Agriculture Boards / Undertakings / PSU Closing in 0 days TDR #56440324

Tender For Fci Smart Warehouse Electrical Infrastructure Project For Installation Of Power Sockets For Ai & Sensor Integration - At Fsd Keonjhar And Fsd Dhenkanal For Fy 2026-27.

Issued by Boards / Undertakings / PSU · Dhenkanal, Odisha
Tender Value
9.26 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
0 days left
EMD
18533
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhenkanal → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Fci Smart Warehouse Electrical Infrastructure Project For Installation Of Power Sockets For Ai & Sensor Integration - At Fsd Keonjhar And Fsd Dhenkanal For Fy 2026-27.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 13-Jul-2026 CORRIGENDUM for MSE Other 23-Jul-2026

BOQ

Name of Work:- FCI Smart Warehouse Electrical Infrastructure Project for Installation of Power Sockets for AI & Sensor Integration – at FSD Keonjhar and FSD Dhenkanal for FY 2026-27.
Sl. No. Item Description
1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required
2(a) 4 Module (125mmX75mm)
3(b) 8 Module (125mmX125mm)
4(c) 12 Module (200mmX150mm)
5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6(a) 5/6 A switch
7(b) 3 pin 5/6 A socket outlet
8(c) 15/16 A switch
9(d) 6 pin 15/16 A socket outlet
10Supplying of aluminium conductor PVC insulated, PVC sheathed/ XLPE insulated inner sheathed steel strip armoured power cable of 1.1 KV grade conforming to IS:7098(Part-I) 1988 or latest amended following sizes etc .
11(a) 3X6 sqmm armoured
12Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle)
13Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
14(a) 3x6 sq mm (19 mm)
15Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
16(a) 20 mm
17(b) 25 mm
18(c) 32 mm
19Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
20(a) 3 x 1.5 sq. mm
21(b) 6 x 1.5 sq. mm
22(c) 3 x 2.5 sq. mm
23(d) 6 x 2.5 sq. mm
24Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
25Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
26(A) 8 way , Double door
27Supplying and fixing FP sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required.
28Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
29(A) Single pole
30(B) Single pole and neutral
31Supplying and fixing Type 2 AC Surge Protection Device (SP+N) with Voltage protection level Up upto 1.3 kV having Both Common & Differential Mode Protection in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. (a)150 mm X 150 mm X 60 mm deep
33Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
34Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
35Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56440324
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 9.26 Lakhs
LAST DATE 23-07-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Fci Smart Warehouse Electrical Infrastructure Project For Installation Of Power Sockets For Ai & Sensor Integration - At Fsd Keonjhar And Fsd Dhenkanal For Fy 2026-27.
Basic Detail
Tender No EM/Engg./2026-27/03
Bidding Type Tender
Location
City Dhenkanal
State Odisha
Key Dates
Publish Date 13 Jul 2026
Submission Date 23 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 9.26 Lakhs
Tender Fee Ref. Documents
EMD 18533
Exemption Not Available
Document List
b1d7138a-9b21-4f13-96c0-9c6b730d476c.html
BOQ_963801.xls
MTF.pdf
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
html

b1d7138a-9b21-4f13-96c0-9c6b730d476c.html

xls

BOQ_963801.xls

pdf

MTF.pdf

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders