Tender For Comprehensive Maintenance Of B/R And E/M Works Like Repair Of Generator Room, Shed, Foundation, Approach Path, Hard Standing And Security Fencing, Routine And Periodic Repair And Maintenance Of Installed Dg Sets Of Various Capacities Inclu

Issued by Statutory Bodies & Commissions/Committees · Raigad, Maharashtra
Tender Value
92 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
27 days left
EMD
1.63 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Comprehensive Maintenance Of B/R And E/M Works Like Repair Of Generator Room, Shed, Foundation, Approach Path, Hard Standing And Security Fencing, Routine And Periodic Repair And Maintenance Of Installed Dg Sets Of Various Capacities Including Diesel Engine, Alternator, Control Panel And Cooling And Exhaust System, Fuel System, Lubrricating System, Battery Charger And Main Assembly Frame Etc At Explosive And Non Explosive Areas Inside Nad At Naval Station Karanja

BOQ

Name of Work:- COMPREHENSIVE MAINT OF B/R AND E/M WORKS LIKE REPAIR OF GENERATOR ROOM, SHED, FOUNDATION, APPROACH PATH, HARD STANDING AND SECURITY FENCING, ROUTINE AND PERIODIC REPAIR AND MAINTENANCE OF INSTALLED DG SETS OF VARIOUS CAPACITIES INCLUDING DIESEL ENGINE, ALTERNATOR, CONTROL PANEL AND COOLING AND EXHAUST SYSTEM, FUEL SYSTEM, LUBRRICATING SYSTEM, BATTERY CHARGER AND MAIN ASSEMBLY FRAME ETC AT EXPLOSIVE AND NON EXPLOSIVE AREAS INSIDE NAD AT NAVAL STATION KARANJA
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE KARANJA NAME OF WORK: COMPREHENSIVE MAINT OF B/R AND E/M WORKS LIKE REPAIR OF GENERATOR ROOM, SHED, FOUNDATION, APPROACH PATH, HARD STANDING AND SECURITY FENCING, ROUTINE AND PERIODIC REPAIR AND MAINTENANCE OF INSTALLED DG SETS OF VARIOUS CAPACITIES INCLUDING DIESEL ENGINE, ALTERNATOR, CONTROL PANEL AND COOLING AND EXHAUST SYSTEM, FUEL SYSTEM, LUBRRICATING SYSTEM, BATTERY CHARGER AND MAIN ASSEMBLY FRAME ETC AT EXPLOSIVE AND NON EXPLOSIVE AREAS INSIDE NAD AT NAVAL STATION KARANJA CONTRACT AGREEMENT: CWE KJ(K)- OF 2026 - 2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words)
2Maintenance and servicing to DG set including cleaning of DG set canopy,radiator and other parts with alkaline based chemical (water based) including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing/oiling of bearings of engine , alternator and other moving parts checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 625 KVA DG set installed complete all as specified and directed. Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iv) Work shall be carried out at site at different location
3TECHO CABLE
4PRIMING PUMP
5O RING
6SUPER BYPASS FILTER WITH O RING
7RADIATOR HOSE SET
8CLAMP SET
9AIR CLEANER HUMP HOSE
10AIR CLEANER HUMP HOSE CLAMP
11TURBO HUMP HOSE
12TURBO HUMP HOSE CLAMP
13VENT HOSE PIPE
14Lub oil filter
15FUEL PRE FILTER
16FUEL MICRO FILTER
17AIR FILTER PRIME
18AIR FILTER SECOND
19OIL TEMP. GAUGE
20WATER TEMP. GAGUE
21OIL PRESSURE GAUGE
22Fan Belt
23Uniball Joint
24Thermostate
25Hose diesel ( 7 Ft. )
26Oil filter head gasket
27RPM meter
28Maintenance and servicing to DG set including cleaning of DG set canopy,radiator and other parts with alkaline based chemical (water based) including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing/oiling of bearings of engine , alternator and other moving parts checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 500 KVA DG set installed complete all as specified and directed. Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iv) Work shall be carried out at site at different location
29TECHO CABLE
30PRIMING PUMP
31O RING
32SUPER BYPASS FILTER WITH O RING
33RADIATOR HOSE SET
34CLAMP SET
35AIR CLEANER HUMP HOSE
36AIR CLEANER HUMP HOSE CLAMP
37TURBO HUMP HOSE
38TURBO HUMP HOSE CLAMP
39VENT HOSE PIPE
40Lub oil filter
41FUEL PRE FILTER
42FUEL MICRO FILTER
43AIR FILTER PRIME
44AIR FILTER SECOND
45OIL TEMP. GAUGE
46WATER TEMP. GAGUE
47OIL PRESSURE GAUGE
48Fan Belt
49Uniball Joint
50Thermostate
51Hose diesel ( 7 Ft. )
52Oil filter head gasket
53RPM meter
54Maintenance and servicing to DG set including cleaning of DG set canopy,radiator and other parts with alkaline based chemical (water based) including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing/oiling of bearings of engine , alternator and other moving parts checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 400 KVA DG set installed complete all as specified and directed. Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iv) Work shall be carried out at site at different location
55TECHO CABLE
56PRIMING PUMP
57O RING
58SUPER BYPASS FILTER WITH O RING
59RADIATOR HOSE SET
60CLAMP SET
61AIR CLEANER HUMP HOSE
62AIR CLEANER HUMP HOSE CLAMP
63TURBO HUMP HOSE
64TURBO HUMP HOSE CLAMP
65VENT HOSE PIPE
66Lub oil filter
67FUEL PRE FILTER
68FUEL MICRO FILTER
69AIR FILTER PRIME
70AIR FILTER SECOND
71OIL TEMP. GAUGE
72WATER TEMP. GAGUE
73OIL PRESSURE GAUGE
74Fan Belt
75Uniball Joint
76Thermostate
77Hose diesel ( 7 Ft. )
78Oil filter head gasket
79RPM meter
80Maintenance and servicing to DG set including cleaning of DG set canopy,radiator and other parts with alkaline based chemical (water based) including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing/oiling of bearings of engine , alternator and other moving parts checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 250 KVA DG set installed complete all as specified and directed. Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iv) Work shall be carried out at site at different location
81TECHO CABLE
82PRIMING PUMP
83O RING
84SUPER BYPASS FILTER WITH O RING
85RADIATOR HOSE SET
86CLAMP SET
87AIR CLEANER HUMP HOSE
88AIR CLEANER HUMP HOSE CLAMP
89TURBO HUMP HOSE
90TURBO HUMP HOSE CLAMP
91VENT HOSE PIPE
92Lub oil filter
93FUEL PRE FILTER
94FUEL MICRO FILTER
95AIR FILTER PRIME
96AIR FILTER SECOND
97OIL TEMP. GAUGE
98WATER TEMP. GAGUE
99OIL PRESSURE GAUGE
100Fan Belt
101Uniball Joint
102Thermostate
103Hose diesel ( 7 Ft. )
104Oil filter head gasket
105RPM meter
106Maintenance and servicing to DG set including cleaning of DG set canopy,radiator and other parts with alkaline based chemical (water based) including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing/oiling of bearings of engine , alternator and other moving parts checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 180/200 KVA DG set installed complete all as specified and directed. Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iv) Work shall be carried out at site at different location
107TECHO CABLE
108PRIMING PUMP
109O RING
110SUPER BYPASS FILTER WITH O RING
111RADIATOR HOSE SET
112CLAMP SET
113AIR CLEANER HUMP HOSE
114AIR CLEANER HUMP HOSE CLAMP
115TURBO HUMP HOSE
116TURBO HUMP HOSE CLAMP
117VENT HOSE PIPE
118Lub oil filter
119FUEL PRE FILTER
120FUEL MICRO FILTER
121AIR FILTER PRIME
122AIR FILTER SECOND
123OIL TEMP. GAUGE
124WATER TEMP. GAGUE
125OIL PRESSURE GAUGE
126Fan Belt
127Uniball Joint
128Thermostate
129Hose diesel ( 7 Ft. )
130Oil filter head gasket
131RPM meter
132Maintenance and servicing to DG set including cleaning of DG set canopy,radiator and other parts with alkaline based chemical (water based) including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing/oiling of bearings of engine , alternator and other moving parts checking of batteries, applying petroleum jelly to battery terminals, adding distilled water checking the oil, coolent levels of capacity 100/62.5 KVA DG set installed complete all as specified and directed. Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per manufacturer’s specifications/ instructions (iv) Work shall be carried out at site at different location
133TECHO CABLE
134PRIMING PUMP
135O RING
136SUPER BYPASS FILTER WITH O RING
137RADIATOR HOSE SET
138CLAMP SET
139AIR CLEANER HUMP HOSE
140AIR CLEANER HUMP HOSE CLAMP
141TURBO HUMP HOSE
142TURBO HUMP HOSE CLAMP
143VENT HOSE PIPE
144Lub oil filter
145FUEL PRE FILTER
146FUEL MICRO FILTER
147AIR FILTER PRIME
148AIR FILTER SECOND
149OIL TEMP. GAUGE
150WATER TEMP. GAGUE
151OIL PRESSURE GAUGE
152Fan Belt
153Uniball Joint
154Thermostate
155Hose diesel ( 7 Ft. )
156Oil filter head gasket
157RPM meter
158Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
159(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 400 Amps – 01 No.(ii) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 320 Amps – 01 No.(iii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.(iv) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 01 No.(v) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 01 No.(iv) Multi function meter having LCD Display, 96 x 96 sq.mm - 01 No(v) Current transformer of suitable ratio, Accuracy - 5VA, Class 1 (vi) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each(vii) Aluminium bus bar of Rating 1000 Amp R-Y-B phases and Neutral.(viii) Base frame for cubical mounting made out of 40mm x 40mm x 6mm equal angle iron duly painted.(ix) Foundation for the panel should provided with PCC 1:4:8 using 40mm graded stone aggreagrs at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
160Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made, LT cubical, double door panel with roof canopy, outdoor type suitable to accomodate the following accessories made out of CRCA sheet 3mm thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle, Inner cubicle should be made out of 2mm thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase, 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp, shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
161(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.(B) OUTGOING-(i) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 100 Amps – 02 Nos.(ii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 63 Amps – 06 Nos.(iii) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(iv) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (v) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (vi) Aluminium bus bar of Rating 400 Amp R-Y-B phases and Neutral.(vii) Base frame for cubical mounting made out of 40mm x 40mm x 6mm equal angle iron duly painted.(viii) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. (viii) Foundation for the panel should provided with PCC 1:4:8 using 40 mm graded stone aggregates at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
162Supply,laying, jointing, connecting & testing LT XLPE insulated PVC sheathed armoured cable, heavy duty, 1100 volts grade, aluminum conductor as in trenches / ducts of following sizes including taking out existing cable of any make and specification including cable covers complete all as specified & directed:-
1633.5 core 240 Sqmm
1643.5 core 300 Sqmm
1653.5 core 400 Sqmm
1663.5 core 150 Sqmm
1673.5 core 120 Sqmm
1683.5 core 95 Sqmm
169M&L for earthing with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32mm x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) type B1 using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point including testing on completion and taking down old u/s materials complete all as specified and directed. NOTE: (i) The earth chamber shall be constructed 0.50m away from the edge of earth pit and the cost of the same is deemed to be included in quoted unit rate. (ii) GI Strip and protection pipe upto 7.5m is deemed to be included in the quoted unit rate. (iii) GI watering pipe upto 1.2m s deemed to be included in the quoted unit rate.
170Supply & fixing in repairs of fully automatic battery charger input 230V AC SMPS based) and out put 24V DC for 24 volt battery complete all as specified and directed.
171Supply & fixing in repairs of fully automatic battery charger input 230V AC SMPS based) and out put 12V DC for 12 volt battery complete all as specified and directed.
172Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 630 Amp 4pole 415 volts with sheet steel enclosure of made by 3.0mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed.
173Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 400 Amp 4pole 415 volts with sheet steel enclosure of made by 3.0mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed.
174Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 315 Amp 4pole 415 volts with sheet steel enclosure of made by 3.0mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed.
175Supply and Install , testing and commissioning the Onload change over switch front handle type of capacity 200/250 Amp 4pole 415 volts with sheet steel enclosure of made by 3.0mm thick CRCA sheet outdoot type along with pedestal to grout in PCC 1:3:6 type C2 of any thickness foundation and Indication lamps of R, Y, B for three phase supply indication and all as spcified and directed.
176Supply, in renewal of fabricating and testing of factory made/fabricated cubical type bypass panel double door outdoor type with degree of protection IP-65 conforming to IS-2147, suitable for 200 KVA to 315 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated aluminium bus bar to interconnect the Change over No-01 to No-02 ,Onload Change over switch of capacity suitable to meet the DG set rated output 4pole 415 volts -02 Nos, R ,Y, B LED Indicating lamps provn of connecting incoming and outgoing cables with preper cable glands of adequate size and the angle iron frame of suitable size to mount the panel at height of 45cm from ground level with PCC platform casted in PCC1:3:6 type C-1 (20mm aggregate) of adequate thickness all as specified and directed.Note : 1. Rate quoted shall include cost of camplete fabrication as described or as directed.2. Tech Drg and design shall be approved by GE before placing order by the contractor.
177Supply, in renewal of fabricating and testing of factory made/fabricated cubical type bypass panel outdoor type with degree of protection IP-65 conforming to IS-2147, suitable for 400 KVA to 500 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated aluminium bus bar to interconnect the Change over No-01 to No-02 ,Onload Change over switch as per rated capacity of DG Set 4pole 415 volts -02 No R ,Y, B LED Indicating lamps provn of connecting incoming and outgoing cables with cable glands of adequate size and the angle iron frame of suitable size to mount the panel at height of 45cm from ground level with PCC platform casted in 1:3:6 type C1 (20mm aggregate) of adequate thickness all as specified and directed. Note : 1. Rate quoted shall include cost of camplete fabrication as described or as directed.2. Tech Drg and design shall be approved by GE before placing order by the contractor.
178Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in Hard/dense soil including taking out faulty cable/cable covers and GI pipe complete all as specified and directed.
179Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
180Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point.
181M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers all as specified
182Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed.
183M&L for Cutting of Bituminious road / hard standing / PCC path / wall, including excavation in soft/loose soil, 25cm in width & 25cm in depth, and filled with Plain cement concrete 1:2:4 type B-1 (using 20mm graded coarse aggregate) in complete all as speified and directed.
184M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 80 mm bore of pipe all complete as specified and directed.
185M & L for providing services through qualified technician for troubleshooting generators/rectification of faultsor preventive inspection/checks to keep genrator health in optimum condition for 15 kva to 625 kva dg sets Note: (i) Quoted rate is inclusive of labour charges for technician visit, transport etc including T&P and minor spare parts like nuts bolts, washers, cleaning cloth,grease etc.
186Material and labour for disconnecting all electrical connections from DG set alternator of any capacity from base plate by opening nuts & bolts keeping aside the alternator for inspection and taking out to work shop for rewinding including testing and commissioning complete all as specified and as directed.
187M & L for rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing for capacity 15 KVA DG set to 30 KVA DG set.
188M & L for rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing for capacity 62.5 KVA DG set to 100 KVA DG set.
189M & L for rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing for capacity 125 KVA DG set to 160 KVA DG set.
190M & L for rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing for capacity 180 KVA DG set to 250 KVA DG set.
191M & L for rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing for capacity 300 KVA DG set to 400 KVA DG set.
192M & L for rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing for capacity 500 KVA DG set to 750 KVA DG set.
193Material and labour for water temperature guage including sensor and cable complete as per sample including removal of existing unserviceable one complete all as specified and as directed.
194Material and labour for dismantaling the radiator and taking to work shop for overhauling & cleaning, de-scaling with alkaline based chemical , removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for capacity of 15 KVA to 30 KVA DG set complete all as specified and as directed
195Material and labour for dismantaling the radiator and taking to work shop for overhauling & cleaning, de-scaling with alkaline based chemical , removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for capacity of 62.5 KVA to 100 KVA DG set complete all as specified and as directed
196Material and labour for dismantaling the radiator and taking to work shop for overhauling & cleaning, de-scaling with alkaline based chemical , removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for capacity of 125 KVA to 160 KVA DG set complete all as specified and as directed
197Material and labour for dismantaling the radiator and taking to work shop for overhauling & cleaning, de-scaling with alkaline based chemical , removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for capacity of 180 KVA to 200 KVA DG set complete all as specified and as directed
198Material and labour for dismantaling the radiator and taking to work shop for overhauling & cleaning, de-scaling with alkaline based chemical , removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for capacity of 250 KVA to 300 KVA DG set complete all as specified and as directed
199Material and labour for dismantaling the radiator and taking to work shop for overhauling & cleaning, de-scaling with alkaline based chemical , removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for capacity of 400 KVA to 500 KVA DG set complete all as specified and as directed
200Material and labour for dismantaling the radiator and taking to work shop for overhauling & cleaning, de-scaling with alkaline based chemical , removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads,hoses,clips, etc and refixing its original position for capacity of 600 KVA to 750 KVA DG set complete all as specified and as directed
201Material and labour for repair and calibration of FIP and injectors from repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for capacity 15 KVA to 30 KVA DG set complete all as specified and as directed.
202Material and labour for repair and calibration of FIP and injectors from repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for capacity 62.5 KVA to 100 KVA DG set complete all as specified and as directed.
203Material and labour for repair and calibration of FIP and injectors from repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for capacity 125 KVA to 160 KVA DG set complete all as specified and as directed.
204Material and labour for repair and calibration of FIP and injectors from repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for capacity 180 KVA to 200 KVA DG set complete all as specified and as directed.
205Material and labour for repair and calibration of FIP and injectors from repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for capacity 250 KVA to 400 KVA DG set complete all as specified and as directed.
206Material and labour for repair and calibration of FIP and injectors from repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for capacity 500 KVA to 750 KVA DG set complete all as specified and as directed.
207M & L for reset and reprogramming/updated of existing software in control panel of DG set upto 125 KVA as completed all as specified and directed.
208M & L for reset and reprogramming/updated of existing software in control panel of DG set upto 150 to 250 KVA as completed all as specified and directed.
209M & L for reset and reprogramming/updated of existing software in control panel of DG set upto 315 to 625 KVA as completed all as specified and directed.
210Supply and fix in repairs battery charging circuit suitable for 12 volts, DC in existing DG set panel board including addition/ alteration in wiring system complete with auto transformer, diodes, filter circiut, condensers, DC ammeter, DC volt meter with selector switches and indicating bulbs etc complete all as specified and as directed.
211Supply and fix in repairs for battery charging circuit suitable for 24 volts, DC in existing DG set panel board including addition/ alteration in wiring system complete with auto transformer, diodes, filter circiut, condensers, DC ammeter, DC volt meter with selector switches and indicating bulbs etc complete all as specified and as directed.
212Material and labour for repair/ overhauling of self starting system of DG set including replacement of carbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 24 volts with necessary connections incluing testing and commissioing complete all as specified and as directed.
213Material and labour for repair/ overhauling of self starting system of DG set including replacement of carbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 12 volts with necessary connections incluing testing and commissioing complete all as specified and as directed.
214Supply and fix microprocessor based multifunction controller with necessary accessories complete suitable for DG sets operation of any capacity and showing the various parameters such as volt, ampere, frequency, RPM etc complete as per manufacturer of DG set with site requirment including removal of existing unserviceable one complete all specified and as directed.
215Material and labour for SMPS (system main power supply) type control unit assembly suitable for 24 volts battery charger for including removal of existing unserviceable one compete all as specified and as directed .
216Supply and fix for battery low maintenance lead acid of capacity 12 volts 180 AH with initial charging including removal of existing unserviceable one and hand over to store yard compete all as specified and as directed.
217Supply and fix for battery low maintenance lead acid of capacity 12 volts 150 AH with initial charging including removal of existing unserviceable one and hand over to store yard compete all as specified and as directed.
218Supply and fix for battery low maintenance lead acid of capacity 12 volts 135 AH with initial charging including removal of exsting unserviceable one and hand over to store yard compete all as specified and as directed.
219Supply and fix for battery low maintenance lead acid of capacity 12 volts 100 AH with initial charging including removal of extg unserviceable one and hand over to store yard compete all as specified and as directed by Engr-in charge.
220Material and labour for carrying out repairs to AMF panel of 15 KVA to 200 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measured and paid seperately under relevant items.
221Material and labour for carrying out repairs to AMF panel of 250 KVA to 625 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measured and paid seperately under relevant items.
222Supply only for digital type frequency meter 96 x 96 mm flush/ square pattern compete all as specified. Make: L&T/ AE or equivalent.
223Supply only for digital type Ammeter 0-400 /5 Amps 96 x 96 mm square flush pattern with selector switch compete all as specified and as directed by Engr-in charge.
224Supply only for digital type Ammeter 0-200 /5 Amps 96 x 96 mm square flush pattern with selector switch compete all as specified.
225Supply only for digital type Ammeter 0-100 /5 Amps 96 x 96 mm square flush pattern with selector switch compete all as specified.
226Supply only for digital type Voltmeter 0-500 Volts 96 x 96 mm square flush pattern with selector switch compete all as specified.
227Supply only for LED indicator lamps R, Y, B with holder 15 mm screw type compete all as specified.
228Supply only for CT cast resin type of ratio 400/5 Amps of suitable VA burden compete all as specified.
229Supply only for CT cast resin type of ratio 200/5 Amps of suitable VA burden compete all as specified.
230Supply and fix for CT cast resin type of ratio 100/5 Amps of suitable VA burden including removal of existing unserviceable one compete all as specified and as directed.
231Supply and fix 3 phase voltage monitoring relay DIN rail of suitable VA burden including removal of existing unserviceable one compete all as specified and as directed.
232Supply & filling of Engine oil, multi grade premium Genuine oil 15W/ 40 as per manufacturer recommendations in DG sets complete all as specified.
233Supply and applying for petrolium Jelly (01 Kg plastic sealed container) complete all as specified and as directed.
234Supply and fill for distilled water for topping up in lead acid batteries and radiator complete all as specified and as directed.
235Supply and fill for electrolyte of suitable specific gravity for lead acid batteries in sealed container complete all as specified and as directed.
236Supply and fill for genuine coolant in 5 litres plastic sealed container for topping up in Radiator of DG set located at different locations complete all as specified and as directed.
237Material and labour for battery leads of PVC insulated, multistranded, copper conductor of size 50 Sqmm of 1.25 metres long each duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations including removal of existing unserviceable one complete all as specified and as directed.
238Material and labour for battery teriminal brass clamps including removal of existing unserviceable one compete all as specified and as directed.
239Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 63 -100 Amps with thermal magnetic release breaking capacity 16 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
240Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 125 Amps with thermal magnetic release breaking capacity 16 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
241Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 160 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
242Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 200 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
243Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 250 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
244Supply, connecting and testing for MCCB in existing DG set panel of capacity 3 pole 400 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu , suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON position, connecting and testing complete including removal of existing unserviceable complete all as specified and as directed.
245Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debries directed for a distance max upto 500m complete all as specified.
246Material and Labour using ready mix plaster for rendering 15 mm thick on fair faces of brick/concrete surfaces cement plaster in CM (1:4) , finished even and smooth without using extra cement, complete all as specfified and directed.
247Material and Labour using ready mix plaster rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6 finished even and smooth (with out using extra cement) complete all as specified.
248Material and Labour rendering 5mm thick in CM 1:3 on ceiling finished even and smooth incl sagol finish complete all as specified and directed.
249Material and Labour for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer complete all as specified and as directed
250Material and Labour for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces complete all as specified and directed.
251Material and Labour preparation of new plastered surface of ceiling and applying three coat of white wash on ceiling complete all as specified and directed.
252Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
253Material and Labour roof trusses (framed) trussed, purlins, crane gantaries, rails and fastening and heavy braket framing (beam, tee, angle, chanel or flat section) including distance peices etc conforming to Fe 410 W Gde E-250 complete all as specified and directed.
254Supply and fix Steel work in tubular trusses, pillars and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 all as specified and directed by Engr-in-Charge.
255Framed work such as grills, gratings, sun shed etc with ends of bars shouldered and/or riveted or welded, or forged into spikes, framed guard bars, fencing angle incl cutting top to shape as direced, barred iron doors, ladders, farmed balastures, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290-0 or E-165 complete all as specified and directed.Note:-Posts/struts of angle iron made to shape shall be welded to existing angle iron bracket of security wall, contractor shall make his own arrangement for welding for boundary wall by using gen sets or any alternative arrangement all as specified and directed by Engr-in-Charge.
256Supply and fix mild steel security chain link fencing 50 mm x 50 mm with PVC coated mesh made out of 3mm dia MS wire and 1.00mm thick PVC coating throughout fixed to RCC post including binding wire complete and incl taking down of existing chain link fencing all as specfied and directed.
257Supply and fix mild steel screw bolts 10mm dia with hexagonal or square heads at one end and screwed at other ends dia of shank 5 to 10 mm and length of bolt exc. 5cm but n.exc 10cm complete all as specified and directed.
258Supply and fix mild steel round bars 10mm dia and over, in horizontal support for chain link straining of fencing including cut to length, bent to shape required including cranking, bending spirally for hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) complete all as specified and directed.
259Material and Labour for Preparation of new steel surface of any description not otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed by Engineer-in-Charge.
260Material and Labour for Preparation of old painted steel surface of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
261Dismantling AC (Corrugated, semi corrugated, etc) sheets in roof coverings complete all as specified and as directed
262Dismantling plain or corrugated steel sheeting ,any gauge ,thickness incl Nainital or similar pattern roof covering
263Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and as directed
264Supply and fix pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and as directed
265Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above ground level un re-inforced complete all as specified and directed. .
266Material and Labour PCC 1:4:8 type D2, using (40 mm graded agg) ,75 mm thick as in sub base of flooring all as specified & directed
267Material and Labour PCC 1:2:4 type B1, using (40 mm graded agg) ,25 mm thick as in sub base of flooring all as specified & directed
268Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar complete all as specified and directed.
269Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
270Material and Labour for Chequered cement concrete tiles 30cm x 30cm x 25mm thick set jointed and pointed in neat cement slurry in floors with in equal proportions & pigments with red and yellow colour over including 20mm thick screed bed in CM 1:6 complete all as specified and directed
271Supply and fin in mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes Fe 410-W (Gde-E 250) quality-A fixed complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56446415
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 92 Lakhs
LAST DATE 11-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Maintenance Of B/R And E/M Works Like Repair Of Generator Room, Shed, Foundation, Approach Path, Hard Standing And Security Fencing, Routine And Periodic Repair And Maintenance Of Installed Dg Sets Of Various Capacities Including Diesel Engine, Alternator, Control Panel And Cooling And Exhaust System, Fuel System, Lubrricating System, Battery Charger And Main Assembly Frame Etc At Explosive And Non Explosive Areas Inside Nad At Naval Station Karanja
Basic Detail
Tender No 84560-K/E8
Bidding Type Tender
Location
City Raigad
State Maharashtra
Key Dates
Publish Date 13 Jul 2026
Submission Date 11 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 92 Lakhs
Tender Fee 1000
EMD 1.63 Lakhs
Exemption Not Available
Document List
027a031e-96d5-4594-ba1f-7dda9da82b68.html
BOQ_871461.xls
SOC.pdf
tenderd.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
html

027a031e-96d5-4594-ba1f-7dda9da82b68.html

xls

BOQ_871461.xls

pdf

SOC.pdf

pdf

tenderd.pdf

pdf

Tendernotice_1 (6).pdf