Tender For Special Repairs To Gol Market Shops (Bldg No P-62 & 49) Of Ganeshkhind Area At Drdo Estate Under Ge (I) R&D Pashan, Pune
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Aug 2026
10 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Gol Market Shops (Bldg No P-62 & 49) Of Ganeshkhind Area At Drdo Estate Under Ge (I) R&D Pashan, Pune
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling, floor, hearth or wall tiling 10mm to 25mm thick including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, Complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for including disposal of material within 50 metre lead complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Providing and laying in position cement concrete 1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40mm nominal size Recycled Aggregate (RA) complete all as specified and directed. |
| 4 | Material and labour for cement concrete 1:2:4 in pavements, laid to required slope and chamber in panels as required including consolidation finishing and tamping complete all as specified and directed. |
| 5 | Providing and laying 40mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) with 20mm nominal size stone aggregate finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc complete all as specided and directed. |
| 6 | Material and labour for Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4, Light shade pigment using white cement complete all as specified and directed. |
| 7 | Providing and laying double charged Vitrified tiles of size 600mm x 600mm in floor (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 8 | Providing and laying double charged vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete all as specified and directed. |
| 9 | Providing and fixing 1st quality ceramic glazed wall tiles 300x450 conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete all as specified and directed |
| 10 | Providing and laying Ceramic Anti-skid floor tiles of size 400x400 (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622, of approved make in colours such as white, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigments etc and complete all as specified and directed. |
| 11 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 12 | Providing and laying Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing, moulding and polishing etc. complete all as specified and as directed by the Engineer-in-Charge. |
| 13 | Material and labour for kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete all as specified and directed. |
| 14 | Providing and laying plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth complete all as specified and directed. |
| 15 | Demolishing cement concrete (un-reinforced) in roof/floors other than ground level beam, stair case, landing, chajjas and similar items including water proofing treatment in any layers and removal of debris to distance exceeding 250meter and not exceeding 500meter from the site complete all as specified and directed. |
| 16 | Material and Labour for PCC 1:2:4 (Type B0 using 12.5 mm graded aggregate) levelling course average thick 50 mm, to match the undulations of roof crete surface in cement mortar 1:4 for receive the roof finishes with water proofing liquid (WPL shall be measured and paid separately)complete all as specified and directed. |
| 17 | Material and labour for rendering 10 mm thick on fair faces of concrete surface in cement mortar 1:3 for receive the roof finishes with water proofing liquid. (WPL Shall be measured and paid separately) complete all as specified and directed. |
| 18 | Material and labour for preparation of surface to make free from dust particles etc. applying one coat of water based primer @ 0.15kg/sqm polyurethane modified dispersion coating that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane of same materials after dilution of water at 50% or specific primer matching same material (single component, cold applied, non toxic, VOC complaint) and laying of 200 GSM non woven geo textile membrane fibre mesh over synthetic rubber adhesive. Followed by applying two coats of polyurethane coating with @ 1.50 kg/sqm in two coats to achieving dry film thickness of 1 to 1.50 mm thick having a elogation capacity of over 600% Complete all as specified and directed by Engineer-in-Charge.The material shall achieve following properties: (i) Elongation (ASTM D412) : 600 %, (ii) Specific gravity : 1.50 + 0.1 g/cc, (iii) Solid content : 85% min., (iv) Tensile strength (ASTM D412): 2.5 N/mm2, (v) Crack bridging (ASTM C836) > 2mm Tear resistance (ASTM D624) : 15 kN/m, (vi) Water vapour transmission(ASTM E96) : 0.6 g/m²/hr., (vii) Water permeability @ 5 bar : Nil, (viii) Shore A hardness (ASTM D2240) : 60, (ix) Adhesion in-peel test (ASTM C836) > 50N Note . The work shall be executed through auth applicator of manufecturer only. Contarctor has to provide manufecturer test certificates for the above mentioned technical parameters and PVs. The contractor has to submit the guarantee for 10 Years against the water proofing treatment. |
| 19 | Supply only liquid water proofing compoud as approved by GE complete all as specified and directed. |
| 20 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 21 | Material and labour for 12mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces of wall complete all as specified and directed |
| 22 | Material and labour for 5mm thick rendering in CM 1:4 on fair faces of concrete surfaces of ceiling complete all as specified and directed |
| 23 | Material and Labour for 18 mm thick cement plaster in two coats under layer 12 mm thick cement plaster 1:5 finished with a top layer 6 mm thick cement plaster 1:6 using water proofing compound (WPC shall be measured and paid separately) complete all as specified and directed. |
| 24 | Providing and applying plaster of paris putty of 1.0 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 25 | Material and labour for Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (two coats) over and including water thinnable priming coat with cement primer complete all as specified and directed. |
| 26 | Material and Labour for complete removal of existing treatment on wall and applying two coats distmper oil emulsion over a coat of alkali resistent primer complete all as specified and directed. |
| 27 | Material and labour for preparation of newly plastered wall surface and applying two coat Two coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance of over one coat of acrylic water based exterior grade primer @ 0.9litre(undiluted)/10 sq mtrs diluted with water in 1:1 ratio as per manufacture's instruction and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed. |
| 28 | Material and labour for white washing three coat with lime to give an even shade on ceiling for newly plastered surface complete all as specified and directed |
| 29 | Material and labour for white washing old work two coats with lime to give an even shade on celing complete all as specified and directed |
| 30 | Material and labour for preparing old surfaces and finishing walls with two coats of Acrylic smooth exterior paint of required shade as directed bny Engr-in-Chareg. (Two coat applied @ 1.67 ltr/10 Sqm) |
| 31 | Dismantling doors, windows and clerestory windows (steel or wood or pvc) shutter Of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead complete all as specified and directed. |
| 32 | Providing and fixing aluminium frame work for windows (three track), ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be Powder coated (minimum thickness of powder coating 50 micron) smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 33 | Providing and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) shutters of windows including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 34 | Supply and fix in repairs stainless steel wire gauge (grade 304) aperture 1.4mm and 0.50mm dia wire for fixing of window, ventilator etc complete all as specified and directed by Engr-in-charge |
| 35 | Providing and fixing glazing with float glass panes of 5 mm thickness (weight not less than 12.50 Kg/Sqm) in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of Engineer-in-charge (cost of aluminium snap beading shall be paid in basic item) |
| 36 | Material and labour for pressed steel door frames (mild steel sheet 1.60mm) profile 'B' of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed. |
| 37 | Material and labour for plain cement concrete Type C2, 1:3:6 (using 20mm graded aggregate) for filling of hollow pressed steel frame complete all as specified and directed. |
| 38 | Providing and fixing ISI marked flush door shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters complete all as specified and directed. |
| 39 | Providing and applying painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two coats on new / old wood work over an under coat of suitable shade with ordinary paint of approved brand and manufacture complete all as specified and directed. |
| 40 | Providing and applying painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two coats on new / old MS work over an under coat of suitable shade with ordinary paint of approved brand and manufacture complete all as specified and directed. |
| 41 | Supply and fix 100x75mm long butt hinges extruded aluminum alloy with galvanised mild steel hinge pin anodised type B-21 complete all as specified and directed. |
| 42 | Supply and Fix 300 mm long Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections and fixed, complete all as specified and directed. |
| 43 | Supply and fix 150 mm long aluminum anodized barrel tower bolts of extruded section complete all as specified and directed. |
| 44 | Supply and fix 125 mm extruded aluminium alloy handles, fabricated type, anodised and fixed complete all as specified and directed. |
| 45 | Providing and fixing aluminium hanging door stopper, (Twin rubber stopper) ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc complete all as specified and directed. |
| 46 | Supplying and fixing in repairs rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strenght conforming to IS : 4454- Part 1 and M.S top cover of required thickness for rolling shutters 0.80x1.25mm MS laths with 1.25 mm thick top cover complete all as specified and directed. |
| 47 | Supply and fix in repair of safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 48 | Providing and fixing in repairs ball bearing for rolling shutters complete all as specified and directed. |
| 49 | Providing and fxing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a primin coat of approved steel primer complete all as specified and directed. |
| 50 | Providing and fxing MS grills of required pattern in frames of windows etc with MS flats, square or round bars etc. fixed to steel window including primning coat with approved steel primer complete all as specified and directed. |
| 51 | Disconnecting damaged overhead / terrace PVC water tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 52 | Providing and placing on terrace (at all floor level) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 53 | Dismantling GI pipes 15mm to 40mm nominal bore including excavation and refilling trenches after taking out the pipes, manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge. |
| 54 | Providing and fixing 15 mm bore Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints concealed work, including cutting chases and making good the walls etc. upto fourth floor complete all as specified and directed by Engineer in Charge. |
| 55 | Providing and fixing 20 mm bore Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints as external work upto fourth floor complete all as specified and directed by Engineer in Charge. |
| 56 | Providing and fixing gun metal gate valve 20mm nominal bore with CI wheel of approved quality (screwed end) complete all as specified and directed. |
| 57 | Providing and fixing in repairs CP brass angle valve for wash basin/flush tank of approved quality conforming to IS : 8931, 15mm nominal bore complete all as specified and directed. |
| 58 | Providing and Fixing in repairs white Vitreous china Orissa pattern W.C. pan of size 580 mm x 440 mm with integral type foot rests water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required complete all as specified and directed. |
| 59 | Providing and fixing in repairs white vitreous wash basin of size 630 x 450 mm with a single 15 mm chromium plated brass pillar tap with CI brakcets, 15 mm chromium plated brass pillar taps 32mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required complete all as specified and directed. |
| 60 | Providing and fixing in repairs white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm sizes including flush pipe, spreader and other fittings respectively. |
| 61 | Providing and fixing in repairs 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete all as specified and directed. |
| 62 | Providing and fixing in repairs CP towel rail 600mm long with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190 gms complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour complete all as specified and directed. |
| 63 | Supply and fix in repairs unplasticised PVC connection pipe 15mm bore with brass union 45 cm long complete all as specified and directed |
| 64 | Providing and fixing CP brass bib cock of approved quality conforming to IS:8931, 15mm nominal bore complete all as spcified and directed. |
| 65 | Supply and fix in repairs cast iron floor trap 75mm dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 66 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including celaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 67 | Supply and fix 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls complete all as specified and directed. |
| 68 | Supply and fix 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls complete all as specified and directed. |
| 69 | Supply and fix 75 mm PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 70 | Supply and fix 110 mm PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 71 | Demolishing brick work in cement mortar manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 72 | Providing and laying brick work with common burnt clay machine moulded perforated modular perforated modular bricks of class designation 12.5 conforming to IS:2222 in exposed brick work including making horizontal and vertical grooves 10mm wide 12mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) above plint level upto floor V level. |
| 73 | Demolishing RCC work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 74 | Providing and laying reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15⁰ landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20mm nominal size Recycled Concrete Aggregate (RCA) upto 20%) complete all as specified and directed. |
| 75 | Material and labour for centering and shuttering including strutting, propping etc. and removal of form for weather shade, chajjas, roof, corbels etc. including edges complete all as specified and directed. |
| 76 | Material and labour steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level complete all as specified and directed. |
| 77 | Providing and laying factory made chamfered edge 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. Cement concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by Engineer-in-Charge. |
| 78 | Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer's complete all as specified and directed of Engineer -in- charge. |
| 79 | Supply and fix Factory made solid panel PVC door shutter 35 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engineer-in-Charge. |
| 80 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to sotre for keeping in safe custody or for taking credit (credit for above itmes should be made as per conditions separately) and making disturbed surfaces of wall and floors etc. complete all as specified and directed. |
| 81 | Dismantling of ceiling fan / exhaust fan and painting the same with one or more coats of spray painting with synthetic eanmel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required including pasting soft stickers indicating MES No of 25mm size of each letter with black synthetic enamel paint etc complete all as specified and directed. |
| 82 | Material and labour for Group 'A' Wiring for light point / socket point / fan point / exhaust fan point / call bell point with 1.5 sq mm FRLS PVC insulated unsheathed copper conductor single core multistand copper conductor FRLS cable drawn into and including concealed PVC conduit, with modular swtich, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. complete all as specified and required:-(a) For one light point controlled by one, one way switch |
| 83 | (b) All as per item No 82 above but for one ceiling / exhaust /wall fan point controlled by one, one way switch |
| 84 | (c) All as per Item No 82 above but One 3 pin 5A Socket outlet controlled by one switch independent board |
| 85 | Material and labour for wiring for one 3 pin socket outlet, 15 amps, independent, with cable 4 Sqmm size including concealed PVC conduit and conduit accessories |
| 86 | Supply and fixing following modular switch / socket on the existing modular plate & switch box including connectins but excluding modular plate etc as required.(a) 15/16 Amp switch, 1 module |
| 87 | (b) 6 Pin 15/16 A socket outlet |
| 88 | (c) 3/5 Pin 5/6A socket outlet |
| 89 | Supplying and fixing in two module stepped type electronic fan regulator on the exising modular plate switch box including connections but excluding modular plate etc.complete all as specified and directed |
| 90 | Supply and fixing in 3 module (100mm x 75mm) size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 91 | Supply and fix in ceiling rose 3 terminal 240 volts, 5 Amps complete all as specified and directed. |
| 92 | Supply and Fixing LED batten light 36 watt (system lumen efficacy >135 lm/Watt) supplying, installation, testing & commissioning of LED surface mounted batten light of following body material and construction as per IS : 10322 with driver (replaceable) as per the requirement with driver efficiency >85%, operating voltage AC 140-270 Volt, frequency 50/60 Hz, Operating temp range -5°C to 40 °C, internal surge protection of 2.5 KV with short & open circuit protection, THD <10%, P.F.≥0.95, IP20, CRI>80, flicker free (flicker shoule be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning hours with 70% of initial lumen maintained till life ends, CCT 3000⁰K /4000⁰K / 5700⁰K / 6500⁰K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not be more than the specified rating and fixture shall be of relevant BIS standard. Manufactures word mark / Name engraved / embossing / screen printing on housing complete in all respect including external connections with 1.5 Sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc as required with minimum 5 year OEM warranty. System lumen efficacy >135 lm/watt output. LM79 and LM80 test report and all testing required for LED fixtures as per BIS shall be submitted. Shape and size and CCT shall be as approved by Engineer-in-charge as per requirement. (Thermal management : heat sink of aluminium housing such |
| 93 | Supply and fixing in basic all purpose surface and wall mounted LED batten 10 watt, 2 feet with aluminium housing and integrated electronic driver complete all as specified and directed. |
| 94 | Supply and fixing LED street light 36 watt powder coated pressure die cast aluminium body (system lumen efficacy >120, 85% Input voltage 140-270 Volt AC, frequency 50/60 Hz, Operating temp range -5°C to 50 °C, internal surge protection of 5 KV, L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F.≥0.95, IP-66, IK-10, CRI>70, under voltage protection, EMI EMC as per CISPR 15, lenses for beam anlge as per IESNA type I/II/III as per the with of the road and the project requirement, suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry), of minimum 50000 Burning hours with 70% of initial lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000⁰K /4000⁰K / 5700⁰K / 6500⁰K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) complete all as specified and directed. |
| 95 | Supply and fixing 32mm dia x 2 metres long GI pipe (medium class bracket for mounting of street light fitting on pole including bending the pipe to the required shape, 2 Nos 40mm x 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and paint etc. complete all as specified and directed. |
| 96 | Material and labour for wiring for circuit, submain wirng along with earth wire with the 2x2.5 Sqmm + 1x2.5 Sqmm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 97 | Material and labour for wiring for circuit, submain wirng along with earth wire with the 2x4 Sqmm + 1x4 Sqmm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 98 | Supply and fixing in repairs 12 way (4+36), double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc as required (But without MCB/RCCB/Isolator). |
| 99 | Supply, fixing, testing and commissioning in repairs 63A rating, four pole, (three phase and neutral), 415V, Miniature circuit breaker(MCB), C-Curve, 10 KA complete all as specified and directed. |
| 100 | Supply and fixing in repairs 5 to 32 Amps rating , 240/415V, 10 KA \\"C\\" curve, miniature circuit breaker suitable for inductive load of single pole in the MCB DB complete with connections, testing and commissioining etc complete all as specified and directed. |
| 101 | Supply and fixing in repairs 5 to 32 Amps rating, 240/415V, 10 KA \\"C\\" curve, miniature circuit breaker suitable for inductive load of single pole and neutral in the existing MCB DB complete with connections, testing and commissioining etc complete all as specified and directed. |
| 102 | Supplying and fixing in repairs 2 way Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc complete all as specified and directed. |
| 103 | Supply and fixing in repairs earthing with GI earth plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required. Note Any type of strata. |
| 104 | Providing and laying earth connection from earth electrode with 6 SWG dia GI wire in 15mm dia GI pipe from earth electrode including connection with GI thimble excavation and re-filling as required. |
| 105 | Taking down copper / aluminium sub main wiring of any size for removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender