Tender For repair maintenance Electrical & Mechanical Various Services At Children Home Alipur During 2026-27 ( Sh:- Maintenance Of electrical installation & Fans, Street Lights And Operation Of Pumpsets, Dg Sets, R.O. Plant And 11 Kv / 440 Volt Subs
Tender Overview
Project Description
Tender for repair maintenance Electrical & Mechanical Various Services At Children Home Alipur During 2026-27 ( Sh:- Maintenance Of electrical installation & Fans, Street Lights And Operation Of Pumpsets, Dg Sets, R.O. Plant And 11 Kv / 440 Volt Substation Etc.).
BOQ
| Sl. No. | Item Description |
| 1 | SH:- I (Maintenance & Operation)Providing services for day to day maintenance, upkeep & operation of Internal Electrical Installaion, Compound Lights /Flood Lights & water supply Pump, DG Set, RO plant, CCTV (Inventory & staff details as per annexure-A) at Children Home Alipur on all working days including sunday and holidays or as per directions of Engineer-in-charge, terms and conditions etc. as reqd.Wireman cum Operator-3 NosKhallasi-1 No. |
| 2 | SH:- II (EI Work)Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 6 | 3 x 4 sq. mm |
| 7 | 6 x 4 sq. mm |
| 8 | 3 x 6 sq. mm |
| 9 | Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 10 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 12 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 13 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 14 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 15 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 16 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 17 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required. |
| 18 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 19 | Above 35 sq. mm and upto 95 sq. mm |
| 20 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE insulated power cable of 1.1 kV grade of following size on wall surface, including necessary clamps, wooden/metal saddles, nails, bolts, nuts, etc. as required and making good the surface if damage, complete with connections, testing and commissioning as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 21 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 22 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 23 | Supplying of one number XLPE insulated and PVC sheathed aluminium conductor, armoured underground power cable of 1.1 KV grade of following size and in following manner on wall / surface as required.4 x16 sq.mm |
| 24 | 4 x 25 sq.mm |
| 25 | SH-III (Rewinding and Reapir)Repairing of all type of damage pumps (of water supply/sewage etc. pump sets) i/c dismantling from site, shifting to workshop, turning & polishing of shaft, replacement of GM bearing bush, ball bearing, O ring, thrust bush, thrust plate etc. all items/parts i/c buy back of dismantle material to contractor (dismantle material shall retained with agency) i/c trasfer from workshop to site of work including reassembled, isnatllation, testing and commissioning etc complete as required at site.a) 3 HP pump motor sets (all types) |
| 26 | b) 5 HP pump motor sets (all types) |
| 27 | Dismantling of exisitng motor pump sets, transfer to workshop from site, rewinding of motor with super enameled copper wire including inspection of motor suspension arrangement and tightness of nuts and bolts, cotter pin, rubber reel and replacement of the same wherever found defective during inspection for safe running of motor i/c cleaning the motor with detergent i/c less for old dismantle complete etc as required icluding reassemble, transfer to site of work including installation, testing and commissioning etc. complete as required at site.a) 3 HP pump motor sets (all types) |
| 28 | b) 5 HP pump motor sets (all types) |
| 29 | Lifting of existing submersible bore well / open well Pump set from the bore well with chain pulley block & tripod stand i/c cartage charge at site from the work shop. |
| 30 | Lowering of bore well/open well pumpset in the bore well with chain pulley block and tripod stand i/c cartage charge pump set from work shop to site credit of old dismantle etc, as reqd. |
| 31 | Supplying, Lowering of G.I Pipe 50mm dia medium class having length of 3 mtr. Each length having threading on both ends i/c 2 nos flanges welded at each ends, gasket, nut, bolts etc complete as reqd. |
| 32 | Supplying & fixing of 3 core 4 sq.mm flat water proof copper conductor submersible cable i/c water proof joint, connection for submersible pumpset etc. complete as reqd. |
| 33 | SH-IV( Sub-Station)Servicing of dry type transformer 500 KVA capacity including tightening Nut, Bolts, cleaning the transformer and removing dust i/c testing of IR value, Voltage Ratio, Magnetic Current, Magnetic Voltage, Magnetic balance, complete as required checking the contacts routine half yearly yearly check-up as per manufacturer recommendations. |
| 34 | Servicing of 11KV 630 amps. 3 phase 50 Hz Vaccum Circuit Breaker i/c drawing out the VCB, cleaning of components, decarbonising of the arcing chamber, setting right the mechanism, lubricating the moving parts, checking & testing the continuity of control wiring, tightening of connections, of moving & fixed contacts, replacement of minor worn out parts like nut bolts & spring washer etc., reinstallation, testing etc. complete as reqd. |
| 35 | Testing & calibration of micro processor controlled relay of HT panel routine test etc. as reqd. with the help of relay testing machine etc as required.(a) O/C relay-2 nos.(b) Earth fault relay-1 no.(c) Master relay -1 no.(d) Trip circuit supervision relay -1 no. |
| 36 | Servicing of 800-1250 amps. 3 phase 50 Hz Air circuit breaker i/c drawing out the ACB, cleaning of components, decarbonising of the arcing chamber, setting right the mechanism, lubricating the moving parts, checking & testing the continuity of control wiring, tightening of connections, of moving & fixed contacts, replacement of minor worn out parts like nut bolts & spring washer etc., reinstallation, testing etc. complete as reqd. |
| 37 | SH-V( DG Set)Servicing of 125 KVA DG Set i/c following accessories for DG Sets for 'B' Check etc. complete as required.FILTER,FUEL 3931063CARTRIDGE,LUB OIL FILTER 3937743ELEMENT,AIR CLEANER 3814695ELEMENT,AIR CLEANER 3814696PREMIXED COOLANT PETRONAS URANIA 1000 CH-4 20 Ltr. |
| 38 | Dismentaaling , external and intrenal descaling Radiator of existing DG set with hot water and acid solution of appopriate Conectration and neutralize it with alkaline solution to make radiator scale free for proper cooling of engine i/c reinstalltion testing commissioning of radiotor complete etc as required.125 KVA DG set |
| 39 | Preventive/Periodical maintenance of following capacity, make/model Existing Diesel Engine Set (Engine & alternator, DG set charger, battery and all parts) with AMF panels etc including preventive Daily/monthly/annually maintenance and submit monthly report of complete testing by OEM/Authorised representative, maintain all mechanical, Electrical & Electronic Parts includingrepair/replacement of minor parts as per mentioned terms and condition as and when required complete in all respect etc. to keep the DG set functional all time and attend the DG set on breakdown to remove fault etc as required.. (Anual maintenance shall be considere after 1st 'B' Check servicing as mentioned in item no 29 & 30)125KVA DG Set at childern Home Alipur |
| 40 | SH-VI(RO)Comprehensive maintenance of following LPH R.O. Plants i/c supplying and replacement of all defective parts (except filters and membrane) inluding raw water pump-moter, high pressure pump-motors, dosing pump-motors etc. complete all parts of system, providing chlorine and other consumable items each month as required, etc complete as required and submit monthly test report and maintain desired TDS and other parameters.3000 LPH |
| 41 | Supplying and dosing of anti scalent chemical in plant regularly with operation of RO plant suitable for mote than 1500 TDS water etc. as required. |
| 42 | Supplying replacement of TFC Membrane of size 80\\"X40\\" at existing RO Plant i/c testing, commssioning complete etc as required. |
| 43 | Providing and replacment micron cartidge micron fillter of size 20\\" long & 4\\" dia filtering upto 5 micron suspended particles at existing RO system i/c testing commissioning complete as required. |
| 44 | SH:- VII (Supply of materials)Note:- No labour is considered for fixing of these itemsS.P. 5/6 A, one way modular switch, ISI marked |
| 45 | S.P. 15/16 A, one way modular switch, ISI marked |
| 46 | 3 pin 5/6 A modular socket outlet, ISI marked |
| 47 | 6 pin 15/16 A modular socket outlet, ISI marked |
| 48 | Stepped type Modular Fan regulator (2 module) |
| 49 | Modular base & cover plate for 8 module |
| 50 | Modular base & cover plate for 12 module |
| 51 | 6 A, to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 52 | 12-15 Watt LED recessed/surface down lighter (Round/Square /Rectangular) SMD Type (System lumen efficacy ≥ 105 < 120 lm/Watt ), Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector complete etc as reqd. |
| 53 | 1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req |
| 54 | 3 pole MCCB, 125A, 16kA Ics=100% Icu and Operational Voltage 690V |
| 55 | 3 pole MCCB, 250A, 25kA Ics=100% Icu and Operational Voltage 690V |
| 56 | 3 pole MCCB, 315A, 35kA Ics=100% Icu and Operational Voltage 690V |
| 57 | 40 Amp DP MCB 10 kA rating \\"C\\" Curve |
| 58 | 63 Amp 4P MCB 10 kA rating \\"C\\" Curve |
| 59 | 100 Amp 4P MCB 10 kA rating \\"C\\" Curve |
| 60 | 300 mm sweep 900 RPM, exhaust fan |
| 61 | 25 Ltr.capacity (5 Star Rated) Geyser with anti Corrosion protection and suitable for working on up 8 bar water pressure . |
| 62 | SH:- VIII (Credit of old dismantle materials)Less credit for Old dismantle/unserviceable material with following quantity:-GI Box i/c Cover Plate |
| 63 | Copper wire assorted size cut piece |
| 64 | Al conductor power cable all size assorted size |
| 65 | MCCB of various capacity |
| 66 | 3/4 Pole MCB of various capacity |
| 67 | Ceiling Fan |
| 68 | LED fittings (Batten, Downlighter) |
| 69 | Exhaust fan |
| 70 | Geyser |
| 71 | Switch, Socket |
| 72 | SP MCB Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender