Water Resources and Irrigation Government Departments Closing in 7 days TDR #56444020

Tender For Upgradation Of Pump Station At Markoot Gurez Of Misd Hajin.

Issued by Government Departments · Ganderbal, Jammu and Kashmir
Tender Value
17.34 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
7 days left
EMD
35000
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganderbal → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Upgradation Of Pump Station At Markoot Gurez Of Misd Hajin.

BOQ

Name of Work:- Upgradation of Pump Station at Markoot Gurez of MISD Hajin.
Sl. No. Item Description
1Design, Manufacture, Supply, Installation, Testing and Commissioning of 03 Cusec Capacity Horizontal Pump with 15 Meter Dynamic Head Coupled to 35 HP Horizontal Sq. Cage Induction Motor through a suitable size coupling along with base frame and foundation bolts as per the design. One unit operational and another one being proposed is a Standby Unit(NPSHA-3.70 Meters)The job includes fitment of already available Suction and Delivery pipes of existing/old Diesel Driven Unit with the new Pump Motor Assembly after proper alignment, welding and cutting jobs including fitment of increaser/reducer/flanges during installation process.
2Fabrication, providing, fitting of MS foundation bolts T type at the bottom. The bolts shall be fabricated out of 20 mm thick MS round bars and 900 mm long bar. The T piece shall be 150 mm long and shall be welded. The bolts shall be threaded up to 75 mm at the top. Each bolt shall be fitted with nuts and washers of required size. The bolts shall be grouted in the above cement concrete block for fixing of the base frame of the pumping unit.
3Supply, Installation and Testing of Priming pump of following specifications:a. Type ------ Monoblockb. Size ------ 80mm x 65 mm c. Head range ------ 15 – 24 Mtrs.d. Phase, voltage ------ 3 phase 415+/-10% Ve. Discharge ------ 9 – 12 LPS or higherf. Power ------ 05 HPg. Speed ------ 3000 RPM (synchronous)The Job shall include providing/ fitting of all G.I Pipe 80 mm NB C-class (Approx. =20 Rft.), GI pipe 65mm C-class 40ft and fittings like ball valves, Nipples, flanges/sockets, Tees, Elbows/Bends, CI foot valve & other allied fittings as required for installation of the Priming Unit. The job also includes p/f of 7.5HP DOL Starter along with 4.0 Sq. mm cable 30 Mtrs length approx.
4Providing, Installation, Testing and Commissioning of Auto Transformer Starter (ATS) Panel suitable for operation of 02 Nos. 35 HP, 415 V, 3 Phase, 50 Hz Squirrel Cage Induction Motors.The panel shall consist of two independent Auto Transformer Starters housed in a common floor-mounted CRCA sheet steel cubicle enclosure, enabling:•⁠⁠Independent operation of either Pump No. 1 or Pump No. 2.•⁠⁠Simultaneous operation of both pumps during peak irrigation demand.•⁠⁠Auto Transformer starting with automatic transition to full line voltage.•⁠⁠Auto/Manual operation.•⁠⁠Independent protection for each motor.Technical SpecificationsMotor Rating•⁠⁠Quantity: 02 Nos. •⁠⁠Rating: 20 HP each •⁠⁠Voltage: 415 V ±10% •⁠⁠Frequency: 50 Hz •⁠⁠Phase: Three Phase Full load current approx. 30-35 A per motorStarter Type•⁠⁠Auto Transformer Starter with 65–80% tapping. •⁠⁠Automatic transition using timer.Panel Construction•⁠⁠Floor-mounted, free-standing CRCA sheet steel enclosure. Minimum 14 SWG thickness •⁠⁠Powder-coated finish. •⁠⁠Protection class: IP54.Incoming•⁠⁠1 No. 125 A, 4 Pole MCCB. •⁠⁠Breaking capacity: 36 kA. •⁠⁠Copper busbars of suitable rating.For Each Starter•⁠⁠Auto Transformer of suitable kVA rating. •⁠⁠Three AC-3 duty contactors (Start, Run and Transition). •⁠⁠Timer for automatic changeover. •⁠⁠Thermal overload relay. •⁠⁠Single phasing preventer.•⁠⁠Phase sequence relay. •⁠⁠Under/Over Voltage protection. •⁠⁠Push buttons (Start/Stop).•⁠⁠Auto/Manual selector switch. •⁠⁠Ammeter with selector switchMetering•⁠⁠Digital Voltmeter with selector switch. •⁠⁠Digital Ammeter for each motor. •⁠⁠R-Y-B indication lamps. •⁠⁠ON/TRIP indication lamps.OperationThe panel shall permit: •⁠⁠Operation of Pump No. 1 only. •⁠⁠Operation of Pump No. 2 only. •⁠⁠Simultaneous operation of both pumps whenever required during peak irrigation demand.
5MCCB•⁠⁠Type: Thermal Magnetic MCCB•⁠⁠Poles: 4 Pole•⁠⁠Voltage: 415 V AC•⁠⁠Frequency: 50 HzCurrent RatingThe actual frame size:•⁠⁠200 AF•⁠⁠Adjustable setting 125–200 ABreaking Capacity•⁠⁠Icu = 36 kA•⁠⁠Ics = 100% IcuAccessories•⁠⁠Adjustable thermal setting•⁠⁠Adjustable magnetic trip•⁠⁠Auxiliary contacts•⁠⁠Shunt trip (if required)•⁠⁠Rotary operating handle•⁠⁠Terminal shroudsStandards•⁠⁠IS/IEC 60947-2 compliant
6Providing/supply /installation /testing at site PVC insulated copper cable single core. The cable shall be of size 25 mm Square. The cable shall have to be installed for the internal connecting gadgets like stabilizer, panels, starter inside pump house. The job includes providing and fitting of adequate size/ capacity copper thimbles of reputed make & crippling of the terminal ends of the cable with hydraulic tool
7Providing and fitting of XLPE insulated 1100V 3.5-core (135 mm Square) industrial unarmoured aluminium cable of reputed Make to be used for Main Service Line
8Manufacture, Supply, Installation, testing & commissioning at site 100 KVA Capacity Copper wound voltage stabilizer. (To be used for simultaneous operation of both units during peak irrigation season)The stabilizer shall be manually operated, oil cooled suitable for working on 3 phases 50+ 3% HZ AC voltage. The core shall be contained in a box type container made out of 2 mm thick Mild Steel plate. The container shall be painted in two coats of steel primer both inside and outside and with two coats of super enamel paint of grey shade (Spray paint) from outside the tank. The box shall be provided with suitable cooling pipes to dissipate the heat generated. Hooks of proper size for lifting stabilizer shall be provided on the top of the tank. The container of the stabilizer shall be mounted on wheels for easy shifting/positioning as and when required. Copper strips of suitable size shall be used for winding and fiber glass insulating material shall be used for insulating of copper strips. The core of the stabilizer shall be fabricated out of first class silicon 92 gradesheets cut to the size and then tightened securely. The stabilizer shall have suitable insulated lugs of appropriate size of cable connection. i) The indicating glass of the transformer oil shall also be provided on the transformer body. ii) Voltage Range=Input = 240-500 volts iii) Output = 400/440 voltsiv) Tape Changer=Manually operated balance tapings with tape position Indicator. Tape No: - 1 = Step down by not more than 50 volts. Tape No: - 2 = line voltage Tape No: - 3-6 =These tapes shall be used for increase voltage in the range of 240-440 volts to 400-440 volts The stabilizer shall be provide with a free standing type control panel made out of sheet metal dust and vermin proof internally wired having following accessories.a). Two number voltmeter 100mm square dial flush pattern type 0-500 volts, one each on incoming and outgoing circuits. The voltmeter shall be with fuse and selector switch for 3 phase.b). A set of indicating lamps for 3 phase complete with fusing both in primary and secondary side of the transformer.c). Red and green lamps for OFF/On display. The stabilizer shall be filled with transformer oil for reputed make upto the required level. All the accessories and meters shall be of reputed makes and shall confirm to relevant ISI standards.
9Tool Kit Complete for Mechanics including sockets with socket rods, Spanners, Pipe Wrenches (Small/Medium/Large size), Screw Driver, Hammer and Chisels.
10Providing and fitting of 04 no. Water proof 50 Watt LED Flood lights with complete wiring and switch/control for switching On/Off as per the requirement. Light Installation will safeguard the pumping house equipment and will provide a good security against pilferage/theft during night hours
11Electrification of pump house by way of fabrication of Lighting distribution board of approx. size 2'x 2' fixed on wall by angle iron (ISA40X40X4) and ply board - 12 mm thick with sun mica covering) for installation of MCB, changeover, cu wire (1 -2.5 Sq mm) and allied items requisite for the lighting inside the pump house (LED lamps, switches, sockets, etc.) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56444020
AUTHORITY Government Departments
TENDER VALUE 17.34 Lakhs
LAST DATE 03-08-2026
Authority
Authority Name Irrigation And Flood Control Department
Work Description Tender for Upgradation Of Pump Station At Markoot Gurez Of Misd Hajin.
Basic Detail
Tender No e-NIT No.07 of 2026-27
Bidding Type Tender
Location
City Ganderbal
State Jammu and Kashmir
Key Dates
Publish Date 13 Jul 2026
Submission Date 03 Aug 2026
Open Date 04 Aug 2026
Finance
Tender Value 17.34 Lakhs
Tender Fee 800
EMD 35000
Exemption Available
Document List
BOQ_1026504.xls
c995cdf9-8665-472f-9daa-495e76c0434c.html
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1026504.xls

html

c995cdf9-8665-472f-9daa-495e76c0434c.html

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders