Housing Urban and Rular Development Government Departments Closing in 7 days TDR #56445967

Tender For Construction Of Girls Govt Hostel Building & Residential Quarters At Pad Ura Chhatrapati Sambhaji Nagar, Dist.Chhatrapati Sambhaji Nagar (Capacity 1000)

Issued by Government Departments · Aurangabad, Maharashtra
Tender Value
86.47 Crore
Estimated cost
Bid Submission
28 Jul 2026
7 days left
EMD
43.24 Lakhs
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Aurangabad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Girls Govt Hostel Building & Residential Quarters At Pad Ura Chhatrapati Sambhaji Nagar, Dist.Chhatrapati Sambhaji Nagar (Capacity 1000)

BOQ

Name of Work:- CONSTRUCTION OF GIRLS GOVT HOSTEL BUILDING & RESIDENTIAL QUARTERS AT PAD URA CHHATRAPATI SAMBHAJI NAGAR, DIST.CHHATRAPATI SAMBHAJI NAGAR (CAPACITY 1000)
Sl. No. Item Description
1PART A - WORK PORTION
2Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete.
3Ground Floor
4Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material with all lifts and leads beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
5Ground Floor
6Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material with all lifts and leads beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
7Ground Floor
8Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 3.0m To 4.5 m.) By MechanicalMeans
9Ground Floor
10Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material with all lifts and leads beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift from upto 4.5 to 6.0m). By Mechanical Means ( For All depths)
11Ground Floor
12Filling in plinth and floors with approved excavated material in 15cm. to 20cm.Layers including watering and compacting etc. complete.
13Ground Floor
14Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering andcompaction etc. complete.
15Ground Floor
16Coveyance of material/Debris at a distance of 5km as directed by the Engineer In charge ( Lead charges of \\" Rubbish as per Lead statement C-1 page 559 of SSR 2022-23 for 10 Km
17Ground Floor
18Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.
19Ground Floor
20Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cmthick including hand packing and compacting etc. complete.
21Ground Floor
22Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep withnecessary refilling with bitumen etc. complete.
23Ground Floor
24Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
25Ground Floor
26Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
27Ground Floor
28Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
29Ground Floor
30Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
31Ground Floor
32Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
33Ground Floor
34Providing and laying in situ / ready mix M35 RCC of trap/ granite/ quartzite/ gneiss metal for RCC work of Retaining Wall ,ballast walls, kerbs and box returns including scaffolding, compaction, formwork finishing and curing etc. complete. (excluding reinforcement, with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with fine agreegates of required specifications ( VSI sand finely washed etc ) RCC work of Box Cell
35Ground Floor
36First Floor
37Second Floor
38Third Floor
39Fourth Floor
40Fifth Floor
41Sixth Floor
42Seventh Floor
43Eighth Floor
44Nineth Floor
45Tenth Floor
46Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCAD Aenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
47Ground Floor
48First Floor
49Second Floor
50Third Floor
51Fourth Floor
52Fifth Floor
53Sixth Floor
54Seventh Floor
55Eighth Floor
56Nineth Floor
57Tenth Floor
58Providing and laying Cast in situ/Ready Mixcement concrete M-35 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
59Ground Floor
60First Floor
61Second Floor
62Third Floor
63Fourth Floor
64Fifth Floor
65Sixth Floor
66Seventh Floor
67Eighth Floor
68Nineth Floor
69Tenth Floor
70Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
71Ground Floor
72First Floor
73Second Floor
74Third Floor
75Fourth Floor
76Fifth Floor
77Sixth Floor
78Seventh Floor
79Eighth Floor
80Nineth Floor
81Tenth Floor
82Providing and laying Cast in situ/Ready Mix cement concrete in M-35 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
83Ground Floor
84First Floor
85Second Floor
86Third Floor
87Fourth Floor
88Fifth Floor
89Sixth Floor
90Seventh Floor
91Eighth Floor
92Nineth Floor
93Tenth Floor
94Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
95Ground Floor
96First Floor
97Second Floor
98Third Floor
99Fourth Floor
100Fifth Floor
101Sixth Floor
102Seventh Floor
103Eighth Floor
104Nineth Floor
105Tenth Floor
106Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and drawings including steel centering, formwork, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing etc. complete (excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)
107Ground Floor
108Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
109Ground Floor
110First Floor
111Second Floor
112Third Floor
113Fourth Floor
114Fifth Floor
115Sixth Floor
116Seventh Floor
117Eighth Floor
118Nineth Floor
119Tenth Floor
120Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
121Ground Floor
122First Floor
123Second Floor
124Third Floor
125Fourth Floor
126Fifth Floor
127Sixth Floor
128Seventh Floor
129Eighth Floor
130Nineth Floor
131Tenth Floor
132Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete.
133Ground Floor
134First Floor
135Second Floor
136Third Floor
137Fourth Floor
138Fifth Floor
139Sixth Floor
140Seventh Floor
141Eighth Floor
142Nineth Floor
143Tenth Floor
144Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge.
145Ground Floor
146Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces andfinishing as directed etc. Complete.
147Ground Floor
148First Floor
149Second Floor
150Third Floor
151Fourth Floor
152Fifth Floor
153Sixth Floor
154Seventh Floor
155Eighth Floor
156Nineth Floor
157Tenth Floor
158Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed.
159Ground Floor
160First Floor
161Second Floor
162Third Floor
163Fourth Floor
164Fifth Floor
165Sixth Floor
166Seventh Floor
167Eighth Floor
168Nineth Floor
169Tenth Floor
170Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed.
171Ground Floor
172First Floor
173Second Floor
174Third Floor
175Fourth Floor
176Fifth Floor
177Sixth Floor
178Seventh Floor
179Eighth Floor
180Nineth Floor
181Tenth Floor
182Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Completeas directed.
183Tenth Floor
184Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
185Ground Floor
186Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
187Ground Floor
188First Floor
189Second Floor
190Third Floor
191Fourth Floor
192Fifth Floor
193Sixth Floor
194Seventh Floor
195Eighth Floor
196Nineth Floor
197Tenth Floor
198Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
199Ground Floor
200First Floor
201Second Floor
202Third Floor
203Fourth Floor
204Fifth Floor
205Sixth Floor
206Seventh Floor
207Eighth Floor
208Nineth Floor
209Tenth Floor
210Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc.complete.
211Ground Floor
212First Floor
213Second Floor
214Third Floor
215Fourth Floor
216Fifth Floor
217Sixth Floor
218Seventh Floor
219Eighth Floor
220Nineth Floor
221Tenth Floor
222Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffoldingand curing etc. complete.
223Ground Floor
224First Floor
225Second Floor
226Third Floor
227Fourth Floor
228Fifth Floor
229Sixth Floor
230Seventh Floor
231Eighth Floor
232Nineth Floor
233Tenth Floor
234Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing andFinishing the surface scaffolding etc.complete.
235Ground Floor
236First Floor
237Second Floor
238Third Floor
239Fourth Floor
240Fifth Floor
241Sixth Floor
242Seventh Floor
243Eighth Floor
244Nineth Floor
245Tenth Floor
246Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
247Ground Floor
248First Floor
249Second Floor
250Third Floor
251Fourth Floor
252Fifth Floor
253Sixth Floor
254Seventh Floor
255Eighth Floor
256Nineth Floor
257Tenth Floor
258Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.
259Ground Floor
260First Floor
261Second Floor
262Third Floor
263Fourth Floor
264Fifth Floor
265Sixth Floor
266Seventh Floor
267Eighth Floor
268Nineth Floor
269Tenth Floor
270Providing internal cement plaster 25 mm thick in single coat using Ready to use wall plaster in cement mortar 1:4 to concrete, brick, stone surfaces in all positions including scaffolding and curing. Providing groove at joint of B.B. Masonry and concrete members complete.With Prior Approval of Concerned S.E.
271Ground Floor
272First Floor
273Second Floor
274Third Floor
275Fourth Floor
276Fifth Floor
277Sixth Floor
278Seventh Floor
279Eighth Floor
280Nineth Floor
281Tenth Floor
282Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
283Ground Floor
284First Floor
285Second Floor
286Third Floor
287Fourth Floor
288Fifth Floor
289Sixth Floor
290Seventh Floor
291Eighth Floor
292Nineth Floor
293Tenth Floor
294Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.
295Ground Floor
296Fourth Floor
297Tenth Floor
298Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
299First Floor
300Second Floor
301Third Floor
302Fourth Floor
303Tenth Floor
304Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
305Ground Floor
306First Floor
307Second Floor
308Third Floor
309Fourth Floor
310Fifth Floor
311Sixth Floor
312Seventh Floor
313Eighth Floor
314Nineth Floor
315Tenth Floor
316Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding testetc. complete.
317Ground Floor
318First Floor
319Second Floor
320Third Floor
321Fourth Floor
322Fifth Floor
323Sixth Floor
324Seventh Floor
325Eighth Floor
326Nineth Floor
327Tenth Floor
328Providing and laying Vitrified tlles (Matt and Antiskid finish) In floor in 800milimeter x 1200milimeter sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S: 15622, of approved brand and manufacturer, in all colours and shade, lald on 20 millmeter thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slury @3.3 kg/sgm including grouting the joints with white cement and matching pigments excetra The tiles must be cut with the zero chipping diametermond cutter only Laying of tiles will be done with the notch trowel, plier, wedge clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.as directed by engineer-in- Charge.
329Ground Floor
330First Floor
331Second Floor
332Third Floor
333Fourth Floor
334Fifth Floor
335Sixth Floor
336Seventh Floor
337Eighth Floor
338Nineth Floor
339Tenth Floor
340Providing and laying Vitrified tiles ( Matt and Antiskid Finish) in floor in 800milimeter x 1200milimeter sizes ( thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS: 15622 of approved brand and manufacturer, in all colours and shade, in skirting,risers of steps,over 12mm thick Bed of cement mortat 1:3 (1 cement:3coarse sand), jointing with gray cement slurry @3.3 Kg/Sqm including grouting the joint with white cement & matching pigments etc complete. s directed by engineer-in-charge.
341Ground Floor
342First Floor
343Second Floor
344Third Floor
345Fourth Floor
346Fifth Floor
347Sixth Floor
348Seventh Floor
349Eighth Floor
350Nineth Floor
351Tenth Floor
352Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curingand cleaning etc. complete.
353Ground Floor
354First Floor
355Second Floor
356Third Floor
357Fourth Floor
358Fifth Floor
359Sixth Floor
360Seventh Floor
361Eighth Floor
362Nineth Floor
363Tenth Floor
364Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc.complete
365Ground Floor
366First Floor
367Second Floor
368Third Floor
369Fourth Floor
370Fifth Floor
371Sixth Floor
372Seventh Floor
373Eighth Floor
374Nineth Floor
375Tenth Floor
376Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown/sira grey / kashmir white granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
377Ground Floor
378First Floor
379Second Floor
380Third Floor
381Fourth Floor
382Fifth Floor
383Sixth Floor
384Seventh Floor
385Eighth Floor
386Nineth Floor
387Tenth Floor
388Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown / sira grey / kashmir white granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing inC.M. 1:3 curing and cleaning etc. complete.
389Ground Floor
390First Floor
391Second Floor
392Third Floor
393Fourth Floor
394Fifth Floor
395Sixth Floor
396Seventh Floor
397Eighth Floor
398Nineth Floor
399Tenth Floor
400Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown / sira grey / kashmir white granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
401Ground Floor
402First Floor
403Second Floor
404Third Floor
405Fourth Floor
406Fifth Floor
407Sixth Floor
408Seventh Floor
409Eighth Floor
410Nineth Floor
411Tenth Floor
412Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)
413Ground Floor
414First Floor
415Second Floor
416Third Floor
417Fourth Floor
418Fifth Floor
419Sixth Floor
420Seventh Floor
421Eighth Floor
422Nineth Floor
423Tenth Floor
424Providing and fixing Indian teak wood planking 25 mm thick for flooring plained on both sides, tongued and grooved including scaffolding, if necessary, and one coat ofprimer etc. complete.
425Ground Floor
426Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (HeatReflective Paint).
427First Floor
428Fourth Floor
429Tenth Floor
430Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc.complete.
431Ground Floor
432First Floor
433Second Floor
434Third Floor
435Fourth Floor
436Fifth Floor
437Sixth Floor
438Seventh Floor
439Eighth Floor
440Nineth Floor
441Tenth Floor
442Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.)
443Ground Floor
444First Floor
445Second Floor
446Third Floor
447Fourth Floor
448Fifth Floor
449Sixth Floor
450Seventh Floor
451Eighth Floor
452Nineth Floor
453Tenth Floor
454Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete
455Ground Floor
456First Floor
457Second Floor
458Third Floor
459Fourth Floor
460Fifth Floor
461Sixth Floor
462Seventh Floor
463Eighth Floor
464Nineth Floor
465Tenth Floor
466Providing & Fixing 44MM thick both side LAMINATED DOOR (WITHOUT GLASS) made up of 18mm thick COMMERTIOL (ISI-303) plywood frame covered with 12mm thick COMMERTIOL (ISI-303) plywood both side of the frame to get required thickness as per architectural design & drawing with both side Cover with 1.00mm thick LAMINATE confirming to (ISI 2046) Premium quality with grove, edges finish with 50 X 10mm BTC lipping as per drawing is fitted by BTC 22 X 10mm moulding including all materials brass screw, brass hinges (125 X 12mm,) mortice lock, door stopper, antitermite treatment to plywood, two coats melamine pollish to moulding and lipping, labour charges as directed by engineer Incharge etc complete
467Ground Floor
468Solid Core Flush door Single leafProviding and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter
469Ground Floor
470First Floor
471Second Floor
472Third Floor
473Fourth Floor
474Fifth Floor
475Sixth Floor
476Seventh Floor
477Eighth Floor
478Nineth Floor
479Tenth Floor
480Solid Core Flush door Double leafProviding and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202– 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter
481Ground Floor
482First Floor
483Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
484Ground Floor
485First Floor
486Second Floor
487Third Floor
488Fourth Floor
489Fifth Floor
490Sixth Floor
491Seventh Floor
492Eighth Floor
493Nineth Floor
494Tenth Floor
495Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL/CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete.
496Ground Floor
497First Floor
498Second Floor
499Third Floor
500Fourth Floor
501Fifth Floor
502Sixth Floor
503Seventh Floor
504Eighth Floor
505Nineth Floor
506Tenth Floor
507Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm,3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.Complete
508Ground Floor
509First Floor
510Second Floor
511Third Floor
512Fourth Floor
513Fifth Floor
514Sixth Floor
515Seventh Floor
516Eighth Floor
517Nineth Floor
518Tenth Floor
519Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box
520Ground Floor
521First Floor
522Second Floor
523Third Floor
524Fourth Floor
525Fifth Floor
526Sixth Floor
527Seventh Floor
528Eighth Floor
529Nineth Floor
530Tenth Floor
531Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.
532Ground Floor
533First Floor
534Second Floor
535Third Floor
536Fourth Floor
537Fifth Floor
538Sixth Floor
539Seventh Floor
540Eighth Floor
541Nineth Floor
542Tenth Floor
543Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete
544Ground Floor
545First Floor
546Second Floor
547Third Floor
548Fourth Floor
549Fifth Floor
550Sixth Floor
551Seventh Floor
552Eighth Floor
553Nineth Floor
554Tenth Floor
555Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.
556Ground Floor
557First Floor
558Second Floor
559Third Floor
560Fourth Floor
561Fifth Floor
562Sixth Floor
563Seventh Floor
564Eighth Floor
565Nineth Floor
566Tenth Floor
567Providing and fixing Modular false ceiling of 600 x 600 mm center to center and 13 mm thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m at 60 cms center center and fixed with ½” x ½” (15 x 15 mm) flanges weighing 0.19 Kilogram/m suspended on 6 mm dia mild steel rod weighing 0.22 Kilogram/m, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 mm x 40 mm) weighing 0.39 Kilogram/m etc. (all alluminium sections shall be anodized) including all labour, material, lifts etc. complete.
568Ground Floor
569First Floor
570Second Floor
571Third Floor
572Fourth Floor
573Fifth Floor
574Sixth Floor
575Seventh Floor
576Eighth Floor
577Nineth Floor
578Tenth Floor
579Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should betaped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
580Ground Floor
581First Floor
582Second Floor
583Third Floor
584Fourth Floor
585Fifth Floor
586Sixth Floor
587Seventh Floor
588Eighth Floor
589Nineth Floor
590Tenth Floor
591Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA andBS 476 etc. complete.
592Ground Floor
593First Floor
594Second Floor
595Third Floor
596Fourth Floor
597Fifth Floor
598Sixth Floor
599Seventh Floor
600Eighth Floor
601Nineth Floor
602Tenth Floor
603Providing and fixing glazing panels & doors using 12mm thk toughen clear glass (confirming to ASTM Standards C-1048) supported byc-channel (embedded in the floor) at the bottom & side edge and wall connecting profile at the top edge,stainless steel articulated countersunk bolts threaded bolts,chemical fasterners,etc., glass panel size as per design and drawing including applying colourless sealant of joint incl. required edge polish, making glazing water tight etc. Destructive node joint test reports to be submitted forestablishing the safety factor, including operating hardware, SS patch fittings, fabricated long length satin finish SS 304 handles,patchlock, floor springs etc., complete as directed by the architect for frameless patch doors,single or twin leaf shutters with fixed
604Ground Floor
605First Floor
606Second Floor
607Third Floor
608Fourth Floor
609Fifth Floor
610Sixth Floor
611Seventh Floor
612Eighth Floor
613Nineth Floor
614Tenth Floor
615Providing structural glezing using min.6mm thick saint-gobain make reflective glass in any shade as per requirement.it includes aluminium framework of rectangular aluminium tube of size 64mm X 58mm and electro coloured to 15 microns .the aluminium extrusions is manufactured asper IS 63400.dow corning 995 silicone StructuralGlazing sealant is to be used for fixing glass with aluminium frame.high quality expansion bolts with good load bearing capacity is to be used for fixing aluminium frame to wall.it alsoincludes scaffolding and other necessary fittings.R.A. Unit : 1 / Square Metre
616Ground Floor
617Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 50 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both side, fixing in cement mortar 1:3 and curing etc. complete
618Ground Floor
619First Floor
620Second Floor
621Third Floor
622Fourth Floor
623Fifth Floor
624Sixth Floor
625Seventh Floor
626Eighth Floor
627Nineth Floor
628Tenth Floor
629Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete.
630Ground Floor
631First Floor
632Second Floor
633Third Floor
634Fourth Floor
635Fifth Floor
636Sixth Floor
637Seventh Floor
638Eighth Floor
639Nineth Floor
640Tenth Floor
641Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: ForItem One Number 15 to 18 prior approval of Superintending Engineer will be necessary
642Ground Floor
643First Floor
644Second Floor
645Third Floor
646Fourth Floor
647Fifth Floor
648Sixth Floor
649Seventh Floor
650Eighth Floor
651Nineth Floor
652Tenth Floor
653Providing & Fixing Invisible Grill made up of frume by Aluminium Track 3\\" Spacing For Invisible Grill In Bottom And Top Placing OF NS Wire Ropes or holding 3mm S.S. 316 grade non magnetic nylon coated wire fixed vertically at 75 mm C'enter to C'enter distance and two rows horizontally. Ima S.S. stiffiner is fixod at every Horizontal and Vertical Jumetion Point for and Janm aluminium copper ferrul used for start & end point of ss. wire aut every Eye hook, Plastic Side Insert for tracks, Of Screw. Hex head with plug for s.s.wire locking purpose as per drawing attached. (Exelinling Externd Scaffolding) (for Mantralaya Building work only)
654First Floor
655Second Floor
656Third Floor
657Fourth Floor
658Fifth Floor
659Sixth Floor
660Seventh Floor
661Eighth Floor
662Nineth Floor
663Tenth Floor
664Providing and fixing self supporting steel roofing system (Proflex) for a Godown or alike made up of structural grade steel sheet of 912 millimeter width ( tolerance + / - 2 millimeter ), moulded at site using mechanical press dies to the desired curve and shape to form 605 millimeter wide interlocking panels . The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 32.5 meter having arch rise as 6.5 meter, arch length 37.7 meter. The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 1.60 millimeter ( tolerace + / -0.02 millimeter ) with alloy coating AZ 150 and paint coating of regular modified polyster, top coat 25 micron and bottom coat 12 micron as perapproved colour , including fixing hangers , clamps etc.as may be necessary of Proflex standard, including fixing sky light of 2 millimeter thick polycarbonate sheet of size 2' x 14' and turbo ventilator of 24'' diameter to be installed at every 30 feet along the length of roof including finishing , testing and cleaning etc. complete.
665Tenth Floor
666Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
667Ground Floor
668First Floor
669Second Floor
670Third Floor
671Fourth Floor
672Providing and applying two coats of synthetic enamel paint of approved colour to new/old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
673Ground Floor
674First Floor
675Second Floor
676Third Floor
677Fourth Floor
678Providing and laying polished hand cut Kotah Stone flooring 25mm to 30mm thick and 45cm to 55cm wide in plain/diamond pattern on a bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete.
679Ground Floor
680First Floor
681Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
682Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade)
683Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
684Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
685Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
686Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
687Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
688Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
689Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.
690Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete(Low VOC).
691Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry,including scaffolding, finishing, curing etc. complete.
692Providing patti/ band 75mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.
693Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.
694Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.
695Providing and fixing bituminous pad 25mm thick for expansion joints in retaining wall, compound wall etc. complete.
696Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete.
697Providing and erecting Y type barbed wire fencing with seven rows of wire with 2.45 mm dia G.I. pipe ( Rezan/ concentina coil (wire) ire 0.75 mm dia ) with hot dip and G.I. coated hooks as per drawing supported on M.S. angle 50 x 50 x 6 mm at 2.5 mtr. c/c including fixing and fastening with wire, painting M.S. angles with one coat of red leadprimer and two coat of oil paint etc. complete.
698Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coatsof approved shade Weight of gate 35 Kilogram/Smt.
699Providing and fixing factory made door/Window frames of required colour made with wood Polymer composite (WPC) extuded internal ribbed sections conforming to American Society for testing and materials (ASTM) in regard with density, tensile strength, flexural strength, Izod impact, water absorption and screw withdrawal strength with wall thickness of 5mm (+/1mm) and with frames having mitred joints at each corner, joined together by two nos. of 10 x 8 mm & 40 mm long PVC dovetail keys including hard wood piece support along the full vertical and horizontal length in rebate portion hole for fixing hinges and fixtures and the frames fixed to Walls/columns with 15 mm long dash fasteners/holdfasts (dash fasteners/holdfasts to be paid separately) etc. complete as per the direction of Engineer in charge,with prior approval of concerned SuperitendingEngineer.
700Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
701Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating without box
702Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment orstacking as directed.
703Supplying hard murum/ kankar at the road site, including conveying and stackingcomplete.
704Spreading hard murum/ soft murrum/ gravel or kankar for side width complete
705Compacting the hard murum side widths including laying in layers on each side withvibratory roller including artificial watering etc. complete.
706Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant MixMethod and Grading - II Material
707Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate)
708Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
709Providing and laying in situ cement concrete M -30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
710Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means -Grading I (Using Screening Type B (11.2 mm) Aggregate)
711Providing and fixing Indian teak wood planking 50 mm thick for flooring plained on both sides, tongued and grooved including scaffolding, if necessary, and one coat ofprimer etc. complete.
712Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength,thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine fine aggregate (natural sand/crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern.
713Providing and fixing heavy duty inter locking concrete Coloured paving blocks of60 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints andcleaning etc. complete
714Providing and casting in situ or precast tapering R.C.C. M-20 Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batchingand Mixing Plant
715Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38a)
716Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38b)
717Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .(As per P&G DSR 2022-23 Items of garden work,Sr No.47)
718Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:-Murraya(Kamini);Bag Size 7'' x 8\\"(plants list) 1(a) serial no 15.
719Providing on site required variety of HedgesWell Developed, Healthy Foliage / Half Bloom Stage , Free from Pest and Diseases. apart c/c.Name:-Bougavillae Thema ;Bag Size 8'' x 10\\"(plants list) 7(b) serial no 10.
720Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs.for a depth of 20 cms.(As per P&G DSR 2022- 23 Items of garden work,Sr No.5)
721Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilledlabour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23)
722Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 daysOnly (As per P&G DSR 2022-23 Items of garden work,Sr No.29)
723Maintainance of Newly Developed ShrubsArea. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31)
724Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 1 x 1 x 1m ( consolidated thickness).Quantity of soil 0.653 cum x 800/cum = 522.40/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45a)
725Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 1 x 1 x 1m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 19.85/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45b)
726Providing on site Flowering Trees Specification:- Minimum Girth 6 to 8 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Drooping Ashok ;Bag Size 13 x13'', ht 6- 8'(plants list sr no5,item no 6b )
727Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Gulmoharl;Bag Size 13 x13'', ht 6- 8'(plants list sr no4,item no 5b)
728Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kanchan;Bag Size 13 x13'', ht 6- 8'(plants list sr no6,item no 5b)
729Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Sita ashok;Bag Size 13x13'', ht 6- 8'(plants list sr no11,item no 5b)
730Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-KaduNeem;Bag Size 13 x13'', ht 6- 8'(plants list sr no7,item no 6b)
731Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Parijat;Bag Size 13 x13'', ht 6- 8'(plants list sr no9,item no 5b)
732Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Sonchafa Grafted ;Bag Size 10 x10'', ht 3- 4'(plants list sr no33,item no 1b)
733Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Sonmohor/Peltophorum ;Bag Size 13 x13'', ht 6- 18'(plants list sr no12,item no 5b)
734Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Deshi Badam ;Bag Size 18 x18'', ht 8- 10'(plants list sr no4,item no 6C)
735Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Drooping Ashok ;Bag Size 18 x18'', ht 8- 10'(plants list sr no5,item no 6C)
736Providing on site PalmsSpecification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Areca Palm ;Bag Size 18 x18'', ht 7- 8'(plants list sr no1,item no 11d)
737Providing on site PalmsSpecification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged... Apart c/c.Name:-Fox tail palm;Bag Size 18 x18'', ht 7- 10'(plants list sr no3,item no 11d)
738Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) inearth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.12)
739Filling fresh garden soil / silt & manure in excavated pit size area of 1.00 x 1.00 x 1.00m (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.22)
740Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 1.00 x 1.00 x 1.00m.(1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.27)
741Maintainance of Newly Planted tree varities having height 2mtr. - 4mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Srs No.35)
742Providing & Fixing Garden Bench with Arm of Approved design with cast iron/M.S. Powder Coated complete in all Respects, Fixed Firmly on finised Ground as Directed by Engineer in charge
743Painting Line, Dashes, Arrows etc on Roads in two coats on new work with ready mixed road marking paint confirming to I.S. 164 on Bituminous surface including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control (Over/Upto cm wide) (MORTH-803) -- SurfaceOver 10cm Wide On New Surface
744Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
745Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.2mm aluminum sheet Class B
746Directional signageDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6\\" x 9\\" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer in charge.
747Providing and laying in place 300mm x 300mm x 16mm cement tactile directional and warning tiles (for a person with visual impairment)of the approved brand and make and specified colour for outdoor floors such as footpath, courtyard, multimodals location etc. laid on 20mm thick base of cement mortar 1:4 (1 cement: 4 coarse sand) in all shapes and patterns including grouting the joints with white cement with matching pigments etc. complete as per direction of engineer in charge
748Providing and laying in place 300mm x 300mm x 9.8mm vitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete.
749Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. Height letter, figures including painting the lefters/figures with approved colour and shade complete
750Providing and fixing Road junction / Information sign board of size 1.20 m x 0.90 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 5 mm with cross bracing of size 35 x 35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65x 6 mm of 3.65 m. long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with M-20 cement concrete of 60 cm x 60 cm x 75 cm size as directed by Engineer-in- charge etc. complete. Mild Steel sheet with Engineering grade.
751Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
752Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
753Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
754Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
755Providing and laying in situ / ready mix M30 RCC of trap/ granite/ quartzite/ gneiss metal for RCC work of Retaining Wall ,ballast walls, kerbs and box returns including scaffolding, compaction, formwork finishing and curing etc. complete. (excluding reinforcement, with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with fine agreegates of required specifications ( VSI sand finely washed etc ) RCC work of Box Cell
756Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
757Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer.
758Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.
759Ground Floor
760First Floor
761Second Floor
762Third Floor
763Fourth Floor
764Fifth Floor
765Sixth Floor
7667th Refuse Floor
767Eighth Floor
768Nineth Floor
769Tenth Floor
770Providing and fixing coloured glazed earthenware Wash Hand Basin of 55cm x 40 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete.
771Ground Floor
772First Floor
773Second Floor
774Third Floor
775Fourth Floor
776Fifth Floor
777Sixth Floor
778Seventh Floor
779Eighth Floor
780Nineth Floor
781Tenth Floor
782Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
783Ground Floor
784First Floor
785Second Floor
786Third Floor
787Fourth Floor
788Fifth Floor
789Sixth Floor
790Seventh Floor
791Eighth Floor
792Nineth Floor
793Tenth Floor
794Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.
795Ground Floor
796First Floor
797Second Floor
798Third Floor
799Fourth Floor
800Fifth Floor
801Sixth Floor
802Seventh Floor
803Eighth Floor
804Nineth Floor
805Tenth Floor
806Providing and fixing sink cock with regular swinging spout (Wall / floor Mounted Model) with wall flange having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
807Ground Floor
808First Floor
809Second Floor
810Third Floor
811Fourth Floor
812Fifth Floor
813Sixth Floor
814Seventh Floor
815Eighth Floor
816Nineth Floor
817Tenth Floor
818Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
819Ground Floor
820First Floor
821Second Floor
822Third Floor
823Fourth Floor
824Fifth Floor
825Sixth Floor
826Seventh Floor
827Eighth Floor
828Nineth Floor
829Tenth Floor
830Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete.
831Ground Floor
832First Floor
833Second Floor
834Third Floor
835Fourth Floor
836Fifth Floor
837Sixth Floor
838Seventh Floor
839Eighth Floor
840Nineth Floor
841Tenth Floor
842Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connectionupto the outside face of wall etc complete.
843Ground Floor
844First Floor
845Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.
846Ground Floor
847First Floor
848Second Floor
849Third Floor
850Fourth Floor
851Fifth Floor
852Sixth Floor
853Seventh Floor
854Eighth Floor
855Nineth Floor
856Tenth Floor
857Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.
858Ground Floor
859First Floor
860Second Floor
861Third Floor
862Fourth Floor
863Fifth Floor
864Sixth Floor
865Seventh Floor
866Eighth Floor
867Nineth Floor
868Tenth Floor
869Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
870Ground Floor
871First Floor
872Second Floor
873Third Floor
874Fourth Floor
875Fifth Floor
876Sixth Floor
877Seventh Floor
878Eighth Floor
879Nineth Floor
880Tenth Floor
881Providing and fixing Orissa type white glazed earthenware water closet pan of size 260mm x 440mm x 580mm with approved make Slim wall hung cistern with installation kit including S or P trap with cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessoriesetc.complete.
882Ground Floor
883Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete as per the direction ofEngineer-In-charge.
884Ground Floor
885First Floor
886Second Floor
887Third Floor
888Fourth Floor
889Fifth Floor
890Sixth Floor
891Seventh Floor
892Eighth Floor
893Nineth Floor
894Tenth Floor
895Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.
896Ground Floor
897First Floor
898Second Floor
899Third Floor
900Fourth Floor
901Fifth Floor
902Sixth Floor
903Seventh Floor
904Eighth Floor
905Nineth Floor
906Tenth Floor
907Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
908Ground Floor
909First Floor
910Second Floor
911Third Floor
912Fourth Floor
913Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.
914Ground Floor
915First Floor
916Second Floor
917Third Floor
918Fourth Floor
919Fifth Floor
920Sixth Floor
921Seventh Floor
922Eighth Floor
923Nineth Floor
924Tenth Floor
925Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.
926Ground Floor
927First Floor
928Second Floor
929Third Floor
930Fourth Floor
931Fifth Floor
932Sixth Floor
933Seventh Floor
934Eighth Floor
935Nineth Floor
936Tenth Floor
937Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
938Ground Floor
939First Floor
940Second Floor
941Third Floor
942Fourth Floor
943Fifth Floor
944Sixth Floor
945Seventh Floor
946Eighth Floor
947Nineth Floor
948Tenth Floor
949Providing and fixing on walls/ceiling/floor 20 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.
950Ground Floor
951First Floor
952Second Floor
953Third Floor
954Fourth Floor
955Fifth Floor
956Sixth Floor
957Seventh Floor
958Eighth Floor
959Nineth Floor
960Tenth Floor
961Providing and fixing on walls/ ceiling/ floor 25 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
962Ground Floor
963First Floor
964Second Floor
965Third Floor
966Fourth Floor
967Fifth Floor
968Sixth Floor
969Seventh Floor
970Eighth Floor
971Nineth Floor
972Tenth Floor
973Providing and fixing on walls/ ceiling/ floor 32 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.
974Ground Floor
975First Floor
976Second Floor
977Third Floor
978Fourth Floor
979Fifth Floor
980Sixth Floor
981Seventh Floor
982Eighth Floor
983Nineth Floor
984Tenth Floor
985Providing and fixing on walls /ceiling/ floor 40 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.
986Ground Floor
987First Floor
988Second Floor
989Third Floor
990Fourth Floor
991Fifth Floor
992Sixth Floor
993Seventh Floor
994Eighth Floor
995Nineth Floor
996Tenth Floor
997Terrace Floor
998Providing and fixing on walls/ ceiling/ floor 50 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
999Ground Floor
1000First Floor
1001Second Floor
1002Third Floor
1003Fourth Floor
1004Fifth Floor
1005Sixth Floor
1006Seventh Floor
1007Eighth Floor
1008Nineth Floor
1009Tenth Floor
1010Providing and fixing on walls/ ceiling/ floors 20 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 1.93 Kilogram/meter with necessary fitting remaking good the demolished portion and applying primer of anti-corrosive oil paint, 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1011Ground Floor
1012First Floor
1013Second Floor
1014Third Floor
1015Fourth Floor
1016Fifth Floor
1017Sixth Floor
1018Seventh Floor
1019Eighth Floor
1020Nineth Floor
1021Tenth Floor
1022Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1023Ground Floor
1024First Floor
1025Second Floor
1026Third Floor
1027Fourth Floor
1028Fifth Floor
1029Sixth Floor
1030Seventh Floor
1031Eighth Floor
1032Nineth Floor
1033Tenth Floor
1034Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1035Ground Floor
1036First Floor
1037Second Floor
1038Third Floor
1039Fourth Floor
1040Fifth Floor
1041Sixth Floor
1042Seventh Floor
1043Eighth Floor
1044Nineth Floor
1045Tenth Floor
1046Providing and fixing on walls/ ceiling/ floors, 40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 4.49 Kilogram/meter with necessary fittings and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.
1047Ground Floor
1048First Floor
1049Second Floor
1050Third Floor
1051Fourth Floor
1052Fifth Floor
1053Sixth Floor
1054Seventh Floor
1055Eighth Floor
1056Nineth Floor
1057Tenth Floor
1058Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.
1059Ground Floor
1060First Floor
1061Second Floor
1062Third Floor
1063Fourth Floor
1064Fifth Floor
1065Sixth Floor
1066Seventh Floor
1067Eighth Floor
1068Nineth Floor
1069Tenth Floor
1070Providing and fixing on walls/ ceiling/ floors, 80 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 10.15 Kilogram/meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.
1071Ground Floor
1072First Floor
1073Second Floor
1074Third Floor
1075Fourth Floor
1076Fifth Floor
1077Sixth Floor
1078Seventh Floor
1079Eighth Floor
1080Nineth Floor
1081Tenth Floor
1082Providing and fixing on walls/ ceiling/ floors, 100 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 14.74 Kilogram/meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1083Ground Floor
1084First Floor
1085Second Floor
1086Third Floor
1087Fourth Floor
1088Fifth Floor
1089Sixth Floor
1090Seventh Floor
1091Eighth Floor
1092Nineth Floor
1093Tenth Floor
1094Providing and laying in trenches 25 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 2.49 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1095Ground Floor
1096Providing and laying in trenches 32 mm dia.medium grade having embossed as ISI Mark galvanised iron pipes ?of 3.20 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1097Ground Floor
1098Providing and laying in trenches 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 5.17 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1099Ground Floor
1100Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete
1101Ground Floor
1102First Floor
1103Second Floor
1104Third Floor
1105Fourth Floor
1106Fifth Floor
1107Sixth Floor
1108Seventh Floor
1109Eighth Floor
1110Nineth Floor
1111Tenth Floor
1112Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
1113Ground Floor
1114First Floor
1115Second Floor
1116Third Floor
1117Fourth Floor
1118Fifth Floor
1119Sixth Floor
1120Seventh Floor
1121Eighth Floor
1122Nineth Floor
1123Tenth Floor
1124Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
1125Ground Floor
1126First Floor
1127Second Floor
1128Third Floor
1129Fourth Floor
1130Fifth Floor
1131Sixth Floor
1132Seventh Floor
1133Eighth Floor
1134Nineth Floor
1135Tenth Floor
1136Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
1137Ground Floor
1138First Floor
1139Second Floor
1140Third Floor
1141Fourth Floor
1142Fifth Floor
1143Sixth Floor
1144Seventh Floor
1145Eighth Floor
1146Nineth Floor
1147Tenth Floor
1148Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
1149Ground Floor
1150First Floor
1151Second Floor
1152Third Floor
1153Fourth Floor
1154Fifth Floor
1155Sixth Floor
1156Seventh Floor
1157Eighth Floor
1158Nineth Floor
1159Tenth Floor
1160Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.
1161Ground Floor
1162First Floor
1163Second Floor
1164Third Floor
1165Fourth Floor
1166Fifth Floor
1167Sixth Floor
1168Seventh Floor
1169Eighth Floor
1170Nineth Floor
1171Tenth Floor
1172Providing and fixing screw down for 65 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
1173First Floor
1174Fourth Floor
1175Tenth Floor
1176Supplying & erecting cast iron double flange butterfly valve of size75/80 mm dia. complete as per specification no. FF-VL/BFV
1177Tenth Floor
1178Fourth Floor
1179Ground floor
1180Providing and fixing 25mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making lockingarrangement and lock. [Without chamber].
1181Ground floor
1182Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type Each flanged end pattern, PN16 pressure rating, SS screen, end connection withFlanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
1183Ground floor
1184Second Floor
1185Fourth Floor
1186Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1187Ground Floor
1188First Floor
1189Second Floor
1190Third Floor
1191Fourth Floor
1192Fifth Floor
1193Sixth Floor
1194Seventh Floor
1195Eighth Floor
1196Nineth Floor
1197Tenth Floor
1198Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
1199Ground Floor
1200First Floor
1201Second Floor
1202Third Floor
1203Fourth Floor
1204Fifth Floor
1205Sixth Floor
1206Seventh Floor
1207Eighth Floor
1208Nineth Floor
1209Tenth Floor
1210Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent,clamps etc. complete
1211Ground Floor
1212First Floor
1213Second Floor
1214Third Floor
1215Fourth Floor
1216Fifth Floor
1217Sixth Floor
1218Seventh Floor
1219Eighth Floor
1220Nineth Floor
1221Tenth Floor
1222Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe andwith necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
1223Ground Floor
1224First Floor
1225Second Floor
1226Third Floor
1227Fourth Floor
1228Fifth Floor
1229Sixth Floor
1230Seventh Floor
1231Eighth Floor
1232Nineth Floor
1233Tenth Floor
1234Providing and making lead joints for 150mm diameter cast iron pipe line including lead and testing
1235Ground Floor
1236First Floor
1237Second Floor
1238Third Floor
1239Fourth Floor
1240Fifth Floor
1241Sixth Floor
1242Seventh Floor
1243Eighth Floor
1244Nineth Floor
1245Tenth Floor
1246Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brandby Ex. Engr. is necessary before use)
1247Ground Floor
1248First Floor
1249Second Floor
1250Third Floor
1251Fourth Floor
1252Fifth Floor
1253Sixth Floor
1254Seventh Floor
1255Eighth Floor
1256Nineth Floor
1257Tenth Floor
1258Providing and fixing ISI 1729/2002 grade 100 mm dia Cast Iron Soil Pipes With lugs including plug bend necessary fittings such as bends, tees, single junction, double junction, slotted vent, offsets on wall or into the ground including filling joints with cement mortar 1:2 proportion fixing on wall by means of galvanised Mild Steel bracket of 30 x 5 mm plate and 8 mm square rod with Galvanised Iron clamp with washer as per design, drawing and as directed to keep pipe 50 mm away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of white oil paint including removing the existing pipe if necessary and conveying and stacking in PWD Chowky or as directed by Engineer-in-Charge.
1259Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
1260Ground Floor
1261First Floor
1262Second Floor
1263Third Floor
1264Fourth Floor
1265Fifth Floor
1266Sixth Floor
1267Seventh Floor
1268Eighth Floor
1269Nineth Floor
1270Tenth Floor
1271Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
1272Ground Floor
1273First Floor
1274Second Floor
1275Third Floor
1276Fourth Floor
1277Fifth Floor
1278Sixth Floor
1279Seventh Floor
1280Eighth Floor
1281Nineth Floor
1282Tenth Floor
1283Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.
1284Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.
1285Providing and constructing on sewer, B.B. masonry circular manhole with concentric cone 1.2 M dia. at bottom and 0.5 M dia. at top and upto a depth of 2.00 M with 23 cm brick work in CM 1:4 proportion excluding excavation including foundation concrete 250 mm thick and haunches and channels in C.C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 coping and providing and fixing approved make and quality FRP (Fibre-reinforced plastic). frame and cover of 56 cm dia.etc. complete as directed by Engineerin-charge.
1286Providing and constructing on sewer, B.B. masonry circular manhole concentric cone 1.5 M dia. at bottom and 0.5 M dia. at top and upto a depth of 5.00 M with 23 cm brick work, upto depth of 2 M from top and 35 cm thick brick work for balance depth in CM 1:4 proportion with 20 mm thick smooth plaster on both sides in CM 1:2 proportion excluding excavation including foundation concrete 250 mmthick and haunches and channels in C.C. 1:2:4 proportion, finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., 1:2:4 coping and providing and fixing approved make and quality FRP (Fibre-reinforced plastic) frame and cover of 56 cm dia. etc. complete as directed by Engineerin-charge.
1287Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for thegully trap.
1288Providing , Laying and fixing, jointing Eco Drain 250 mm SN-04 Nu-Drain Upvc pipe or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 & 16098 with fittings such a bends, tees, coupler, etc. jointing with rubber lubricant, including necessary excavation, trench refilling with selective excavated material etc.complete.
1289Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
1290Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
1291Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line,level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
1292Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars incement mortar 1:1 and refilling the trench complete.
1293Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars incement mortar 1:1 and refilling the trench complete.
1294RWH - Recharge PitProviding and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5\\" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end- caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technicalspecification and direction of the Engineer in charge.
1295Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (AntiCorossive Paint)
1296Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete.
1297Providing and laying 100 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation andrefilling the trenches) complete.
1298Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tankscapacity between 200 to 1000 liters
1299Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacityabove 1000 to 20,000 litres
1300Free Standing Table @ 1200Lx600Dx750HTProviding and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine.Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particleboard,
1301Ground Floor
1302First Floor
1303Second Floor
1304Third Floor
1305Fourth Floor
1306Fifth Floor
1307Sixth Floor
1308Seventh Floor
1309Eighth Floor
1310Nineth Floor
1311Tenth Floor
1312Medium Height Steel Storage @ 750Lx450Dx1200HTProviding and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk. as per drawing.
1313First Floor
1314Second Floor
1315Third Floor
1316Fourth Floor
1317Fifth Floor
1318Sixth Floor
1319Seventh Floor
1320Eighth Floor
1321Nineth Floor
1322Tenth Floor
1323Tea Table 900mm X 750mm X 450mm for m.s. ante chamberProviding And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc.
1324Ground Floor
1325Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT,Curvilinear Table Top @ 1500/1500Lx600/600D :- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
1326Ground Floor
1327First Floor
1328Wardrobe with Mirror @ 900LX 600DX 1965HProviding and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required.
1329First Floor
1330Second Floor
1331Third Floor
1332Fourth Floor
1333Fifth Floor
1334Sixth Floor
1335Seventh Floor
1336Eighth Floor
1337Nineth Floor
1338Tenth Floor
1339Bed Side Table @ 400LX 400DX 415HProviding and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding
1340Ground Floor
1341First Floor
1342Second Floor
1343Third Floor
1344Fourth Floor
1345Fifth Floor
1346Sixth Floor
1347Seventh Floor
1348Eighth Floor
1349Nineth Floor
1350Tenth Floor
1351Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht.Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments , Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color.
1352Ground Floor
1353First Floor
135412 Seater Reading Table for Library @ 3600Lx1200Dx750HTProviding and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.
1355First Floor
1356Medium Height Partition @ 1800/1200HTTILE BASED PARTITION SYSTEM:- Tile based Aluminum partition system of 1800/1200 mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/ exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look.Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board lower tiles in laminate finish of 9mm. thk. on both the sides.
1357First Floor
1358Second Floor
1359Third Floor
1360Fourth Floor
1361Fifth Floor
1362Sixth Floor
1363Seventh Floor
1364Eighth Floor
1365Nineth Floor
1366Tenth Floor
1367Book Case with Glass Shutter @ 825Lx300Dx1650HTProviding & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing.
1368First Floor
1369Low Height Openable Storage @ 900Lx450x750HTProviding and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk additional Top on top of storage as as per drawing
1370Ground Floor
1371Executive's Table @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing
1372Ground Floor
1373First Floor
1374Second Floor
1375Third Floor
1376Fourth Floor
1377Fifth Floor
1378Sixth Floor
1379Seventh Floor
1380Eighth Floor
1381Nineth Floor
1382Tenth Floor
1383Sofa Set 3+1+1Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length:182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat
1384Ground Floor
1385Single Bed @ 2025LX 1000DX 650HProviding and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow. Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm.Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side White laminate.
1386Ground Floor
1387First Floor
1388Second Floor
1389Third Floor
1390Fourth Floor
1391Fifth Floor
1392Sixth Floor
1393Seventh Floor
1394Eighth Floor
1395Nineth Floor
1396Tenth Floor
1397Public Seating Chair. - 3 SeaterProviding and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.
1398Ground Floor
1399Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery
1400Ground Floor
1401Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery
1402First Floor
1403Second Floor
1404Third Floor
1405Fourth Floor
1406Fifth Floor
1407Sixth Floor
1408Seventh Floor
1409Eighth Floor
1410Nineth Floor
1411Tenth Floor
1412Full Height Steel Storage @ 750Lx450Dx2100HTProviding and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.
1413Ground Floor
1414First Floor
1415Second Floor
1416Third Floor
1417Fourth Floor
1418Fifth Floor
1419Sixth Floor
1420Seventh Floor
1421Eighth Floor
1422Nineth Floor
1423Tenth Floor
1424ELECTRICAL
1425Providing External Electrification work to the Proposed Building of Girls Hostel At CH. Sambhaji Nagar,dist.CH.Sambhaji Nagar.
1426Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
1427Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
1428Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
1429Supplying and erecting PVC insulated PVC round sheathed 1sq.mm(32no. x0.20mmdia.)3core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 k
1430Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
1431Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
1432Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWGsheet,outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs.astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.
1433Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1434Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1435Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1436Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP
1437Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
1438Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole)
1439Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
1440Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).
1441Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (Strip) cable 1100 V, 3½ core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1442Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (Strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1443Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (Strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1444Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (Round) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1445Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP
1446Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
1447Providing Internal Electrification work to the Proposed Building of Girls Hostel At CH. Sambhaji Nagar,dist.CH.Sambhaji Nagar.
1448Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1449Supplying and laying HMS PVCconduit FRLS grade 25mmdia with necessary accessories in RCCwork/false ceiling/false flooring as perspecification No. WG-MA/CC.
1450Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1451Supplying and laying HMS PVC conduit FRLS grade 32mmdia. With necessary accessories in RCC work/falseceiling/false flooring as per specification No. WG-MA/CC.
1452Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW
1453Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
1454Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1455Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1456Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BW
1457Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BW
1458Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1459Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1460Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1461Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1462Supplying and erecting Ceiling rose / Batten holder / Slanting holder /hanging cord switch / hanging bell push / pendant holder bakelite base6A. erected on filled polypropylene board or polished double wooden block/PVC junction box.
1463Supplying and erecting modular type switch 6A/10A duly erected on provided plate and box with wiring connections complete
1464Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete
1465Supplying and erecting modular type 3pin 6A multi socket with safety shutter, duly erected on provided plate and box withwiring connections complete.
1466Supplying and erecting modular type 3 pin 6 / 16A multi socket with safetyshutter, duly erected on provided plate and box with wiring connections complete.
1467Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
1468Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.
1469Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1470Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1471Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1472Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1473Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1474Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
1475Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1476Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires,modular type switch,earthing and required accessories as per specification No: WG PW/CW
1477Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
1478Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
1479Wiring for plug on board with Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
1480Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW
1481Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
1482Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
1483Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
1484Supplying LED concealed type foot / step light with aluminium body forindoor/outdoor application suitable for 4W-6W LED including driver anderecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty.
1485Supplying and erecting bulk head LED fitting max. 10W with high transitivitydiffuser with system lumens output of min. 1100 lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f.>0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
1486Supplying and erecting anodized aluminium corridor / passage / mirror lightLED fitting (2 feet) Max. 12W with high transitivity diffuser with min. systemlumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCTupto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
1487Supplying and erecting CRCA powder coated corridor/passage light LEDfitting (4 feet) Max. 17W with high transitivity diffuser with system lumensoutput of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCTupto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
1488Supplying & erecting inverter LED batten 20W tube light fitting withpolycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600mAh Lithium ion Battery with charging time of 8-10 Hours and backup time ofMin. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life ofminimum 25000 hrs. with overheating protection with 2 years warranty.
1489Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
1490Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
1491Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
1492Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8Wcapacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
1493Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
1494Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, dulycharged with 24 months warranty complete
1495Supplying,erecting,testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC
1496Supplying and erecting ON LOAD four pole automatic transfer switch, 415V,400A, 50 Hz with enclosure, flexibility of neutral connection, line and loadreversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
1497Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB
1498Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1499Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1500Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1501Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1502Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB
1503Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1504Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1505Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1506Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1507Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness,surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbartype) as per specification no. SW-SWR/MCBDB
1508Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) asper specification no. SW-SWR/MCBDB
1509Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
1510Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1511Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB
1512Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1513Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation ofshunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB
1514Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breakingcapacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation ofshunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB
1515Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breakingcapacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation ofshunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1516Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, withovercurrent, rated short-circuit breaking capacity (10 kA) and earth leakageprotection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1517Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1518Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, withovercurrent, rated short-circuit breaking capacity (10 kA) and earth leakageprotection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO
1519Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1520Supplying & erecting 415V, 100A porcelain base neutral link complete erected in provided M.S. box.
1521Supplying & erecting porcelain/epoxy bus bar support complete erected inprovided M.S. box for 400A
1522Supplying and erecting terminal spreaders suitable for 4 pole, up to 100AMCCB (Set of 8)
1523Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8)
1524Supplying and erecting extended rotary handle for MCCB with adjustabletelescopic rod suitable for up to 250A MCCB.
1525Supplying and erecting metal work in CRCA sheet including Iron work forsupports with fabrication of boxes, panel boards, etc. including cutting,bending, drilling, welding, riveting, treated with anti-rust treatment and dulypowder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
1526Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, various sections of iron, plates, chequered plates, rods, bars, MSpipes, etc. for panel board or any other purpose with bending, cutting, drillingand welding complete erected at the position with necessary materials dulypainted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
1527Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
1528Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
1529Supplying and erecting AC Three Phase Four wire Multifunction EnergyMeter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting tomeasures and display parameters with RS485 Modbus communication port.mounting whole current operated meter to measures and display V, I, kWh,KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electricalparameters shall be available on com port with their mapping address openfor third party software
1530Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
1531Supplying & erecting LED type indicating pilot lamp with LED colour blue,230 / 250 V on provided box / panel with necessary material, wiring &connections etc.
1532Supplying, installation & marking of surge arrestor / surge protection deviceat the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for single phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
1533Supplying and erecting 50 kVAr, 3 phase, 50 Hz., Power contactors Deratedfor microprocessor APFC controller with MPP / APP type capacitor with 525V and having minimum overcurrent capacity of 1.8 In, peak inrush currentcapacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
1534Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware
1535Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware.
1536Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
1537Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (Strip) cable 1100 V, 3½ core 25 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
1538Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
1539Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW ACElectric Vehicle charger (suitable for 2/3/4 wheeler) having minimumIK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of outputcurrent of 16A 240V AC at each socket with 3.5\\"TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification.
1540Supply, Installation, Testing and Commissioning 7.2 kW AC Electric Vehiclecharger (suitable for 4 wheeler) having minimum IK08 & IP54 protectionsuitable for single phase, 230V AC, 50Hz, incoming and 1 nos. output having capacity of output current of 32A at 230V with Type two connector as per IEC 62196-2 , Interlocking arrangement & minimum 5 meter charging cable length, 3.5\\" TFT screen for human interface & LED light for status indication and metering for measurement of consumed energy having metering accuracy +/- 1%, one hour battery backup for server communication, emergency push stop button, with user interface by mobile application/QR Code/RIFD Card/Password Login and having short circuit, over & under voltage, overload, earth leakage ,Over temperature, surge protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification
1541Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) withinterconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.
1542Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1543Supplying and erecting SS enclosure for MCCB suitable for up to 100A MCCB
1544Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, various sections of iron, plates, chequered plates, rods, bars, MSpipes, etc. for panel board or any other purpose with bending, cutting, drillingand welding complete erected at the position with necessary materials dulypainted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
1545Supplying, installing, testing and commissioning of Commercial Heat pump, Each (New) having dimension : 1020 x 846 x 1840 (mm) max., Input power: 10.3 kW, 400 V, 3 Ph, 50 Hz, Output power: 38 kW having hot water temperature range 35°C to 52°C and ambient temperature range for max. efficiency 7°C to 43°C, with top throw fan, tube type heat exchanger 5 nos. inbuilt temperature sensor and two pressure sensors, centrally controlled operation, operational noise level: 65 dBA with provision for controlling auxiliary heater with necessary accessories complete with 5 years ON-SITE warranty.
1546Supplying, installation and testing and commissioning of storage type Mild Steel mixing water tank of capacity 5000 ltrs. tested to a pressure of 8 kg/cm2insulated with 50 mm thick rock wool with wire mesh around and cladded with 26 SWG aluminium of dish end type with working pressure of 6 kg/cm2, fabricated with 6 mm thick plate and dished ends with 8 mm thick plates complete with man hole cover, inner side of the tank coated with FRP coating of 3 mm thickness withstand temperature of 90°C provided with collars of 2\\" BSP for provision to install 6 numbers of electrical heating coils if required with thermal sensors for automatic operation and integrated into the electrical circuits of the circulation pumps and the heat pump with safety valve drain, inlet and outlet nozzle, pressure gauge with all necessary accessories complete. Separate water tank not required for item no. 4-6-1 to 4-6-3
1547Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1548Supplying and laying HMS PVCconduit FRLS grade 25mmdia with necessary accessories in RCC work/false ceiling/false flooring as perspecification No. WG-MA/CC.
1549Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW
1550Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
1551Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1552Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1553Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1554Supplying and erecting modular type switch 6A/10A duly erected on provided plate and box with wiring connections complete
1555Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete
1556Supplying and erecting modular type 3pin 6Amulti socket with safety shutter, duly erected on provided plate and box withwiring connections complete.
1557Supplying and erecting modular type 3 pin 6 / 16A multi socket with safetyshutter, duly erected on provided plate and box with wiring connections complete.
1558Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
1559Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1560Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1561Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1562Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1563Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1564Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
1565Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires,modular type switch,earthing and required accessories as per specification No: WG PW/CW
1566Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
1567Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
1568Wiring for plug on board with Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
1569Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW
1570Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
1571Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
1572Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
1573Supplying and erecting anodized aluminium corridor / passage / mirror lightLED fitting (2 feet) Max. 12W with high transitivity diffuser with min. systemlumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCTupto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
1574Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs.at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty
1575Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
1576Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
1577Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
1578Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 tounity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
1579Supplying and erecting12V/17Ah-18Ah SMF battery with battery terminalwire, duly charged with 12 months warranty complete.
1580Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1581Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB
1582Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1583Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1584Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB
1585Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1586Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, withovercurrent, rated short-circuit breaking capacity (10 kA) and earth leakageprotection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1587Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting andadjustable magnetic setting with provided leads, provision for installation ofshunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB
1588Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
1589Supplying & erecting LED type indicating pilot lamp with LED colour blue,230 / 250 V on provided box / panel with necessary material, wiring &connections etc.
1590Supplying, installation & marking of surge arrestor / surge protection deviceat the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for single phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
1591Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent,rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1592Supplying & erecting 415V, 100A porcelain base neutral link complete erected in provided M.S. box.
1593Supplying & erecting porcelain/epoxy bus bar support complete erected inprovided M.S. box for 400A
1594Supplying and erecting metal work in CRCA sheet including Iron work forsupports with fabrication of boxes, panel boards, etc. including cutting,bending, drilling, welding, riveting, treated with anti-rust treatment and dulypowder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
1595Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, various sections of iron, plates, chequered plates, rods, bars, MSpipes, etc. for panel board or any other purpose with bending, cutting, drillingand welding complete erected at the position with necessary materials dulypainted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
1596Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
1597Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
1598Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware
1599Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware.
1600Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (Strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid i provided trench/ pipe as per specification no. CB-LT/CU
1601Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP
1602Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
1603Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
1604Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
1605Supplying and laying HMS PVCconduit FRLS grade 25mmdia with necessary accessories in RCCwork/false ceiling/false flooring as perspecification No. WG-MA/CC.
1606Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places as per specification No: WG-MA/BW
1607Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
1608Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1609Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1610Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any otherplaces.as per specification No: WG-MA/BW
1611Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BW
1612Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1613Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1614Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
1615Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
1616Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW
1617Supplying and erecting modular type switch 6A/10A duly erected on provided plate and box with wiring connections complete
1618Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete
1619Supplying and erecting modular type 3pin 6Amulti socket with safety shutter, duly erected on provided plate and box withwiring connections complete.
1620Supplying and erecting modular type 3 pin 6 / 16A multi socket with safetyshutter, duly erected on provided plate and box with wiring connections complete.
1621Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
1622Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1623Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1624Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1625Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1626Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
1627Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
1628Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires,modular type switch,earthing and required accessories as per specification No: WG PW/CW
1629Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
1630Wiring for plug on board with Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
1631Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW
1632Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
1633Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
1634Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
1635Supplying and erecting anodized aluminium corridor / passage / mirror lightLED fitting (2 feet) Max. 12W with high transitivity diffuser with min. systemlumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCTupto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs.at L70B50, including driver with end caps on provided PVC Block / woodenboard with 3 years warranty.
1636Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs.at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty
1637Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
1638Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
1639Supplying, erecting, testing and commissioning of 2kVA capacity online puresine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 tounity output pf, single phase input & 1 phase output complete with allprotections as per specification no. AP-UPS
1640Supplying and erecting12V/17Ah-18Ah SMF battery with battery terminalwire, duly charged with 12 months warranty complete.
1641Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB
1642Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1643Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB
1644Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1645Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1646Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1647Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness,surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbartype) as per specification no. SW-SWR/MCBDB
1648Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCB DB
1649Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB
1650Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, withdoor, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GIframe as per specification no. SW-SWR/MCBDB
1651Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1652Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1653Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware.
1654Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (Round) cable 1100 V, 4 core 6 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid i provided trench/ pipe as per specification no. CB-LT/CU
1655Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (Round) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1656Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP
1657Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
1658Supplying and erecting storage type water heater 35 litres capacity havingstanding loss <0.584 kWh / 24 hour / 45°C, high impact resistanceengineering plastic body with anti corrosive high grade steel inner tankheating element having hard water & corrosion protection, with minimum3 safety protections (i.e. thermostat & thermal cut-out, function valve) withtotal pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH
1659Supplying and erecting chromium plated heavy duty brass stop cock for inletpipe of water heater (15mm. dia).
1660Supplying & erecting vacuum relief valve for storage water heater with necessarymaterials complete.
1661Supplying & erecting vacuum relief valve for storage water heater with necessarymaterials complete
1662Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8Wcapacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
1663Providing Area lighting,pump & generator system work to the Proposed Building of Girls Hostel At CH. Sambhaji Nagar,dist.CH.Sambhaji Nagar.
1664Supplying, erecting, testing and commissioning of diesel generating set conforming to CPCB-IV plus Emission Norms with alternator of 250 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2/G3 and maximum fuel consumption 42.30 ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with suitable capacity DEF tank standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 425 ltr etc., on provided M20 grade CC foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
1665Supplying and erecting PVC box trunking of size 50x50 mm. withaccessories on wall/ceiling as per specification No: WG-MA/BOX.
1666Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BW
1667Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1668Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1669Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1670Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1671Supplying & erecting 415V, 100A porcelain base neutral link complete erected in provided M.S. box.
1672Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A
1673Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8)
1674Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8)
1675Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
1676Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
1677Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
1678Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
1679Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
1680Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
1681Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
1682Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
1683Supplying, installation & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for single phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
1684Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP
1685Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
1686Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 250 kVA up to 320 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
1687Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
1688Providing CCTV work to the Proposed Building of Girls Hostel At CH. Sambhaji Nagar,dist.CH.Sambhaji Nagar.
1689Supplying & erecting of High definition 4/5 Megapixel IP IR PTZ Camera with following features:4/5 MP WDR 32x IR Network PTZ Camera.1/2.8” ox higher 4MP PS CMOS Image sensorMax. 4MP (2688 x 1520)@25fps or above /Max. 5MP (2880x1620)@25fps or above Instastream, H.265, H.264, H.264B, H.264H, MJPEG Support Triple stream, Storage - SFTP, NAS, Mirco SD card (Upto 256GB) Powerful 32x Optical and 16x Digital zoomWDR(120dB), 2D NR/ 3D NR, Day/Night(ICR), ROI, Defog, AWB, BLC Up to 300 Presets, S Scan, 8 Tour, S Pattern IR Range of 150 Mtr ox above.Support PoE, IP67, IIfi10, duly erected on wall/ceiling/provided pole with all accessories complete with 3 years warranty.
1690Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features 4/SMP Vandal Dome Camera. 1/2.7\\" ox higher 4MP PS CMOS Image Sensor Max. 4MP (2688 x 1520)@25fps or above /Max. 5MP (2880x1620)@25fps or above Instastream, H.265, H.264, H.264H, H.264B, MJPEG Support Quad Stream WDR(120dB), Day/Night(ICR), 3D NR, ROI, AWB, AGC, BLC, HLC, Digital watexmarking Support Built-in Mic IR Range of 30Mtr ox above., Warm Light Range of 30Mtr ox above.3.6mm fixed Lens (2.8mm, 6mm Optional) Support Starlight TechnologyMicro SD Card upto 256GB Supported, PoE, IP67, IIfi10 ISO 9001: 2015, ISO 20000-1 : 2018, CE, FCC and RoHS, BIS, STQC ERCertificate, duly erected on wall/ceiling/provided pole with all accessories complete with 3 years warranty.
1691Supplying & erecting of High defiriition 4/5 Megapixel IP IR Bullet Camera with following features 4/5 MP Bullet Camera. 1/2.7\\" ox higher 4MP PS CMOS Image SensorMax. 4MP (2688 x 1520)@25fps or above /Max. 5MP (2880x1620)@25fps or above Instastream, H.265, H.264, H.264H, H.264B, MJPEG Support Quad stream WDR(120dB), Day/Night(ICR), 3D NR, ROI, AWB, AGC, BLC, HLC, Digital watexmarkingIR Range of 30Mtr or above, Warm Light Range of 30Mtr or above. 3.6rrun fixed Lens (2.8rnm, 6mm Optional) Support Starlight TechnologyMicro SD Card upto 256GB Supported, PoE, IP67, IIfi10 ISO 9001: 2015, ISO 20000-1 : 2018, CE, FCC and RoHS, BIS, STQC ERCertificate, duly erected on wall/ceiling/provided pole with all accessories complete with 3 years warranty.
1692Supplying, installing, testing & commissioning of 64 Ch Network Video Recorder 64Ch. 4K AI Network Video Recorder Up to 64 channel IP camera input Max. Decoding capability: 32 1080p@30fpsMax. 320/384 Mbps Incoming/ Recording/ Outgoing bandwidthAI by Recorder: supports 8 channel face detection and recognition, up to 20 face databases and 200,000 face images, 8 channel metadata, 24 channel perimeter protection, 32 channel SMD Plus. AI by Camera: supports face detection and xecogrñtion, peñmeter protection, SMD Plus, metadata, ANPR, stereo analysis, heat map, and people countingSupport redundant power, RAID 0/1/5/6/10, N+M cluster Support 8 SATA HHDs up to 20TB Each, 4 USB Port2 HDMI / 2 YGA simultaneous video output RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specificationss no. CCTV-NVR complete with3 years warranty.
1693Supplying, installing, testing & commissioning of 32 Ch Network Video Recorder 32Ch. 4K AI Network Yideo Recorder Up to 32 channel IP camera input Max. 256 Mbps incoming/recording/outgoing bandwidth Instastream/H.265/Smart H.264+/H.264/MJPEG codec decoding Up to 12MP resolution preview and playback AI by Recorder: 2-channel face detection or recognition/ 4-channel perimeter protection/ 8-channel SMD Plus, AI by Camera: supports face detection and recognition, peâmeter protection, SMD Plus, metadata, ANPR, stereo analysis, heat map, and people counting Support 4 SATA HDDs up to 16TB Each, 3 USB Ports (2 USB 3.0)2 HDMI/ 2 VGA simultaneous video output Support Multi-brand network cameras RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and pxogxamining etc. complete as per specificationss no. CCTY-NVR complete with 3 years warranty.
1694Supplying, installing, testing & commissioning of 16 Ch Network Video Recorder 16Ch. 4K Network Video RecorderUp to 16 channel IP Instastream/H.265/Smart H.264+/H.264 codec decoding Up to 8MP resolution preview and playback200Mbps incoming bandwidth Up to 16 channel IP camera input Instastream/H.265/Smart H.264+/H.264 codec decodingUp to 8MP resolution preview and playback Max. 200Mbps incoming bandwidth Support 2 SATA HDDs up to 20TB Each, 2 USB Ports (1 front USB 2.0 port, 1 rear USB 3.0 port) HDMI/ VGA Heterogeneous video output Support Multi-brand network cameras RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specificationss no. CCTV-NVR complete with 3 years warranty.
1695Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of Each NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specifications CCTV-HDD complete with 3 years warranty.
1696Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete.
1697Supplying,fixing,and configuring 24ports,POEswitch in provided rack as per specification No. WG-NWC/ENS
1698Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
1699Supplying and laying HMS PVC conduit FRLS grade 25 mm dia withnecessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
1700Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
1701Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
1702Supplying & erecting 55\\" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following featuresBrightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg. Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W,Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-Monitor, complete with 1 years warranty.
1703Providing Fire Fighting & Fire alarm system work to the Proposed Building of Girls Hostel At CH. Sambhaji Nagar,dist.CH.Sambhaji Nagar.
1704Supplying, installation, testing and commissioning of main fire pump (MFP /EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m headdriven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or ofsuitable kW capacity for manual/automatic operation and consisting offollowing :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body &bronze impeller with stainless steel shaft (SS410 grade), mechanical sealconforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation on with IP 55 protection for enclosure, horizontal foot mountedtype with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/SSC/EP
1705Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body& bronze impeller with stainless steel shaft(SS410 grade), mechanical sealconforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation with IP 55 protection for enclosure, horizontal foot mounted typewith Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, asper specification no. FF-MFP/JP
1706Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of castiron body & bronze/CI impeller with stainless steel shaft (SS410 grade),mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation on with IP 55 protection for enclosure, horizontal foot mountedtype with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required.(d)Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/BP
1707Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body &bronze impeller with stainless steel shaft(SS410 grade), mechanical sealconforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standardcomplete with auto starting mechanism, 12/24 volts DC electric startingequipment with battery of required AH capacity with necessary charger suitable towork on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with firstfilling of diesel up to 100% level with necessary piping with valves up to engine ,exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mmthick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for autostop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith engine assembly and accessories duly painted with two coats of syntheticenamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932of 2003) complete, as per specification no. FF-MFP/SSC/DP
1708Supplying and erecting 300 mm dia 1.5m in height air vessel / tankfabricated from min 5mm thick M.S. sheet complete as per specification no.FF-FFA/ACT
1709Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg percm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I.pipe, elbow etc. complete as per specification no. FF-FFA/PG
1710Supplying and erecting 12/15 mm dia pressure switch with provided isolationvalve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
1711Supplying and erecting G.I.pipe ‘C’class ERW 200 mm dia with necessaryfittings complete as per specification no. FF-PP
1712Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
1713Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
1714Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type Each flanged end pattern, PN16 pressure rating, SS screen, end connection withFlanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
1715Supplying and erecting 200 mm dia. cast iron double flange sluice valvecomplete with PN16 pressure rating, as per specification no. FF-VL/SV
1716Supplying and erecting 150 mm dia. cast iron double flange sluice valvecomplete with PN16 pressure rating, as per specification no. FF-VL/SV
1717Supplying and erecting 100 mm dia. cast iron double flange sluice valvecomplete with PN16 pressure rating, as per specification no. FF-VL/SV
1718Supplying and erecting 75/80 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
1719Supplying and erecting 50 mm dia. cast iron double flange butterfly valve ofsize complete with PN16 pressure rating, as per specification no. FF-VL/BFV
1720Supplying and erecting 100 mm dia. cast iron double flange butterfly valve ofsize complete with PN16 pressure rating, as per specification no. FF-VL/BFV
1721Supplying and erecting 150 mm dia. cast iron double flange butterfly valve ofsize complete with PN16 pressure rating, as per specification no. FF-VL/BFV
1722Supplying and erecting 75/80 mm dia cast iron double flange NRV completewith PN16 pressure rating, as per specification no. FF-VL/NRV
1723Supplying and erecting 200 mm dia cast iron double flange NRV completewith PN16 pressure rating, as per specification no. FF-VL/NRV
1724Supplying and erecting 150 mm dia cast iron double flange NRV completewith PN16 pressure rating, as per specification no. FF-VL/NRV
1725Supplying and erecting 100 mm dia cast iron double flange NRV completewith PN16 pressure rating, as per specification no. FF-VL/NRV
1726Supplying and erecting stainless steel single outlet hydrant valve fitted withnecessary accessories complete as per specification no. FF-VL/HV
1727Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
1728Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
1729Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrantvalve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.)made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doorswith viewing glass (8\\"x6\\") and locking arrangement with necessary fixingmaterial such as rubber bidding etc. duly painted in post box red colour( Code538 of IS 5)
1730Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mmouter dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
1731Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected withnecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
1732for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....
1733Supplying and erecting 150 mm dia fire brigade header suitable for supplying Each water in fire tank complete as per specification no. FF-FA/FBC
1734Supplying and erecting fire brigade header ( Siamese connection )of 150 mm Each dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC
1735Supplying and erecting 20/25mm dia gun metal air release cock,withEach necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
1736Supplying, erecting, testing & commissioning of fire pump control panel (FCP) Each (New)of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specificationsthe capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 182320 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification.8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP
1737For main electric motor driven fire hydrant system pump of 37kW capacity &relevant capacity jockey pump add Rs….
1738Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C.Submersible/centrifugal pump set up to 7.5 HP- 10 H.P. consisting of DOLstarter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter,phase indicating lamp enclosed in CRCA powder coated Vibration proofenclosure with IP 54 protection. Control Panel should offer single phasing, phasereversal, phase imbalance etc.
1739For addition of standby main diesel engine driven fire pump (1 standby),add as follows in the basic cost of Item no 13-5-1 towards required 12/24 vbattery charger and diesel engine starter along with necessary accessories,indicators etc. with necessary interlocking and updation of control logic withinterlocking for operation of pumps MFP for main (1working+1standby mode)& jockey fire pumps (1working+1standby, alternate run per start in auto mode) ,add Rs.......The control for diesel engine comprises of automatic/manual selector switch & 3attempts starting device, timers and relays as required, push buttons, start/stop inmanual mode indicating lamp for high/ low Lub. oil pressure, high water tempand engine on indication battery charger suitable for 12V/24 V DC with boostand trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter withall standard relays and accessories required for automatic operation of dieselengine with interlocking for operation of main fire pumps.for main & jockey pumps along with necessary accessories for main & jockey firepumps MFP=(1working), JP = (1working + 1standby, alternate run per start inauto mode)
1740Short Description (2)13.3 Booster Pump (FF-MFP/BP)Supplying, installation, testing and commissioning of booster fire pump [BP]suitable for water discharge of 450 LPM at 35 m head driven by electricmotor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kWcapacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of castiron body & bronze/CI impeller with stainless steel shaft (SS410 grade),mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation with IP 55 protection for enclosure, horizontal foot mounted typewith Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pumpset with accessories duly painted with two coats of synthetic enamel paint of firered colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete,as per specification no. FF-MFP/BPSupplying, installation, testing and commissioning of booster fire pump [BP]suitable for water discharge of 900 LPM at 35 m head driven by electricmotor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of castiron body & bronze/CI impeller with stainless steel shaft (SS410 grade),mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation on with IP 55 protection for enclosure, horizontal foot mountedtype with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required.(d)Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/BP
1741Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg percm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I.pipe, elbow etc. complete as per specification no. FF-FFA/PG
1742Supplying and erecting 12/15 mm dia pressure switch with provided isolationvalve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
1743Supplyinganderecting G.I.pipe ‘C’class ERW 100 mm dia with necessaryfittings complete as per specification no. FF-PP
1744Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
1745Supplyinganderecting G.I.pipe ‘C’ class ERW 65mm dia with necessary fittings complete as per specification no. FF-PP
1746Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-typeflanged end pattern, PN16 pressure rating, SS screen, end connection withFlanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (openarea Ratio) for positive suction complete as per specification no. FF-VL/ELS
1747Supplying and erecting 100 mm dia. cast iron double flange sluice valvecomplete with PN16 pressure rating, as per specification no. FF-VL/SV
1748Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valveof size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
1749Supplying and erecting 75/80 mm dia cast iron double flange NRV completewith PN16 pressure rating, as per specification no. FF-VL/NRV
1750Supplyingand erecting stainless steel single outlet hydrant valve fitted withnecessary accessories complete as per specification no. FF-VL/HV
1751Supplying and installing wall mounting swinging hose reel drum fitted with 19mm dia. 30m long high pressure polypropylene (Polyhose) along with necessaryaccessories complete as per specification no. FF-FFA/HV
1752Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
1753Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
1754Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrantvalve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.)made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doorswith viewing glass (8\\"x6\\") and locking arrangement with necessary fixingmaterial such as rubber bidding etc. duly painted in post box red colour( Code538 of IS 5)
1755Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mmouter dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
1756Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected withnecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
1757Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser completeas per specification no. FF-FFA/ARV
1758for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....
1759Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C.Submersible/centrifugal pump set up to 7.5 HP- 10 H.P. consisting of DOLstarter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter,phase indicating lamp enclosed in CRCA powder coated Vibration proofenclosure with IP 54 protection. Control Panel should offer single phasing, phasereversal, phase imbalance etc.
1760Supplying, installation, testing and commissioning of booster fire pump [BP]suitable for water discharge of 900 LPM at 35 m head driven by electricmotor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kWcapacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of castiron body & bronze/CI impeller with stainless steel shaft (SS410 grade),mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation on with IP 55 protection for enclosure, horizontal foot mountedtype with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required.per specification no. FF-MFP/BP(d)Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
1761Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg percm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I.pipe, elbow etc. complete as per specification no. FF-FFA/PG
1762Supplying and erecting 12/15 mm dia pressure switch with provided isolationvalve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
1763Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary m fittings complete as per specification no. FF-PP
1764Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessar fittings complete as per specification no. FF-PP
1765Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
1766Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type Each flanged end pattern, PN16 pressure rating, SS screen, end connection withFlanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
1767Supplying and erecting 100 mm dia. cast iron double flange sluice valve Each complete with PN16 pressure rating, as per specification no. FF-VL/SV
1768Supplying and erecting75/ 80 mm dia. cast iron double flange sluice valve Each complete with PN16 pressure rating, as per specification no. FF-VL/SV
1769Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of Each size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
1770Supplying and erecting 100mm dia. cast iron double flange butterfly valve of Each size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
1771Supplying and erecting 75/80 mm dia cast iron double flange NRV complete Each with PN16 pressure rating, as per specification no. FF-VL/NRV
1772Supplying and erecting stainless steel single outlet hydrant valve fitted withnecessary accessories complete as per specification no. FF-VL/HV
1773Supplying and installing wall mounting swinging hose reel drum fitted with 19mm dia. 30m long high pressure polypropylene (Polyhose) along with necessaryaccessories complete as per specification no. FF-FFA/HV
1774Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
1775Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/NZ
1776Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrantvalve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.)made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doorswith viewing glass (8\\"x6\\") and locking arrangement with necessary fixingmaterial such as rubber bidding etc. duly painted in post box red colour( Code538 of IS 5)
1777Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mmouter dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
1778S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected withnecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
1779For addition of booster pump for fire hydrant/sprinkler, add as follows in thebasic cost of item no 13-5-1 towards necessary accessories, indicators etc. withnecessary interlocking and updation of control logic, add Rs....... -for 11kW centrifugal type booster pump 1no(1working) , add Rs…....
1780Supplying and erecting 20/25mm dia gun metal air release cock, with Each necessary G.I. coupling to be fitted on top of air vessel or on wet riser completeas per specification no. FF-FFA/ARV
1781for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....
1782Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C.Submersible/centrifugal pump set up to 7.5 HP- 10 H.P. consisting of DOLstarter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter,phase indicating lamp enclosed in CRCA powder coated Vibration proofenclosure with IP 54 protection. Control Panel should offer single phasing, phasereversal, phase imbalance etc.
1783Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5- 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
1784Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
1785Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ- ACwith inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
1786Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mmconforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
1787Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF AFAS/SD
1788Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from-20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
1789Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
1790Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
1791Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
1792Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
1793Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
1794Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
1795Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
1796Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50- 16000 Hz suitable to operate in-10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
1797Supplying, erecting, testing and commissioning rust free microphone table stand of chrome plating/powder coating or S.S. material, up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.
1798Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
1799Supplying, erecting, testing and commissioning of 1.0 sq. mm speaker wire complete
1800Supplying and layingHMS PVCconduit FRLS grade 25mmdia with necessaryaccessoriesinRCCwork/falseceiling/falseflooringasperspecification No. WG-MA/CC
1801Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
1802Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 1 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ- ACwith inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
1803Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF AFAS/SD
1804Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from-20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
1805Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
1806Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
1807Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
1808Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
1809Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
1810Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
1811Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
1812Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50- 16000 Hz suitable to operate in-10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
1813Supplying, erecting, testing and commissioning rust free microphone table stand of chrome plating/powder coating or S.S. material, up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.
1814Supplying, erecting, testing and commissioning of 1.0 sq. mm speaker wire complete
1815Supplying and layingHMS PVCconduit FRLS grade 25mmdia with necessary accessories in RCC work/falseceiling/false flooring asper specification No. WG-MA/CC
1816Providing Lift work to the Proposed Building of Girls Hostel At CH. Sambhaji Nagar,dist.CH.Sambhaji Nagar.
1817Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC
1818Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
1819Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
1820Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
1821Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
1822Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
1823Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
1824Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete.
1825Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
1826Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
1827Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
1828Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW
1829Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty.
1830Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
1831Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete.
1832Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
1833Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
1834Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
1835Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1836Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1837Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1838Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
1839Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1840Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1841Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1842Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1843Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1844Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1845Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials testing & recording the results as per specification no ESE -LA [9-1-6] (2EARHING X8LIFT=16NOS)
1846Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
1847SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.
1848ADD ON C For additional 2MP Camera along with necessary accessories at Home Landing add as given. Rs. 13460.00
1849SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with· Rated capacity :- 15 Passenger/1020Kg· Floors :- G+10 floor (11 Stops/11 Landings)· Travel :- 44 to 46 mtrs· Location of Lift Machine:- MR/MRL [applicable for Passenger Liftwith MRL only & Stretcher/Hospital Lift with MR & MRL]· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800/900/1000 mm wide x 2000mmhigh· Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons withBraille code & luminous indicator around button with CPI, Lift car arrival & nexttravel direction audio-visual indication at all landings.
1850· Lift controller of simplex full collective based on microprocessor/ PLC withVVVF Drive having closed loop control system, with IBMS compatible havingnecessary port. The controller shall have necessary Protections such asovercurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc.,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20\\" FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG,electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.
1851· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessaryblocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erectionpermissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) withsubmission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the dateof commissioning.ADD ON For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. 2701900 +152654 * 3 = Rs.3159862/-
1852SITC of Electric Traction Passenger Lift with· Rated capacity :- 13 Passenger/884Kg· Floors :- G+10 floor (11 Stops/11 Landings)· Travel :- 44 to 46 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 900/1000 mm wide x 2000 mmhigh· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.
1853· Lift controller of simplex full collective based on microprocessor/ PLC withVVVF Drive having closed loop control system, with IBMS compatible havingnecessary port. The controller shall have necessary protections such asovercurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20\\" FHD TV monitor, to be kept inFCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.
1854· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection oflanding door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erectionpermissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) withsubmission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.ADD ON A1-4 For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessaryfor the normal safe functioning of lift installation complete. 2461370 + RS. 152654*3 floor= Rs.2919332/-
1855Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC
1856Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
1857Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
1858Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
1859Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
1860Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
1861Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
1862Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete.
1863Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
1864Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
1865Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
1866Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW
1867Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty.
1868Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
1869Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete.
1870Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
1871Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
1872Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
1873Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1874Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1875Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1876Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
1877Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1878Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1879Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1880Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1881Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1882Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1883Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials testing & recording the results as per specification no ESE -LA [9-1-6] (2EARHING X8LIFT=16NOS)
1884Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
1885SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.
1886ADD ON C For additional 2MP Camera along with necessary accessories at Home Landing add as given. Rs. 13460.00
1887SITC of Electric Traction Passenger Lift with· Rated capacity :- 8 Passenger/544Kg· Floors :- G+2 floor (3 Stops/4Landings)· Travel :- 9 to 12.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0 mps VS· · Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.
1888· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.
1889· Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection oflanding door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erectionpermissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) withsubmission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
1890ADD ON For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. (Basic rate Rs. 1087600/-)(RS. 137030.85*1 floor=(137031) 1 lift cost (RS.1087600*1 +137031) =1224631/-
1891Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC
1892Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
1893Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
1894Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
1895Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
1896Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
1897Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
1898Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete.
1899Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
1900Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
1901Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
1902Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW
1903Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty.
1904Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
1905Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete.
1906Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
1907Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
1908Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
1909Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1910Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1911Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1912Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
1913Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1914Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1915Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
1916Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1917Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1918Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1919Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials testing & recording the results as per specification no ESE -LA [9-1-6] (2EARHING X8LIFT=16NOS)
1920Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
1921SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.
1922ADD ON C For additional 2MP Camera along with necessary accessories at Home Landing add as given. Rs. 13460.00
1923SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/680Kg· Floors :- G+1 floor (2 Stops/2 Landings)· Travel :- 3 to 4.2 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.0mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mm high· Clear Car size of ......mm wide x ......mm deep x 2250mm high· Lift shaft available having clear size of ......mm wide x ......mm deep,......mm Pit depth, ………mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code &luminous indicator around button with FPI, scrolling UP/DN LED indicator &with / without attendant key switch, OWD with audio-visual alarm, VAS inMarathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.
1924· Lift controller based on microprocessor/ PLC with VVVF Drive havingclosed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IPbased vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.
1925Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection oflanding door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erectionpermissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) withsubmission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. Add For Full Collective control system, Add Rs 27340/-
1926Providing Transformer room work to the Proposed Building of Girls Hostel At CH. Sambhaji Nagar,dist.CH.Sambhaji Nagar.
1927Supplying and erecting PVC box trunking of size 50x50 mm. withaccessories on wall/ceiling as per specification No: WG-MA/BOX.
1928Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.as per specification No: WG-MA/BW
1929Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1930Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1931Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB
1932Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB
1933Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
1934Supplying, installing, testing and commissioning air circuit breaker manual drawout type, 650V, 1000A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close indication, individual fault trip indication, indications for alarm and trip, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB
1935Supplying & erecting 415V, 100A porcelain base neutral link complete erected in provided M.S. box.
1936Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A
1937Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8)
1938Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8)
1939Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
1940Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB.
1941Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and dulypowder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
1942Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
1943Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
1944Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB
1945Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panel mounting to measures and display parameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I, kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software
1946Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
1947Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
1948Supplying, installation & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for single phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
1949Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
1950Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
1951Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT
1952Supplying, erecting, testing and commissioning 11KV HT metering cubical(compact / vertical type) approved by MSEDCL / licensee fabricated with 2mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating /epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening ofmeter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.
1953Supplying, installing, testing and commissioning 11 kV 630A, indoor type ring main unit with 1 VCB & 2 LBS with internal arc compliance complete erected on provided CC foundation/MS channels/trench, etc., as per specification no SW-HTS / RMU
1954Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP
1955Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
1956Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 630 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , withstandard accessories complete with test certificate with losses below 1860 Watts at 50% load, 5300 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL.
1957Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plasteredby 12 mm thick including watering etc complete.
1958Painting fencing of transformer substation including all supports, iron work and doors from both sides by scrapping existing paint, with one coat of red oxide & two coats of aluminium paint complete.
1959Providing HVAC work to the Proposed Building of Girls Hostel At CH. Sambhaji Nagar,dist.CH.Sambhaji Nagar.
1960M.S Sheet Metal DuctingSupply, fabrication, installation and testing of Kitchen duct with 2Hr Fire Coating & Insulation16 gauge MS duct work welded construction. Duct shall have fire rated coating compound. Fire rated coating compound used for construction of fire rated duct work shall be protected with minimum 0.7mm to 1mm nominal thickness tested to properties as per the requirements of BS 476: 6 & amp; 7, including non-combustibility Class O and fire propagation - Class 1 surface spread of flame & amp; materials in accordance with building regulations. The duct construction & installation to be done as per NFPA 96 duct installation standards (8.0 & 8.1) with minimum slope and cleanout doors at specified distance. Flanges to be considered accordingly. The cost should be with MS structural work required for duct mounting. The supporting work to be considered for upto 1m supports. Fire Coating with Fire retardant paint/coat for ductwork. The coat shall be 60min fire rated when tested in accordance with BS 476: Part 21: 1987. work shall be carried out with necessary precautions recommended by paint manufacturer. ( To be applied for All kitchen area ducts)Ceramic fibre wool insulation (Suitable for high temperature applications) with 25mm thickness and 26 AL cladding for Kitchen exhaust duct.
1961Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.
1962SITC of Ecology Unit for Kitchen Exhaust The Ecology Unit must have double skin construction with self contained unit having UL762 listed Mixed flow inline fan with external motor mount with canopy and Electrostatic Precipitator unit. The unit shall be suitable for Kitchen exhaust applications & use at outdoor application. Total scrubber efficiency should be 90% to 95% as per ASHRAE 52.2 at 1 Micron particle operation. Casing Should be minimum 25mm thick with 0.6 mm inner & outer precoated GI sheet , casing constructed of extreded AL profile , heavy guage GI Base. Fan shall be UL 762 & AMCA certified for 400 Deg, F Electrostatic Precipitator Must Be CE Certified. Performnce Data Submitted Must Be For Complete Esp Unit With Prefilter,Ionizer,Collector Section.Only Cell Performce Data Without Prefilter Is Not Accepatable , Made Of Minimum Of 1.5mm Galvanized Sheet, With Reinforced Structure And High Bake Epoxy Powder Coated To Protect Against Rust And Corrosion. Built-In Large Capacity Oil Drain-Pan And Drain Outlet From Side Only, Bottom Drain Not Allowed. All Doors Shall Be Gasketed To Prevent Air And Water Leakage. The cost should be inclusive of IP55 rated BMS compatible Starter Panel and avg. 10 Rmt Power Cabelling with terminations.
1963ECOLOGY suitable for 9000 CFM (Multiple cells) Fan ESP - 75mm
1964Supply, Installation, Testing & Commissioning of Tubular Mixed flow fans suitble for Kitchen Fresh Air application complete blades with aerofoil design, bird screen, flexible connection .Fan should be belt driven with external housing for Motor. Motor shall be of 415 + 10% volts, 50 Hz.Fan motor should have minimum efficiency of IE3 level The Motor shall be VFD compatible. Sound level at 3mt distance from fan outlet shall not be more than 80 db.(A) (Room Condition). Capacity shall be as follows & as per detailed technical specification: Fans should be AMCA certified for AIR & Sound. IP 55 rated BMS compatible starter panel along with 7 meter power cable to be considered in cost with remote on-off provision. The panel should have provision to start/stop the fan based on remote push button signal as well as on FA signal. The panel should be able to indicate status & generate alarm on BMS in case of failure. Cost of flexible connections to be considered. The Fan should be suitable for outdoor installations ( canopy to be considered for Motor). Final ESP will be as per Calculations based on approved shop drawing. The Fan should be suitable for Floor Mounted / Ceiling Mounted installation as asked in tender drawings.
19657200 CFM at 40 mm static pressure- Kitchen
1966Supply, Installation, Testing and Commissioning of Electrostatic Grease Removal Scrubber for Kitchen ,scrubber are to be with IP65 along with starterpanel, power cable.
1967Supply, installation, testing and commissioning of volume control box with collar for control damper of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
1968Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56445967
AUTHORITY Government Departments
TENDER VALUE 86.47 Crore
LAST DATE 28-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Girls Govt Hostel Building & Residential Quarters At Pad Ura Chhatrapati Sambhaji Nagar, Dist.Chhatrapati Sambhaji Nagar (Capacity 1000)
Basic Detail
Tender No E TENDER NOTICE NO 10 FOR 2026-2027
Bidding Type Tender
Location
City Aurangabad
State Maharashtra
Key Dates
Publish Date 13 Jul 2026
Submission Date 28 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 86.47 Crore
Tender Fee 3540
EMD 43.24 Lakhs
Exemption Not Available
Document List
92831486-f99e-4940-b99b-488b3c4117b9.html
BOQ_2258441.xls
HOSTEL1000GIRLSB2TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

92831486-f99e-4940-b99b-488b3c4117b9.html

xls

BOQ_2258441.xls

pdf

HOSTEL1000GIRLSB2TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders