Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56439676

Tender For Upgradation Of Apsara Boarder Underpass/Tunnel Illumination Under Pwd Sub Division-3/M2533, Delhi.

Issued by Government Departments · Delhi, Delhi
Tender Value
74.61 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
6 days left
EMD
1.49 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Upgradation Of Apsara Boarder Underpass/Tunnel Illumination Under Pwd Sub Division-3/M2533, Delhi.

BOQ

Name of Work:- Upgradation of Apsara Boarder underpass/tunnel illumination under PWD Sub Division-3/M2533, Delhi.
Sl. No. Item Description
1SITC of LED Linear Light luminaire on the wall with the help of SS temper proof fasteners shall provide a minimum lumen output of 21000 lumens with a minimum luminous efficacy of 140 lm/W and a maximum permitted wattage of 150W, available in a correlated color temperature (CCT) of 5700K/4000. It shall be constructed from a Extruded/ Aluminium powder coated pressure die cast housing with separate IP Box for driver and optics to ensure thermal isolation, finished with corrosion-resistant nano powder coating, and equipped with a UV-stabilized polycarbonate cover for optimal light distribution. The luminaire must include an integral encapsulated high-efficiency electronic driver c, operating within a voltage range of 90-305V AC, with a power factor >0.95, THD <10%, IP66 protection, inbuilt 6kv surge protection, and integrated SPD (20KV/10KA It must also feature miswiring, over-voltage, short circuit, reverse polarity, thermal protection & input over-voltage cut-off at 320V, and auto-recovery functionality. The luminaire must have ingress protection of IP66, impact resistance of IK≥08, a minimum LED life of 50,000 burning hours with lumen maintenance as per L80, and a CRI of ≥70. It shall be suitable for installation on Underpass/Tunnel, The luminaire and driver shall comply with IEC 60598, IS 10322-5, IS 161-03/05/06/07, IEC 61000-4-5 standards, with test reports for IES, LM 79, LM 80. It shall be CE and RoHS compliant. (light to light spacing is 10mtr or as per direction of Engineer-in-Charge (For Entry & Exit Point up to 50 meter length))
2SITC of LED Linear Light luminaire on the wall with the help of SS Temper proof fasteners shall provide a minimum lumen output of 21000 lumens with a minimum luminous efficacy of 140 lm/W and a maximum permitted wattage of 150W, available in a correlated color temperature (CCT) of 5700K/4000. It shall be constructed from a Extruded/ Aluminium powder coated pressure die cast housing with separate IP Box for driver and optics to ensure thermal isolation, finished with corrosion-resistant nano powder coating, and equipped with a UV-stabilized polycarbonate cover for optimal light distribution. The luminaire must include an integral encapsulated high-efficiency electronic driver c, operating within a voltage range of 90-305V AC, with a power factor >0.95, THD <10%, IP66 protection, inbuilt 6kv surge protection, and integrated SPD (20KV/10KA It must also feature miswiring, over-voltage, short circuit, reverse polarity, thermal protection & input over-voltage cut-off at 320V, and auto-recovery functionality. The luminaire must have ingress protection of IP66, impact resistance of IK≥08, a minimum LED life of 50,000 burning hours with lumen maintenance as per L80, and a CRI of ≥70. It shall be suitable for installation on Underpass/Tunnel, The luminaire and driver shall comply with IEC 60598, IS 10322-5, IS 161-03/05/06/07, IEC 61000-4-5 standards, with test reports for IES, LM 79, LM 80. It shall be CE and RoHS compliant. (light to light spacing is 15mtr or as per direction of Engineer-in-Charge (For Mid Level))
3SITC of LED Linear Light luminaire on the wall with the help of SS temper proof fasteners shall provide a minimum lumen output of 5000 lumens with a minimum luminous efficacy of 145 lm/W and a minimum permitted wattage of 35W with LIFEPO4- 9.6V/6Ah, Recharge Time 24Hrs, Emergency Battery Backup Min. 30minut @18W, available in a correlated color temperature (CCT) of 5700K/4000. It shall be constructed from a Extruded/ Aluminium powder coated pressure die cast housing with separate IP Box for driver, Battery and optics to ensure thermal isolation, finished with corrosion-resistant nano powder coating, and equipped with a UV-stabilized polycarbonate cover for optimal light distribution. The luminaire must include an integral encapsulated high-efficiency electronic driver c, operating within a voltage range of 90-305V AC, with a power factor >0.95, THD <10%, IP66 protection, inbuilt 6kv surge protection, and integrated SPD (20KV/10KA It must also feature miswiring, over-voltage, short circuit, reverse polarity, thermal protection & input over-voltage cut-off at 320V, and auto-recovery functionality. The luminaire must have ingress protection of IP66, impact resistance of IK≥08, a minimum LED life of 50,000 burning hours with lumen maintenance as per L80, and a CRI of ≥70. It shall be suitable for installation on Underpass/Tunnel, The luminaire and driver shall comply with IEC 60598, IS 10322-5, IS 161-03/05/06/07, IEC 61000-4-5 standards, with test reports for IES, LM 79, LM 80. It shall be CE and RoHS compliant. (light to light spacing is 20 mtr or as per direction of Engineer-in-Charge (Emergency Battery Backup ))
4Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Open Area as per direction of Engineer-in-Charge)
5200 Watt
6Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
74 X 16 Sq. mm armounrd Aluminum conductor power cable
84 X 25 Sq. mm armounrd Aluminum conductor power cable
93.5 X 50 Sq. mm armounrd Aluminum conductor power cable
10Supplying and Fixing pole box with hot press mounted SMC pole box of inside dimension 250mm x 250mm x 160mm deep having hinged cover with MS clamp of size 25mm x 5mm flat iron (NS) Nut and bolt washers etc. including suitable locking arrangement and 1no.SPMCB with all accessories mounting system and 3 phase aluminum backlight connector 16amp capacity for terminating of 3 phase cable including gasket connection complete etc. as required
11Supplying and Installation of following size perforated hot dipped galvinised iron cable rays (Galvanisation thickness not less than 50 migons) with perforation not more than 17.5% in convenient sections joined with connectors, fixed on the wall with steel fasteners of suitable size, GI Bolts & Nuts etc. completely cover the cables etc. to complete as required at site.
12100 mm width X 50 mm depth X 1.6 mm thickness
13Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
14Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
15Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56439676
AUTHORITY Government Departments
TENDER VALUE 74.61 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Upgradation Of Apsara Boarder Underpass/Tunnel Illumination Under Pwd Sub Division-3/M2533, Delhi.
Basic Detail
Tender No 48/EE(E)/PWD NES ED/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 13 Jul 2026
Submission Date 20 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 74.61 Lakhs
Tender Fee Ref. Documents
EMD 1.49 Lakhs
Exemption Available
Document List
BOQ_392894.xls
ea8bd8a2-ea84-4c8d-8047-a95f9fcf7709.html
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_392894.xls

html

ea8bd8a2-ea84-4c8d-8047-a95f9fcf7709.html

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders