Tender For Conversion Of Certain Cat B Danger Buildingto Cat A Danger Building With Allied Works Services At Af Station Naliya Dated : 13 Jul 2026
Tender Overview
Project Description
Tender for Conversion Of Certain Cat B Danger Buildingto Cat A Danger Building With Allied Works Services At Af Station Naliya Dated : 13 Jul 2026
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Jul-2026 | Revised Drg | Other | 17-Aug-2026 |
| 2 | 17-Jul-2026 | amendment in tender document | Other | 17-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Schedule ‘A’ Part I to XIII under Ser No. 1.00 to 13.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part-I |
| 3 | Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part-II |
| 4 | Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A' Part-III |
| 5 | Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part-IV |
| 6 | Lump sum price worked out for ROAD/ PATH as listed in Sch 'A' Part-V |
| 7 | Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch 'A' Part-VI |
| 8 | Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part-VII |
| 9 | Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A' Part-VIII |
| 10 | Lump sum price worked out for AIR CONDITIONING as listed in Sch 'A' Part-IX |
| 11 | Lump sum price worked out for ELECTROSTATIC DISCHARGE SYSTEM as listed in Sch 'A' Part-X |
| 12 | Lump sum price worked out for DG SET as listed in Sch 'A' Part-XI |
| 13 | Lump sum price worked out for PLINTH FOR PVC WATER TANK as listed in Sch 'A' Part-XII |
| 14 | Lump sum price worked out for ALUMINIUM DOOR/ PARTITION FOR NON-AC BUILDING as listed in Sch 'A' Part-XIII |
| 15 | SCHEDULE 'A' PART - XIV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicated blank under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. |
| 16 | INTERNAL WATER SUPPLY |
| 17 | Supply and fix 15 mm dia two way angle cock, cast copper alloy (ISI marked) fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union, complete all as specified and as directed. |
| 18 | INTERNAL ELECTRIFICATION |
| 19 | Supply and fix wall mounted LED box type tube light fitting 4 feet x 20 Watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen output box type fitting, 230 volts and intregrated electronic driver connector block etc. with warranty option of 5 years from date of installation complete with all accessories internally prewired and necessary mounting arrangments and provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 20 | Supply and fix LED tube light fitting with aluminium housing 2 feet x 10 Watts, mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting with warranty option of five years from date of installation complete all as specified and as directed. |
| 21 | Supply and fix highly efficient LED bulbs, 10 Watt having B-22 cap complete all as specified and as directed. |
| 22 | Supply and fix energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire of capacity 25 Watts with high power LEDs as light source and suitable electronic driver with pre wired and necessary mounting arrangements and provision of 2.5 sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed |
| 23 | Supply and fix energy efficient exhaust fan of 225 mm sweep made of metal body complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed.Note: Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted. |
| 24 | SEWAGE DISPOSAL |
| 25 | Material and labour for on site LLDPE septic tank for 25 users, designed to carry sewage and sullage water including excavation in any type of soil, PCC 1:4:8 foundation, vent shaft, connection etc. complete all as specified and and directed. |
| 26 | Material and labour for construction of soakage wells of 1.8 metre dia and 4.5 metre effective depth, including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including interception chamber and screen chamber made of brick masonry in CM 1:4, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/ DWC complete filled with brick bats all as shown on drawing No. CEAA/TD/80, sheet 1/2 and sheet 2/2 and as specified and directed. |
| 27 | EXTERNAL WATER SUPPLY |
| 28 | Dismantling the existing RO plant including disconnection of all existing pipe connections, water tank of 5000 ltr (qty=3 nos.) and installing in new location after servicing of RO plant and repair if any unservicability found, including testing and commissioning complete all as specified and directed. |
| 29 | Material and labour for construction of brick masonry valve pit of internal size 600mm x 600mm x 700mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 5 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4)(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:3:6) type C2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation |
| 30 | Material and labour for construction of brick masonry valve pit of internal size 450mm x 450mm x 600mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 5 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:3:6) type C2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation |
| 31 | EXTERNAL ELECTRIFICATION |
| 32 | Supply and lay double wall corrugated (DWC) high density polyethylene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 14930 (Part I and II) for protection of underground cables of size nominal outer dia 63 mm and nominal inner dia 50 mm with all fittings laid in trenches/ road/ nallah or fixed along wall for cable protection complete all as specified and as directed. |
| 33 | Supply and lay double wall corrugated (DWC) high density polyethylene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 14930 (Part I and II) for protection of underground cables of size nominal outer dia 90 mm and nominal inner dia 76 mm with all fittings laid in trenches/ road/ nallah or fixed along wall for cable protection complete all as specified and as directed. |
| 34 | Supply and lay double wall corrugated (DWC) high density polyethylene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 14930 (Part I and II) for protection of underground cables of size nominal outer dia 120 mm and nominal inner dia 103.50 mm with all fittings laid in trenches/ road/ nallah or fixed along wall for cable protection complete all as specified and as directed. |
| 35 | Supply and lay double wall corrugated (DWC) high density polyethylene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 14930 (Part I and II) for protection of underground cables of size nominal outer dia 160 mm and nominal inner dia 136 mm with all fittings laid in trenches/ road/ nallah or fixed along wall for cable protection complete all as specified and as directed. |
| 36 | Supply and fix cable route indicator/ marker made up of PCC block in cement mortar 1:3:6 (using 20 mm graded stone aggregrate) of size 900 x 300 x 100 mm thick with \\"DANGER/ 11 KV CABLE/ MES\\" embossing on cable route Indicator/ marker including painting as per approved colour and buried in ground 45 cm including necessary earth work (as required/ ordered at site) complete all as specified and as directed. |
| 37 | Supply and fix cable route indicator/ marker made up of PCC block in cement mortar 1:3:6 (using 20 mm graded stone aggregrate) of size 900 x 300 x 100 mm thick with \\"DANGER/ LT 433 VOLTS CABLE/ MES or DANGER/ MES\\" embossing on cable route Indicator/ marker including painting as per approved colour and buried in ground 45 cm including necessary earth work (as required/ ordered at site) complete all as specified and as directed. |
| 38 | Supply, installation, testing and commissioning of indoor type (IP 3X), 04 way RMU (Ring Main Unit), 11 KV, 630 Amps, 25kA-3 Sec, IP 3X SF6 insulated, one side extensible, consisting of Two Nos (02) motorised vacuum circuit breaker (Incomer) and Two Nos (02) motorised vacuum circuit breaker (Outgoing) and Metering Panel Bus PT with Top LV, Battery and Battery charger, Ethernet switch and LIU (Configuration VVVV+M), inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-1. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions complete with all accessories. The complete RMU must be type tested for internal arc 25 KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must be RMU manufacturer's own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fittings complete all as specified and as required at site:- |
| 39 | Notes:- (a) Vacuum Circuit Breaker shall consist of the following accessories:-(i) Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95, Measurement for 3I, I0, 3U, U0, Kw, KVA, PF, Hz, Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display.(ii) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder. (iii) SF6 Gas pressure indicator on the gas tank(iv) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation(v) CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi) CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering |
| 40 | (vii) Right angle boot to be provided in each module(viii) 2 x12 Volts, 26 AH Battery with Charger - 1 Set(ix) Bus VT shall be 11KV/V3/110V/V3, 20VA , Class 0.5 - 3 Nos. for metering(x) Auxiliary VT shall be 11KV/230, 500VA for AC supply input to Battery Charger(xi) Capacitive voltage indication fixed type system as per IE(xii) Interlocked cable box for front termination of the cable suitable upto 3 core 120 Sqmm, 11 KV XLPE cable (IP3X) safety interlocked to prevent access to cable termination in live-condition(xiii) Right angle boots (push on type)(xiv) Cable covers with self interlocking mechanism between doors, earth switch, disconnector and VCB(xv) Necessay interclocking arrangement for safety and operations(xvi) One no. operating handle for manual operation and one no. manometer(xvii) Safety interlocks shall be provided as per relevant IEC/ IS standards and manufacturer's directions(xviii) Above switchgear shall confirm to all relevant IEC/ IS standards |
| 41 | Supply, installation, testing and commisioning of Compact Sub Station (CSS) stainless steel enclosure with series trip, self-powered microprocessor based numerical over current and earth fault relay protection. Interconnection between HT switchgear and primary of transformer shall be done through HT 11 KV, 1 core x 3 runs of 95 sqmm with aluminium unarmored XLPE cable complete with following accesories all as specified and directed:-(a) Vacuum Circuit Breaker- Indoor type (IP 3X),11 KV, 630 Amps, 25kA-3 Sec, IP 3X SF6 insulated motorised vacuum circuit breaker and Metering Panel Bus PT with Top LV, Battery and Battery charger, Ethernet switch & LIU inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges and Air Insulated Metering Module of Class-0.5, the complete VCB must be type tested for internal arc 25KA for 1 sec with AFLR classification for gas tank and cable chamber as per IEC 62271-200. HT VCB shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the VCB to OEM Works including padlock provisions and complete with all accessories.(i) Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95, Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh,16DI + 10DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display.(ii) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii) SF6 Gas pressure indicator on the gas tank. |
| 42 | (iv) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation.(v) CT shall be minimum 50-100/1A, 2.5VA, 5P10 - 3 Nos. for protection(vi) CT shall be minimum 50-100/1A, 2.5VA, Class 0.5 - 3 Nos. for metering(vii) Right angle boot to be provided in each module(viii) 2 x12 Volts, 26 AH Battery with Charger - 1 Set(ix) Bus VT shall be 11KV/V3/110V/V3,20VA , Class 0.5 - 3 Nos. for metering(x) Auxiliary VT shall be 11KV/230,500VA for AC supply input to Battery Charger.(xi) Capacitive voltage indication fixed type system as per IE(xii) Interlocked Cable box for front termination of the cable suitable upto 3 core 95 Sqmm, 11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. (xiii) Right angle boots (push on type)(xiv) Cable covers with self Interlocking mechanism between doors, earth switch, disconnector and VCB.(xv) Necessay interclocking arrangement for safety and operations(xvi) One No. Operating Handle for Manual Operation and one no. manometer(xvii) Safety Interlocks shall be provided as per relevant IEC/IS Standards and Manufacturer's directions.(xviii) Above switchgear shall confirm to all relevant IEC/IS Standards.(xix) Incoming Cable shall be required Touch proof Termination kit |
| 43 | (B) 11 KV/ 433 Volts Transformer:- Transformer of capacity 160 KVA, confirming to IS 1180 (Part-1) -2014 with latest amendment No. 4, BEE 3 star rated, EEL 3, step down outdoor type complete with standard fittings, HT 11 KV 3 phase LT 433 volts, 3 phase, 4 wire corrugated 7 position off circuit tape links of rating +10% to -10% @ 2.5% by means of hand operated off load tap changer including necessary control wiring transformer copper wound, double wound, oil immersed naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn -11 (vector group with neutral brought on secondary side (LV side) and the maximum temperature rises should not exceed 40 degree centigrade in oil and 45 degree centigrade in HV/LV winding ring measured by resistance after continuous full load run in ambient temp as per IS -2026 per transformer, IS-3639 for fitting and accessories, IS-2099 for high voltage porcelain bushings and the transformer shall be comprised with the following standard fitting with on load tappings on HT side to vary secondary voltage within limit all as per IS -1180: (i) Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers with cable end box.(ii) Four Nos porcelain bushing suitable for 433 Volts on LV side, complete with copper rods, nuts and washers with cable end box.(iii) Monogram plate.(iv) Oil conservator with filter and drain plug.(v) Prismatic/ transparent oil gauge.(vi) De-hydrating breather with first fill of dehydrating agent (silica gel). |
| 44 | (vii) Thermometer pocket.(viii) Air release plug.(ix) Inspection cover(x) Lifting lugs for complete transformer(xi) Top cover lifting lugs(xii) Jacking lugs(xiii) Top filter valve(xiv) Instruction plate(xv) Drain cum bottom filter valves(xvi) Earthing terminal and stud(xvii) Off load tap changer(xviii) Rating and Diagram plate(xix) Buchholz relay with alarm and trip contacts.(xx) First filling of new and unused transformer oil, IS-335(xxi) Marshalling box for termination of all alarm and trip controls of the transformer.(xxii) WTI (Winding temperature indicator) with alarm and trip contact(xxiii) Oil surge relay.(xxiv) Shut off valve for buchholz relay.(xxv) OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type. |
| 45 | (C) LV Supply Panel:- (i) Copper strip busbar of 300 Amps rated capacity wrapped with PVC sleeves with maintaining the colour code and provision of making holes with copper nuts, bolts and washers for cable connections including hydrograpic insulators with nuts and bolts at both ends = 04 Nos.(ii) MCCB 320 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No.(iii) Outdoor type enclosure having construction of Galvanized Sheet Steel of thickness 2mm for Load Bearing Member and 1.5mm for Non-Load Bearing members with HRCA base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP34 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Paint (Colour Light grey & D.A. grey), each compartment shall be provided with the door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided for MV & LV compartment and switch operated lamp in transformer compartment with bulkhead arrangement.(iv) Interconnection between Transformer & LT switchgear using Aluminum Busbars- 1 set(v) Internal earthing connections by using GI strip of size 32 x 6 mm thick for body and copper strip of size 25 x 4 mm thick for neutral of transformer. |
| 46 | Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultrasound technique and necessary machine including provision of HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for cable protection and making good as existing complete all as specified and as directed. |
| 47 | Supply, installation, testing and commissioning of servo controlled voltage stabilizer confirming to IS:9815 Part-I:1994, reaffirmed 2019, of capacity 160 KVA, 3 phase, 50 Hz, naturally oil cooled, indoor, unbalanced type, copper wound, digital display type, relay free smooth and silent operation with first filling of transformer oil (IS 335 :2018) with the specifications given in notes below complete all as specified and as directed.Notes:- Servo controlled voltage stabilizer shall have following specifications:(i) Input voltage 360 Volts - 480 Volts(ii) Output voltage 415V+/- 1% (Adjustable) (iii) Rated frequency 50 Hz (iv) No distortion in wave form (v) Response time not to exceed 10 milli seconds (vi) Sensitivity (+/-1) 1% (vii) Rate of correction more than 6 volt/second for per phase (viii) Class of insulation - A (ix) No load losses less than 0.5% (x) Full load losses less than 2.5%(xi) Duty cycle - continuous 24x7 (xii) Efficiency more than 95% (xiii) Type of load: 3 phase, unbalanced type(xiv) Digital display voltmeter/ammeter (xv) Over load/short circuit protection(xvi) High/ low voltage cut off (xvii) By pass arrangement in case of emergency |
| 48 | Supply, fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical, outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protection made out of 3.15 mm thick CRCA sheet of suitable size to accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side, with IP 65 protection and provision of suitable bus bar chamber and switch gear compartments for MCCB incoming and outgoing feeders etc. with copper extension links of suitable current carrying capacity not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provision for termination with incoming and outgoing cables with cable glands, LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminous paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1 (using 20 mm graded stone aggregate), all extension link/ inter connection shall be insulated with heat shrinkable colour coded sleeves complete all as specified and directed and including the following accessories:- |
| 49 | INCOMING:-(a) Copper strip busbar of 300 Amps rated capacity wrapped with PVC sleeves with maintaining the colour code and provision of making holes with copper nuts, bolts and washers for cable connections including hydrographic insulators with nuts and bolts at both ends - 04 Nos.(b) 4 Pole MCCB 320 Amps with rotary handle, adjustable thermal magnetic release type, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader link- 01 No.(c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/ 250 volts, AC- 01 set (set of three) (d) Digital ammeter of range (0- 1000) Amps, flush mounting type with suitable CTs of ratio and selector switch - 01 set(e) Digital voltmeter of range (0-500) Volts, flush mounting type with selector switch - 01 No. OUTGOING:-(a) MCCB 250 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (b) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (c) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos (d) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel- 01 No. Please Enable Macros to View BoQ information |
| 50 | INCOMING:-(a) Copper strip busbar of 300 Amps rated capacity wrapped with PVC sleeves with maintaining the colour code and provision of making holes with copper nuts, bolts and washers for cable connections including hydrographic insulators with nuts and bolts at both ends - 04 Nos.(b) 4 Pole MCCB 320 Amps with rotary handle, adjustable thermal magnetic release type, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity including all fixing accessories with both ends spreader link- 01 No.(c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/ 250 volts, AC- 01 set (set of three) (d) Digital ammeter of range (0- 1000) Amps, flush mounting type with suitable CTs of ratio and selector switch - 01 set(e) Digital voltmeter of range (0-500) Volts, flush mounting type with selector switch - 01 No. OUTGOING:-(a) MCCB 250 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (b) MCCB 100 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (c) MCCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 02 Nos (d) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/ shutter of LT Panel- 01 No. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 27 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 27 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender