Tender For 1) maintenance of electrical installation & Fans And repair maintenance Pump Sets, Ac Equipment, Dg Set Installed At Cpo Building, Kashmere Gate, Delhi. 2) maintenance of electrical installation & Fans And repair maintenance Pump Sets, Ac
Tender Overview
Project Description
Tender for 1) maintenance of electrical installation & Fans And repair maintenance Pump Sets, Ac Equipment, Dg Set Installed At Cpo Building, Kashmere Gate, Delhi. 2) maintenance of electrical installation & Fans And repair maintenance Pump Sets, Ac Equipment Installed At Sub-Registrar Office, Kashmere Gate, Delhi. 3) maintenance of electrical installation & Fans, Compound Light And repair maintenance Pump Sets, Dg Set & Ac Equipments Installed At Chief Electrol Officer Office, Kashmere Gate, Delhi. 4) maintenance of electrical installation & Fans And Compound Lights Installed At 5 Nos Of Army And Naval Ncc Units, Kashmere Gate, Delhi. 5) maintenance of electrical installation & Fans, Compound Light And repair maintenance Air Conditioner Equipments Including Heating System Installed At Sbp Iti, Mori Gate, Delhi. 6) maintenance of electrical installation & Fans Compound Light/Security Light And Dg Set Installed In Glns & Ohb At Firoz Shah Kolta, Delhi. 7) maintenance of electrical installation & Fans, Compound Light And repair maintenance Drinking Water Supply Pump Set, Air Conditioner Equipments Including Heating System Installed At Diet, Ansari Road, Daryaganj, New Delhi. (Sh:- Miscellaneous electrical installation Works & Other Electrical Accessories)
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group C |
| 2 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/ recessed steel conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | (c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.(a) Group C |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. |
| 7 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(a) 3 Module (100mmX75mm) |
| 8 | (b) 6 Module (200 mmX75 mm) |
| 9 | (c) 12 Module (200 mmX150 mm) |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 5/6 A switch |
| 11 | (b) 15/16 A switch |
| 12 | (c) 3 pin 5/6 A socket outlet |
| 13 | (d) 6 pin 15/16 A socket outlet |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single Pole |
| 15 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.8.1) 20 mm |
| 16 | 8.2) 25 mm |
| 17 | Supplying, Installation, Testing and Commissioning of 450 mm, 1400 RPM Sweep Metal body industrial type (Turbo force) wall Fan for sub station and HT LT Room area, suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required. |
| 18 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted 275 DELHI SCHEDULE OF RATES (E&M)-2025 Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA 568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius :< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. Complete as required.a) 1 Run of cable |
| 19 | b) 2 Run of cable |
| 20 | Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 21 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 22 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required |
| 23 | Supplying, Installation, Testing and Commissioning of 300 mm Sweep 1400 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etcas required. |
| 24 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 25 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.a) 100 A, 16 kA,TPMCCB |
| 26 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness >0.50 mm)17.1) 18-22 watt |
| 27 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness >0.50 mm) (a) 36 watt |
| 28 | Supplying, laying and fixing of following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable of 1.1 KV grade on surface etc complete as required.a) 3 X 10 Sq.mm |
| 29 | b) 3.5 X 25 Sq.mm |
| 30 | c) 3.5 X 35 Sq.mm |
| 31 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.a) 100 mm width X 50 mm depth X 1.6 mm thickness |
| 32 | b) 150 mm width X 50 mm depth X 1.6 mm thickness |
| 33 | Fabrication, supplying & fixing of wiremesh protection frame work fabricating with 40 x 40 x 6 mm thick M.S. angle iron & T iron of 40 x 40 x 6mm thick i/c providing & fixing wiremesh of section 75mm x 25mm of 8 SWG shall have the legs of angle iron of size 40 x 40 x 6mm of length 15cm and is to be grouted in cement concrete (1:2:4) foundation. The frame with having one side door is to be fixed around the various electrical & mechanical equipment & appliances with interlocking arrangement & all frame is to be painted with two coats of red oxide, primer and two coats of synthetic enamel paint of approved colour& quality etc. as required. |
| 34 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 35 | Supplying, installation, testing & commissioning of 60 watt insect killer having 2 x 20 watt lamps made out of stainless steel, suitable for pest control for flies, insects, mosquitoes in covering area of 700800 sq.ft. with protection grill etc. complete as reqd. |
| 36 | Earthing with G. I. earth pipe 4. 5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 37 | Providing and laying earth connection from earth electrode with 6 SWG dia G. I. Wire in 15 mm dia G. I. pipe from earth electrode including connection with G. I. thimble excavation and re-filling as required. |
| 38 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0. 9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1. 5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 26.01) 1200mm, service value = 6. 0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 39 | Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cut off and 50 hz, 1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R410A /R-407B Green Refrigerant with Scroll/ rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P &labour etc. as required complete in all respect as specified of following capacity. Sound level of up to50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate upto 50 Degree C (out door ambient temperature). Inverter Type (a) 1.5 TR with fixed speed 5 Star BEE rating |
| 40 | SITC of storage water cooler cum purifier 150/150/100 ltrs capacity (150 ltrs Storage, 150 Ltrs cooling and 100 ltrs per hr purification) with inbuilt RO + UV having 7-8 stages Ultra Violet based purification system suitable for operation on 220V AC 50 Hz with power consumption 1380 watt + 10% providing water outlet temperature at 17°C at the flow of 150 LPH having permeate production capacity of 100 LPH with autoflush at every one hour for one minute for effectively preventing post microbial contamination in the storage tank inlet and outer body dimension 787x600x1422mm and storage tank of 150 Litre with PUF thermal insulation. Compressor make should be of Kirloskar/Emerson/ Tecumseh and Refrigerant should be of R134A (Eco Friendly) and No of Faucets should be 3 Nos (2 Nos for cold water and 1 No for Normal/Hot Purified water minimum input pressure of 0.4 KG/cmsq and maximum input pressure of 2.0 Kg/Cmsq). The storage tank and outer body material should be of SS304 only. |
| 41 | Supplying and Fixing of 20'' Heavy Duty Prefilter Assembly complete with filter and accessories for protection of membrane from heavy particles i.e. dust etc in existing water cooler and making functional in all respect and testing etc as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender