including jointing materials for making joints of UG electric cable 1100 volts grade, heavy duty with PVC/XLPE insulated aluminium stranded conductor, nominal cross-sectional area exc. 25 Sq.mm but not exc. 50 Sq.mm, 3.5/4 core and testing complete all as specified and as directed. |
| 85 | All as per Serial Item No. 64 here-in-before but of nominal cross-sectional area exc. 70 Sq.mm but not exc. 120 Sq.mm, 3½ core. |
| 86 | All as per Serial Item No. 64 here-in-before but of nominal cross-sectional area exc. 150 Sq.mm but not exc. 185 Sq.mm, 3½ core. |
| 87 | All as per Serial Item No. 64 here-in-before but of nominal cross-sectional area exc. 240 Sq.mm but not exc. 300 Sq.mm, 3½ core. Please Enable Macros to View BoQ information |
| 88 | All as per Serial Item No. 64 here-in-before but of nominal cross-sectional area exc. 240 Sq.mm but not exc. 300 Sq.mm, 3½ core. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender