Tender For maintenance of electrical installation And Fans, Compound Lights, repair maintenance Pump Sets & Maintenance Of Air Conditioners, Lifts, Dg Set, Ro Unit, Water Coolers, Stp Plant And Other E & M Services At Rajokari Institute Of Technology

Issued by Government Departments · New Delhi, Delhi
Tender Value
18.25 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
1 days left
EMD
36507
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance of electrical installation And Fans, Compound Lights, repair maintenance Pump Sets & Maintenance Of Air Conditioners, Lifts, Dg Set, Ro Unit, Water Coolers, Stp Plant And Other E & M Services At Rajokari Institute Of Technology, Rajokari Under Emd South West During 2026-27. (Sh : electrical installation Work, Maintenance Of Air Conditioner & Pump Etc.).

BOQ

Name of Work:- MOEI and fans, compound lights, RMO pump sets & maintenance of Air Conditioners, Lifts, DG set, RO unit, water Coolers, STP Plant and other E & M services at Rajokari Institute of Technology, Rajokari under EMD South West during 2026-27. (SH : EI work, maintenance of Air Conditioner & pump etc.).
Sl. No. Item Description
1Sub-Head-1(Maintenance of EI)Maintenance of light points, fan points, exhaust fan point, call bell point, light plugs, power plugs, circuit wiring, street light and flood light i/c DBs main boards and other electrical installation in the building during the month except Sundays & Holidays by providing following staff and as per terms & conditions attached:Staffs:
2Wireman - 1 No. (General Shift) (8 AM to 4 PM)
3Khallasi- 1 No. (General Shift) (8 AM to 4 PM)
4SH-II ( Maintenance of Air Conditioners)Comprehensive & Routine maintenance of 2.0/2.5/3.0 TR Cassate type AC unit i/c attending day to day complaints from 8 AM to 4 PM and rectify the defects, supplying and replacement of wornout parts such as starting / running capacitors, starting relays, overload relay, tharmostat, selector switches, sleeves, knobes, connector etc which reqd to be replace during routine maintenance and monthly cleaning of filters etc. (Replacement of compressor, condensor unit, cooling coil unit, blower, fan blower motor, front grill, man leads, gas charging etc not covered under routine maintenance) complete as per terms & conditons and Engineer-in-Charge. (17 Nos. Machine for 6 Month)
5Supplying & replacement of 2.5 / 3.0 TR capacity compressor in the existing outdoor unit Cassette type AC unit i/c making connection testing commission etc complete as required. (Dismantle Material Retained by contractor)
6Leakage repairing, making copper pipe connection, , N2 pressure testing and vacuming of cassette unit AC etc complete as reqd.
7Supplying & charging of R-410 A gas in the exising Cassate type of 2 TR unit i/c pressure testing, flushing the system & gas charging complete etc as reqd.
8Supplying & laying of following size copper flexible FRLS PVC insulated PVC sheathed copper conductor cable unarmoured for making connection complete etc as reqd.
94C x 4 sq.mm
10SH- III (Supply of material)Following material /electrical accessories shall be supply by agency and fixing will be done by the existing man power existing for replacement on day to day maitenance works etc as required. (Labour already included in Item No. 1 & 2 Sub Head - I.)
115 Amp Modular Switch
125 Amp Modular Socket
1315/16 Amp Modular Switch
1415/16 Amp Modular Socket
156 to 32 Amp c Curve SP MCB, \\"C\\" curve, 10 kA breaking capacity
166 amps. to 32 amps. ratings , DP MCB, “C” curve, 10 KA breaking capacity
176 amps. to 32 amps. ratings , SPN MCB, “C” curve, 10 KA breaking capacity
186 amps. to 32 amps. ratings , TP MCB, “C” curve, 10 KA breaking capacity
193 mm thick phenolic laminated sheet i/c cutting of suitable size & fixing on existing switch board with fixing of all existing switch/socket/ Fan regulator.
2063 amps., 4 pole isolator
21100 amps., 4 pole isolator
221.5 Sq.mm FRLS Copper wire
234 Sq.mm ISI marked FRLS copper wire
246 Sq.mm FRLS Copper wire
252.50 mfd fan capacitor
261200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM / Min (Minimum) BLDC Fan
271400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/ Min (Minimum) BLDC Fan
28300 mm sweep heavy duty exhaust fans
29380 mm sweep heavy duty exhaust fans
30Call bell/ buzzer, single phase
31Stepped type Modular Fan regulator (2 module)
32Modular base & cover plate for 3 module
33Modular base & cover plate for 6 module
34Modular base & cover plate for 8 module
35Modular base & cover plate for 12 module
363 pole MCCB, 100A, 16kA
373 pole MCCB, 125A, 16kA
383 pole MCCB, 400A, 35kA
3918 watt LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials.
4036 watt LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. CRCA Sheet Body (Thickness > 0.50 mm)
4136 watt LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. CRCA Sheet Body (Thickness > 0.50 mm)
42100 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) of following body materials.
43SH- IV-Pump Supplying, Installation, Testing & Commissioning of Borewell submersible Pump set of following capacity suitable for working on 3 phase,415 volts A.C. supply 50 Hz i/c lowering in the sump well with the help of chain pulley block and tripod stand, connecting with existing delivering pipe lines, connections etc complete as reqd.
44Head 320-40 mtrs., discharg 0-105 LPM, 7.5 HP
45Lowering of 3/5/7.5/10 H.P. Submersible/ Mono-submersible pump/Sewage Submersible pump /sets in the underground tank or Borewell along with existing GI Pipe submersible cable etc. With the help of tri-port and chain pully block including P/F nub bolts, rubber packing, including testing, commissioning etc as required.
46Mono-Submersible Pump Set/Dewatering Pump Set.
47Lifting of 3/5/7.5/10 H.P. Submersible/ Mono-submersible pump/Sewage Submersible pump /sets from the underground tank or Borewell with the help of tri-port and chain pully block along with existing GI pipe and submersible cable etc complete as required.
48Mono-Submersible Pump Set/Dewatering Pump Set.
49Rewinding of 7.5/5 HP Submersible pump sets of following rating including cutting the burnt winding wire including rewinding the same with high quality motor resistance PVC Insulated copper winding the wire and credit of dismantled material i/c testing commissioning complete etc. as reqd.
507.5/5 HP Sbmersible Pump
51Providing and fixing of following 7.5/5 HP Submersible spare parts in the above motor i/c credit of old dismantled material etc as reqd.
52Rematling of shaft and Turning & Polishing of Rotor sleeve- 1 job
53G.M. Bush - 4 Nos.
54Rematling of Impeller and duffuser with Neck ring- 12 Nos.
55Oil/Water Seal- 2 Nos.
56Flat Cable 3X2.5 Sq.mm- 5 Mtr.
57Thrust plate and Thrust Bearing- 1Set
58Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required.
593 Core 4.0 Sq mm Flat Cable
60Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.
6150 mm dia.
62Providing & fixing of 8mm dia (N/S) stainless steel rope PVC coated with existing GI pipe to hole the clamp etc as required.
63Supplying and Replacement of gun metal gate valve ISI marked including fixing in the existing pipe line etc as required.
6450 mm dia.
65Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required.
6650 mm dia.
67SH- V (Credit for old dismantle material as and where basis etc as reqd)
68Old assorted copper/aluminium wire
69Old assorted 6/16 Amp Switch & sockets
70Old assorted light fitting
71Old assorted 1200/1400 mm Ceiling Fan
72Old assorted Exhaust Fan
73Old assorted MCB (5-32 Amp)
74Old assorted DP/TP (63/100Amp)
75Old assorted size Submersibel pump
76Old assorted GI Pipe
77Assorted size LED batten, 2x2 panel, downlighter Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56440122
AUTHORITY Government Departments
TENDER VALUE 18.25 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for maintenance of electrical installation And Fans, Compound Lights, repair maintenance Pump Sets & Maintenance Of Air Conditioners, Lifts, Dg Set, Ro Unit, Water Coolers, Stp Plant And Other E & M Services At Rajokari Institute Of Technology, Rajokari Under Emd South West During 2026-27. (Sh : electrical installation Work, Maintenance Of Air Conditioner & Pump Etc.).
Basic Detail
Tender No 38/EE (E)/PWD EMD South West/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 13 Jul 2026
Submission Date 20 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 18.25 Lakhs
Tender Fee Ref. Documents
EMD 36507
Exemption Not Available
Document List
Tendernotice_1 (10).pdf
BOQ_392893.xls
c193c7f2-211e-43ef-9af7-318c9161bff0.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1 (10).pdf

xls

BOQ_392893.xls

html

c193c7f2-211e-43ef-9af7-318c9161bff0.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders