| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises. |
| 5 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 6 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in unframed work complete all as specified and directed. |
| 7 | Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. |
| 8 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 9 | Taking down Chowkhats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. |
| 10 | Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out in soft / lose soil complete all as specified |
| 11 | Excavation over areas not exceeding 1.5m deep and getting out hard/dense type of soil complete all as specified and directed. |
| 12 | Excavating in trenches, n exc 1.50 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense type of soil complete all as specified and directed. |
| 13 | Excavating in trenches, n exc 1.50 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/ loose type of soil complete all as specified and directed. |
| 14 | Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as specified. |
| 15 | Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as specified. |
| 16 | M&L for Hand packing of stone boulders (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed. |
| 17 | M&L for Hardcore broken stone of gauge exc 40mm and n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 18 | M&L for PCC (1:4:8), Type D2 using 40 mm graded stone aggregate as in foundations, sub-base,filling and mass concrete complete all as specified. |
| 19 | M&L for 100 mm thick cement concrete (1:4:8) type D-2 using (40mm graded stone aggregate) as in Sub base of floor rough surface complete all as specified. |
| 20 | M & L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundations, sub-base,filling and mass concrete complete all as specified and dirceted |
| 21 | M & L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement laid in panels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed. |
| 22 | M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in bed blocks, coping, cills, steps, kneelers, bed plates, apex stones kerbs and similar works including necessary formwork complete all as specified and directed. |
| 23 | M&L for providing 25 mm thick cement concrete (1:2:4) type B-0 using (12.50mm graded stone aggregate) as in flooring to receive the topping layers complete all as specified. |
| 24 | M&L for Walling of square rubble ,coursed in retainning walls,abutments and similar works regular coursed,well bonded,bedded and solidly hearted,built in cement mortar(1:6) with lime/sand stone and PCC (1:3:6) type C1 precast bond stone (in lieu of stone bond stone ) set in cement mortar (1:4) brought upto courses Complete all as specified and directed Note :- (i) Precast PCC Bond stone shall be measured and paid separately against respective items(ii) RR Masonary will be measured after deducting PCC Bond stone |
| 25 | M&L for Walling of square rubble ,coursed in retainning walls, abutments and similar works regular coursed, well bonded, bedded and solidly hearted,built in cement mortar(1:6) with lime/sand stone and PCC (1:3:6) type C1 precast bond stone (in lieu of stone bond stone ) set in cement mortar (1:4) brought upto courses Complete except stone boulder all as specified and directed Note :- (i) Old Stone boulder obtained from the respective demoletion of stone masonry shall be reuse (ii) Precast PCC Bond stone shall be measured and paid separately against respective Items(iii) RR Masonary will be measured after deducting PCC Bond stone |
| 26 | M & L for precast PCC (1:3:6) type C1 using 20 mm graded stone aggregates) as bond stone use for retainning wall, abutment and similar works and set in cement mortar 1:4 including neceessary formwork Complete all as specified and directed |
| 27 | M&L for raised pointing to squared rubble, coursed or uncoursed in CM (1:3) complete all as specified and directed |
| 28 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 29 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete all as specified and directed. |
| 30 | Use and waste formwork to sides and soffits of floor or roof beam, beam hunching, girder, lintels, cantilever, shelves including supports etc for rough finished flat surfaces of concrete complete all as specified and directed |
| 31 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed |
| 32 | Material and labour for providing Reinforced Cement Concrete nominal mix 1:1.5:3 type A1 using 20 mm graded aggregate a in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed. |
| 33 | Material and labour for providing Reinforced Cement Concrete nominal mix 1:1.5:3 type A1 using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 34 | Material and labour for providing Reinforced Cement Concrete nominal mix 1:1.5:3 type A1 using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed. |
| 35 | Material and labour for providing Reinforced Cement Concrete nominal mix 1:1.5:3 type A1 using 20mm aggregate as in slab supported on walls , beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc comlpete all as specified and directed. |
| 36 | M & L for Mild steel TMT bars 10mm dia and over, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 37 | M & L for Mild steel TMT bars 6mm to 8mm dia and over, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 38 | M & L for Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 39 | M & L for brickwork with subclass 'B' or locally available best quality old size bricks, straight or curved on plan exc 6 m mean raduis, built in CM (1:6) complete all as specified and directed. |
| 40 | M & L for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified . |
| 41 | M & L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified. |
| 42 | M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified. |
| 43 | Supply only integral water proofing compound WPC complete all as specified. |
| 44 | M & L Non Skid ceramic tiles colour 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry complete all as specified. |
| 45 | M & L Glazed ceramic coloured tiles in vertical surface size 450mm x 300mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10mm thick screed bed or backing coat in cement mortar 1:4 laying of skirting/dado on walls all as specified and directed. |
| 46 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 47 | Supply and fix mild steel screw bolts (machine made) of 11 mm to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exceeding 10 cm but not exceeding 15 cm complete all as specified. |
| 48 | Supply and fix 5 mm thick mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 complete all as specified. |
| 49 | Supply and fix structural steel work in tubular/hollow sections trusses , Purlin , posts, rafter etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as as specified and directed. |
| 50 | S & F Solid PVC door frame of size 50mm X 47mm made out of 5 mm wood grain printed PVC sheet reinforced with mild steel square tube and edges will be painted to match with printed sheet complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010). |
| 51 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded wood grain printed plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of wood grain printed sheet, 15mm wide x 5mm thick PVC sheet beading used inside stiles and rail and decorative PVC beading of 10mm x 10mm (90 degree), used solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. Make: Rajshri or equivalent as approved. |
| 52 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified. |
| 53 | S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putting square n exc 0.5 sqm in each pane complete all as specified. |
| 54 | Supply and fix 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified. |
| 55 | S&F 75mm long MS Butt hinges, medium weight, cold rolled complete all as specified. |
| 56 | Supply and fix 150 mm long extruded aluminium alloy handles fabricated type anodised complete all as specified & directed . |
| 57 | Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 58 | Supply and fix in repair vitreous china Squatting pan, 'Orissa' pattern, Size 580 X 440mm ,with integral foot rests (excluding flushing ciestern and flush pipe) incl necessary cement concrete bedding and 100 mm bore cast iron 'P' trap with 550 to 600mm long neck for connecting WC to branch piece with cement joints complete all as specified & as directed . |
| 59 | S & F PVC valveless, syphonic action type, low level flushing cistren 10 ltr capacity ISI Marked incl all acessories and 32mm dia PVC flush / discharge pipe incl float valve, inlet complete all as specified. |
| 60 | S & F PVC connections 15mm dia size with PTMT nuts of length 450mm complete in all respect as specified |
| 61 | Supply and fix as 15 mm bore bib taps fancy type, chromium plated, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all specified and directed. |
| 62 | Supply and fix 15mm bore stop valves of cast copper alloy, screwed down, high pressure with crutch or butter fly handle, chromium plated and fixed complete all as specified. |
| 63 | Supply and fix 32mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/sqcm fixed complete all as specified and as directed. |
| 64 | Supply and fix 110mm dia PVC (SWR) pipes single socketed with rubber joint, in any length, laid in trenches or in floors / fixed to walls complete all as specified. |
| 65 | Supply and fix 75mm dia PVC (SWR) pipes single socketed with rubber joint, in any length fixed to walls / floors or in trenches complete all as specified. |
| 66 | Supply and fix 110mm dia PVC (SWR) bend suitable for pipe complete all as specified. |
| 67 | Supply & Fixed PVC (SWR) vent cowl 75mm suitable for pipe complete all as specified. |
| 68 | Supply and fix 110mm bore PVC (SWR) junction, single T equal or unequal with or without door access complete all as specified. |
| 69 | M & L PVC(SWR) floor trap, 75mm dia outlet, plain with grating including joint with solvent cement complete all as specified. |
| 70 | Supply & Fixed 110mm dia PVC (SWR) reducer suitable for pipe complete all as specified. |
| 71 | Supply & Fixed 110mm dia PVC (SWR) WC connector with lip ring suitable for pipe complete all as specified. |
| 72 | Supply & Fixed 110mm dia PVC (SWR) 'S' trap suitable for pipe complete all as specified. |
| 73 | S&F 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 74 | S&F 20mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 75 | Supply and fix as in repair 20 mm bore dia, Gun-metal, gate valves, with iron wheel head, screwed both ends on GI pipes with GI union fixed in existing/ new location complete all as specified and directed. |
| 76 | Supplying, hoisting, fixing and connecting up 1000 litre rotational moulded polythylene water storage tanks double layer (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. complete all as specified and as directed |
| 77 | Material and labour for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick high Pressure high pressure Non Asbestos Fiber Cement decorative Board (E-Board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall, flush fiiting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid and incl apply coloured painting work with two coat of acrylic emulsion paint over a coat of cement primer before installing it on the grid all as specified and directed. Make : Everest Industries Ltd or equivalent as per IS 14862 all as specified and directed. |
| 78 | M & L for preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified and directed. |
| 79 | Material and labour for applying two coats of cement base paint over one coat of primer on plastered surfaces of walls including preparation of new or previously untreated surfaces all as specified and directed |
| 80 | M & L preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 81 | E & M Division items |
| 82 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc including removing from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 83 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty,concealed PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 84 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, concealed PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 85 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, concealed PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 86 | M&L for point wiring with FRLSH stranded copper conductor 4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, concealed PVC Conduit concealed type of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board of AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 87 | S&F modular switch 1 way 6A/10A, 1 Module complete all as specified and directed. |
| 88 | S&F modular switch 1 way 16A/20A, 1 Module complete all as specified and directed. |
| 89 | S&F modular socket 6A/10A, 2/3 pin combined 2 module complete all as specified and directed. |
| 90 | S&F modular socket 16A/20A, 2/3 pin combined 2 module complete all as specified and directed. |
| 91 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 92 | S&F modular metal flush box 3 module with white cover plate with frame ISI marked complete all as specified and directed |
| 93 | S&F modular metal flush box 6 module with white cover plate with frame ISI marked complete all as specified and directed |
| 94 | Supply & Fix LED betten tube light fitting of capacity 20W, aluminum housing enhances safety, high quality PC diffuser, easy to install efficiancy 110/125lumen/watts operating on 230V, 50Hz, AC Supply, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 95 | Supply & Fix enviromental friendly bldg security street light, LED luminaire 25 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr-in–charge. |
| 96 | S&F plastic body exhaust fan 250mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces complete all as specified and as directed. |
| 97 | S&F sheet metal enclosure powder coated single phase and neutral (SPN) DB for fixing of MCBs, 4 way double door with aluminum bus bar 100 Amp including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 98 | S&F MCB SPN of capacity 6-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed. |
| 99 | S&F MCB SP of capacity 5-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed. |
| 100 | Taking out old existing earthing and M & L for new earthing with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 101 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 6 sqmm 2 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 102 | S & F GI tube light grade 25 mm bore with fittings for protection of cable, laid under road for passing cable complete all as specified and directed. |
| 103 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 104 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 105 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 106 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.Note : Thickness of sand cushioning after punning down will be measured. |
| 107 | M&L for bricks sub-class 'B' laid in trenches in flat style (width portion in horizontal shape) for cable protection complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 13, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender